HomeMy WebLinkAboutProduct Approval (2) R: 2M FILE Copy
toli
NIIA V11-RADE COUNTY
MIAMI. i PRODUCT CONTROL SECTION
a ,�� � 11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami.florid:►33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 1'(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miami(In de.V'o"le Coll onw
GAF
1 Campus Drive
Parsippany,NJ W054
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Flavins.lurisdiction (AVIJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control
Section (In Miami Dade. County) and/or the AFIJ (in areas other than Miami-Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AFIJ may immediately
revoke,.inodil'y, or susl end the use of such product or material within their jurisdiction. RER reserves the right to
revoke this acceptance, if it is determined by Miami=Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the l Iigh Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTIONS GAF Timberline 116',Timberline Natural Shadow",and Timberline American Hal-vest10
Shingles
LABELING: Each unit shall bear a permanent label with the manufacturer's name or lotto, city,state and:following
statement: "Miarni-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL,of this NOA shall be considered after a renewal application has been tiled and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials' use;and/or manufacture of the product or process. Misuse of this NOA as-an endorsement of any product,
for sales, advertising or any other purposes sliall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising 1.iterature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available toe inspection at the job site at the request of the Building Official.
This NOA revises NOA 13-0419.04 and consists of pages 1 through 6.
The submiacddocumentation was reviewed by Juan E. Collao, R.A.
NOA No.: 14-1022.20
MIAMI•DADECOUNTY { Expiration Date: 02/21/17
!' Approval Date: 02/05/15
,' Page I of 6
ROOFING ASSEMBLY APPROVAL*
Catemoi�y: Rooting
Sub-Catel!01-y: Asphalt Shingles
Materials- Laminate
Deck Type: Wood
SCOPE
This approves GAF Timbei-line HV%Timberline Natural Shadow*,and Timberline American Harvest"'
Shingles as 11111111LIffictured by GAF as described:in Section 2 of this Notice of Acceptance.
PRODUCT DESCRIPTION
Product Dimensions Test Product Description
Specifications
GAF Timberline HD"' 13 x 39'/a' TAS 110 Fiberglass reinforced heavy weight asphalt
Man fudfdj-ing roof shingle,with a laminate profile
Locations#1,2,3,4,5,6,7
GAF Timberline Natural 13 x 39 3/8" TAS 110 Fiberglass reinforced heavy weight asphalt
S hadow4' roof shingle,with a laminate profile
A,fanufcic1w-in,q
Locations#l,2,3,4,5,6,7
GAF Timberline American 13 141"x 39'!R TAS 110 Fiberglass reinforced heavy weight asphalt
Harvest, roof shingle, with a laminate profile
J111alulfc1clul-ing
Locutions#2,4,5,6
MANUFACTURING LOCATION
1. Tampa, FL
2. Michigan City, N
3. Baltimore, MD
.4. Nlyerstown, PA
5. Ennis,TX
6. Tuscaloosa, AL
7. Dallas,TX
A
NOA No.: 14-1022.20 AMI-DADE COUPT-ft
I
uaqvulkmmw Expiration Date:02/21/17
Approval Date:02/05/15
Page 2 of 6
EVIDENCE SUBMITTED
Test Agency Test Identifier Test Name/Rcnort Date
Underwriters Laboratories, file. ASTM D3462 1 ICA4:8924 10/24/11
Underwriters Laboratories, Inc ASTM D3462 IOCA21994 04/22/11
Underwriters Laboratories, Inc ASTM D3462 10CA287°17 07/26/11
Underwriters Laboratories,Inc. ASTM D3462 05CA47541 11/10/06
