HomeMy WebLinkAboutProduct Approval FILE CO . Equivalency of Standards E�LsaWatruion to 2010 FBC Date: November 21, 2011 PTC Report#: 1939 Revision No.: 0 PTC Project#: 411-1003 Product Mfg.: Natural Light Energy Systems 10821 N.23rd Ave. Phoenix,AZ 85029 Product Name: Roof Mounted Solar Attic Fan Product Category: Roofing ~-,P-roduct-Sub-Gategory-.—-Roofing Acc-essories-that-are�e'n4ntegral,-Partof the-Roofing-System Compliance Method: Product Approval Rule 9N-3.015(4)(d)–Equivalency of Standards.Evaluation Report by a Licensed Professional Engineer Prepared For: Natural Light Energy Systems rd 10821 N. 2-3 Ave. % JAIVES Phoenix,AZ 85029 Prepared By: Robert J.Amoruso, P.E. VK: Florida P.E. No.49752 C-kQ PTC Product Design Group, LLC PO Box 520775 Longwood, FL 32752-0775 Florida C of A No.25935 Robert 1.Arnoruso,P.E Florida P.E. License No.49752 FIX Product Design Group,LLC Project No.411-1003 Page 1 PO Box 520775 Report No.1939,Rev.0 Longwood,FL 32752-0775 2010 FBC Equivalency Phone:321-690-1788 Fax:321-690-1789 FBPE Certification of Authorization No.25935 - Scope Evaluate equivalency of testing standards used for the performance testing of Natural Light Energy Systems Roof Mounted Solar Attic Fan for conformance to the 2010 Florida Building Code — Building and Residential Volumes including the High Velocity Hurricane Zone(HVHZ). Description of Product See PTC Product Evaluation Report No. 1938 (Reference 3.a) for a full description of the product including testing standards used and results of testing. Performance and Testing Standards Reference 2 conducted testing to the following standard(s) 1) TAS-100(A)-95,Test Procedure for Wind and Wind Driven Rain Resistance and/or Increased Windspeed Resistance of Soffit Ventilation Strip and Continuous or Intermittent Ventilation System Installed At the Ridge Area 2) TAS-202-94,Criteria for Testing Impact&Nonimpact Resistant-Building Envelope Components Using Uniform Static Air Pressure References and Suppoirting Documents 1) Drawings a. Drawing No. NLS0004,Rev-1,Dated 11/21/11,signed and sealed by Robert J.Amoruso,P.E. 2) Testing a. PRI Construction Materials Technologies Test Report No.NLES-001-02-02,dated 12/30/09, Performance Test Report;Natural Light Systems—40 Watt Solar Attic Fan for Asphalt Shingle Roofs—TAS 100(A)-9S. b. Architectural Testing Inc.Test Report No.A8071.02-301-18,dated 8/24/11, TAS 202 Test Report, Self-Flashing Roof Mounted Attic Ventilation Fan,Series/Model:Solar Attic Fan with 40 Watt Solar Panel for Natural Light Energy Systems. 3) Reports a. PTC Product Design Group,LLC Report No.1938,Dated 11/21/11,Product Evaluation for Roof Mounted Solar Attic Fan for Natural Light Energy Systems. 4) Florida Building Code—Test Protocols a. 2010 i. TAS 202-94 ii. TAS 100(A)-95 PTC Product Design Group,LLC Project No.411-1003 Page P.0 Box 520775 Report No.1939,Rev.0 LonTuvood,FL32752-0775 2010 FBC Equivalency Phone:321-690-1788 Fax:321-690-1789 FSPE Certification of Authorization No. 25935 b. 2007 with 2009 Supplements - L TAS 202-94 ii. TAS 100(A)-95 Equivalency Evaluation Reference 2.a tested for wind and wind-driven rain resistance in accordance with TAS-100(A)-95,Test Procedurefor Wind and Wind Driven Rain Resistance and/or Increased Windspeed Resistance of Soffit Ventilation Strip and Continuous or intermittent Ventilation System Installed at the Ridge Area. o Testing to the above procedure documented in Reference 2.a is based on conformance to the 2007 FBC—Test Protocols with 2009 Supplements. o The 2010 FBC—Test Protocols,TAS 100(A)-95 revised Section 10.4.8 to remove reference to TAS 100(8)which does not exist and requires the user to contact the authority having jurisdiction when testing product for increased windspeed resistance that exceed a height of 12 inches or any other dimension