Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 1 ....1:-.F' ,,l 2 .i i Fla fiGlidaDepaitwrittif BCIS Home Log In i User Registration f Hot Topics f Submit Surcharge Stats&Facts Publications FBC Staff ; BCIS Site Map ! Links ; Search 8usines (?� Y Professi nal s�l: icUseuct roval Regulation Product Approval Menu>Product or Application Search>Application List Search Criteria Refine Search Code version 2014 FL# 11560.4 Application Type ALL Product Manufacturer ALL Category ALL Subcategory ALL Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model,Number or Name ALL Product Description ALL Approved for use in HVHZ ALL Approved for use outside HVHZ ALL Impact Resistant ALL Design Pressure ALL Other ALL Search Results-Ap lications FL# Twe Manufacturer Validated By Status FL11560- Revision Metal Sales Manufacturing Corporation Yoosef Lavi, Approved R2 FL#:FL11560.4 P.E. History Model:Image II (214)340- Description:Min.26 ga.,max. 16"wide standing seam roof panel over 0049 min.15/32"thick plywood deck Category:Roofing Subcategory:Metal Roofing *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Contact Us::1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: E9 M sccurit�'arW�m cies' -r Wr http://www.floridabuilding.org/pr/pr_app_lst.aspx 11/9/2015 4; a1 EVALUATION REPORT OF METAL SALES MANUFACTURING CORPORATION s `26 GA.IMAGE 1I PANEL' j FLORIDA BUILDING CODE 5TH EDITION (2014) FLORIDA PRODUCT APPROVAL f FL 11560A-R2 ROOFING . METAL ROOFING 3 Prepared For: Metal Sales Manufacturing Corporation 545 South yd Street,Suite 200 f Louisville,KY 40202 t Telephone: (502)8554300 Fax: (502)8554290 Prepared By: Bala Sockalingam,Ph.D.,P.E. Florida Professional Engineer#62240 1216 N]Lansing Ave.,Suite C Tulsa,OK 74106 Telephone: (918)492-5992 FAX: (866)366-1543 This report consists of Evaluation Report(2 Pages including cover) Installation Details (1 Page) `+ a t��aeeuutat�, eea SOCKUlf"', f"ire ooe gyp.- ....... ``% QQ.e;y��•,E S•,��9 ice® a' No 62240 Report No. C20094 0 "� Date:3.27.15 : O STATE OF * LE e e e S.2—t.2-0 t5- FL 11560.4-R2 C2009-4 3.27.15 Page 2 of 2 Manufacturer: Metal Sales Manufacturing Corporation Product Name: Image II Panel Description: Max. 16" wide coverage with V high ribs Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Deck Description: Min. 15/32" thick plywood for new and existing constructions. Designed and installed as per FBC 2014. Deck Attachment: 8d x 2.5" long ring shank nails or 48 x 2" long wood screws @ 6" o.c. (Minimum) in the plywood field and @ 4" o.c. at edges New Underlayment: Minimum underlayment as per FBC 2014 Section 1507.4.5.1 Existing Underlayment: One layer of asphalt shingles over one layer of#30 felt. For reroofing (Optional) construction only. Slope: 2:12 or greater in accordance with FBC 2014 Section 1507.4.2 Design Uplift Pressure: 84.25 psf @ fastener spacing of 24" o.c. (Factor of Safety=2) Fastener Pattern: 410-12 pancake head screws along panel seam. Fastener shall be of sufficient length to penetrate through the deck a minimum of 1/d". Test Standards: Roof assembly tested in accordance with TAS 125-03 `Standard Requirements for Metal Roofing Systems'. Code Compliance: The product described herein has demonstrated compliance with FBC 2014 Section 1507.4 Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2014 Section 1505 and current approved roofing materials directory or ASTM E108/UL790 report from an accredited laboratory for fire ratings of this product. Supporting Documents: TAS 125 Test Reports Hurricane Test Laboratory,LLC HTL Report#: 0103-0714-09,Reporting Date 9/1%09 OMWN Bh CNECD.art Ba os PLOT: DAIS: i/25/15 NEW UNDERLAYMENT to SEE DETAIL 1 V EXISTING SHINGLES MAX. 16" �PRESSURE ER ROOF PANEL (OPTIONAL) ALLOWABLE BLE, � u uN As u \ u O PLYWOOD n EXISTING UNDERLAYMENT MINIMUM ATTACHMENT: 15/32° THICK (MIN.) g (OPTIONAL) 8d x 2.5" LONG RING SHANK NAIL 4—MIN. 2X_ WOOD RAFTER/JOIST/ OR #B x 2" LONG WOOD SCREWS TRUSS AT MAX. 24" O.C. SPACED 0 6" O.C. IN THE FIELD o & 0 4" D.C. AT PLYWOOD EDGES 0 N C9 W N O TYPICAL PANEL INSTALLATION X-SECTION V)C04 0 a O E Y M.� I N FV�1� MIN 26 GA. PANEL �� ALLOWABLE UPLIFT PRESSURE is� FASTENER PRESSURE Ci SPACING (PSF) g NEW UNDERLAYMENT EXISTING SHINGLES #10 PANCAKE SCREWS u1 24 84.25 d A, (OPTIONAL) � " T ul a a zan 2� =gym EXISTING UNDERLAYMENT GENERAL NOTES:' (OPTIONAL) "PLYWOOD 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE 15/32" THICK (MIN.) FLORIDA BUILDING CODE (FBC). DETAIL 1 2. ROOF PANELS ARE SHALL BE MIN. 26 GA. MAX. EFFECTIVE COVERING WIDTH OF PANEL = 15'. 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS SPECIFIED ON THIS DRAWING. 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT, THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING, 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL. 6• RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS. 2009-4 PAGE NO, OF