HomeMy WebLinkAboutEngineering COOK & MENARD ARCHITECTURE INC. '806 Delaware Avenue, Fort Pierce, Florida 34950 PHONE(772)460-7751 FAX(772)460-4244 EMAIL cookmenard@yahoo.com November 25, 2015 #i1e Copy Saint Lucie County Building Department Attn: Roof Permit Plan Review 2300 Virginia Avenue Ft. Pierce, FL 34982 Re: Roofing specification prepared for the St. Lucie County Building Dept.for the structure located at, 10420 Glades Cut off Rd.,Saint Lucie County, Florida Manufacturer: Gulf Coast Supply& Manufacturing Profiles: 24 GA GuIfPBR Roof Panel FL#11650.2 Code: FBC 2014;Section R 905.10 Wind Speed: 160 MPH; Ultimate Design Wind Speeds Exposure: B Mean Roof Height: 30' Maximum Pitch: 1/12 Required Design Pressure: Zonel:-38.2 Zone 2: -53.9 Zone3:-101.4 Maximum Uplift Pressure: Fastener spacing:-60psf @ 5"o.c. zone 1 & 2, -150 psf @ 2" o.c.zone 3 Fasteners: #12-14 X 1-1/4" HWH SD with sealing washer @ 12"o.c. with'/," minimum penetration Roof Decking: Existing plywood sheathing to be nailed w/8d x2"ring shank nails @ 6" o.c.thru out Zone 1,4! 6.c. perimeter& 6"o.c. field Zone 2,and 4" o.c.thru out Zone3 The above approved,as per Florida Building Code Compliance acceptances, 2014 Florida Building Code, and the Manufacturer's recommendations. Respectfully Submitted. Peter B.Cook Cook&Menard Architecture, Inc. Florida Registration No. AA0003494, NCARB Certification No. 31789