Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_40.aspx?param=wGEVX. r.. e ECEIt.LD NOV 13 101 Florida Departmentq SCIS Home Log In I User Registration Hot Topics I Submit Surcharge I Stats&Facts Publications FBC Staff j BCIS Site Map links Search f Busines (� 4113roduct Professi nal Approval USER:Public User Regulation Product Approval Menu>Product or ADDOcatlon Search>Application List>F to W FL# FL1956-R12 Application Type Editorial Change Code Version 2014 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer TAMKO Building Products,Inc. Address/Phone/Email PO Box 1404 Joplin,MO 64802 (417)624-6644 Ext 2305 kerri—eden@tamko.com Authorized Signature Kerri Eden kerri_eden@tamko.com Technical Representative Kerri Eden Address/Phone/Email PO Box 1404 Joplin,MO 64802 (417)624-6644 Ext 2305 kerri—eden@tamko.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Certification Mark or Listing Certification Agency UL LLC Validated By Robert J. M. Nieminen, PE Validation Checklist-Hardcopy Received Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2009 ASTM D3462 2009 ASTM D7158 2008 Equivalence of Product Standards Certified By 1 of 4 10/27/2015 8:51 AA Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_ tl.aspx?param=wGEVX.. Product Approval Method Method 1 Option A Date Submitted 09/17/2015 Date Validated 10/06/2015 Date Pending FBC Approval Date Approved 10/09/2015 Summary of Products FL# Model, Description Number or Name 1956.1 Elite Glass-Seal A three tab asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015.pdf HVHZ:No FL1956 R12 C CAC UL certification 10-11-12.pdf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure:N/A FL1956 R12 II Glass Seal Elite Glass Seal app inst.pdf Other:Asphalt shingles Verified By: Robert Nieminen 59166 shall be used only on roof Created by Independent Third Party: No slopes of 2:12 or greater. Evaluation Reports Nails must be used as the Created by Independent Third Party: method of attachment. 1956.2 Glass-Seal A three tab asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956-2015.pd HVHZ: No FL1956 R12 C CAC UL certification 10-11-12.pdf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant: N/A Installation Instructions Design Pressure:N/A FL1956 R12 II Glass Seal Elite Glass Seal apo inst pdf Other:Asphalt shingles Verified By: Robert Nieminen PE 59166 shall be used only on roof Created by Independent Third Party: No slopes of 2:12 or greater. Evaluation Reports Nails must be used as the Created by Independent Third Party: method of attachment. 1956.3 Heritage A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956-2015.pd HVHZ:No FL1956 R12 C CAC UL certification 10-11-12 pdf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure:N/A FL1956 R12 II Heritage D F ] P apo inst.pdf Other:Asphalt shingles FL1956 R12 II Heritage F app inst.pdf shall be used only on roof FL1956 R12 II Heritage T app inst.pdf slopes of 2:12 or greater. Verified By: Robert J.M.Nieminen FL 59166 Nails must be used as the Created by Independent Third Party: No method of attachment. Evaluation Reports Created by Independent Third Party: 1956.4 Heritage 30 A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956_2015.pd HVHZ:No FL1956 R12 C CAC UL certification 10-11-12.pdf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure:N/A FL1956 R12 II heritage 30 app inst april 30.pdf Other:Asphalt shingles FL1956 R12 II heritage 30 app inst f april 10 pdf shall be used only on roof Verified By: Robert Nieminen PE 59166 slopes of 2:12 or greater. Created by Independent Third Party: No Nails must be used as the Evaluation Reports method of attachment. Created by Independent Third Party: 2 of 4 10/27/2015 8:51 AM Florida Building Code Online https://www.floridabading.org/pr/pr_appjtl.aspx?param=wGEVX... 