of 18 inches. The product covered by Evaluation Report No.1938 (Ref.3.a)exceeded those limitations.Miami- Dade Product Control was contacted and advised that Checklist No.0463 shall be used.In conformance with this checklist,a uniform static air pressure test in accordance with TAS 202-94 was conducted. wool"NEWWRIONW. Because the requirements of the revised TAS 100(A)-95 were followed and because the changes to TAS 100(A)-95 do not affect testing method or results,conformance to the 2010 FBC is maintained. v CONCLUSION:Testing and documented results in Reference 2.a are compliant with the 2010 FBC— Building Volume, Residential Volume and Test Protocols. Reference 2.b tested uniform static air pressure in accordance with TAS-202-94, Criteria for,Testing Impact& ftnimpact Resistant Building Envelope Components Using Uniform Static Air Pressure v Testing to the above procedure documented in Reference 2.b is based on conformance to the 2007 FBC—Test Protocols with 2009 Supplements. > The 2010 FBC—Test Protocols,TAS 202-SA revised Sections 1.1 and 5.2.2.2 related to calculation, of design pressure using ASCE7-10.Section 5.2.7 was revised to remove revision level from ASTM E283 and Section 13.2.1 revised interval labeling on storm panels. These changes do not affect the testing method or results obtained. o CONCLUSION:Testing and documented results in Reference 2.b are compliant with the 2010 FBC— Building Volume,Residential Volume and Test Protocols. :rC Product Design Group, LLC Project No.411-1003 Page 3 oa Box 520775 Report No.1939,Rev.0 L on .,7ood,FL 32752-0775 2010 FBC Equivalency Phone:321-690-1798 Fax:321-690-1789 FBPE Certification of Authorization No.25935 IMPORTANT: Before Onstaffing Please take the time to read through the ENTIRE instructions prior to starting any work. 1. Ensure normal safety precautions are taken when using tools and walking on roofs. 2. Do not cut any structural members in the house. 3. Measure twice and cut once. Took Requh-ed * Reciprocating Saw o Caulking Gun o Measuring Tape * Marking Pen a Screw Gun a Razor Knife * String o Ladders Components Note: Exploded view for illustrative purposes. Unit comes pre-assembled. 1. (2)#8 Phillips Head Screws/Clip Assembly 3 4 2. Custom Solar Panel 3. Wire Lead 4. Adjustable Solar Panel Bracket S. Aluminum Shroud 6 6. Custom DC Motor \/Y 7. Motor Isolation Bracket 7 S. Air Drive Precision Pitch Blade 9. 4"x 48" Stainless Steel Wire Mesh 10. Rugged 14 Gauge Shroud Support Bracket 11. (6)#6 x 1 1/2" Stainless Steel Phillips 10 Head Screws 12. Aluminum Flashing 11 12— gnstallgation Pointers When determining location of the unit, try to place the solar attic fan on the south side of the roof, also consider potential problems such as objects shading the unit during certain times of the day.The unit should also be centered on the roof and the center of the unit should be about 2 feet down from the roof ridge. Step T Choose location for solar vent unit,south exposure is best. If a Southern ex- posure is not feasible for your installation, the fan can be installed on any 7, other exposure and the solar panel adjusted to capture maximum sunlight. Step 2 Hammer a nail at the center of the location chosen between rafters for the solar attic fan unit. The center of the unit should be about 2 feet down from the ridge.Attach a string to the nail. Measure 9.5"of string and attach a marking pen to the string,see diagram. Scribe a 19"circle onto the roof shingles or use the template created earlier- Step 3 With a reciprocating saw, cut the diameter of the hole. IMPORTANT- The solar attic fan must be installed between the roof rafters or over a roof rafter. DO NOT CUT THROUGH ANY FRAMING MEMBER. Step 4 16"ON CENTER INSTALL Roof rafters are generally 16" or 24" on center. On 16" on center construction, the