Underwriters Laboratories, [tic. ASTM D3462 06CA3:1580 11/30/06
PRI Asphalt Technologies, file. ASTM D3462 GAF-101-O2-M2 11/02/05
Underwriters Laboratories, [tic. ASTM D3462 06NK05(59 08/09/06
PRI Asphalt Technologies,Inc. ASTM D3462 GAF-098-02-02 11/08/05
Underwriters,Laboratories, Inc. ASTM D3462 02NK41809 08/11/02
Underwriters Laboratories, Inc. ASTM 133462 03NK26444 10/1.7/03
Center for Applied Engineering ASTM D3462 257099 05/13/97
Underwriters Laboratories, Inc. TAS 107 OINK45803 04/13%94
Underwriters'Lab pratories, Inc. TAS 107 06N.KO5159 08/09/06
Underwriters Laboratories, Inc. TAS 107 04NK04273 02/20/04
Underwriters Laboratories, Inc. TAS 107 05CA-42840 l 1/1 1/05
Underwriters-Laboratories, Inc. TAS 107 02NK41:81 1 I t/I 1/02
Underwriters Laboratories, Inc. TAS 107 03CA35209 10/17/03
Underwriters Laboratories, [tic. TAS 107 04CA13:850 08/30/04
Center.for Applied Engineering TAS 100 257989 04/01/97
PRI Asphalt Technologies, Inc. TAS 100 GAF-044-02-01 01/13/04
PRI Asphalt Technologies, Inc. TAS 100 GAF-098-02-01 11/08/05
PRI Asphalt Technologies, Inc. TAS 100 GAF-1.01-02-01 11/09/05
PRI Asphalt Technologies, Inc. TAS 100 GAF-I 16-02-02 03/23/06
PRI Asphalt Technologies, Inc. TAS-100 ELIC-083-02-01 10/16/02
ELK-084:-02-01 10/15/01-1
ELK-085-02-01 10/14/02
ELK-086-02-01 10/24/02
ELK-087-02-01 10/21/02
ELK-088-02-01 10/16/02
ELK-107-02-01 10/09/03
ELK-108-02-01 10/09/03
ELK-109-02-01 10109/03
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
[ire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61 G20-3 of the Florida Administrative Code.
NOA No.: 141022.2(1
MIAMf•DADECOUNTY Expiration Date: 02/21/17
Approval Date: 02/05/15
Page 3 oi'6
INSTALLATION
1.. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS HS
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout:shall be in compliance with Detail 'A', attached.
5. Nailing shall be in compliance with Detail'B', attached.
LABELING
Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of
manufacturing facility, and following statement: "Nliami-Dade County Product Control Approved" or the Miami-Dade
County Product Control Seal as shown below.
MIAMI DADE COUNTYIN
BUILDING PERMIT REQUIREMENTS
1. Application for building permit shall be accompanied by copies of the following-
1.1
ollowing:1.l This Notice of Acceptance.
1.2 Any other documents "required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
NOA No.: 14-1022.20
MIAMI•DADECOUNTY Expiration Date: 02/21/17
Approval Date: 02/05/15
Page 4 of 6
DETAIL A
COURSE }LA•YOUT
DECK
FULL
5th
17"OFF 4th
11"OFF 3rd
6" OFF 2nd
FULL 1st
gi[MIAMI-DADE COUNTY-10
NOA No.: 14-1022.20
i Expiration Date:02121./17
Approval Date:02/05/15
Page 5 orb
DETAIL B
OVERALL DIMENSIONS AND NAILING PATTERN
39-3/811
(tm)
14-1/2"-17-1/2" 1W 411 14-1/2"-17-1/2" —r–
(368-445mm) (368-445mm) ail guide line
6-1/2"-9-1/2" 6-1l2"-9-1l2" 53/4"-6-114'
11 1165-241-1 1165-241—)
13-1/4 1n .� ...� .-�- ♦— (14 6mm-159mm)
irr-2-vt from bottom of shingle
j1a-w
elf seal
adhesive
on back
ENHANCED NAILING PATTERN - six nails per shingle*
required by some local codes and required for enhanced wind coverage on certain products.
See limited warranty for details.
These shingles MUST be nailed a nominal 6" (152mm)from bottom of
of.shingle, above the cut outs, as shown. Nails mustnot be exposed.
END OF THIS ACCEPTANCE
NOA No.: 14-1022.20
MIAMI•DADECOUNTY Expiration Date: 02/21/17
• ' Approval Date: 02/05/15
Page 6 of 6