_ _ FL# FL11650-R2
L",T Application Type Revision
Code Version Z211�
Application Status Approved
Comments
Archived
Product Manufacturer Gulf Coast Supply&Manufacturing,LLC.
Address/Phone/Email 4020 S.W.449th Street
Horseshoe Beach,FL 32648
(352)498-7852
ray@gulfcoastsupply.com
Authorized Signature Ray Bowen
my@guIkoastsupply.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Structural Components
Subcategory Roof Deck
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Evaluation Report Daniel S.Kuhn
Florida License PE-75519
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 04/12/2024
Validated By Locke Bowden
I Validation Checklist-Hardcopy Received
Certificate of Independence FL11650 R2 COI Cert of Ind Kuhn Eno.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM E 1592 2005
FM 4471 1992
FM 4471 1992
TAS 125 2003
TAS 201 1994
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 07/28/2015
Date Validated 08/06/2015
Date Pending FBC Approval 08/15/2015
Date Approved 10/16/2015
Summary of Products
FL# Model,Number or Name Description
11650.1 24 Ga Gulf Coast Megaloc 24 Ga.Gulf Coast Megaloc 18"Wide Roof Panel over open framing
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL11650 R2 II 14F-11650 1 R2 24MegaLoc18 Metal Roof Detail.odf
Approved for use outside HVHZ:Yes FL11650 R2 11 14FL11650 I R2 24MegaLoc18 Open Framing pdf
Impact Resistant:N/A Verified By:Dan S.Kuhn,P.E.75519
Design Pressure:+N/A/-120.0PSF Created by Independent Third Party:Yes
Other:-45.0 psf @ 5'-0"o.c.clip spacing.-120.0 psf @ V-0"o.c.clip spacing.Install Evaluation Reports
per manufacturers details.Not for use in HVHZ Zones. FL11650 R2 AE 14FL11650 1 R2 24Menal-oc18 Open Framinci.odf
Created by Independent Third Party:Yes
:)f2 12/1/2015,11:05 AM
lorida Building Code Online http://www.tloridabuilding.org/pr/pr_app_4t[.aspx'!param=w(iEVX...
! 11650.2 24 Ga.GuIfPBR Roof Panel 24 Ga.Gulf PBR Roof Panel over open framing
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FLS 1650 R2 IS 14FL11650 2 R2 24GuIfPBR Metal Roof Detail Of
Approved for use outside HVHZ:Yes FL11650 R2 it 14FL11650 2 R7 24GuIfPBR Onen Ftaminl�ndf
Impact Resistant:N/A Verified By:Dan S.Kuhn,P.E.75519
Design Pressure:+N/A/-150.OPSF Created by Independent Third Party:Yes
Other:-60.0 psf @ 5'-0"o.c.fastener spacing.-150.0 psf @ 2'-0"o.c.fastener spacing. Evaluation Reports
Install per manufacturers details.For use In HVHZ Zones. FL11650 R2 AE 14FL11650 2 R2 24GuIfPBR Oven Frdminn odf
Created by Independent Third Party:Yes
11650.3 26 Ga.Gu1fPBR Roof Panel 26 Ga.GuIfPBR Roof Panel over open framing
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL11650 R2 II 14FL11650 3 R2 26GulfPBR Metal Roof Detail.vdf
Approved for use outside HVHZ:Yes FL11650 R2 If 14FL11650 3 R2 26GulfPBR Oven Framing vdf
Impact Resistant:N/A Verified By:Dan S.Kuhn,P.E.75519
Design Pressure:+N/A/-40.0 PSF Created by Independent Third Party:Yes
Other:-40.0 psf @ 5'-0"o.c.fastener spacing.Install per manufacturers details.Not for Evaluation Reports
use in HVHZ Zones. FL11650 R2 AE 14FL11650 3 R2 26GuIfPBR Oven Framina.ndf
Created by Independent Third Party:Yes
Bads NetR
orae[n.::1Qd0 North Menree Stine!T.Raha..e" 39e phnnn�05e-4B7-182d
The State of Florida k-AA/EEO employer.r.evrivht 200]-)013 State of Florida.;;PrNan Statement;:Ac •Nhl�n A f m
Under Floridalaw,emalladdresses are public records.ayou do cot want your a-mad address rebased in response to a pubk-records request,do not send electronic matte this entity.Instead,contact the office by phone orby traditionalmad.
