Loading...
HomeMy WebLinkAboutEngineering FILEcc)py -.a NOV 12 2015 PAUL WELCH INC. Mechanical Electrical Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie,FL 34984 Phone(772)785 -9888 Email pwelchinc@aol.com November 9, 2015 Re: Crawford Re-Roof 2808 Nine Iron Dr. Port St. Lucie,FL 34952 SCOPE OF WORK: Remove existing roofing and install new Standing Seam Metal Roof(Metal Sales Manufacturing Corporation FL# 11560.4) at above referenced residence address over new underlayment and existing plywood sheathing. (Flat Roof Not Included) DESIGN CRITERIA: FBC 2014 ASCE?-10 PROJECT DATA: BUILDING HIEGHT=8'-0" A=3' MEAN ROOF HIEGHT=<12' ROOF ANGLE=3:12 SHAPE=PITCHED GABLE ROPROTANCE FACTOR= 1.00 WIND VELOCITY V ult= 160 MPH WIND VELOCITY V asd= 124 MPH EXPOSURE=C ENCLOSURE CLASS=ENCLOSED BUILDING INTERNAL PRESSURE COEFFICIENT=-0.18 APPLIED UPLIFT DESIGN PRESSURES ON SLOPED ROOF (usfl: ZONE 1 (Field)=-31.9 ZONE 2 (Perimeter/Ridge)_-53.9 ZONE 3 (Comers)_-79.2 f Paul Welch Inc. Paul`Welch°P.E. Reg. No. 29945 _ November-9,2015 2808 Nine Iron Dr.Port St.Lucie,FL 34952 `-_ ,°� 1 of 3 ROOFING ATTACHMENT REOUHtEMENTS: Metal roofing to be attached with#10- 12 x 1 1/z" long(minimum 1/4"penetration through plywood sheathing)pancake head screws along the panel seam. ALL ZONES : Screws spaced at 24" on center along the seam of the panel. Product Design Uplift Pressure: -84.25psf 79.2 < 84.25 Therefore O.K. UNDERLAYMENT• Underlayment shall be TRI-BUILT Roofing Products(Tri-Built S/A HT TU Underlayment) FL# 16048.1 Priming deck is optional although recommended. Apply sheet parallel to the roof edge. Adhere the exposed part to the substrate,firmly roll the membrane into place to acheve a bond. Horizontal seams shall have minimum 3"lap,vertical seams shall have minimum 6"lap and staggered not less than 24"from vertical laps below. All over-granule end laps shall be sealed using heat-weld or hot air welding techniques. Tri-Built S/A HT TU Underlayment shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Section 1507. DECK INSTALLATION: Re-nail all plywood sheathing(15/32"thick minimum)with 8D ring-shank nails at 4" O.C. perimeter and 6"O.C. field for all zones. All work to be in compliance with product approval (FL# 11560.4), (FL# 16048.1), manufacturer's specifications, and the Florida Building Code 2014. Paul Welch Inc. Paul=Welch-P;E. Reg:-,N6.,29945 Noveriiber;_9,-2015. _ ^o Oma•_ YT _ .I 2808 Nine Iron Dr.Port St.Lucie,FL 34952 Q 2 of 3 a SLA T P7 Dof=h 1.10? s tL.� 1 � jig NOT 3wct,upe� ROOF ZONE PLAN A=3' ZONEDESIGNA770N(TYPICAL) Paul Welch Inc.s c Paul Welch P.E::Rcg.No 29945 November'9 -2015 2808 Nine Iron Dr.Port St.Lucie,FL 349520° -�3 of 3