1956.5 Heritage 50 A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015.pdf HVHZ:No FL1956 R12 C CAC UL certification 10-11-12.pdf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure:N/A FL1956 R12 II heritage-50-app Inst april 10.pdf Other:Asphalt shingles FL1956 R12 II heritage 50 app inst f april 10.pdf shall be used only on roof Verified By: Robert Nieminen PE 59166 slopes of 2:12 or greater. Created by Independent Third Party: No Nails must be used as the Evaluation Reports method of attachment. Created by Independent Third Party: 1956.6 Heritage A dimensional asphalt shingle. Premium Limits of Use Certification Agency Certificate Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956_2015.pdf HVHZ: No FL1956 R12 C CAC UL certification 10-11-12.pdf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant: N/A Installation Instructions Design Pressure:N/A FL1956 R12 II Heritage Premium D P app inst.pdf Other:Asphalt shingles FL1956 R12 II Heritage Premium F app inst.ndf shall be used only on roof FL1956 R12 II Heritage Premium T app inst.pdf slopes of 2:12 or greater. Verified By: Robert Nieminen 59166 Nails must be used as the Created by Independent Third Party: No method of attachment. Evaluation Reports Created by Independent Third Party: 1956.7 Heritage A heavy weight dimensional asphalt shingle. Vintage Limits of Use Certification Agency Certificate Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015.pd HVHZ: No FL1956 R32 C CAC UL shingle matrix.pdf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure:N/A FL1956 R12 II Heritage Vintage app inst.pdf Other:Asphalt shingles Verified By: Robert]. M. Nieminen PE 59166 shall be used only on roof Created by Independent Third Party: No slopes of 2:12 or greater. Evaluation Reports Nails must be used as the Created by Independent Third Party: method of attachment. 1956.8 Heritage Hip and ridge shingles Vintage 12 X 12 Hip and Ridge Limits of Use Certification Agency Certificate Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015 pdf HVHZ: No FL1956 R12 C CAC UL shingle matrix. df Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure:N/A FL1956 R12 II TAMK0@ HeritageQ 12 x 12 Hip and Ridge Application Instructions.pd Other:Asphalt shingles Verified By: Robert 1.M.Nieminen PE 59166 shall be used only on roof Created by Independent Third Party: No slopes of 2:12 or greater. Evaluation Reports Nails must be used as the Created by Independent Third Party: method of attachment. 1956.9 Heritage A dimensional asphalt shingle. Woodgate Limits of Use Certification Agency Certificate Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015.pdf HVHZ:No FL1956 R12 C CAC UL certification 10-11-12 )df Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure: N/A FL1956 R12 II Heritage Woodgate D app inst.pdf Other:Asphalt shingles FL1956 R12 II Heritage Woodgate F app inst.odf shall be used only on roof Verified By: Robert Nieminen 59166 slopes of 2:12 or greater. Created by Independent Third Party: No 3 of 4 10/27/2015 8:51 AM Florida Building Code Online https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVX.. Nails must be used as the Evaluation Reports method of attachment. Created by Independent Third Party: 1956.10 1 Heritage XL A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use In FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956_2015.pdf HVHZ:No FL1956 R12 C CAC UL certification-10-11-12.0 Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant.N/A Installation Instructions Design Pressure:N/A FL1956 R12 II heritage A app inst d april 10.pdf Other:Asphalt shingles FL1956 R12 II heritage A app inst IF aDril 10.pdf shall be used only on roof Verified By: Robert Nieminen PE 59166 slopes of 2:12 or greater. Created by Independent Third Party: No Nails must be used as the Evaluation Reports method of attachment. Created by Independent Third Party: 1956.11 Hip and Ridge Hip and ridge shingles Shingles Limits of Use Certification Agency Certificate Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015.Ddf HVHZ: No FL1956 R12 C CAC UL certification 10-11-12.pdf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 09/17/2018 Impact Resistant:N/A Installation Instructions Design Pressure:N/A FL1956 R12 II 12.25x12 Hip and Ridge.pdf Other:Hip and Ridge FL1956 R12 II 12 x 12 Hip Ridge Application Instructions,pd shingles shall be used only FL1956 R12 II 12-1-4x12 HipRidge Sealant Dab Illustrations pdf on roof slopes of 2:12 or FL1956 R12 II 12x12 HipRidge Sealant Dab Illustrations pdf greater. Nails must be used Verified By: Robert Nieminen 59166 as the method of Created by Independent Third Party: No attachment. Evaluation Reports Created by Independent Third Party: eadc Next Contact Us::1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AAJEEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your a-mafl address released In response to a public-records request,do riot send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.if you have any questions,please contact 850.487.1395.