Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product Approval
Florida Building Code 090T E 1%'7 D NOV 10 2015 Page 1 of 3 ILE Copy Roit Deptreld SCIS Home ;Log In i User Registration Hot Topa I Submit Surcharge ; Stats&Fads { Publications FBC Staff I BOS Site Map Links { Search Busines Product Approval Professi I lausm PUNIC tlser Regulation Product Aaoroval Menu>Pradxt or AcdLcAtion Search>AwAicatim list>ANAiothm DoWl FL* FL17022-112 Application Type Revision Code Version 2014 Application Status Approved Comments Archived I Product Manufacturer Extreme Metal Fabricators,LLC. Address/Phone/Email 2160 SW Poma Drive Palm City,FL 34990 (772)872-8034 tars@extrememetalfabricators.com Authorized Signature James Buckner jimmy@cbuckinc.net Technical Representative Tara Faulkner Address/Phone/Emali 2160 SW Poma Drive Palm City,FL 34990 (772)872-8034 tara@extrememetalfabricators.com Quality Assurance Representative Address/Phone/Email. Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer © Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed James L.Buckner,F.E.@ CBUCK,Inc. the Evaluation Report Florida License PE-31242 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 04/22/2024 Validated By Steven M.Urich,PE Validation Checklist-Hardcopy Received Certificate of Independence FL17022 R2 COI CertOfIndep.pdf Referenced Standard and Year(of Standard) Standard Year TAS 125 2003 UL 1897 2004 UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code hUp.//Www.floridabuildmg.orglpr/pr• am dtl.aSDX`r7Daram--w iF.VX(Zwtnnv7aRCi»iirdI 1All 911A14Z Florida Building Code Online Page 2 of 3 Product Approval Method Method I Option D Date Submitted 07/02/2015 Date Validated 07/02/2015 Date Pending FBC Approval 07/09/2015 Date Approved 08/18/2015 ummarv,of Products I Fl.# Model,Number or Name Description 17022.1 (1)S-V Crimp 26 Gauge Steel,Lapped Roof Panel,Mechanically Attached to Wood Deck. Limits of Use Installation Instructions Approved for use In HVHZ:No FL17022 R2 II I 5VCrimp 26ga WoodDeck EVALREPORT.odf Approved for use outside HVHZ:Yes Verified By:James L Buckner,P.E.@ CBUCK,Inc.P.E.*31242 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/At-101 Evaluation Reports Other:Refer to evaluation report for conditions FL17022 R2 AE 1 5VCrimp 26oa WoodDeck EVALREPORT.Rd and limitations of use.Refer to manufacturer's Created by Independent Third Party:Yes Installation instructions as a supplemental guide for attachment. 17022.2 (2)S-V Crimp 0.032"Aluminum,Lapped Roof Panel,Mechanically Attached to Wood —1 Deck. Limits of UseInstallation Instructions Approved for use In HVHZ,No FL17022 R2 11 ,2-5VCrImP 032AIum WoodDeck EVALREPORTPdf Approved for use outside HVHZ:Yes Verified By:James L.Buckner,P.E.@ CBUCK,Inc.P.E.#31242 Impact Resistant:No Created by Independent Third Party-Yes Design Pressure:+N/Al-168.5 Evaluation Reports Other.Refer to evaluation report for conditions FL17022 R2 AE 2 5VCrimo 032AIum WoodDeck EVALREPORT.pdf and limitations of use.Refer to manufacturer's Created by Independent Third Party:Yes installation instructions as a supplemental guide for attachment. 17022.3 (3)1.5"Mechanical Seam 2"Rib Height,16"Wide,24 Gauge Steel Roof Panel Mechanically Attached to Wood Deck. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R2 11 3 1.5 Approved for use outside HVHZ.Yes MechSeam 24ma WoodDeck W8LREPORT.Dd Impact Resistant:No Verified By:James L.Buckner,P.E.@ CBUCK,Inc.P.E.#31242 Design pressure:+N/At-191 Created by Independent Third Party:Yes Other:Refer to evaluation report for conditions Evaluation Reports and limitations of use.Refer to manufacturer's FL17022 R2 AE 3 1.5 installation instructions as a supplemental guide for MechSeam 2 a WoodDeck EVALRE Aq PORT.ndf attachment. 