If you have any 4uestiom,please contact 850.487.1395.•pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees k,m,d under Chapter 455,F.S.must provide the Department wkb an emailaddress I they
have—.Th,—Is provided may be used far affidal communication with the funs...However.mall addresses are public record.Ifyou do not wish to supply a personal address,please pnvlde the Dapartmere with an email address whkh
can be made available to the public.To determine r you are a kensee under Chapter 455,F.S.,please click here.
ProductApproval Accepts:
of 12/1/2015 11:05 AM
Force Engieering&Testing Inc.
1953n0 Ramblemood Drive
Humble,TX 77338
Product Evaluation Report
GULF COAST SUPPLY& MANUFACTURING, LLC.
24 Ga. PBR Roof Panel over open framing
Florida Product Approval # 11650.2 R1
Florida Building Code 2010
Per Rule 9N-3
Method:1—D
Category:Structural Components
Subcategory: Roof Deck
Compliance Method:9N-3.005(1)(d)
HVHZ
Product Manufacturer:
Gulf Coast Supply&Manufacturing,LLC.
4020 S.W.449`h Street
Horseshoe Beach,Florida 32648
Engineer Evaluator:
Terrence E.Wolfe,P.E.#44923
Florida Evaluation ANE ID:1920
Validator:
Locke Bowden,P.E.,FL#49704
9450 Alysbury Place
Montgomery,AL 36117
Contents:
Evaluation Report Pages 1—5
, isII111'r��i
% N•C E,
�`,�� � I C r
No.440
fes} ���_-}}} : �
•a• STATE OF ;
k, •
00' ;K- AZoRIIDA "(4t '%44'
M�psna
F1.#11650.2 R1 February 17, 2012
Force Engineering&.:Testing Inc.
19530 Ramb[ewood Drive
Humble,TY,77338
Compliance Statement: The product as described in this report has demonstrated compliance with the
Florida Building Code 2010,Sections 1504.3.2,1504.7,1518.9.
Product Description: PBR Roof Panel, 24 Ga. Steel, 36"Wide,through fastened structural roof panel.
Structural Application.
Panel Material/Standards: Material: 24 Ga.Steel,ASTM A792 or ASTM A653 G90 conforming to Florida
Building Code 2010 Section 1507.4.3.
Paint Coating: Valspar Fluropon Coating(Optional)
Yield Strength: Min.50.0 ksi
Corrosion Resistance:Panel Material shall comply with Florida Building Code
2010,Section 1507.4.3
Panel Dimension(s): Thickness: 0.0235"min.
Width: 36"
Rib Height: 1%"major rib at 12"O.C.
Panel Rollformer: MRS Metal Rollforming Systems
Panel Fastener: #12-14 x 1-1/4" HWH SD with sealing washing or approved equal at 12"-12"-12"
fastener pattern. Panel side laps fastened together w/%-14 x 7/8" HWH SD w/
sealer washer at 18"O.C.
Corrosion Resistance:Per Florida Building Code 2010,Section 1506.6,1507.4.4
Substrate Description: Min.16 Ga.Steel Framing. Must be designed in accordance w/Florida Building
Code 2010.
C
16
l No.47 / •.��tl ` f
0/ /
STATE of ;a
smw pie, �4PA. PE`s;•, �1���
omm
FL,#11650.2 R1 February 17, 2012
Force Eagineering&'T'esting Inc.
19530 Ramblewood 17rivc
Hunlble,TX 77338
Design Uplift Pressures: Maximum Allowable Uplift Pressures Based on ASTM E 1592 Testing:
-60.0 psf at 5'-0"O.C.(12"-12"-12"fastener pattern)
-150.0 psf at 2'-0"O.C.(12"-12"-12"fastener pattern)
The Following are Panel Allowable for Uplift Pressures Based on ASTM E 1592
Testing:
Maximum Bending Moment of the panel at Support:119.6 lbs-ft
Maximum Bending Moment of the panel at Mid Span:86.2 lbs-ft
Maximum Panel Interior Support Reaction:207.2 lbs
Maximum Panel Exterior Support Reaction:87.7 lbs
Maximum Allowable Deflection of Roof Panel=L/240
Panel EI Value:1,253,772 lbs-int
Code Compliance: The product described herein has demonstrated compliance with
The Florida Building Code 2010,Section 1504.3.2,1504.7,1518.9.
Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Code 2010,as relates to Rule 9N-3.
Performance Standards: The product described herein has demonstrated compliance with:
■ TAS 125-03
■ ASTM E 1592-01 Test method for structural performance of sheet metal
roof and siding systems by uniform static air pressure difference.
® TAS 201-94-Impact Testing
■ FM 4471 Appendix G for roof slopes less than 2:12.
TAS 110-00-Accel.Weathering ASTM G 26/Salt Spray ASTM B 117
■ FM 4471,Section 4.4-Foot Traffic Resistance Test.
toll It11f11J..1
tt C-E. E:, W�iifi
Iq
.� rl
No.440
STATE OF :a
s,n.er�oea. �� FS., •1 ♦�
o s eel, "� I lit
FL#11650.2 Rl
February 17, 2012
rForcce eering&Testing Lic.
19530 Ramblewood Drive
Humble,TX 77338
Reference Data: 1. TAS 125-03:ASTM E 1592-01
Force Engineering&Testing,Inc.(FBC Organization#TST-5328)
Report No.84-0320T-06A-D,Dated 04/09/2007
2. TAS 201-94
Farabaugh Engineering&Testing,Inc.(FBC Organization#TST-1654)
Report No.T202-07
3. FM 4471 Appendix G
Farabaugh Engineering&Testing,Inc.(FBC Organization#TST-1654)
Report No.T203-07
4. TAS 110-00:Valspar Fluropon coated metal panel testing
A)ASTM G 26 by PRI Asphalt Technologies dated 01/19/2004
B)ASTM B 117 by PRI Asphalt Technologies dated 01/19/2004
5. FM 4471-10,Section 4.4 Foot Traffic Resistance Test
Force Engineering&Testing,Inc.(FBC Organization#TST-5328)
Report No.117-0378T-11A,Dated 02/15/2012
6. Certificate of Independence
By Terrence E.Wolfe,P.E.(No.44923)@ Force Engineering&Testing,Inc.
(FBC Organization#ANE ID:1920)
Quality Assurance Entity: The manufacturer has established compliance of roof panel products in
accordance with the Florida Building Code and Rule 9N-3.005(3)for
manufacturing under a quality assurance program audited by an approved
quality assurance entity.
Minimum Slope Range: 1/2:12. Minimum Slope shall comply with Florida Building Code 2010,including
Section 1515.2 and in accordance with Manufacturers recommendations. For
slopes less than 3:12,lap sealant must be used in the panel side laps.
Installation: Install per manufacturer's recommended details and RAS 133.
Underlayment: Per Manufacturer's installation guidelines per Florida Building Code 2010 Section
1518.2,1518.3,1518.4.
Fire Barrier: Any approved fire barrier having a current NOA. Refer to a current fire directory
listing for fire ratings of this roofing system assembly as well as the location of
the fire barrier within the assembly. Fire classification is not part of this
acceptance.
k.q
O
STATE OF 7
40
41
,41
VAIL
aasna ,e.-I�
FL#11650.2 R1
February 17, 2012
Force En;inecrinc,&&"estirag Inc.
19530 Ramble good Ddvc
Humble,TX 77338
Shear Diaphragm: Shear diaphragm values are outside the scope of this report.
Design Procedure: Based on the dimensions of the structure,appropriate wind loads are
determined using Chapter 16 of the Florida Building Code 2010 for roof cladding
wind loads.These component wind loads for roof cladding are compared to the
allowable pressure listed above.The design professional shall select the
appropriate erection details to reference in his drawings for proper fastener
attachment to his structure and analyze the panel fasteners for pullout and
pullover.Support framing must be in compliance with Florida Building Code 2010
Chapter 22 for steel,Chapter 23 for wood and Chapter 16 for structural loading.
C E N S F �.t•,�i
No.440
a STATE OF :or
ssu.orroaa► �i FS . v1��
FL#11650.2 R1 February 17, 2012