HomeMy WebLinkAboutNotice of Acceptance File .Copy
MIA?41�20WE MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT(BNC) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
ww
NOTICE OF ACCEPTANCE (NOA) w.miamidade.QovJbgildineJ
Owens Corning Roofing and Asphalt,LLC
One Owens Corning ParWay
Toledo,OH 43659
SCOPE:
This NOA is being issued under the applicable.rules and regulations governing the use of construction materials.
The documentation submitted has Veen reviewed and accepted by Miami-Dade County BNC-Product Control
Section to be used in Miami Dade,County and other areas where allowed by the Authority Having Jurisdiction
(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Produ6t Control
Section(In Miami Dade County)and/or the AHJ (in areas other than Miami Dade County)reserve the right
to have this product or material tested for quality assurance purposes. If this product or material fails to
perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may
immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC
reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control
Section that this product or material fail's to meet the requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Oakridge®Shingle
LABELING: Each unit shall bear a permanent label with the manufacturees name or logo,city,state and
following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal Application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any
product,for sales,advertising or any other•purposes shall automatically terminate this NOA.Failure to comply
with any section of this NOA shall be cause for termination and removal-of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida, and followed by
the expiration date,may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall
be done in its entirety.
INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This revises NOA# 10-1015.01 and consists of pages I through 4.
The submitted documentation was reviewed by Alex Tigera.
NOA No.:11-0411.03
MIAMMADECOUNW Expiration Date:02/03/16
Approval Date:06116/11
Page 1 of 4
ROOFING ASSEMBLY APPROVAL
Category Roofing
Sub-Categorv: Asphalt Shingles
Materials Laminate
Deck Type: Wood
SCOPE
This approves a roofing system using Owens Corning Oakridge®asphalt shingles manufactured by Owens
Corning as described in Section 2 of his Notice of Acceptance.
PRODUCT DESCRIPTION
Product Dimensions Test Product Description
Specifications
Oakridge® 13 'W'x 39 3/8" TAS 110 A heavy weight,fiberglass reinforced
Manufacturing laminate asphalt shingle with continuous
Locations#1,2,3,4 bead of sealant.
Oakridge® 13 '/a"x 39 3/8" TAS 110 A heavy weight,fiberglass reinforced
Manufacturing laminate asphalt shingle with dashed bead of
Location#1,3,4 sealant.
MANUFACTURING LOCATION
1. Memphis,TN
2. Irving,TX
3. Savannah,GA
4. Jacksonville,FL
EVIDENCE SUBMITTED
Test Agency Test Identifier Test Name/Report Date
PRI Construction Materials Technologies OCF-15 3-02-01 TAS 100 09/22/10
PRI Construction Materials Technologies OCF-152-02-01 TAS 100 09/21/10
PRI Construction Materials Technologies OCF-158-02-01 TAS 100 11/10/10
PRI Construction Materials Technologies. OCF-151-02-01 TAS 100 09/27/10
PRI Construction Materials Technologies OCF-15 0-02-01 TAS 100 09/21/10
PRI Construction Materials Technologies OCF-165-02-01 TAS 100 01/07/11
PRI Construction Materials Technologies OCF-170-02-01 TAS 100 06/06/11
Underwriters Laboratories 09NK14530 ASTM D 3462 12/31/09
Underwriters Laboratories R2453 ASTM D 3462 10/11/10
Underwriters Laboratories 82453 ASTM D 3462 11/03/10
Underwriters Laboratories R2453 ASTM D 3462 10/11/10
Underwriters Laboratories R2453 ASTM D 3462 10/11/10
Underwriters Laboratories R2453 ASTM E 108 01/13/11
Underwriters Laboratories R2453 ASTM E 108 10/11/10
Underwriters Laboratories R2453 ASTM E 108 11/03/10
NOA No.: 11-0411.03
MrAriNr�4na couNry Expiration Date:02/03/16
Approval Date:06/16/11
Page 2 of 4
Underwriters Laboratories 82453 ASTM E 108 10/11/10
Underwriters Laboratories 82453 ASTM E 108 10/11/10
Underwriters Laboratories 09NK14530 TAS 107(ASTM D 316 1) 12/31/09
Underwriters Laboratories OINK44201 TAS 107(ASTM D 316 1) 09/09/02
Underwriters Laboratories 1ONK13947 TAS 107(ASTM D 3161) 11/12/10
Underwriters Laboratories 82453 TAS 107(ASTM D 316 1) 10/11/10
Underwriters Laboratories 03NK04954 TAS 107(ASTM D 316 1) 03/07/03
Underwriters Laboratories IONK13947 TAS 107(ASTM D 316 1) 01/28/11
Underwriters Laboratories 11CA15662 TAS 107(ASTM D-3161) 05/27/11
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory
for fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building
Code and Rule 9B-72 of the Florida Administrative Code.
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail'A',attached.
5. Nailing shall be in compliance with Detail TB,attached.
LABELING
1. Shingles shall be labeled with*the Miami-Dade Seadl as seen below,or the wording"Miami-Dade County
Product Control Approved".
MIAMI-DADS COUNTY
��IF_11122,.Kjaj
BUILDING PERMIT REQUIREMENTS
1, Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
NOA No.: 11-0411.03
MIAMI-DADECOU Expiration Date:02/03/16
Approval Date:06/16/11
Page 3 of 4
DETAIL A
EDGE OF ROOF
------ OWENS CORNING OAKRIDGE
OAKRIDGE
�--- 18-11T
i
i3
� THIRD COURSE
i + gQ_ .
SECOND COURSE
i
i
i
FIRST COURSE
DETAIL B
OWENS CORNING OAKRIDGE
WITH CONTINUOUS OR DASHED SEALANT
39 3/8"
2" 2" 1111 1"
13-1/4"
58�-
5 5/8" EXPOSURE
END OF THIS ACCEPTANCE
NOA No,: 11-0411.03
MIAMI•DAD>E COUNTY Expiration Date: 02/03/16