Loading...
HomeMy WebLinkAboutProduct Approval (4) Florida Building Code Online Page 1 of 4 RECEIVED NOV 415 k" Florida Depaamentq BCIS Home *Log In User Registration Hot Topics Submit Surcharge Stats&Facts i Publications FBC Staff , BCIS Site Map Links �w Search Business Professibl a'l (AUSER:Prod uct PubliccUpseroval Regulation I Y1�LiiYl1'�11 � Product Approval Menu>Product or Application Search>Aoolication List>Application Detail f to FL# FL17499 Application Type New Code Version 2014 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived C Product Manufacturer MI Windows and Doors Address/Phone/Email 650 West Market Street Gratz, PA 17030 (717)365-3300 Ext 2560 bsitlinger@miwd.com Authorized Signature Brent Sitlinger bsitlinger@miwd.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Single Hung Compliance Method Certification Mark or Listing Certification Agency American Architectural Manufacturers Association Validated By Steven M. Urich,PE Lid Validation Checklist-Hardcopy Received Referenced Standard and Year(of Standard) Standard Year AAMA 506 2008 AAMA/WDMA/CSA 101/I.S.2/A440 2008 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 02/18/2015 Date Validated 02/18/2015 Date Pending FBC Approval Date Approved 02/21/2015 http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtCUGgvj Qiz6... 11/10/2015 Florida Building Code Online Page 2 of 4 Summary of Products FL# Model,Number or Name Description 1� 9Q: -185--SH,,`�,aY 52x7L/Flange=Frame_IG/SG_Impact Sln:gle_HuOg Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL17499 RO C CAC MI Windows- 185 SH (Fin)Impa Approved for use outside HVHZ:Yes (2).ndf Impact Resistant:Yes FL17499 RO C CAC MI Windows-185 SH(Fin)Impact 'Design Pressure: +55/-55 3 . df Other: R-PG55,Missile Level D,Wind Zone 3.Glass to be FL17499 RO C CAC MI Windows- 185 SH(Flange)Impact bedded in Pecora 896 sealant. (2).Ddf FL17499 RO C CAC MI Windows-185 SH(Flange)Impact S . df Quality Assurance Contract Expiration Date 10/10/2018 Installation Instructions FL17499 RO II 08-02544.pdf Verified By: Luis R Lomas PE 62514 Created by�Independent Third Party:Yes Evaluation Reports FL17499 RO AE E1726 O1-02 Impact 513320 08-2544 pdf Created by Independent Third Party:Yes 17499.2 185 SH 52x84 Fin/Flange Frame IG/SG Single Hung Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL17499 RO C CAC APC(13362)E1725 01-109-47-RO 18 Approved for use outside HVHZ:Yes SH(FLG waiver)5-8IG 1-8A 52 1-8X84 R60(100918)pdf Impact Resistant:No FL17499 RO C CAC MI Windows- 185 SH(Fin)(10)_pdf Design Pressure: +60/-60 FL17499 RO C CAC MI Windows-18S SH(Fin)(9)pdf Other: R-PG55 FL17499 RO C CAC MI Windows- 185 SH(Flangg)(91 pdf Quality Assurance Contract Expiration Date 10/09/2018 Installation Instructions FL17499 RO II 08-02546.Ddf Verified By: Luis R Lomas PE 62514 Created by Independent Third Party: Yes Evaluation Reports FL17499 RO AE E1725-E1730 Non Impact 513322 08- 2546.12df Created by Independent Third Party:Yes 17499.3 185 SH 36x84 Fin/Flange Frame IG/SG Impact Single Hung Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL17499 RO C CAC MI Windows-185 SH(Fin)Impac Approved for use outside HVHZ:Yes (4).Ddf Impact Resistant:Yes FL17499 RO C CAC MI Windows-185 SH(Fin)Impact(5) Design Pressure: +55/-55 Done.pdf Other: R-PG55*,Missile Level D,Wind Zone 3.Glass to be FL17499 RO C CAC MI Windows-185 SH(Flange)Impact bedded in Pecora 896 sealant. (3).pdf FL17499 RO C CAC MI Windows- 185 SH(Flange)Impact 4 . df Quality Assurance Contract Expiration Date 10/17/2018 Installation Instructions FL17499 RO II 08-02545.pdf Verified By: Luis R Lomas PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL17499 RO AE E1729.01-.02 Impact 513321 08-2545.