*Pursuant to section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: EChtcY. 0 sccuritv.Nn,-rmc; 4 of 4 10/27/2015 8:51 AM ® Application Instructions for FORMERLY HERITAGE®30 TAMKO HEIRtTANG D9I601NO PRODUCTS 6AMINATED ASPHA6T SHINO6ES Dallas, TX • Frederick, MD - Joplin, MO 9 Phillipsburg, KS THESE ARE THE MANUFACTURER'S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED. TAMKO BUILDING PRODUCTS,INC.ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING DEFECTS RESULTING FROM FAILURE TO FOLLOW THE MANUFACTURER'S INSTRUCTIONS.FAILURE TO FOLLOW THESE INSTRUCTIONS WILL ADVERSELY AFFECT COVERAGE UNDER THE LIMITED WARRANTY.SEE THE LIMITED WARRANTY FOR DETAILS. THIS PRODUCT IS COVERED BY A LIMITED WARRANTY,THE TERMS OF WHICH ARE PRINTED ON THE WRAPPER. IN COLD WEATHER(BELOW 40°F),CARE MUST BE TAKEN TO AVOID DAMAGE TO THE EDGES AND CORNERS OF THE SHINGLES. IMPORTANT:It is not necessary to remove the plastic strip from the back of the shingles. 1.ROOF DECK &FASTENERS These shingles are for application to roof decks consisting of plywood WIND CAUTION: Extreme wind velocities can damage these or sheathing boards capable of receiving and retaining fasteners,and shingles after application when proper sealing of the shingles does to inclines of not less than 2 in.per foot.For roofs having pitches 2 in. not occur.This can especially be a problem if the shingles are applied per foot to less than 4 in.per foot,refer to special instructions titled in cooler months or in areas on the roof that do not receive direct "Low Slope Application".For roofs having pitches greater than 21 in. sunlight.These conditions may impede the sealing of the adhesive per foot,refer to special instructions titled"Mansard Roof or Steep strips on the shingles.The inability to seal down may be compounded Slope Roof'.Shingles must be applied properly.TAMKO assumes no by prolonged cold weather conditions and/or blowing dust.In these responsibility for leaks or defects resulting from improper application, situations,hand sealing of the shingles is required.To insure quicker or failure to properly prepare the surface to be roofed over. sealing, apply 4 quarter-sized dabs of TAM-PRO® SBS Flashing Cement,TAMKO or TAM-PRO®Plastic Roof Cement,or TAM KO NEW ROOF DECK CONSTRUCTION:Roof deck must be smooth, Tam-Seal Adhesive,meeting ASTM D 4586,Type 1,on the back of dry and free from warped surfaces. It Is recommended that metal the shingle 1 in.(25mm)and 13 in.(330mm)in from each side and drip edges be installed at eaves and rakes. 1 in.(25mm)up from the bottom of the shingle.Press shingle firmly into the adhesive.For maximum wind resistance along rakes,install PLYWOOD: All plywood shall be exterior grade as defined by any TAMKO starter shingle including sealant or cement shingles to APA - The Engineered Wood Association. Plywood shall be a the underlayment and each other in a 4 in.(102mm)width of TAM- minimum of 3/8 in.thickness and applied in accordance with the PRO® SBS Flashing Cement,TAMKO or TAM-PRO® Plastic Roof recommendations of APA-The Engineered Wood Association. Cement,or TAMKO Tam-Seal Adhesive.Caution:Apply ONLY a thin SHEATHING BOARDS: Boards shall be well-seasoned tongue- uniform layer of adhesive less than 1/8 in.(3mm)thick.Excessive and-groove boards and not over 6 in.nominal width.Boards shall amounts can cause blistering of the shingles and may soften the be a 1 in. nominal minimum thickness. Boards shall be properly asphalt in certain underlayments resulting in the asphalt flowing, spaced and nailed. dripping and staining.Shingles must also be fastened according to the fastening instructions described below. Z.VENTMATION Correct placement of the fasteners is critical to the performance of the shingle.If the fasteners are not placed as shown in the diagram Inadequate ventilation of attic spaces can cause accumulation of and described below,this will result in the termination of TAMKO's moisture in winter months and a build up of heat in the summer. liabilities underthe Limited Warranty.TAMKO will not be responsible These conditions can lead to: for damage to shingles caused by winds in excess of the applicable 1.Vapor Condensation mph as stated in the Limited Warranty.See Limited Warranty on the 2.Buckling of shingles due to deck movement. wrapper or tamko.com for details. 