1 Created by Independent Third Party:Yes 17022.4 (4)1.5"Mechanical Seam 2"Rib Height,16"'Aricle,0.032"Aluminum Roof Panel Mechanically I Attached to Wood Deck. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R2 11 4 1.5 Approved far use outside HVHZ:Yes MechSeam 032AIum WoodDeck EVALREPORToff Impact Resistant:No Verified By:James L.Buckner,P.E.@ CBUCK,Inc.P.E.#31242 Design Pressure:+N/A(-191 Created by Independent Third Party:Yes Other:Refer to evaluation report for conditions Evaluation Reports and limitations of use.Refer to manufacturer's FL17022 R2 AE 4 iz installation instructions as a supplemental guide for MechSeam 032AIum WoodDeck EVALREPORT.od attachment. Created by Independent Third Party:Yes 17022.5 rip I"Rib Height,16"Wider 26 Gauge Steel Roof Panel Mechanically Attached to Wood Deck. Limits of Use Installation Instructions Approved for use in HVHZ:No FL17022 R2 11 5 INailStrin 26oaWoodDeck EVALREPORT.pdf Approved for use outside HVHZ:Yes Verified By:James L.Buckner,P.E.@ CBUCK,Inc.P.E.#31242 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure-+N/At-97.25 Evaluation Reports Other:Refer to evaluation report for conditions FL17022 R2 AES-lNaitStrip 26ga WoodDeck EVALREPORT.pd and limitations of use.Refer to manufacturer's Created by Independent Third Party:Yes installation instructions as a supplemental guide for attachment. 17022.6 rip 1"Rib Height,16"Wide,0.032"Aluminum Roof Panel Mechanically Attached to Wood Deck, http://wWw.floridabuilding.org/pr/pr_app dti.asvx?Daram---wCTFVY()u7tT',--,,,')-,r"-,—T-T---fI /P%IN monda Building Code Online Page 3 of 3 Limits of Use installation instructions Approved for use in HVHZ:NO FL17022 R2 IT 6 I.NailStrlp- 032AIum WoodDeck EVALREPORT.odf Approved for use outside HVHZ:Yes Verified By:James L Buckner,P.E.@ CBUCK,Inc.P.E.#31242 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/At-78.5 Evaluation Reports Other:Refer to evaluation report for conditions FL17022 R2 AE 6 INallStrip 032A1um WoodDeck EVALREPORT.Pdf and limitations of use.Refer to manufacturer's Created by Independent Third Party:Yes installation instructions as a supplemental guide for attachment. 17022.7 (7)1.5"Nail Strip 1.5'Rib Height,19'Wide,26 Gauge Steel Roof Panel Mechanically I Attached to Wood Deck. Limits of Use Installation Instructions Approved for use In HVHZ:No FL17022 R2 11 7 1.5NailStrip 26ga WoodDeck EVALREPORT.pdf Approved for use outside HVHZ-Yes Verified By:James L.Buckner,P.E.@ CBUCK,Inc.P.E.#31242 Impact Resistant:No Created by Independent Third Party:Yes Design Pressure:+N/A/-63.5 Evaluation Reports Other:Refer to evaluation report for conditions 1117022 R2 AE 7 1.SNailStyip 26na WoodDeck odf and limitations of use.Refer to manufacturer's Created by Independent Third Party:Yes installation instructions as a supplemental guide for attachment. F-kl Next Contact Us::IM N2ft Monroe Stinat.Tallahassee FL 321*9 MSM 850487-1824 The State of Florida is an AVEEO employer.Coqvdght2pq7-2oj3 SateofFlorida.::Pnvvacy Accessibility Statement::Rdmnd StatemeM i Under Florida law,email addresses are public reoords_if you do riot want your e-mail address released in response to a ptibiic—reccirds recluest,do not send electronic mail to this erttity.Instead,contact th--office by phone or by traditional mail.if you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must priovide,the Department with an email addn--s if they have one.The emits provided may be used for official communication with the licensee.However email addresses are public record.If you do not Wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under chapter 455,F-S_,please clickIrgm. Product Approval A - : WWRE SCOArit"giggs. http://www.floridabuilding.org/pr/pr_app_Atl.aspx?i)aram---WC:rF,VXOwtDnv-)n-Rn,,W,j I