HomeMy WebLinkAboutRevisions RECE11"D NOV 131015
OFFICE USE ONLY:
DATE FILED: ` I3 5 PERMIT# SLC 1508-0022
REVISION FEE: - 3 RECEIPT#
PLANNING& DEVELOPMENT SERVICES -
F BUILDING&CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
u ° FORT PIERCE,FL 34982-5652
- (772)462-1553 FAX(772)462-1578
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
1. LOCATION/S
ADDRESS: �H9 Live Oak Ln. Fort Pierce,FL 34981
2. DETAILED DESCRIPTION OF PROJECT
REVISIONS:
Revise permit SLC 1508-0022 removing the 3 windows and adding 1 hurricane fabric panel.
3. CONTRACTOR INFORMATION:
STATE of FL REG./CERT.#: CRC046.858S� LUC�E COUNTY CERT.#: 24548
BUSINESS NAME: The HumAt Home ervices
QUALIFIERS NAMEoysie Ramdial
ADDRESS. o 4 S Military Trail
FE 33442
CITY: Deerfield BeachSTATE: ZIP:
PHONE(DAYTLME): 469 - 5599 xt 12 FAX:
4. OWNERBUILDER INFORMATION:
NAME: Reesa Roberts
ADDRESS: 3209 Live Oak Ln.
CITY: ronSTATE: FL ZIP: 34981
PHONE: FAX:
5. ARCHITECT/ENGINEER INFORMATION:
NAME:
ADDRESS:
CITY: STATE: ZIP:
PHONE(DAYTLVIE): FAX:
Revised 07/22/2014
I N
REVI "
y
Co
Revise permit SLC 1508-0022 removing �
the 3 windows and adding 1 hurricane �
fabric panel. O Uj
w �
U
LU
Garage
1
Not replacing the
windows
Reesa Roberts,##841611018434328
3209 Live Oak Ln_
Fort Pierce,FL 34981
................
11Hurricane Fabric Panel 1125"x 71"'ILiving Room FL 15208.1 I-r :35.8 44.8
Installing 2 hurricane fabric panels. 2 Hurricane Fabric Panel 301"x 94" Lanai IFL.15208.11-i- 32.6,: 38.3
Company: The Home Depot At Home Services Job Description: Installing 2 hurricane fabrie-i
Prepared By: Amber
Client Name: Roberts Project Number: 8416110/8434328
Version 10 0 r /� t
={c 2012 Structures Inte ndLonal LLC, 4W t N�D WAL '�; a. Conforms with ASS E 7 10
tr a. �# u.-S '•iia ,...- "n.V w� ixaws�.'�.
DESIGN PRESSURES FOR WALL COMPONENTS&CLADDING
- G
Design Data Building Data
Wind Velocity(mph) 160 Mean Roof Height 12
Risk Category 2 Building Width(ft) 40
Exposure Category D Building Length(ft) 60
Directionality Factor 0.85 Roof Slope (x:12) 3
Internal Pressure Coefficient+/ 0.18
Design pressures listed below are: Allowable Stress
OPENING OPENING LOCATION OPENING OPENING DIMENSIONS MAXIMUM POSITIVE MAXIMUM NEGATIVE
MARK DESCRIPTION ZONE ELEVATION WIDTH(INCHES) HEIGHT(INCHES) PERSSURE(PSF) PRESSURE(PSF)
1 Hurricane Fabric Panel 5 5 125 71 35.8 -44.8
2 Hurricane Fabric Panel 5 0 301 94 32.6 -38.3
Width of End Zone(a)in feet= 4
5 h
Y I O O a
0
i
5 5
STRUCTURES INTERNATIONAL,LLC
.AS4iYS ll�SdP..y�C.�+G•£, ZY'aC.:r,3c."-�as�CT2'•
11/12/2015 9:53 AM