})df Created by Independent Third Party: Yes 17499.4 185 SH 52x72 Fin/Flange Frame IG/SG Single Hung Laminated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL17499 RO C CAC APC(13361)E1726 01-109-47-RO 185 Approved for use outside HVHZ:Yes SH(FLG waiver).pdf Impact Resistant:No FL17499 RO C CAC MI Windows-185 SH(Fin)(11).ndf Design Pressure:+60/-60 FL17499 RO C CAC MI Windows- 185 SH(Fin)(12).Ddf Other:R-PG60 FL17499 RO C CAC MI Windows- 185 SH(Flange) SO .ndf Quality Assurance Contract Expiration Date 10/08/2018 Installation Instructions FL17499 RO II 08-02549.pdf Verified By: Luis R Lomas PE-62514 Created by Independent Third Party:Yes Evaluation Reports FL17499 RO AE E1726 Non Impact 513327 08-2549.pdf Created by Independent Third Party: Yes http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtCUGgvj Qiz6... 11/10/2015 Florida Building Code Online Page 3 of 4 17499.5 1185 SH 36x84 Fin/Flange Frame IG/SG Single Hung Laminated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL17499 RO C CAC APC(13363)E1729.01-109-47-RO 185 Approved for use outside HVHZ:Yes SH(FLG waiver).pdf Impact Resistant:No FL17499 RO C CAC MI Windows- 185 SH(Fin)(13)Ddf Design Pressure:+60/-60 FL17499 RO C CAC MI Windows-185 SH(Fin)(14).pdf Other: R-PG60* FL17499 RO C CAC MI Windows-185 SH(Flange) li df Quality Assurance Contract Expiration Date 10/17/2018 Installation Instructions FL17499 RO II 08-02550.pddf Verified By: Luis R Lomas PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL17499 RO AE E1729 Non Impact 513328 08-2550 Ddf Created by Independent Third Party: Yes 17499.6 185 Triple SH 111x72 Fin Frame IG/SG Single Hung 11002 Flange Frame IG/SG Single Hung Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL17499 RO C CAC MI Windows-185 SH Triple(Fin) Approved for use outside HVHZ:Yes 3 . df Impact Resistant:No FL17499 RO C CAC MI Windows-185 SH Triple(Fin) Design Pressure:+50/-50 (4).Ddf Other: R-PG50* FL17499 RO C CAC MI Windows-185 SH Triple(Flange) (3).ndf FL17499 RO C CAC MI Windows-185 SH Triple(Flange) (4).pd! Quality Assurance Contract Expiration Date 10/20/2018 Installation Instructions FL17499 RO II 08-02548.Ddf Verified By: Luis R Lomas PE 62514 Created by Independent Third Party: Yes Evaluation Reports FL17499 RO AE E2134-37 Non Impact Triple 513324 08- 2548.Ddf Created by Independent Third Party:Yes 17499.7 185 Twin SH 10602 Fin Frame IG/SG Single Hung 10502 Flange Frame IG/SG Single Hung Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL17499 RO C CAC MI Windows-185 SH Twin(Fin) Approved for use outside HVHZ:Yes (3).pdf Impact Resistant:No FL17499 RO C CAC MI Windows-185 SH Twin(Fin) Design Pressure: +45/-45 (4).Ddf Other: R-PG45 FL17499 RO C CAC MI Windows-185 SH Twin(Flange) (3).Ddf FL17499 RO C CAC MI Windows-185 SH Twin(Flange) (4).odf Quality Assurance Contract Expiration Date 10/20/2018 Installation Instructions FL17499 RO II 08-02547.pdf Verified By: Luis R Lomas PE-62514 Created by Independent Third Party:Yes Evaluation Reports FL17499 RO AE E2134-37 Non Impact Twin 513323 08- 2547.Ddf Created by Independent Third Party:Yes Back Next Contact Us::1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: cCGe 4 M st`CUrit139F Rte.T http://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgtCUGgvj Qiz6... 