3.Rotting of wood members. FASTENING PATTERNS:Fasteners must be placed 6-1/8 in.from 4.Premature failure of roof. the bottom edge of the shingle, penetrating through the common bond,and located horizontally as follows: To insure adequate ventilation and circulation of air,the ventilation 1)Standard Fastening Pattern.(For use on decks with slopes 2 system must include inlets and outlets.This may be accomplished with in.per foot to 21 in.per foot.)One fastener 1 in.from each end and a combination of ridge and soffit vents or by using gable end vents. one 13-1/2 in.from each end of the shingle for a total of 4 fasteners. FHA minimum property standards require one square foot of net free (See Standard Fastening Pattern illustrated below). ventilation area to each 150 square feet of space to be vented.This may be reduced to one square foot of ventilation area per 300 square STANDARD FASTENING PATTERN feet if at least 40% and not more than 50% of venting is provided FASTENERS NAILZONE not more than 3 feet below the ridge or if a Class I or II vapor barrierCOMMON is installed on the warm in winter side of the ceiling in climate zones BOND 6,7,and 8 as recommended by the 2012 International Residential 6_1/8" FSURES-518" Code.For more information consult your design professional.If the ventilation openings are screened,the total area should be doubled. 1 12_1/2" -12-3/8° — 12-1/2'x++ h 1" IT IS PARTICULARLY IMPORTANT TO PROVIDE ADEQUATE VENTILATION. (Continued) Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 09/19/14 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055 Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656 tamko.COm Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 1 0 (CONTINUED from page 1) FORMERLY HERITAGE®30 ITA IM K 0HERITAGEO BUILDING PRODUCTS LAMINATED ASPHALT SHINGLES Dallas,TX • Frederick, MD • Joplin, MO • Phillipsburg, KS 2) Mansard Fastening Pattern. (For use on decks with slopes be a minimum of 1-1/4 in. for new construction and 1-1/2 in.for greater than 21 in.per foot.)One fastener 1 in.from each end and reroofing thus allowing a minimum deck penetration of 3/4 in.The one fastener 8-1/2 in.from each end and one fastener 16 in.from properly Driven Improperly Driven each end for a total of 6 fasteners per shingle. (See Mansard and underdthen overdriven crooked High Wind Fastening Pattern illustrated below.) AsPhan MANSARD AND HIGH WIND WARRANTY FASTENING PATTERN shingles NAIL ZONE ME \��'--Decking FASTENERS COMMON ` WE BOND k �n EXPOSURES-5/8" crown of the staple must be parallel to the length of the shingle. The staple crown should be driven flush with the shingle surface. �=sl h 7-1n"►f��-12"fir z-aye"+�a -�n"�{a 7•�2"r� [*-r' Staples that are crooked,underdriven or overdriven are considered 3)High Wind Warranty Fastening Pattern.(For High Wind Warranty improperly applied. Application requirements) One fastener 1 in.from each end. One CAUTION: ALL FASTENERS MUST BE DRIVEN INTO THE fastener 8-1/2 in.from each end and one fastener 16 in.from each NAIL ZONE COMMON BOND AS SHOWN IN THE FASTENING end for a total of six(6)fasteners per shingle. In addition to this PATTERN DIAGRAMS. shingle fastening pattern requirement for High Wind Application, TAMKO also requires the use of TAMKO starter shingles including 4.UNDERLAYMENT sealant strip at eaves and rakes.Alternatively,along rakes,cement UNDERLAYMENT. An underlayment must be applied over the shingles to the underlayment and each other in a 4 in. (102 mm) entire deck before the installation of TAMKO shingles.Failure to add width of TAM-PRO® SBS Flashing Cement,TAMKO or TAM-PRO® underlayment can cause premature failure of the shingles which is Plastic Roof Cement,orTAMKO Tam-Seal Adhesive.Caution:Apply not covered by TAMKO's Limited Warranty. ONLY a thin uniform layer of adhesive less than 118 in.