HomeMy WebLinkAboutProduct Approval (3) Florida Building Code Online Page 1 of 4
fit
Florida Departmentof BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts i Publications# FBC Staff BCIS 1Site Map Links Search
Busines@USER:Professinal Product Approval
Public User
Regulation �
Product Approval Menu>Product or Application Search>Application List>Application Det c
FL# FL17676-R1 4W jr
Application Type Revision
Code Version 2014
Application Status Approved
*Approved by DBPR.Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer MI Windows and Doors
Address/Phone/Email 650 West Market Street
Gratz,PA 17030
(717)365-3300 Ext 2560
bsitlinger@miwd.com
Authorized Signature Brent Sitlinger
bsitlinger@miwd.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Windows
Subcategory Single Hung
Compliance Method Certification Mark or Listing
Certification Agency American Architectural Manufacturers Association
Validated By Steven M. Urich,PE
® Validation Checklist-Hardcopy Received
Referenced Standard and Year(of Standard) Standard Year
AAMA/WDMA/CSA 101/I.S.2/A440 2008
Equivalence of Product Standards
Certified By
Product Approval Method Method 1 Option A
Date Submitted 07/14/2015
Date Validated 07/14/2015
Date Pending FBC Approval
Date Approved 07/23/2015
http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvFGYZsjrZF... 11/10/2015
Florida Building Code Online Page 2 of 4
Summary of Products
FL# Model,Number or Name Description
6755. .3540=SH. �
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:No FL17676 RI C CAC APC 3540 Fin 36x74 pdf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:No 04/12/2017
Design Pressure:+35/-50 Installation Instructions
Other: LC-PG35. Units must be glazed in accordance with FL17676 R1 II Install-3540 SH 36 x74 Fin odf
ASTM E1300-04. Verified By: American Architectural Manufacturers
Association
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
17676.2 3540 SH 36x84 Fin Frame
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:No FL17676 R1 C CAC APC 3540 Fin 36x84.pd
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: No 07/27/2020
Design Pressure:+40/-50 Installation Instructions
Other:LC-PG40. Units must be glazed in accordance with FL17676 R3 II Install-3540 SH Fin 36x84 odf
ASTM E1300-04. Verified By: American Architectural Manufacturers
Association
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
17676.3 3540 SH 40x66 Fin Frame
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL17676 R1 C CAC APC 3540 Fin 40x66 pdf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:No 08/26/2016
Design Pressure: +35/-45 Installation Instructions
Other: R-PG35. Units must be glazed in accordance with FL17676 R1 II Install-3540 SH Fin 40x66 odf
ASTM E1300-04. Verified By: American Architectural Manufacturers
Association
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
17676.4 3540 SH 44x63 Fin Frame
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:No FL17676 R1 C CAC APC 3540 Fin 44x63.pd
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:No 05/26/2020
Design Pressure: +40/-47 Installation Instructions
Other: R-PG40. Units must be glazed in accordance with FL17676 R1 II Install-3540 SH Fin 44x63 odf
ASTM E1300-04. Verified By: American Architectural Manufacturers
Association
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
17676.5 3540 SH 44x72 Fin Frame
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:No FL17676 RS C CAC APC 3540 Fn 44x72.pdf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:No 08/01/2017
Design Pressure:+35/-47 Installation Instructions
Other:R-PG35. Units must be glazed in accordance with FL17676 R1 II Install-3540 SH Fin 44x72.odf
ASTM E1300-04. Verified By:American Architectural Manufacturers
Association
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
17676.6 3540 SH 44x84 Fin Frame
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:No FL17676 R1 C CAC APC 3540 Fin 44x84.odf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:No 04/12/2017
Design Pressure: +30/-30 Installation Instructions
Other:LC-PG30. Units must be glazed in accordance with FL17676 R1 II Install-3540 SH Fin 44x84.odf
ASTM E1300-04. Verified By: American Architectural Manufacturers
Association
Created by Independent Third Party:
http://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgvFGYZsjrZF... 11/10/2015
Florida Building Code Online Page 3 of 4
Evaluation Reports
Created by Independent Third Party:
17676.7 3540 SH 52x84 Fin Frame
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:No FL17676 R1 C CAC APC 3540 Fin 2x84 pdf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:No 05/26/2020
Design Pressure: +25/-25 Installation Instructions
Other: R-PG25. Units must be glazed in accordance with FL17676 R1 II Install-3540 SH Fin 52x84 odf
ASTM E1300-04. Verified By: American Architectural Manufacturers
Association
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
17676.8 3540 SH 36x74 Finless Frame
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL17676 R1 C CAC APC 3540 FLS 36x74 odf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:No 08/28/2017