11/10/2015 AAMA (Validator/Operations Administrator) CERTIFICATION PROGRAM AUTHORIZATION FOR PRODUCT CERTIFICATION MI Windows&Doors,LLC P.O.Box 370 Gratz,PA 17030-0370 Attn: Rick Sawdey The product described below is hereby approved for listing in the next issue of the AAMA Certified Products Directory. The approval is based successful completion of tests,and the reporting to the Administrator of the results of tests,accompanied by related drawings,by an AAMA Accredited Laboratory. 1.The listing below will be added to the next published AAMA Certified Products Directory. SPECIFICATIONS RECORD OF PRODUCT TESTED AAMA/WDMA/CSA 101/I.S.2/A440-08 HAMA 506 R-PG55-1324x1819(52x72)-H COMPANY AND CODE Missile Level:D CPD SERIES MODEL& MAXIMUM SIZE TESTED Rating:+55/-55,52x72 NO. PRODUCT DESCRIPTION Wind Zone:3 Rating above conforms 185 SH(FIN) FRAME(mm) SASH(mm) MI Windows&Doors,LLC to the requirements of: 13275 (AL)(O/X)(OG) 1324 x 1819 1295 x 914 Code:MTL ASTM E1886 (PVB LAM GL)(ASTM) (4'4"x 6'0") (4'3"x 3'0") and E1996 2.This Certification will expire October 10,2018 and requires validation until then by continued listing in the current AAMA Certified Products Directory. 3.Structural Test&Report By: Missile Impact Test&Report By: Architectural Testing,Inc. Architectural Testing,Inc. Report No: E1726.01-109-47 Report No: E1726.02-109-47 Date of Report: October 31,2014 Date of Report: October 31,2014 Validated for Certification h, 4aL Aoci ted Laboratories, Inc. Date: November 4,2014(Revised November 10,2014) Authorized for Certification Cc: AAMA D��" JGS ACP-14 (Rev. 1/11) America rchitectural Manufacturers Association AAMA (Validator/Operations Administrator) CERTIFICATION PROGRAM AUTHORIZATION FOR PRODUCT CERTIFICATION MI Windows&Doors,LLC P.O.Box 370 Gratz,PA 17030-0370 Attn: Rick Sawdey The product described below is hereby approved for listing in the next issue of the AAMA Certified Products Directory. The approval is based successful completion of tests,and the reporting to the Administrator of the results of tests,accompanied by related drawings,by an AAMA Accredited Laboratory. 1.The listing below will be added to the next published AAMA Certified Products Directory. SPECIFICATIONS RECORD OF PRODUCT TESTED AAMA/WDMA/CSA 101/i.S.2/A440-08 HAMA 506 R-PG55-1324x1819(52x72)-H COMPANY AND CODE Missile Level:D CPD SERIES MODEL& MAXIMUM SIZE TESTED Rating:+55/-55,52x72 NO. PRODUCT DESCRIPTION Wind Zone:3 Rating above conforms 185 SH(FIN) FRAME(mm) SASH(mm) MI Windows&Doors,LLC to the requirements of: (AL)(O/X)(OG) 13276 1324 x 1819 1295 x 914 Code:MTL ASTM E1886 (INS PVB LAM GL) (4'4"x 6'0") (4'3"x 3'0") and E1996 (ASTM) 2.This Certification will expire October 10,2018 and requires validation until then by continued listing in-the current AAMA Certified Products Directory. 3.Structural Test&Report By: Missile Impact Test&Report By: Architectural Testing,Inc. Architectural Testing,Inc. Report No: E1726.01-109-47 Report No: E1726.02-109-47 Date of Report: October 31,2014 Date of Report: October 31,2014 Validated for Certification Aoci ted Laboratories, Inc. Date: November 4,2014(Revised November 10,2014) Authorized for Certification Cc: AAMA =_" JGS ACP-14 (Rev. 1/11) AmericYn Architectural Manufacturers Association AAMA (Validator/Operations Administrator) CERTIFICATION PROGRAM AUTHORIZATION FOR PRODUCT CERTIFICATION MI Windows&Doors,LLC P.O.Box 370 Gratz,PA 17030-0370 Attn: Rick Sawdey The product described below is hereby approved for listing in the next issue of the AAMA Certified Products Directory. The approval is based successful completion of tests,and the reporting to the Administrator of the results of tests,accompanied by related drawings,by an AAMA Accredited Laboratory. 