Wind Load Calculation
JONES R E C E IIV'-'7D DEC 9156 PUMPKIN RIDGE RD1 201 PORT ST LUCIE, FL Building height Zone 4 re 15 20 25 30 35 40 45 50 55 60 10 pos 7.9 40.4 42.3 43.8 45.4 46.7 47.9 48.9 49.8 50.7 neg 1.] 43.8 45.9 47.5 49.2 50.6 52 53 54 55 20 pos 6.3 38.7 40.5 42 43.5 44.7 45.9 46.8 47.7 48.6 neg 1 '9' 42 44 45.6 47.2 48.5 49.8 50.8 51.8 52.8 50 pos S. 37.7 39.4 40.9 42.4 43.5 . 44.7 45.6 46.5 47.3 neg 7.1. 39.6 41.4 42.9 44.5 45.7 46.9 47.8 48.7 49.7 \100 pas 32.2 34.4 36 37.3 38.6 39.7 40.8 41.6 42.4 43.2 neg 35.4 37.8 39.5 41 42.5 43.6 44.8 45.7 46.6 47.4 500 pas 28.2 30.1 31.5 32.7 33.8 34.8 35.7 36.4 37.1 37.8 neg 31.4 33.5 35.1 36.4 37.7 38.7 40.5 39.7 41.3 42.1 Building height End zone 5 15 20 25 30 35 40 45 50 55 60 10 pas. 37.9 40.4 42.3 43.8 45.4 46.7 47.9 48.9 49.8 50.7 neg 50.7 54.1 56.6 58.7 60.8 62.5 64.2 65.4 66.7 67.9 20 pos 36.3 38.7 40.5 42 43.5 44.7 45.9 46.8 47.7 48.6 neg 47.3 50.5 52.8 54.8 56.7 58.3 59.8 61 62.2 63.4 50 pos 35.4 37.7 39.4 40.9 42.4 43.5 44.7 45.6 46.5 47.3 neg 42.8 45.6 47.7 49.5 51.2 52.7 54.1 55.1 56.2 57.3 100 pos 32.2 34.4 36 37.3 38.6 39.7 40.8 41.6 42.4 43.2 neg 39.4 42 44 45.6 47.2 48.5 49.8 50.8 51.8 52.8 500 pos 28.2 30.1 31.5 32.7 33.8 34.8 35.7 36.4 37.1 37.8 neg 31.4 33.5 35.1 36.4 37.7 38.7 39.7 40.5 41.3 1 42.1 Wind design Pressure Chart for structures subject to Florida Residential Code 170 mph exposure C Wall component and Cladding pressures from Table R302.2(2) modified by adjustment factors from R301.1(3). Converted to Vasd according to R302.1.2.1.1