Loading...
HomeMy WebLinkAboutProduct Approval (3) Florida Building Code Online Page 1 of 4 fit Florida Departmentof BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts i Publications# FBC Staff BCIS 1Site Map Links Search Busines@USER:Professinal Product Approval Public User Regulation � Product Approval Menu>Product or Application Search>Application List>Application Det c FL# FL17676-R1 4W jr Application Type Revision Code Version 2014 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer MI Windows and Doors Address/Phone/Email 650 West Market Street Gratz,PA 17030 (717)365-3300 Ext 2560 bsitlinger@miwd.com Authorized Signature Brent Sitlinger bsitlinger@miwd.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Single Hung Compliance Method Certification Mark or Listing Certification Agency American Architectural Manufacturers Association Validated By Steven M. Urich,PE ® Validation Checklist-Hardcopy Received Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA 101/I.S.2/A440 2008 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 07/14/2015 Date Validated 07/14/2015 Date Pending FBC Approval Date Approved 07/23/2015 http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvFGYZsjrZF... 11/10/2015 Florida Building Code Online Page 2 of 4 Summary of Products FL# Model,Number or Name Description 6755. .3540=SH. � Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL17676 RI C CAC APC 3540 Fin 36x74 pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 04/12/2017 Design Pressure:+35/-50 Installation Instructions Other: LC-PG35. Units must be glazed in accordance with FL17676 R1 II Install-3540 SH 36 x74 Fin odf ASTM E1300-04. Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 17676.2 3540 SH 36x84 Fin Frame Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL17676 R1 C CAC APC 3540 Fin 36x84.pd Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 07/27/2020 Design Pressure:+40/-50 Installation Instructions Other:LC-PG40. Units must be glazed in accordance with FL17676 R3 II Install-3540 SH Fin 36x84 odf ASTM E1300-04. Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 17676.3 3540 SH 40x66 Fin Frame Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17676 R1 C CAC APC 3540 Fin 40x66 pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 08/26/2016 Design Pressure: +35/-45 Installation Instructions Other: R-PG35. Units must be glazed in accordance with FL17676 R1 II Install-3540 SH Fin 40x66 odf ASTM E1300-04. Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 17676.4 3540 SH 44x63 Fin Frame Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL17676 R1 C CAC APC 3540 Fin 44x63.pd Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 05/26/2020 Design Pressure: +40/-47 Installation Instructions Other: R-PG40. Units must be glazed in accordance with FL17676 R1 II Install-3540 SH Fin 44x63 odf ASTM E1300-04. Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 17676.5 3540 SH 44x72 Fin Frame Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL17676 RS C CAC APC 3540 Fn 44x72.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 08/01/2017 Design Pressure:+35/-47 Installation Instructions Other:R-PG35. Units must be glazed in accordance with FL17676 R1 II Install-3540 SH Fin 44x72.odf ASTM E1300-04. Verified By:American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 17676.6 3540 SH 44x84 Fin Frame Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL17676 R1 C CAC APC 3540 Fin 44x84.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 04/12/2017 Design Pressure: +30/-30 Installation Instructions Other:LC-PG30. Units must be glazed in accordance with FL17676 R1 II Install-3540 SH Fin 44x84.odf ASTM E1300-04. Verified By: American Architectural Manufacturers Association Created by Independent Third Party: http://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgvFGYZsjrZF... 