1.The listing below will be added to the next published AAMA Certified Products Directory. SPECIFICATIONS RECORD OF PRODUCT TESTED AAMAIWDMA/CSA 101/I.S.2/A440-08 HAMA 506 R-PG55-1324x1819(52x72)-H COMPANY AND CODE Missile Level:D CPD SERIES MODEL& MAXIMUM SIZE TESTED Rating:+55/-55,52x72 NO. PRODUCT DESCRIPTION Wind Zone:3 Rating above'conforms 185 SH(FLANGE) FRAME(mm) SASH(mm) MI Windows&Doors,LLC to the requirements of. 13277 (AL)(O/X)(OG) 1324 x 1819 1295 x 914 Code:MTL ASTM E1886 (PVB LAM GL)(ASTM) (4'4"x 6'0") (4'3"x 3'0") and E1996 2.This Certification will expire October 10,2018 and requires validation until then by continued listing in the current AAMA Certified Products Directory. 3.Structural Test&Report By: Missile Impact Test&Report By: Architectural Testing,Inc. Architectural Testing,Inc. Report No: E1726.01-109-47 Report No: E1726.02-109-47 Date of Report: October 31,2014 Date of Report: October 31,2014 Validated for Certification 'hl 4aL Aoci ted Laboratories, Inc. Date: November 4,2014(Revised November 10,2014) Authorized for Certification Cc: AAMA D��" JGS ACP-14 (Rev. 1/11) Americ Architectural Manufacturers Association 1` AAMA (Validator/Operations Administrator) CERTIFICATION PROGRAM AUTHORIZATION FOR PRODUCT CERTIFICATION MI Windows&Doors,LLC P.O.Box 370 Gratz,PA 17030-0370 Attn: Rick Sawdey The product described below is hereby approved for listing in the next issue of the AAMA Certified Products Directory. The approval is based successful completion of tests,and the reporting to the Administrator of the results of tests,accompanied by related drawings,by an AAMA Accredited Laboratory. 1.The listing below will be added to the next published AAMA Certified Products Directory. SPECIFICATIONS RECORD OF PRODUCT TESTED AAMAMDMA/CSA 101/I.S.2/A440-08 HAMA 506 R-PG55-1324x1819(52x72)-H COMPANY AND CODE Missile Level:D CPD SERIES MODEL& MAXIMUM SIZE TESTED Rating:+55/-55,52x72 NO. PRODUCT DESCRIPTION Wind Zone:3 Rating above conforms 185 SH(FLANGE) FRAME(mm) SASH(mm) MI Windows&Doors,LLC to the requirements of: 13291 (AL)(O/X)(OG) Code:MTL ASTM E1886 (INS PVB LAM GL) 1324 x 1819 x 914 and E1996 (ASTM) (4'4"x 6'0") (44''33""x 3'0") 2.This Certification will expire October 10,2018 and requires validation until then by continued listing in the current AAMA Certified Products Directory. 3.Structural Test&Report By: Missile Impact Test&Report By: Architectural Testing,Inc. Architectural Testing,Inc. Report No: E1726.01-109-47 Report No: E1726.02-109-47 Date of Report: October 31,2014 Date of Report: October 31,2014 Validated for Certification Aoci ted Laboratories, Inc. Date: November 10,2014 Authorized for Certification Cc: AAMA D��Vz� JGS ACPA4 (Rev.1/11) Ameri nArchitecturalManufacturersAssociation REVISIONS REV DESCRIPTION DATE APPROVED NOTES: 15. FOR ANCHORING INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH SUFFICIENT LENGTH 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE REQUIREMENTS OF THE FLORIDA BUILDING CODE. DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY 16. FOR ANCHORING INTO METAL STRUCTURE USE #8 SMS OR SELF DRILLING SCREWS WITH TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. 17. ALL FASTENERS TO BE CORROSION RESISTANT. 4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE 18. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. A. WOOD — MINIMUM SPECIFIC GRAVITY OF G=0.42 5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY B. CONCRETE — MINIMUM COMPRESSIVE STRENGTH OF 3,192 PSI. FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY C. MASONRY — STRENGTH CONFORMANCE TO ASTM C-90, GRADE N, TYPE 1 (OR GREATER). BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH D. METAL STRUCTURE: STEEL 18GA, 33KSI OR ALUMINUM 6063—T5 1/8" THICK MINIMUM MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. 6. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. 8. FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME INSTALLATION SHIM AS REQUIRED AT EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". 9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS. 10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 11. FRAME MATERIAL: ALUMINUM 6063—T5. 12. UNITS MUST BE GLAZED PER ASTM E1300-04, SEE SHEET 2 FOR GLASS OPTIONS. 13. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 14. FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #8 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. SIGNED: 12/17/2014 M650IWDOWESTMA KETS DSDOORS 5\RIILO/ TABLE OF CONTENTS GRATZ, PA 17030-0370 .��pENS�9��i� SHEET NO. DESCRIPTION SERIES 185 ALUMINUM SINGLE HUNG WINDOW _*�•//�;U�o 51 1 NOTES 52"X7LMI NOTES �qs• TAT OF04 2 ELEVATIONS & GLASS OPTIONS- DRAWN: DWG NO. REI %�'OFS'�CpIj�OQ;G`�'�\� 4 — 7 INSTALLATION DETAILS scA E DATE 08-02544 — ///S/ONA;1S�'\?l 8 COMPONENTS NTS 12/09/14 1 OF 8 REVISIONS 52" MAX FRAME WIDTH 52" MAX FRAME WIDTH REV DESCRIPTION DATE APPROVED 11 11 2" MAX MAX10.C. 2" MAX 2" MAX MAXOO.C. 2" MAX CHART#1 Number of anchor locations required Frame Frame Width(in) 2" MAX Height 78.00 24.00 30.00 36.00 42.00 48.00 52.00 / 2" MAX (in) Head Jamb Head Jamb Head Jamb Head Jamb Head Jamb Head I Jamb Head Jamb / 24.00 3 3 3 3 4 3 4 3 5 3 5 1 3 6 3 " 30.00 3 4 3 4 4 4 4 4 5 4 5 4 6 4 11 MAX O.C. / O / O 36.00 3 4 3 4 4 4 4 4 5 4 5 4 6 4 T / 42.00 3 5 3 5 4 5 4 5 5 5 5 5 6 5 } 10" MAX / 48.00 3 5 3 5 4 5 4 5 5 5 5 5 6 5 O.C. 54.00 3 6 3 6 4 6 4 6 5 6 5 6 6 6 72" 60.00 3 7 3 7 4 7 4 7 5 7 5 7 6 7 MAX 72 -� 66.00 3 7 3 7 4 7 4 7 5 7 5 7 6 7 FRAME MAX 72.00 1 3 1 8 3 8 1 4 1 8 1 4 8 5 1 8 1 5 8 6 8 FRAME HEIGHT HEIGHT Q n / CHART#2 / / ILJI Number of anchor locations required Frame Frame Width(in) X Height � 18.00 24.00 30.00 36.00 42.00 48.00 52.00 (in) H&S Jamb H&S Jamb H&S IJamb H&S Jamb H&S IJamb H&S Jamb H&S Jamb 2" MAX24.00 3 3 3 3 4 3 5 3 5 3 6 3 6 3 L r 2 MAX 30.00 3 4 3 4 4 4 5 4 5 4 6 4 6 4 136.00 3 5 3 5 4 5 5 5 5 5 6 5 6 5 42.00 3 5 3 5 4 5 5 5 5 5 6 5 6 5 185 ALUMINUM SINGLE HUNG WINDOW 185 ALUMINUM SINGLE HUNG WINDOW 48.00 3 6 3 6 4 6 5 6 5 6 6 66 6 EXTERIOR VIEW EXTERIOR VIEW 54.00 3 6 3 6 4 6 5 6 5 6 6 6 6 6 FLANGE&FINLESS INSTALLATION FININSTALLATION 60.00 3 7 3 7 4 7 5 7 5 7 6 7 6 7 SEE CHART#1 FOR SMALLER UNITS REQUIRED ANCHORS SEE CHART#2 FOR SMALLER UNITS REQUIRED ANCHORS 66.00 3 8 1 3 1 8 4 8 1 5 8 5 8 6 1 8 6 1 8 72.00 3 1 8 3 1 8 1 4 8 5 1 8 1 5 1 8 6 8 6 1 8 DESIGN PRESSURE RATING IMPACT RATING ±55.OPSF LARGE MISSILE IMPACT HARDWARE SCHEDULE MISSILE LEVEL D,WIND ZONE A, (2)METAL SWEEP LOCK AT 8"FROM EACH END INTERIOR MEETING RAIL B. (2)BLOCK AND TACKLE BALANCE AT IAMBS 5/8" NOTES: 1. MAXIMUM SASH SIZE: 51" X 36". 1/8" ANN. 1/8" ANN. 3/8" 2. MAXIMUM SASH D.L.O.: 47 5/8" X 32 1/2". 