installer can either cut a 14" hole between the rafters or cut a 19" hole with the roof rafter running through the cut hole - do not cut the rafter(see diagram). On 24"on center construction, center the fan between the rafters. NEVER CUT THROUGH ANY ROOF RAFTERS. LEAVE ALL FRAMING MEMBERS IN PLACE. Only remove roof sheathing. Step 5 With a razor knife, cut a four inch slit through the shingles and tar paper at the three and nine o'clock position of the flashing. This allows for the foot print of the flashing to be inserted under the shingles. NOTE: If a 14" hole was cut instead of a 19" hole in Step 3, additional shingles may also need to be removed on the high Side towards the ridge to allow the flashing to slide over the hole (see inset Illustration). Step 6 Insert the reciprocating saw blade sideways at the three o'clock position and commence cutting the roofing nails up and around to the nine o'clock position. This process removes the nails that will prevent the a flashing foot print from sliding up underneath the shingles. x a l Shap 7 Caulk underside of flashingwith the provided caulking material. Two p 9 concentric rings9 of caulking material is sufficient. g •�� o ,�.'�, NOTE: Installation on tile roofs will require the use of a skirt. ;i;1 o Oo ° Step PO Taking care not to smear caulk on the exposed shingles, slide flashing under tar paper and shingles and force flashing up until the shingles come in contact with the raised portion of the flashing.The bottom side of the o flashing will be on top of the shingles. Secure flashing with four Phillips ,., ; head screws at the 3:00, 6:00, 9:00 and 12:00 positions. The 3:00 and OROMH 9:00 positions screws should go under the shingles. The 6:00 and 12:00IMEMI EE position screws should go on top of the shingles. WOMMMIM Step 9 At the 6:00 and 12:00 positions, caulk over the screw head,since it will be i exposed to the weather. Use remaining caulk to seal the areas where the 4" slits were made and around the area where the shingles meet with the raised area of the flashing. Step 10 Loosen, but do not remove, the screw on the clip/screw assembly located on each side of the solar panel bracket. Adjust the solar panel to the position it will collect the most sunlight throughout the day.Tighten screws at the desired position. �. •/fir �� r i � � . This Natural Light Solar Attic Fan has a 25 year warranty on the housing, the solar panel and the inotor. .......... PLEASE COMPLETE AND MAIL THE CARD BELOW AS SOON AS YOUR SOLAR ATTIC FAN IS INSTALLED.This card will serve as proof of your purchase, should you misplace your original invoice- The manufacturer warrants this product to be free from defects in material and manufacturer's workmanship for a period of 25 years an the motor, the solar panel and the housing, from the date of installation. This warranty is subject to proper installation of the unit in accordance with the manufacturer's written installation instructions.The manufacturer will not be liable for any special, incidental or consequential damages in any way related to, or arising out of, defects in, or damage to,the solar attic fan. This warranty gives you specific legal rights, and you may have other rights which vary from state to state concerning exclusion or limitation of incidental or consequential damages. X. fie Please fill out the form below and mail it to: Natural Light Energy Systems o10821 North 23rd Avenue ° Phoenix, AZ 85029 ______________________________________________________ Natus8Ught5n|orAtticFon |nstnUer Date ofPurchase: Customer Name: Address: City: State: Zip: Customer Survey Are you satisfied with the performance? Y N What made you choose our product? Were you satisfied with the installation job? Florida Building Code Online Page 1 of 2 FILE r;fI.