11/10/2015 Florida Building Code Online Page 3 of 4 Evaluation Reports Created by Independent Third Party: 17676.7 3540 SH 52x84 Fin Frame Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL17676 R1 C CAC APC 3540 Fin 2x84 pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 05/26/2020 Design Pressure: +25/-25 Installation Instructions Other: R-PG25. Units must be glazed in accordance with FL17676 R1 II Install-3540 SH Fin 52x84 odf ASTM E1300-04. Verified By: American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 17676.8 3540 SH 36x74 Finless Frame Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17676 R1 C CAC APC 3540 FLS 36x74 odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 08/28/2017 Design Pressure:+35/-50 Installation Instructions Other:LC-PG35 FL17676 R1 II 08-01252A 511854A odf Verified By: Luis R. Lomas,PE PE-62514 Created by Independent Third Party:Yes Evaluation Reports FL17676 R1 AE 511854A 3540 Fls 36x74.pdf Created by Independent Third Party: Yes 17676.9 3540 SH 36x84 Finless Frame Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17676 R1 C CAC APC 3540 FLS 36x84 odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 07/27/2020 Design Pressure: +40/-50 Installation Instructions Other: LC-PG40 FL17676 R1 II 08-01372 511989.odf Verified By: Luis R. Lomas,PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL17676 R1 AE 511989 3540 FLS 36x84,pd Created by Independent Third Party:Yes 17676.10 3540 SH 44x72 Finless Frame Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL17676 R1 C CAC APC 3540 FLS 44x72 odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 08/28/2017 Design Pressure: +35/-47 Installation Instructions Other:LC-PG35 FL17676 R1 II 08-01247A 511849A.odf Verified By: Luis R. Lomas,PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL17676 R1 AE 511849A 3540 FIs 44x72.pdf Created by Independent Third Party:Yes 17676.11 3540 SH 48x96 Finless Frame Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL17676 R1 C CAC APC 3540 FLS 48x96.pd Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 08/28/2017 Design Pressure: +30/-30 Installation Instructions Other: LC-PG30 FL17676 R1 II 08-01371A 511988A.Ddf Verified By: Luis R Lomas,PE PE-62514 Created by Independent Third Party:Yes Evaluation Reports FL17676 R1 AE 511988A 3540 FLS 48x96.pdf Created by Independent Third Party:Yes 17676.12 3540 SH 52x62 Finless Frame Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL17676 R1 C CAC APC 3540 FLS 52x62.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 08/27/2017 Design Pressure: +35/-35 Installation Instructions Other, R-PG35 FL17676 R1 II 08-02269 513015.odf Verified By: Luis R. Lomas,PE PE-62514 Created by Independent Third Party:Yes Evaluation Reports http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvFGYZsjrZF... 11/10/2015 Florida Building Code Online Page 4 of 4 FL17676 R1 AE 513015 3540 FIs 52x62 pdf Created by Independent Third Party: Yes 17676.13 3540 SH 52x72 Finless Frame Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17676 R1 C CAC APC 3540 FLS 52x72 Ddf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 04/12/2017 Design Pressure:+30/-30 Installation Instructions Other: R-PG30 FL17676 RI II 08-02270 513016 Ddf Verified By: Luis R Lomas,PE PE-62514 Created by Independent Third Party:Yes Evaluation Reports FL17676 R1 AE 513016 3540 FIs 52x72.[)d Created by Independent Third Party:Yes 17676.14 3540 SH 52x84 Finless Frame Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL17676 R1 C CAC APC 3540 FLS 52x84 odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 05/26/2020 Design Pressure:+25/-25 Installation Instructions Other: R-PG25 FL17676 R1 II 08-01514 512141.1)df Verified By: Luis R Lomas,PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL17676 R1 AE 512141 3540 Flc 52x84.124 Created by Independent Third Party:Yes 17676.15 3540 SH 48x72 Fin Frame Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17676 R1 C CAC APC(12775)A2726.01-109-47- Approved for use outside HVHZ:Yes R2 C7326.01 3540 AWS IG FIN 48X72 R3 (072016) Impact Resistant:No Rev.pdf Design Pressure:+35/-35 Quality Assurance Contract Expiration Date Other: R-PG35. Units must be glazed in accordance with 07/20/2016 ASTM E1300-04. Installation Instructions FL17676 R1 II Install Instructs-3540 SH FIN 48x72(As Tested).pdf Verified By:American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 17676.16 3540 Triple SH 108x74 Fin Frame Triple CHS Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17676 RI C CAC APC 3540 CHS Fin 108x74 odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 04/12/2017 Design Pressure: +35/-50 Installation Instructions Other: LC-PG35.Units must be glazed in accordance with FL17676 R1 II Install-3540 SH CHS Fin 108x74 Ddf ASTM E1300-04. Verified By:American Architectural Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Back Next Contact Us::1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AAIEEO employer.Convrioht 2007-2013 State of Florida ::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ® � cChect M sccurity.m ETtucr http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvF GYZsj rZF... 11/10/2015 AAMA (Validator/Operations Administrator) CERTIFICATION PROGRAM AUTHORIZATION FOR PRODUCT CERTIFICATION MI Windows&Doors,LLC P.O.Box 370 Gratz,PA 17030-0370 Attn: Rick Sawdey The product described below is hereby approved for listing in the next issue of the AAMA Certified Products Directory. The approval is based on successful completion of tests,and the reporting to the Administrator of the results of tests,accompanied by related drawings, by an AAMA Accredited Laboratory. 1.The listing below will be added to the next published AAMA Certified Products Directory. SPECIFICATION AAMAIWDMA/CSA 101/I.S.2/A440-08 RECORD OF PRODUCT TESTED LC-PG35"-911x1867(36x74)-H Negative Design Pressure=-50 psf COMPANY AND CODE CPD NO. SERIES MODEL&PRODUCT MAXIMUM SIZE TESTED DESCRIPTION MI Windows&Doors,LLC 3540 SH(FIN) FRAME SASH Code:MTL 11355 (PVC)(O/X)(IG)(INS GL) 911 mm x 1867 mm 860 mm x 919 mm (REINF)(TILT)(ASTM) (3'0"x 6'2") (2'10"x 3'0") 2.This Certification will expire April 12,2017 and requires validation until then by continued listing in the current AAMA Certified Products Directory. 3. Product Tested and Reported by: Architectural Testing,Inc. Report No.: C7327.01-109-47 Date of Report: May 7,2013 Validated for Certification h, 4-;U- Adoci +tedLalboratories, Inc. Date: September 3,2013 Authorized for Certification Cc: AAMA JGS , ACP-04 (Rev.1/11) American Architectural Manufacturers Association ELEVATION Notes: 36" HEAD DETAIL 2" typ 1. Installation depicted cted based off of structural 12" O.C. test report #C7327.01-109-47. max. SHEATHING/OSB 2. Wood screws shall satisfy the National 2" typ. SIZE HEADER AS NEEDED Design Specification for Wood FLASHING Construction for material type and CAULK UNDER NAILING dimensional re uirements. BY OTHERS FIN ENURE PERIMETER Max. q 12" / BEFORE FASTENING. 3. Wood buck installations are assumed 2x / S-P-F (G=0.42) or denser. Buck width Anchor shall be greater than the window frame width. Tapered or partial width bucks (See Sectlon Details) are not allowed. Wood buck shall be secured to the structure to resist all design loads. DO i;O Q4. Wood screw lengths shall be sufficient MINIMUM to guarantee 1-1/4" penetration into 1/4 n o PENETR TION wood buck. INTO STUD 5. Maximum shim thickness of 1/4" permitted at each fastener location. Shims shall be load bearing, non- compressible type. / 6. These drawings depict the details necessary to meet structural load / requirements. They do not address the r Min Edge 7/16" air infiltration, water penetration, intrusion + SHIM AS or thermal performance requirements of EITREQUIRED the installation. DRYWALL 7. Installation shown is that of the test window for the size shown and the design pressure claimed. For window sizes smaller than shown, locate #8 X 1-5/8" SCREW (SHOWN WITH SHEATHING) fasteners approx. 2" from comers and no MUST ACHIEVE 1-1/4" PENETRATION more than 12" on center. Design INTO STUD.s 9 pressures of smaller window sizes are J't13�CLEARANCE limited to that of the test window. (ALL FOUR SIDES) SILL DETAIL 0 SIZE AND DESIGN PRESSURE CHART 131 FASTENER TYPE AND SPACING SHOWN WILL ALLOW DESIGN PRESSURES UP TO +35/ -50 UNITS UP TO 36" x 74" SHEATHING (SEE TEST REPORTS FOR INDIVIDUAL UNIT SIZE AND APPLICABLE DESIGN PRESSURE LIMITATIONS) U Min Edge 7/16" M■■ mom: �w+� DAM ■■ INSTALLATION INSTRUCTIONS V. 12-14-09 — & FASTENER SCHEDULE FIN— '� DAM Q JAMB DETAIL °"°° �C'NAIL FIN' IS A GENERIC TERM WHICH Windows&Doors 3540 Single Hung NONE 1 „1 MEANS MOUNTING FLANGE'. Gratz, PA cwa 7 �v (NOT TO BE CONFUSED WITH '1/2' FRONT FLANGE) 3540-3 40 SH FIN -