1/8" ANN. 1/8" ANN 2. MAXIMUM FIXED D.L.O.: 49 3/8" X 32 1/2". .090 PVB .090 PVB SIGNED: 12/17/2014 METAL REINFORCED 1/8" ANN. BUTYL SPACER MI WINDOWS AND DOORS .01,I111((1111f EXTERIOR EXTERIOR 650 WEST MARKET STREET ����5 R. Lp�/i�� J INTERIOR INTERIOR GRATZ, PA 17030-0370 �v•��GENS+�9�i�i� 1/2" BITE SILICONE SILICONE 1/2" BITE SERIES 185 ALUMINUM SINGLE HUNG WINDOW *�•/�1 py6}51 SEALANT SEALANT _ (,(fir 52"X72"- LMI ��y([�n \ ELEVATIONS & GLASS OPTIONS �� $TAT OF SETTING BLOCK SETTING BLOCK DRAWN: DWG NO. REV �i��'cF• Z P'• ORlO. . GLAZING DETAIL A GLAZING DETAIL 8 N.G.AATE G. 08-02544 8 s2 44 NTS 12/09/14 2 OF 8 1/2" MIN REVISIONS EDGE DISTANCE REV DESCRIPTION DATE APPROVED WOOD FRAMING 3/4" MIN OR 2X BUCK EDGE DISTANCE BY OTHERSYSHIM + METAL 1 1/4" MIN. 1/4" MAX. 1 1/4" MIN. STRUCTURE EMBEDMENT SHIM SPACE EMBEDMENT BY OTHERS 1/4" MAX. SHIM SPACE BACKER ROD � INTERIOR & APPROVEDMAX. F 1/2" MIN SEALANTPACE APPROVED EDGE DISTANCE SEALANT #8 WOOD SCREW #8 WOOD #8 SMS OR SCREW SELF DRILLING WOOD FRAMING EXTERIOR SCREW OR 2X BUCK BACKER ROD BY OTHERS & APPROVED SEALANT JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION INTERIOR EXTERIOR INTERIOR1/4" MAX. EXTERIOR SHIM SPACE #8 SMS OR INTERIOR SELF DRILLING SCREWS SILL TO BE SET T N A BED OF 3/4" MIN. APPROVED SILL TO BE SET EDGE DISTANCE STRUCTURAL IN A BED OF BACKER ROD SEALANT APPROVED & APPROVED STRUCTURAL EXTERIOR "SEALANT 1/4" MAX. BACKER ROD SEALANT METAL SHIM SPACE & APPROVED STRUCTURE BACKER ROD SEALANT 1/4" MAX. BY OTHERS & APPROVED WOOD FRAMING SHIM SPACE SEALANT OR 2X BUCK BY OTHERSMETAL STRUCTURE JAMB INSTALLATION DETAIL BY OTHERS METAL STRUCTURE INSTALLATION SIGNED: 12/17/2014 VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION VERTICAL CROSS SECTION MSGRA50 T�EST WINDOWS 1 AND SODOORS `vTREET J`s CES ��'// METAL STRUCTURE INSTALLATION NOTES: SERIES 185 ALUMINUM SINGLE HUNG WINDOW *4"TAT 0 52"X72"- LMI 51 *= _1.INTERIORANDEXTERIORFINISHES,BYOTHERS, OFNOT SHOWN FOR CLARITY. FLANGE INSTALLATION DETAILS �p• 2.DESIGNED PERIMETER ACCORDANCE AND JOINT SEALANT BY OTHERS T E 2S TO BE DRAWN: DWG N0. JR- %0'OFS'cI QR�OP 08-02544 ONAL V"G\\\�\ SCALE DATE 12/09/14 E3 OF 8 1/111111110 � 2 1/2" MIN. REVISIONS EDGE DISTANCE REV DESCRIPTION DATE APPROVED CONCRETE/MASONRY BY OTHERS a a ° ° OPTIONAL 1X BUCK ° °°' d 1 1/4" MIN. SEE NOTES 3 — 7 ° EMBEDMENT 1 1/4" MIN. SHEET 1 EMBEDMENT CONCRETE/MASONRY HIM MAX. 1/4" MAX. BY OTHERS SHIM SPACE BACKER ROD SHIM SPACE & APPROVED v SEALANT 3/16" TAPCON 3/16" TAPCON >a a INTERIOR EXTERIOR INTERIOR 2 1/2" ° MIN. EDGE a DISTANCE EXTERIOR BACKER ROD & APPROVED OPTIONAL 1X BUCK SEALANT SEE NOTES 3 — 7 SILL TO BE SET SHEET 1 JAMB INSTALLATION DETAIL BACKER ROD IN A BED OF CONCRETEIMASONRY INSTALLATION APPROVED & APPROVED SEALANT STRUCTURAL SEALANT OPTIONAL 1X BUCK " OTES: AM D,-- 14MAX.MAX SEE NOTE 3 — 7 / 1.INTERIOR AND EXTERIOR FINISHES,BY OTHERS, 71 SHEET 1 SHIM SPACE NOT SHOWN FOR CLARITY. 2.PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 CONCRETE/MASONRY BY OTHERS , ° ° SIGNED: 12/17/2014 a° ° ° a MI WINDOWS AND DOORS ����7111IUI��i . ° 650 WEST MARKET STREET `�\\J\s R' L..t' g a °` GRATZ, PA 17030-0370 `v•��GENs�9��G SERIES 185 ALUMINUM SINGLE HUNG WINDOW _*• 0y6�51 k= 52"X72"— LMI � ( � VERTICAL CROSS SECTION FLANGE INSTALLATION DETAILS i6.P•.F CONCRETE/MASONRYINSTALLATION NRAOwN: owc No. 08-02544 REv ��/�iS�s�OR10 SCALE NT$ DATE 12/09/14 SHE OF 8 1/2" MIN REVISIONS EDGE DISTANCE REV DESCRIPTION DATE APPROVED WOOD FRAMING 3/4" MIN OR 2X BUCK EDGE DISTANCE BY OTHERS > < METAL 1 1/4" MIN. 1/4" MAX. STRUCTURE EMBEDMENT SHIM SPACE BY