(3mm)thick. Excessive amounts can cause blistering of the shingles and may Products which are acceptable for use as underlayment are: soften the asphalt in certain underlayments resulting in the asphalt Asphalt Saturated Felt Underlayments: flowing,dripping and staining. • SuperX 30TM Underlayment High Wind Application is offered on new construction or complete • TAMKO No.15 Asphalt Saturated Organic Felt tear-off applications only.It is not offered for recover applications. • Any TAMKO non-perforated asphalt saturated organic felt If High Wind Application requirements are not followed, the High • A non-perforated asphalt saturated organic felt which meets Wind Application Warranty MPH,as stated on Table I in the Limited ASTM:D226,Type I or II or ASTM D4869 Warranty,reverts to the Standard Application Wind Warranty MPH Specialty Underlayments: limit. (See Mansard and High Wind Fastening Pattern illustrated above.) • Tam-Shield® Synthetic Underlayment or Synthetic Shield Underlayment NAILS:TAMKO recommends the use of nails asthe preferred method . TAMKO TW Metal and Tile Underlayment,TW Underlayment of application. Standard type roofing nails should be used. Nail and Moisture Guard Plus® (additional ventilation may be shanks should be made of minimum 12 gauge wire,and a minimum required. Contact TAMKO's Technical Services Department head diameter of 3/8 in.Nails should be long enough to penetrate for more information.) 3/4 in.into the roof deck.Where the deck is less than 3/4 in.thick, . A self-adhesive underlayment designed for use with asphalt the nails should be long enough to penetrate completely through shingles which meets ASTM D1970. plywood decking and extend at least 1/8 in.through the roof deck. Drive nail head flush with the shingle surface. For Asphalt Saturated Felt Underlayments: Apply the felt when the deck is dry.On roof decks with slopes Map1 T,'A' Impr—dIl Drivon 4 in.per foot and greater apply the felt parallel to the eaves (�=are°min dtameler unaerd tura everarlven ctoehed lapping each course of the felt over the lower course at least Asphalt 2 in.Where ends join,lap the felt 4 in.If left exposed,the felt Shingles r may be adversely affected by moisture and weathering.Laying a� ± ~eac11ng of the felt and the shingle application must be done together. _ �1/4°nominal straight,good penetrallan, Inadequate toodmp,cuta Inadequate For All Other Specialty Underlayments: and flush with shingleeurface penetration Into shingle anchorage On roof decks with slopes 4 in. per foot and greater apply the underlayment parallel to the eaves in accordance STAPLES:If staples are used in the attaching process,follow the with underlayment written application instructions. The above instructions for placement.All staples must be driven with underlayment should not be left exposed for a longer period of pneumatic staplers.The staple must meet the following minimum time than is specified in the underlayments written application dimensional requirements.Staples must be made from a minimum instructions.The final roof covering must be installed before 16 gauge galvanized wire.Crown width must be at least 15/16 in. the structure is exposed to adverse weather conditions,such (staple crown width is measured outside the legs).Leg length should as wind driven rain,high wind,hail,ice storms,etc. (Continued) Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 09/19/14 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055 Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656 talmko.com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 2 ® (CONTINUED from page 2) FORMERLY HERITAGES 30 LZAINK0 HEHITANG BUI60ING PRODUCTS LAMINATED ASPHALT SHINGLES Dallas, TX • Frederick, MD • Joplin, MO • Phillipsburg, KS In areas where ice builds up along the eaves or a back-up of water of shingle to start the fourth course and use the remaining 10-3/8 from frozen or clogged gutters is a potential problem, TAMKO's in.piece to begin the fifth course-Continue up the rake in as many Moisture Guard Plus®, TW Metal and