,_ FL# FL16048-R2
Application Type Revision
Code Version 2014
Application Status Approvedv^,
N
Comments
Archived
Product Manufacturer TRI-BUILT Roofing Products
Address/Phone/Email 9050 Louisiana Street
Merrillville,IN 46410
(201)842-2449
david.ru iz@tribu iltmaterialsgroup.cam
Authorized Signature David Ruiz
david.ruiz@tribuiltmaterialsgroup.com
Technical Representative David Ruiz
Address/Phone/Email 250 Route 17 North
East Rutherford,NJ 07073
(201)842-2449
david.ruiz@tr'tbuiltmateriaisgroup.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/24/2016
Validated By John W.Knezevich,PE
II Validation Checklist-Hardcopy Received
Certificate of Independence FL16048 R2 COI 2015 01 COI Nieminen.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2009
ASTM G155 2005
FM 4474 2004
FRSA/TRI April 2012(04-12) 2012
TAS 103 1995
Equivalence of Product Standards
Certified By
Sections from the Code
http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtFPmdYiNDWr... 11/9/2015
Florida Building Code Online Page 2 of 2
Product Approval Method Method 1 Option D
Date Submitted 03/23/2015
Date Validated 03/29/2015
Date Pending FBC Approval 03/31/2015
Date Approved 06/22/2015
Date Revised 10/08/2015
Summary of Products
FL# Model,Number or Name Description
16048.1 TRI-BUILT Roof Underiayments Self-adhering,modified bitumen roof underlayments
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16048 R2 II 2015 03 FINAL ER TRI-
Approved for use outside HVHZ:Yes BUILT UNDERLAYMENTS FL16048-R2.pdF
Impact Resistant:N/A Verified By: Robert Nieminen PE-59166
Design Pressure:+N/A/-315 Created by Independent Third Party:Yes
Other:1.)The design pressure noted herein pertains to use Evaluation Reports
of foam-on the systems overtop the self-adhering FL16048 R2 AE 2015 03 FINAL ER TRI-
underlayment for one particular application.See ER Section BUILT UNDERLAYMENTS FL16048-R2.pdf
5.6 for details.2.)Refer to ER Section 5 for other Limits of Created by Independent Third Party:Yes
Use.
Back F.7—
Contact Us::1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click L%3L.
Product Approval Accepts:
® eG;cf M
svcuritvmi,rHIC.;-
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?parain=wGEVXQwtDgtFPmdYiNDWr... 11/9/2015
EXTERIOR RESEARCH&DESIGN,LLC.
Certificate ofAuthorization#9503
I} 353 CHRISTIAN STREET,UNIT#13
M TRIN11�Y 1 ERD OXFORD,CT 06478
PHONE:(203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
TRI-BUILT Roofing Products Evaluation Report A42960.10.12-R2
9050 Louisiana Street FL16048-112
Merrillville,IN 46410 Date of Issuance:10/25/2012
Revision 2: 03/20/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 5th Edition(2014)Florida Building Code sections noted herein.
DESCRIPTION: TRI-BUILT Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity[ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 5.
Prepared by:
The facsimile seal appearing was authorized by Robert Nieminen,
Robert J.M.Nieminen,P.E.
P.E.on 03/20/2015.This does not serve as an electronically signed
Florida Registration 1U0.59266 Florida DCA ANEI983 document.Signed,sealed hardooples have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
�44_ TRINITI� ER®
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: TRI-BUILT Roof Underlayments, as produced by Allied Building Products Corp., have demonstrated
compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.4,1507.2.9.2,1507.5.3 Physical Properties ASTM D1970 2009
1504.6 Accelerated Weathering ASTM G155 2005
1504.3.1 Wind Uplift FM 4474 2004
1507.3.3 Installation Practice FRSA/TRI April 2012(04-12) 2012
1523.6.5.2.1 Physical Properties TAS 103 1995
3. REFERENCES:
Entity Examination Reference Date
ERD(TST6049) Physical Properties P33360.06.10 07/01/2010
ERD(TST6049) Physical Properties P33370.03.11 03/02/2011
ERD(TST6049) Physical Properties P33370.04.11 04/26/2011
ERD(TST6049) Physical Properties P369.09.11 09/01/2011
ERD(TST6049) Physical Properties P37300.10.11 10/19/2011
ERD(TST6049) Physical Properties 544870.04.14-2 04/02/2014
ERD(TST6049) Physical Properties S44870.04.14-3 04/02/2014
ERD(TST6049) Physical Properties 544870.04.14-1 04/10/2014
ERD(TST6049) Physical Properties 544870.04.14-4 04/10/2014
ERD(TST 6049) Physical Properties 6020.07.14-1 09/08/2014
ERD(TST 6049) Physical Properties 6020.09.14-5 09/08/2014
FM Approvals(TST1867) Wind Uplift 3004091 01/12/2000
Miami-Dade(CER 1592) FBC HVHZ Compliance 12-1213.10 04/11/2013
PRI(TST5878) Physical Properties PUSA-083-02-01 07/01/2008
UL,I.I.C.(QUA9625) Quality Control Multiple-Listing 02/27/2012
UL,LLC.(QUA9625) Quality Control Multiple-Listing R16814 04/12/2012
UL,LLC.(QUA9625) Quality Control Service Confirmation,R14571,2QA Exp.10/24/2015
UL,I.I.C.(QUA9625) Quality Control Service Confirmation Exp.10/26/2017
4. PRODUCT DESCRIPTION:
4.1 Self-Adhering Underlayments:
4.1.1 Tri-Built Granular-P Shingle Underlayment is a nominal 60-mil thick rubberized asphalt waterproofing membrane,
glass fiber reinforced,with an aggregate surface;meets ASTM D1970.