Design Pressure:+35/-50 Installation Instructions
Other:LC-PG35 FL17676 R1 II 08-01252A 511854A odf
Verified By: Luis R. Lomas,PE PE-62514
Created by Independent Third Party:Yes
Evaluation Reports
FL17676 R1 AE 511854A 3540 Fls 36x74.pdf
Created by Independent Third Party: Yes
17676.9 3540 SH 36x84 Finless Frame
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL17676 R1 C CAC APC 3540 FLS 36x84 odf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:No 07/27/2020
Design Pressure: +40/-50 Installation Instructions
Other: LC-PG40 FL17676 R1 II 08-01372 511989.odf
Verified By: Luis R. Lomas,PE PE-62514
Created by Independent Third Party: Yes
Evaluation Reports
FL17676 R1 AE 511989 3540 FLS 36x84,pd
Created by Independent Third Party:Yes
17676.10 3540 SH 44x72 Finless Frame
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:No FL17676 R1 C CAC APC 3540 FLS 44x72 odf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:No 08/28/2017
Design Pressure: +35/-47 Installation Instructions
Other:LC-PG35 FL17676 R1 II 08-01247A 511849A.odf
Verified By: Luis R. Lomas,PE PE-62514
Created by Independent Third Party: Yes
Evaluation Reports
FL17676 R1 AE 511849A 3540 FIs 44x72.pdf
Created by Independent Third Party:Yes
17676.11 3540 SH 48x96 Finless Frame
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:No FL17676 R1 C CAC APC 3540 FLS 48x96.pd
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:No 08/28/2017
Design Pressure: +30/-30 Installation Instructions
Other: LC-PG30 FL17676 R1 II 08-01371A 511988A.Ddf
Verified By: Luis R Lomas,PE PE-62514
Created by Independent Third Party:Yes
Evaluation Reports
FL17676 R1 AE 511988A 3540 FLS 48x96.pdf
Created by Independent Third Party:Yes
17676.12 3540 SH 52x62 Finless Frame
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:No FL17676 R1 C CAC APC 3540 FLS 52x62.odf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:No 08/27/2017
Design Pressure: +35/-35 Installation Instructions
Other, R-PG35 FL17676 R1 II 08-02269 513015.odf
Verified By: Luis R. Lomas,PE PE-62514
Created by Independent Third Party:Yes
Evaluation Reports
http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvFGYZsjrZF... 11/10/2015
Florida Building Code Online Page 4 of 4
FL17676 R1 AE 513015 3540 FIs 52x62 pdf
Created by Independent Third Party: Yes
17676.13 3540 SH 52x72 Finless Frame
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL17676 R1 C CAC APC 3540 FLS 52x72 Ddf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:No 04/12/2017
Design Pressure:+30/-30 Installation Instructions
Other: R-PG30 FL17676 RI II 08-02270 513016 Ddf
Verified By: Luis R Lomas,PE PE-62514
Created by Independent Third Party:Yes
Evaluation Reports
FL17676 R1 AE 513016 3540 FIs 52x72.[)d
Created by Independent Third Party:Yes
17676.14 3540 SH 52x84 Finless Frame
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:No FL17676 R1 C CAC APC 3540 FLS 52x84 odf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: No 05/26/2020
Design Pressure:+25/-25 Installation Instructions
Other: R-PG25 FL17676 R1 II 08-01514 512141.1)df
Verified By: Luis R Lomas,PE PE-62514
Created by Independent Third Party: Yes
Evaluation Reports
FL17676 R1 AE 512141 3540 Flc 52x84.124
Created by Independent Third Party:Yes
17676.15 3540 SH 48x72 Fin Frame
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL17676 R1 C CAC APC(12775)A2726.01-109-47-
Approved for use outside HVHZ:Yes R2 C7326.01 3540 AWS IG FIN 48X72 R3 (072016)
Impact Resistant:No Rev.pdf
Design Pressure:+35/-35 Quality Assurance Contract Expiration Date
Other: R-PG35. Units must be glazed in accordance with 07/20/2016
ASTM E1300-04. Installation Instructions
FL17676 R1 II Install Instructs-3540 SH FIN 48x72(As
Tested).pdf
Verified By:American Architectural Manufacturers
Association
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
17676.16 3540 Triple SH 108x74 Fin Frame Triple CHS
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL17676 RI C CAC APC 3540 CHS Fin 108x74 odf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:No 04/12/2017
Design Pressure: +35/-50 Installation Instructions
Other: LC-PG35.Units must be glazed in accordance with FL17676 R1 II Install-3540 SH CHS Fin 108x74 Ddf
ASTM E1300-04. Verified By:American Architectural Manufacturers
Association
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
Back Next
Contact Us::1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AAIEEO employer.Convrioht 2007-2013 State of Florida ::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts:
® � cChect M
sccurity.m ETtucr
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvF GYZsj rZF... 11/10/2015
AAMA
(Validator/Operations Administrator) CERTIFICATION PROGRAM
AUTHORIZATION FOR PRODUCT CERTIFICATION
MI Windows&Doors,LLC
P.O.Box 370
Gratz,PA 17030-0370
Attn: Rick Sawdey
The product described below is hereby approved for listing in the next issue of the AAMA Certified Products Directory. The approval
is based on successful completion of tests,and the reporting to the Administrator of the results of tests,accompanied by related drawings,
by an AAMA Accredited Laboratory.