Tile Underlayment or TW rows as necessary using the same formula as outlined above. Underlayment (or any specialty eaves flashing product) may be The butt of the shingle should be aligned with the top edge of the applied to eaves,rakes,ridges,valleys,around chimneys,skylights sawtooth of the underlying shingle for a 5-5/8 in. exposure (see or dormers to help prevent water damage. Contact TAMKO's Technical Services Department for more information. shingle application drawing illustrated on this panel). When you make your final cut at the roof's edge,flip any pieces that are 8 in.or Substitute products as shingle underlayment should not be used. longer back onto the roof.These pieces can be worked in anywhere without creating zippers or color variations. S.APPLICATION INSTRUCTIONS without Do not align joints of shingle courses when working in cut STARTER COURSE:A starter course may consist of TAMKO Shingle pieces.Joints should be no closer than 4 in.from one another. Starter,TAMKO 10-inch Starter or self-sealing 3-tab shingles.If self- sealing 3-tab shingles are used,remove the exposed tab portion and install with the factory applied adhesive adjacent to the eaves.Attach t Cut your lest course shingle to make 29'and a 10316" length.Cut a second shingle to make a 23"and the starter course with approved fasteners along a line parallel to a,630 to lid. ; and 1.5 in.to 3 in.above the eaves edge.The starter course should 11°3 6" overhang both the eaves and rake edges 1/4 in.to 3/8 in.if drip edge flashing is not used along the eaves or rakes.If drip edge flashing is present,install shingles even with the drip edge. Mldz For KO starter wind shingle Inanee along ekes,cement any TAMKOsGdentend adiot ier Insealant4"If cmemshhof i m wdeday SB and shin Darer Ina TAMKO omm)rT width of - - PIas5.TAM-PR09SBSFlashagCement,m-SelTam -. Underlayment Deck Pla9ieRoofcemen4orTAMKOTam-Sem Adhesive. evestur or _ asphaltIt saturated felt -- Drip—� edge Degin appguatltm vdth a lull length shingle. ---------------------------------------------------- -- 2.Then lay your 29•,23',163/6'and i a 3W lengths Rake!- \- you can see,three shingles with M4 alta make live lauraea. Fasteners looted 1-10 to F from rake edge --- - - - - 1, qq Contawe working your way across the root.When you make your __ —�---�—— �D.final col at the roars edge,flip any pleces that are 0'or longer 1r ) bark\ a,; the real.These pieces can be—ked in anywhere without\ seating zippers or cdor vadatlons. NOTE:Do not align binds of shingle courses when—Icing in Sart fid strip with 1/2 shingle Stader ships overhang Sell-sealing Eave Fasteners Drip edge cut pleces Joints should be me closer than 4•horn ono emother. oved.then follow with full eaves and rakes adhesive located sup n and. to offset with the 114'to 316'it no drip edge positioned 7-12'to 3' urs sNngle course. flashing is present.11 drip along ewes from eave edge nil" a�esi'e°en.ith a rake edge 6.LOW SLOPE APPLICATION ddp edge. SHINGLE APPLICATION:Start the first course with a full size shingle On pitches 2 in.per foot to 4 in.per foot cover the deck with two and overhang the rake edge 1/4 in.if drip edge is not present.If layers of underlayment. Begin by applying the underlayment in a drip edge is present,align shingle edge with drip edge flashing.Cut 1/2-sheet width along the eaves and overhanging the drip edge 10-3/8 in.from a full shingle to form a shingle 29 in.long.Use this by 1/4 to 3/4 in. Place a full-sheet width over the 1/2-sheet width to start the second course(see diagram below). Cut a 23 in. long starter piece,completely overlapping it.All succeeding courses will shingle to start the third course.Use the remaining 16-3/8 in.piece be positioned to overlap the preceding course by 1/2-sheet width. If winter temperatures average 25°F or less, thoroughly cement 10-3/6" the laps of the entire underlayment to each other with TAM-PRO or TAMKO Plastic Roof Cement from eaves and rakes to a point of a least 24 in. inside the interior wall line of the building.As an courses 16-assn 1a3ts 29° alternative,TAMKO's Moisture Guard PlusO,TW Metal and Tile 23 Underlayment, or TW Underlayment self-adhering underlayment zs^ may be used in lieu of the cemented felts. rake FUII 16.3/6^1 23" 7.MANSARD ROOF OR STEEP SLOPE ROOF 1°ass" If the slope exceeds 21 in.per foot(60),each shingle must be sealed SNl course - with TAM-PRO® SBS Flashing Cement, TAMKO or TAM-PRO® 16-31e, Plastic Roof Cement, or TAMKO Tam-Seal Adhesive immediately au course upon installation.Quarter-sized dabs of cement or adhesive must We— 23 be applied to shingles with a 5-5/8 in.exposure,use 6 fasteners per 2nd course _ 29" 29" shingle.See Section 3 for the Mansard Fastening Pattern. 