4.1.2 Tri-Built Tile and Metal HT Underlayment is a nominal 60-mil thick dual-layer rubberized asphalt waterproofing
membrane,fiberglass reinforced,with a polyester fabric surface;meets ASTM D1970 and TAS 103.
4.1.3 Tri-Built Sand-R SA Shingle Underlayment is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified
bitumen roof underlayment,with a 36-inch sheet width.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way,the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ
5.3 Fire Classification is not part of this Evaluation Report,refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed,a request may be made to the AHJ for approval based on
this evaluation combined with supporting data for the prepared roof covering.
Exterior Research and Design,LLC. Evaluation Report A42960.10.12-R2
CertUlcate ofAuthorization#9503 FL16048-R2
Revision 2:03/20/2015
Page 2 of 5
\, T®R1N1-M ER®
I
5.5 Allowable roof covers applied atop the underlayments are as follows:
TABLE 1: ROOF COVER OPTIONS
UnderlaymentAsphalt Wood Shakes
Shingles Nail-On Tile Foam-On Tile Metal &Shingles Slate
Tri-Built Granular-P Shingle
Yes No No No Yes Yes
Underlayment
Trl-Built Tile and Metal HT Yes Yes Yes Yes Yes Yes
Underlayment See 5.5.1
Tri-Built Sand-R SA Shingle Yes No No No Yes Yes
Underlayment
5.5.1 "Foam-On Tile"is limited to use of the following Approved the adhesives unless tensile adhesion/long term aging
data from an accredited testing laboratory is provided.
➢ Tri-Built Tile and Metal HT Underlayment with 3M'" 2-Component Roof Tile Adhesive AH-160 (FL6332), 3M'
Foam Roof Tile Adhesive RTA-1(FL6276)or DowTlleBond(FL717)
5.6 Allowable substrates are noted below:
5.6.1 Direct-Bond to Deck:
Tri-Built Granular-P Shingle Underlayment and Tri-Built Tile and Metal HT Underlayment applied to:
Y New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed
existing plywood; New or existing unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41
primed Southern Yellow Pine; ASTM D41 primed structural concrete, Huber Engineered Woods "ZIP System"
Panels(designed and installed to meet wind loads for project).
Note:Allied Building Products Corp.does not require priming of new or existing plywood sheathing for use with Tri-Built Granular-P
Shingle Underlayment or Tri-Built Tile and Metal HT Underlayment New or existing plywood sheathing should be cleaned of all dirt
and debris prior to application of these TRI-BUILT membranes.
Tri-Built Sand-11 SA Shingle Underlayment applied to:
Y Plywood;ASTM D41 primed plywood;OSB;ASTM D41 primed OSB;ASTM D41 primed structural concrete.
Note:While not required over plywood,Allied Building Products Corp. recommends priming the deck if the final roof cover is not
slated for installation within 24 hours.
Note:Allied Building Products Corp.requires tongue-ond�groove board decking be covered with plywood or OSB prior to installation
of the self-adhering underlayment.
5.6.1.1 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (0412) does not
address wind uplift resistance of all underlayment systems beneath foam-on tile systems, where the underlayment
forms part of the load-path. The following wind uplift limitations apply to direct-deck underlayment systems that are
not addressed in FRSA/TRI April 2012(0412)and are used in foam-on tile applications. Maximum Design Pressure is
the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing
pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for
determination of design wind pressures.
5.6.1.1.1 Maximum Design Pressure=-315 psf.
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer: ASTM D41
Underlayment: Tri-Built Tile and Metal HT Underlayment.
5.6.1.1.2 All other direct-deck, adhered TRI-BUILT underlayment systems beneath foam-on tile systems carry a Maximum
Design Pressure of-45 psf.
Exterior Research and Design,I.I.C. Evaluation Report A42960.30.12-112
Certificate of Authorization#9503 F1.16048-112
Revision 2:03/20/2015
Page 3 of 5
TRINITY i ER®
I
5.6.2 Bond-to-Insulation:
Tri-Built Granular-P Shingle Underlayment and Tri-Built Tile and Metal HT Underlayment applied to:
➢ ASTM C1289,Type 11,Class 1 po lyisocyanu rate or Type V polyisocyanurate-composite insulation;Dens Deck Prime;
or SECUROCK Gypsum-Fiber Roof Board.