OTHERS 1/4" MAX. SHIM SPACE -� INTERIOR BACKER ROD 1/4" MAX. & APPROVED SHIM SPACE � 1/2" MIN SEALANT APPROVED EDGE DISTANCE SEALANT #8 WOOD SCREW #8 WOOD SCREW #8 SMS OR EXTERIOR EXTERIOR SELF DRILLING WOOD FRAMING SCREW OR 2X BUCK BACKER ROD BY OTHERS & APPROVED INTERIOR SEALANT JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION EXTERIOR INTERIOR 1/4" MAX. SHIM SPACE #8 SMS OR INTERIOR SELF DRILLING SCREWS SILL TO BE SET IN A BED OF SILL TO BE SET 3/4" MIN. APPROVED IN A BED OF EDGE DISTANCE STRUCTURAL APPROVED BACKER ROD SEALANT STRUCTURAL EXTERIOR & APPROVED BACKER ROD SEALANT SEALANT 1/4" MAX. & APPROVED WOOD FRAMING SHIM SPACE SEALANT SHIM SPACE METAL BACKER ROD 1/4" MAX. STRUCTURE & APPROVED OR 2X BUCK BY OTHERS SEALANT BY OTHERS METAL STRUCTURE JAMB INSTALLATION DETAIL BY OTHERS METAL STRUCTURE INSTALLATION SIGNED: 12/17/2014 VERTICAL CROSS SECTION WOOD FRAMING OR2XBUCK INSTALLATION VERTICAL CROSS SECTION M650IWDSOTWMARKET DSTREET DOORS t/0 ///// METAL STRUCTURE INSTALLATION GRATZ, PA 17030-0370 `��•��CENS+�.'9sf�i� NOTES: SERIES 185 ALUMINUM SINGLE HUNG WINDOW _*• 0 51 7t= 1.INTERIOR AND EXTERIOR FINISHES,BY OTHERS, 52"X72"- LMI FINLESS INSTALLATION DETAILS r STAT OF NOT SHOWN FOR CLARITY. W z 2.PERIMETER AND JOINT SEALANT BY DESIGNED IN ACCORDANCE WITH ASTM E2E ZS TO BE DRAWN: Dwc NO. REV 'cFS.c� ISCALIE NTS DATE 12/09/14 08-02544S"EEr5OF 8 2 1/2" MIN*3/16" REVISIONS REV DESCRIPTION DATE APPROVED CONCRETE/MASONRYBY OTHERSOPTIONAL 1X BUCKc ° 1EMFOMENTSEE NOTES 3 — 7 1 1/4" MIN. SHEET 1 EMBEDMENT CONCRETE/MASONRY " MAX. BY OTHERS OPTIONAL 1X BUCK BACKER ROD SPACE SEE NOTES 3 — 7 & APPROVED °c SHEET 1 SEALANT TAPCON 3/16" TAPCON 1/4 " MX. E ° NTERIOR Irm EXTERIOR INTERIOR 2 1/2" ° MIN. v ° EDGE ° DISTANCE ° ° EXTERIOR J & APPROVED SEALANT SILL TO BE SET JAMB INSTALLATION DETAIL BACKER ROD IN A BED OF CONCRETEAMASONRY INSTALLATION APPROVED & APPROVED SEALANT STRUCTURAL SEALANT OPTIONAL 1X BUCK 1/4" MAX. NOTES: SEE NOTE 3 — 71.INTERIOR AND EXTERIOR FINISHES,BY OTHERS, SHIM SPACE NOT SHOWN FOR CLARITY. SHEET 1 2.PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 CONCRETE/MASONRY BY OTHERS ° .4A SIGNED: 12/17/2014 d MI WINDOWS AND DOORS 650 WEST MARKET STREET \����g R. Lpy/4�� a ° GRATZ, PA 17030-0370 `ter•��GENs�'9s�% SERIES 185 ALUMINUM SINGLE HUNG WINDOW =*• 0 51 •7t= 52"X72ALMI =•o ff` VERTICAL CROSS SECTION FINLESS INSTALLATION DETAILS �gf• TAT OF CONCRETE/MASONRY INSTALLATION DRAWN: DWG N0. REV 0. TAT :c[pR10P G��` SO E NTS DATE 12/09/14 OS sOEET640F 8 ////S'CIVA;1�����\ 1 1/4" MIN. REVISIONS EMBEDMENT REV DESCRIPTION DATE APPROVED #8 WOOD WOOD SCREW FRAMING BY OTHERS 1/4" MAX. SHIM SPACE 7/16" MIN EDGE DISTANCE WOOD FRAMING 1/4" MAX BY OTHERS SHIM SPACE INTERIOR 1 1 N. MIN. EXTERIOR EMBEDMENT INTERIOR #8 WOOD SCREW 7/16" MIN EDGE DISTANCE EXTERIOR JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION 1/4" MAX NOTES: SHIM SPACE 1.INTERIOR AND EXTERIOR FINISHES,BY OTHERS, NOT SHOWN FOR CLARITY. -� 2.PERIMETER AND JOINT SEALANT BY OTHERS TO BE 3/8" MIN DESIGNED IN ACCORDANCE WITHASTM E2112 EDGE DISTANCE #8 WOOD WOOD SCREW FRAMING SIGNED: 12/17/2014 1 1/4" MIN. BY OTHERS EMBEDMENT M650 INDOWEST MA KED SDOORS `TREET `\\J\S R I�LIp �/// VERTICAL CROSS SECTION GRATZ, PA 17030-0370 `�,••��GENs�.