HomeMy WebLinkAboutEngineering COOK & MENARD ARCHITECTURE INC.
'806 Delaware Avenue, Fort Pierce, Florida 34950
PHONE(772)460-7751 FAX(772)460-4244
EMAIL cookmenard@yahoo.com
November 25, 2015
#i1e Copy
Saint Lucie County Building Department
Attn: Roof Permit Plan Review
2300 Virginia Avenue
Ft. Pierce, FL 34982
Re: Roofing specification prepared for the St. Lucie County Building Dept.for the structure located at,
10420 Glades Cut off Rd.,Saint Lucie County, Florida
Manufacturer: Gulf Coast Supply& Manufacturing
Profiles: 24 GA GuIfPBR Roof Panel FL#11650.2
Code: FBC 2014;Section R 905.10
Wind Speed: 160 MPH; Ultimate Design Wind Speeds
Exposure: B
Mean Roof Height: 30' Maximum
Pitch: 1/12
Required Design Pressure: Zonel:-38.2 Zone 2: -53.9 Zone3:-101.4
Maximum Uplift Pressure: Fastener spacing:-60psf @ 5"o.c. zone 1 & 2, -150 psf @ 2" o.c.zone 3
Fasteners: #12-14 X 1-1/4" HWH SD with sealing washer @ 12"o.c. with'/," minimum
penetration
Roof Decking: Existing plywood sheathing to be nailed w/8d x2"ring shank nails @ 6" o.c.thru
out Zone 1,4! 6.c. perimeter& 6"o.c. field Zone 2,and 4" o.c.thru out Zone3
The above approved,as per Florida Building Code Compliance acceptances, 2014 Florida Building Code, and the
Manufacturer's recommendations.
Respectfully Submitted.
Peter B.Cook
Cook&Menard Architecture, Inc.
Florida Registration No. AA0003494, NCARB Certification No. 31789