1.The listing below will be added to the next published AAMA Certified Products Directory.
SPECIFICATION
AAMAIWDMA/CSA 101/I.S.2/A440-08 RECORD OF PRODUCT TESTED
LC-PG35"-911x1867(36x74)-H
Negative Design Pressure=-50 psf
COMPANY AND CODE CPD NO. SERIES MODEL&PRODUCT MAXIMUM SIZE TESTED
DESCRIPTION
MI Windows&Doors,LLC 3540 SH(FIN) FRAME SASH
Code:MTL 11355 (PVC)(O/X)(IG)(INS GL) 911 mm x 1867 mm 860 mm x 919 mm
(REINF)(TILT)(ASTM) (3'0"x 6'2") (2'10"x 3'0")
2.This Certification will expire April 12,2017 and requires validation until then by continued listing in the current AAMA Certified
Products Directory.
3. Product Tested and Reported by: Architectural Testing,Inc.
Report No.: C7327.01-109-47
Date of Report: May 7,2013
Validated for Certification
h,
4-;U-
Adoci +tedLalboratories, Inc.
Date: September 3,2013 Authorized for Certification
Cc: AAMA
JGS ,
ACP-04 (Rev.1/11)
American Architectural Manufacturers Association
ELEVATION
Notes:
36" HEAD DETAIL
2" typ 1. Installation depicted cted based off of structural
12" O.C. test report #C7327.01-109-47.
max. SHEATHING/OSB
2. Wood screws shall satisfy the National
2" typ. SIZE HEADER AS NEEDED Design Specification for Wood
FLASHING Construction for material type and
CAULK UNDER NAILING dimensional re uirements.
BY OTHERS FIN ENURE PERIMETER
Max. q
12" / BEFORE FASTENING. 3. Wood buck installations are assumed 2x
/
S-P-F (G=0.42) or denser. Buck width
Anchor shall be greater than the window frame
width. Tapered or partial width bucks
(See Sectlon Details) are not allowed. Wood buck shall be
secured to the structure to resist all
design loads.
DO i;O
Q4. Wood screw lengths shall be sufficient
MINIMUM to guarantee 1-1/4" penetration into
1/4 n o PENETR TION wood buck.
INTO STUD
5. Maximum shim thickness of 1/4"
permitted at each fastener location.
Shims shall be load bearing, non-
compressible type.
/ 6. These drawings depict the details
necessary to meet structural load
/ requirements. They do not address the
r Min Edge 7/16" air infiltration, water penetration, intrusion
+ SHIM AS or thermal performance requirements of
EITREQUIRED the installation.
DRYWALL 7. Installation shown is that of the test
window for the size shown and the
design pressure claimed. For window
sizes smaller than shown, locate
#8 X 1-5/8" SCREW (SHOWN WITH SHEATHING) fasteners approx. 2" from comers and no
MUST ACHIEVE 1-1/4" PENETRATION more than 12" on center. Design
INTO STUD.s 9
pressures of smaller window sizes are
J't13�CLEARANCE limited to that of the test window.
(ALL FOUR SIDES) SILL DETAIL
0
SIZE AND DESIGN PRESSURE CHART
131
FASTENER TYPE AND SPACING SHOWN WILL ALLOW DESIGN PRESSURES UP TO +35/ -50 UNITS UP TO 36" x 74"
SHEATHING (SEE TEST REPORTS FOR INDIVIDUAL UNIT SIZE AND APPLICABLE DESIGN PRESSURE LIMITATIONS)
U Min Edge 7/16" M■■ mom: �w+� DAM
■■ INSTALLATION INSTRUCTIONS V.
12-14-09
—
& FASTENER SCHEDULE FIN— '� DAM
Q JAMB DETAIL °"°°
�C'NAIL FIN' IS A GENERIC TERM WHICH Windows&Doors 3540 Single Hung NONE 1 „1
MEANS MOUNTING FLANGE'. Gratz, PA cwa 7 �v
(NOT TO BE CONFUSED WITH '1/2' FRONT FLANGE) 3540-3 40 SH FIN -