Loading...
HomeMy WebLinkAboutNotice of Acceptance File .Copy MIA?41�20WE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT(BNC) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 ww NOTICE OF ACCEPTANCE (NOA) w.miamidade.QovJbgildineJ Owens Corning Roofing and Asphalt,LLC One Owens Corning ParWay Toledo,OH 43659 SCOPE: This NOA is being issued under the applicable.rules and regulations governing the use of construction materials. The documentation submitted has Veen reviewed and accepted by Miami-Dade County BNC-Product Control Section to be used in Miami Dade,County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Produ6t Control Section(In Miami Dade County)and/or the AHJ (in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fail's to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Oakridge®Shingle LABELING: Each unit shall bear a permanent label with the manufacturees name or logo,city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal Application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other•purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal-of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida, and followed by the expiration date,may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA# 10-1015.01 and consists of pages I through 4. The submitted documentation was reviewed by Alex Tigera. NOA No.:11-0411.03 MIAMMADECOUNW Expiration Date:02/03/16 Approval Date:06116/11 Page 1 of 4 ROOFING ASSEMBLY APPROVAL Category Roofing Sub-Categorv: Asphalt Shingles Materials Laminate Deck Type: Wood SCOPE This approves a roofing system using Owens Corning Oakridge®asphalt shingles manufactured by Owens Corning as described in Section 2 of his Notice of Acceptance. PRODUCT DESCRIPTION Product Dimensions Test Product Description Specifications Oakridge® 13 'W'x 39 3/8" TAS 110 A heavy weight,fiberglass reinforced Manufacturing laminate asphalt shingle with continuous Locations#1,2,3,4 bead of sealant. Oakridge® 13 '/a"x 39 3/8" TAS 110 A heavy weight,fiberglass reinforced Manufacturing laminate asphalt shingle with dashed bead of Location#1,3,4 sealant. MANUFACTURING LOCATION 1. Memphis,TN 2. Irving,TX 3. Savannah,GA 4. Jacksonville,FL EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date PRI Construction Materials Technologies OCF-15 3-02-01 TAS 100 09/22/10 PRI Construction Materials Technologies OCF-152-02-01 TAS 100 09/21/10 PRI Construction Materials Technologies OCF-158-02-01 TAS 100 11/10/10 PRI Construction Materials Technologies. OCF-151-02-01 TAS 100 09/27/10 PRI Construction Materials Technologies OCF-15 0-02-01 TAS 100 09/21/10 PRI Construction Materials Technologies OCF-165-02-01 TAS 100 01/07/11 PRI Construction Materials Technologies OCF-170-02-01 TAS 100 06/06/11 Underwriters Laboratories 09NK14530 ASTM D 3462 12/31/09 Underwriters Laboratories R2453 ASTM D 3462 10/11/10 Underwriters Laboratories 82453 ASTM D 3462 11/03/10 Underwriters Laboratories R2453 ASTM D 3462 10/11/10 Underwriters Laboratories R2453 ASTM D 3462 10/11/10 Underwriters Laboratories R2453 ASTM E 108 01/13/11 Underwriters Laboratories R2453 ASTM E 108 10/11/10 Underwriters Laboratories R2453 ASTM E 108 11/03/10 NOA No.: 11-0411.03 MrAriNr�4na couNry Expiration Date:02/03/16 Approval Date:06/16/11 Page 2 of 4 Underwriters Laboratories 82453 ASTM E 108 10/11/10 Underwriters Laboratories 82453 ASTM E 108 10/11/10 Underwriters Laboratories 09NK14530 TAS 107(ASTM D 316 1) 12/31/09 Underwriters Laboratories OINK44201 TAS 107(ASTM D 316 1) 09/09/02 Underwriters Laboratories 1ONK13947 TAS 107(ASTM D 3161) 11/12/10 Underwriters Laboratories 82453 TAS 107(ASTM D 316 1) 10/11/10 Underwriters Laboratories 03NK04954 TAS 107(ASTM D 316 1) 03/07/03 Underwriters Laboratories IONK13947 TAS 107(ASTM D 316 1) 01/28/11 Underwriters Laboratories 11CA15662 TAS 107(ASTM D-3161) 05/27/11 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B-72 of the Florida Administrative Code. INSTALLATION 1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail'A',attached. 5. Nailing shall be in compliance with Detail TB,attached. LABELING 1. Shingles shall be labeled with*the Miami-Dade Seadl as seen below,or the wording"Miami-Dade County Product Control Approved". MIAMI-DADS COUNTY ��IF_11122,.Kjaj BUILDING PERMIT REQUIREMENTS 1, Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. NOA No.: 11-0411.03 MIAMI-DADECOU Expiration Date:02/03/16 Approval Date:06/16/11 Page 3 of 4 DETAIL A EDGE OF ROOF ------ OWENS CORNING OAKRIDGE OAKRIDGE �--- 18-11T i i3 � THIRD COURSE i + gQ_ . SECOND COURSE i i i FIRST COURSE DETAIL B OWENS CORNING OAKRIDGE WITH CONTINUOUS OR DASHED SEALANT 39 3/8" 2" 2" 1111 1" 13-1/4" 58�- 5 5/8" EXPOSURE END OF THIS ACCEPTANCE NOA No,: 11-0411.03 MIAMI•DAD>E COUNTY Expiration Date: 02/03/16 Approval Date: 06/16/11 Page 4 of 4