1 st course Full 10-316" ve. (Continued) Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 09/19/14 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055 Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656 tamko.com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 3 — --- _ — a (CONTINUED from page 3) FORMERLY HERITAGE°30 UTAMK:01 HERITAGE® BUILDING PRODUCTS LAMINATED ASPHALT SHINGLES Dallas, TX • Frederick, MD • Joplin, MO ® Phillipsburg, KS O.RE-ROOFING 8.VALLEY APPLICATION Before re-roofing,be certain to inspect the roof decks.All plywood shall Over the shingle underlayment,center a minimum 36 in.wide sheet of meet the requirements listed in Section 1. Moisture Guard Plus'',TW Metal&Tile Underlayment,or a minimum It is not recommended to install laminated asphalt shingles directly 50 Ib. roll roofing in the valley. Nail the underlayment only where over existing laminated shingles due to the unevenness of the existing necessary to hold it in place and then only nail the outside edges. multi-layered shingles.The performance of the sealant feature may be IMPORTANT PRIOR TO INSTALLATION WARM SHINGLES TO compromised,preventing the shingles from sealing properly.It is PREVENT DAMAGE WHICH CAN OCCUR WHILE BENDING acceptable to install laminated shingles over existing three-tab strip SHINGLES TO FORM VALLEY. shingles which areflat and essentially intact.Nail down or remove curled or broken shingles from the existing roof.Replace all missing shingles After valley flashing is in place: with new ones to provide a smooth base.Shingles that are buckled • Apply the first course of shingles along the eaves of one of the usually indicate warped decking or protruding nails.Hammer down all intersecting roof planes and across the valley. protruding nails or remove them and refasten in a new location.Remove all drip edge metal and replace with new. Note:For proper flow of water over the trimmed shingle,always If re-roofing over an existing roof where new flashing is required to start applying the shingles on the roof plane that has the lower protect against ice dams(freaze/thaw cycle of water and/or the backup slope or less height. of water in frozen or clogged gutters),remove the old roofing to a point Extend the end shingle at least 12 in.onto the adjoining roof. at least 24 in,beyond the interior wall line and appiyTAMKO's Moisture Apply succeeding courses in the same manner,extending them Guard Plus®,TW Metal and Tile Underlayment,or TW Undedayment. across the valley and onto the adjoining roof. Contact TAM KO's Technical Services Department for more information. Measurements will vary when nesting over an existing 5 in.exposure Press the shingles tightly into the valley. single roof:Call TAMKO Technical Services for further information. Use normal shingle fastening methods. The nesting procedure described below is the preferred method for Note:No fastener should be within 6 in.of the valley centerline, reroofing over existing metric size shingles with a 5-5/8 in.exposure. and two fasteners should be placed at the end of each shingle See description below: crossing the valley. Starter Course.Remove the tabs and an additional portion from the To the adjoining roof plane,apply one row of shingles vertically head of a full size shingle so that its height is equal to the exposure of facing the valley and 2 in.back from the valley centerline. the existing shingles.Position the resulting strip over the existing roof edge(with the factory-applied adhesive strip along the eaves).Cut Note: For a neater installation, snap a chalkline over the approximately 6 in.from the rake end and apply the remaining portion at shingles for guidance. theeaves.Continue