Note:Forinstallotion under mechanically attached prepared roof coverings,insulation shall be attached per minimum requirements
of the prepared roof covering manufacturer's Product Approval. For installations underfoom-on file systems,insulation attachment
shall be designed by a qualified design professional and Installed based on testing of the Insulation/underlayment system in
accordance with FM 4470,Appendix KorTAS 114,Appendix J.
5.6.3 Bond to Mechanically Attached Base Laver:
➢ ASTM D226,Type I or II felt.
Note:For installations under mechanically attached prepared roof coverings,base layer shall be attached per minimum codified
requirements. For installations under foam-on tile systems,base layer shall be attached per minimum requirements of FRSA/TRI
April 2012(04-12).
5.7 Exposure Limitations:
5.7.1 Tri-Built Granular-P Shingle Underlayment shall not be left exposed for longer than 90-days after installation.
5.7.2 Tri-Built Tile and Metal HT Underlayment shall not be left exposed for longer than 180-days after installation.
5.7.3 Tri-Built Sand-R SA Shingle Underlayment shall not be left exposed for longer than 30-days after installation
6. INSTALLATION:
6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with Allied Building Products Corp. / TRI-BUILT
published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted
below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application,and prime the substrate(if applicable).
6.3 Tri-Built Granular-P Shingle Underlayment and Tri-Built Tile and Metal HT Underlayment:
6.3.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Sections 1507
for the type of prepared roof covering to be installed.
6.3.2 For non-tile applications:
6.3.2.1 Back-nail selvage edge seams in accordance with the Allied Building Products Corp./TRI-BUILT Back-Nailing Guide.
Nails shall be corrosion resistant,it gauge ring-shank type with a minimum 1-inch diameter metal disk or Simplex-
type metal cap nail,at a minimum rate of 12"o.c. The head lap membrane is to cover the area being back-nailed.
6.3.2.2 All seal-lap seams(selvage laps)must be firmly �.
rolled with a minimum 28 Ib. hand roller to _l
+ �;
ensure full contact and adhesion. For Tri-Built a , :
Tile and Metal HT Underlayment, align the °
edge of the top sheet to the end of the glue r
pattern(the sheet will overlap the fabric). ,F' xi^
r
View of overlap Seam;Tri-Built Tile and Metal HT Underlayment
6.3.2.3 Install to ensure full contact with approved substrates. Allied Building Products Corp./TRI-BUILT require a minimum
of 4046 weighted-roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied for the
field membrane. Hand rollers are acceptable for rolling of patches,laps(min.28 Ib roller)or small areas of the roof
that are not accessible to a large roller or broom.
Exterior Research and Design,LLC. Evaluation Report A42960.10.12-R2
Certificate of Authorizatfon#9503 FU6048-R2
Revision 2:03/20/2015
Page 4 of 5
TRIM ERD
{
6.3.3 For the applications(Til-Bullt Tile and Metal HT Underlayment only):
6.3.3.1 Reference is made to FRSA/TRI April 2012(0412)Installation Manual-and Table 1 herein.
6.3.3.2 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to
Polyglass published requirements for the staging.
6.3.3.3 Battens and/or Counter-battens,as required by the file manufacturer and FRSA/TRI April 2012(04-12)must be used
on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or sail-
boards,to prevent tile sliding and/or damage to the underlayment during the loading process.
6.3.3.4 The minimum cure time after installation of self-adhering membranes and before loading of roofing tiles is forty-
eight(48)hours
6.4 Tri-Built Sand-R SA Shingle Underlayment:
6.4.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections 1507 for the
type of prepared roof covering to be installed.
6.4.2 For non-tile applications:
6.4.2.1 While priming is optional,Allied Building Products Corp. recommends priming the deck if the final roof cover is not
slated for installation within 24 hours.
6.4.2.2 Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of release
film.
6.4.2.3 Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
6.4.2.4 Once the entire length of membrane is in place, peel-off the release film diagonally while holding the membrane
tight. Firmly roll the membrane into place to achieve a bond.
6.4.2.5 Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-inches and
staggered not less than 2-ft from vertical seams in the course below. All over-granule end-laps shall be sealed using
either heat-welding or hot air welding techniques.
6.4.2.6 When installing at slopes above 8:12,Allied Building Products Corp recommends back-nailing in the overlap area at
the top of the sheet at 12-inch o.c.
6.4.2.7 For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over
valley or ridge.Drape and press sheet into place,working from the center of the valley or ridge in each direction. For
valleys,apply the sheet starting at the lowest point and work upward.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C.Rule 9N-3 QA requirements.
9. QUALITY ASSURANCE ENTITY:
UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation Report A42960.10.12-R2
Certificate of Authorization#9503 F1.16048-112