•S WOOD FRAMING OR 2X BUCK INSTALLATION SERIES 185 ALUMINUM SINGLE HUNG WINDOW =*• 0 51 •it= 52"X72"- LMI FIN INSTALLATION DETAILS �v0• TAT OF DRAWN: DWG N0. REV ��0��•'c(ORIOP. N.G. 08-02544 - ///SS%■ ••� \N SCALE NTS DATE 12/09/14 SHEET7 OF 8 /////OIlA11��\`\ REVISIONS 2 3/16" 1 7/8" 1 3/$'f-- REV DESCRIPTION DATE APPROVED 2 3/16" 13/16" 2 3/16" 2 3/16" T�j1 5/16" U -L-- FLANGE FRAME HEAD FLANGE FRAME JAMB FINLESS FRAME HEAD FINLESS FRAME JAMB CM-18501 CM-18503 CM-18553 CM-18513 ALUMINUM 6063-T5.050"THICK ALUMINUM 6063-T5.050"THICK ALUMINUM 6063-T5.050"THICK ALUMINUM 6063-T5.050"THICK 2 5/16" 2 5/16" - 2 5/16" 2 3/16" 2 3/8" 3 3/8" 2 13/1 E 3 3/4" 2 5/16" 2 3/16" 7rFLANGE FRAME SILL FINLESS FRAME SILL L J� CM-18502 CIVIL 18554 FIN FRAME SILL FIN FRAME HEAD FIN FRAME JAMB ALUMINUM 6063-T5.055"THICK ALUMINUM 6063-T5.055"THICK CM-18509 CM-18508 CM-18510 ALUMINUM 6063-T5.055"THICK ALUMINUM 6063-T5.050"THICK ALUMINUM 6063-T5.050"THICK 1 7/16" 1 5/8" � � 1 5/8" 1/8" 1 3/8'• 2 5/16" L_I I �I I-- 7/16 2" " 1, I I 15/16" SASH STILE CM-18507 LOCKRAIUSTILE 15/16" GLAZING BEAD SASH BOTTOM RAIL MEETING RAIL GLAZING BEAD ALUMINUM 6063-T5.050"THICK CM-18505 CM-18555 CM-18504 CM-18535 CM-18521 ALUMINUM 6063-T5.062"THICK ALUMINUM 6063-T5.050"THICK ALUMINUM 6063-T5.055"THICK RIGIDPVC.050"THICK RIGID PVC.050"THICK SIGNED: 12/17/2014 M650 IwDOWESTMARKETS D SDOORS \\`` "R I o GRATZ, PA 17030-0370r s, SINGLE SERIES 185 ALUMINUM SINGLE HUNG WINDOW =*• 0 51 *= XNLSI CO COMPOPONEENTS TAT OF DRAWN: DWG NO. REV �O�F '�[pR10P•��'�.� 08 SCALE NTS DATE 12/09/14 SHEET EEr80F 8 /fill% Ilk L. Roberto Lomas P.E. Engineering Evaluation Report 233 W.Main St Danville,VA 24541 Report No.: 513320 434-688-0609 rllomas@lrlomaspe.com Manufacturer: MI Windows &Doors 650 West Market Street Gratz, PA, 17030 Product Line: Series 185 Aluminum Single Hung Window 52"x 72"—LMI Compliance: The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of Business and Professional Regulation for Statewide Acceptance per Rule 61 G20-3.005 method 1(a).The product listed herein complies with requirements of the Florida Building Code. Supporting Technical Documentation: 1. Approval document:drawing number 08-02544, prepared,signed and sealed by Luis Roberto Lomas P.E. 2. Test report No.: E1726.01-109-47 signed and sealed by Michel D.Stremmel P.E. Architectural Testing Inc.,York, PA AAMA/WDMA/CSA 101/I.S.2/A440-08 Design pressure: ±60.15psf Water penetration resistance 9.19psf 3. Test report No.: El 726.02-109-47 signed and sealed by Michel D.Stremmel P.E. Architectural Testing Inc.,York, PA ASTM El886-05 and ASTM El 996-12 ASTM E1886/E1996 Large Missile Impact,Level D,Wind Zone 3 ASTM E1886/E1996 Cyclic Load Test,±55.Opsf design pressure 4. Anchor calculations, report number 513320-1,prepared,signed and sealed by Luis Roberto Lomas P.E. Limitations and Conditions of use: • Maximum design pressure: ±55.Opsf • Maximum unit size: 52"x 72" • Units must be glazed per ASTM E 1300-04,see installation instructions for glass details. • This product is not rated to be used in the HVHZ. • This product is impact resistant and does not require impact protection in wind borne debris regions. • Frame material to be Aluminum 6063-T5. Installation: Units must be installed in accordance with approval document, 08-02544. Certification of Independence: Please note that I don't have nor will acquire a financial interest in any company manufacturing or distributing the product(s)for which this report is being issued.Also, I don't have nor will acquire a financial interest in any other entity involved in the approval process of the listed product(s). `*4- TAT 051 •yt r . ...10 OF w= ��.c�•. ORIDP- 0NAt1����`� 1 of 1 Luis R.Lomas,P.E. FL No.:62514 12/18/2014