�0j�;r;1 �lG SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map Links N Search Busines.��!, Professional @USER PcIAUser pproval Regulation Product Approval Menu>Product or Application Search>Application List>Application Detail .- FL# FL13509-R3 Application Type Affirmation Code Version 2014 Application Status Validated Comments Archived Product Manufacturer NATURAL LIGHT ENERGY SYSTEMS Address/Phone/Email 10821 N.23rd Ave. PHOENIX,AZ 85029 (813)909-1956 bolsonl@tampabay.rr.com Authorized Signature Kelly Joya kelly@nitubular.com Technical Representative Gregg Vincent Address/Phone/Email 10821 N.23rd Ave. Phoenix,AZ 85029 (602)485-5984 gvincent@nitubular.com Quality Assurance Representative Mark Orszulak Address/Phone/Email 10821 N.23rd.Ave. Phoenix,AZ 85029 (602)485-5984 Mark@nitubular.com Category Roofing Subcategory Roofing Accessories that are an Integral Part of the Roofing System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer - Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Allen Douglas Gezelman Evaluation Report Florida License PE-59180 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By James Tippens,PE Validation Checklist-Hardcopy Received Certificate of Independence FL13509 R3 COI FL13509 R2 COI.odf Referenced Standard and Year(of Standard) Standard Year ASTM E330 2002 TAS 100A 1995 TAS 202 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL13509 R3 Eouiv FL13509 R2 EOUIVALENCY.pdf lhttns://www.floridabuildiniz.org/Dr/Dr ann dtl.aspx?t)aram=wGEVXQwtDquynOPErOHee... 7/15/2015 131orida Building Code Online Page 2 of 2 Sections from the Code I affirm that there are no changes in the new Florida Building Code which affect my product(s)and my product(s) are in compliance with the new Florida Building Code. Documentation from approved Evaluation or Validation Entity - Yes No N/A FL13509 R3 COC FL13509 PE 2014 FBC AFFIRMATION (1).pdf Product Approval Method Method 1 Option D Date Submitted 07/08/2015 Date Validated 07/08/2015 Summary of Products FL# Model,Number or Name Description 13509.1 NATURAL LIGHT ENERGY SYSTEMS NLES ROOF-MOUNTED PV ATTIC FAN PHOTO-VOLTAIC ATTIC FANS Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL13509 R3 II 0192P AG NLT-R3.pdf Approved for use outside HVHZ:Yes Verified By:Allen Gezelman PE 59180 Impact Resistant:Yes Created by Independent Third Party: No Design Pressure:+86.5/-175 Evaluation Reports Other: FL13509 R3 AE PCA 13509.2 EVALUATION REPORT.Ddf Created by Independent Third Party: No 13509.2 NATURAL LIGHT ENERGY SYSTEMS NATURAL LIGHT ENERGY SYSTEMS PHOTO-VOLTAIC ATTIC PHOTO-VOLTAIC ATTIC FANS FANS Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL13509 R3 II PV ATTIC FAN INSTALLATION Approved for use outside HVHZ:Yes INSTRUCTIONS.pdf Impact Resistant:Yes Verified By: PROFESSIONAL ENGINEER FL 59180 Design Pressure:+86.5/-175 Created by Independent Third Party: No Other:LIMITED TO WOOD ROOF DECKS Evaluation Reports FL13SO9 R3 AE PV ATTIC FAN EVALUATION REPORT.pdf FL13509 R3 AE SAF E330-A8071 01-301-44-RO.Ddf FL13SO9 R3 AE TAS202-A8071 02-301-18-RO(2).odf Created by Independent Third Party: No 13509.3 NLES ROOF-MOUNTED PV ATTIC NATURAL LIGHT ENERGY SYSTEMS PHOTO-VOLTAIC ATTIC FAN FANS Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL13509 R3 II 0192P AG NLT-R3.pdf Approved for use outside HVHZ:Yes Verified By: LICENSED PE PE59180 Impact Resistant:Yes Created by Independent Third Party: No Design Pressure:+86.5/--175 Evaluation Reports Other: FL13509 R3 AE FL13509 R2 AE FL13509- R2 EVALUATION old.odf Created by Independent Third Party: No Back Next Contact Us::1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If - they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: Fc AR fcrE:�. sccuritc.}:i'rr,ics httns://www.floridabuildina.ora/Dr/ter aDD dtl.aspx?uaram=wGEVXQwtDquynOPErOHee... 7/15/2015