the starter strip by applyingfull length shinglestrips To complete the valley, apply shingles on the adjoining roof cut to height as above,evenly along the existing roof at the eaves.The plane by positioning the tip of the first shingle of each row at existing roof should overhang the eaves far enough to carry water the 2 in.point from the centerline where the edge of the vertical off into the gutter.If this is not the case,cut and apply the starter shingle has been applied,covering the vertical shingle. strip so that it will provide sufficient overhang for proper drainage. ExlsUng shingles Minimum 36'wide sheet Valley centerline of Moisture Guard Plus, I 5�, TwMetal& Extra nail in Tile or 50 lb.or end of shingle \ 14' heavier roll roofing I Extend end shingle 12"-18"beyond orry edge � valley centerline Op edge Naw Mi.gol 3 Underlayment No fasteners within 6'of centerline 55/8" 3518'o pastre eyosure First Course:Remove an amount from the butt edge of afull-size shingle so that the remaining portion of the shingle fits between the butts of the existing third course.This course must also be applied evenly along the eaves edge of the new starter strip. Place tip of shingle on the edge of the vertical shingle,2 inches back Second and Succeeding Courses;Remove 10-3/8 in.from the rake from valley centerline and covering end of the first shingle in the second course, and continue with full the vertical shingle. width shingles for the remainder of the course,placing the top edge of each new shingle against the butt edge of the old shingle in the course FOR ALTERNATE VALLEY APPLICATION METHODS, PLEASE above.This method should create an exposure of 5-5/8 in.after the first CONTACT TAMKO'S TECHNICAL SERVICES DEPARTMENT AT course.When beginning the succeeding courses continue to follow the 800-641-4691. Heritage application instructions.(See section 5). (Continued) Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 09/19/14 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055 Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656 taIllkoxor l Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 4 MTAMg ® (CONTINUED from page 4) FORMERLY HERITAGE13 30 O:] HERITAGE" BUILDING PRODUCTS 6AMINATED ASPHALT SHING6CS Dallas,TX • Frederick, MD • Joplin, MO • Phillipsburg, KS 10.®IP AND RIDGE FASTENING DETAIL Apply the shingles with a 5-1/8 in.exposure beginning at the bottom of the hip or from the end of the ridge opposite the direction of the prevailing winds.Secure each shinglewith one fastener on each side, 5-5/8 in.back from the exposed end and 1 in.up from the edge. TAMKO recommends the use of TAMKO Hip & Ridge shingle products.Where matching colors are available, it is acceptable to use TAMKO's Elite Glass-Seal shingles cut down to 12 in.pieces. Fasteners should be 1/4 in.longer than the one used for shingles IMPORTANT: PRIOR TO INSTALLATION, CARE NEEDS TO BE TAKEN TO PREVENT DAMAGE WHICH CAN OCCUR WHILE BENDING SHINGLE IN COLD WEATHER. Direction of prevailing wind Start �5-1/8"exposure here— 5�1 Fastener Start 5-1/8"exposure THESE ARE THE MANUFACTURER'S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED.TAMKO BUILDING PRODUCTS, INC.ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING DEFECTS RESULTING FROM FAILURE TO FOLLOW THE MANUFACTURER'S INSTRUCTIONS. FAILURE TO FOLLOW THESE INSTRUCTIONS WILL ADVERSELY AFFECT COVERAGE UNDER THE LIMITED WARRANTY. SEE THE LIMITED WARRANTY FOR DETAILS. IF YOU HAVE ANY QUESTIONS REGARDING THESE APPLICATION INSTRUCTIONS, PLEASE CONTACT TAMKO'S TECHNICAL SERVICES DEPARTMENT AT 800-641-4691. Information included in these application instructions was current at time of printing.To obtain a copy of the most current version of these application instructions,visit us online at tamko.com or call us at 8D0-641-4691. TAMKO®,Moisture Guard Plus®,Tam-Shield®,TAM-PROD and Heritage are registered trademarks and SuperX 30 is a trademark of TAMKO Building Products,Inc. Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 09/19/14 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055 Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656 tali ko.0011'1 Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 5 m— . JP69909