HomeMy WebLinkAboutDrawing RECEIVE-D DEC 0 3 2015
FILE COPY
1
Lr
72" X 80"
REPLACE DOORS IN 1 OPENING ONLY.
LESS THAN 25%OF TOTAL GLAZED AREA TO BE REPLACED UNDER THIS PERMIT.SHUTTERS
NOT REQUIRED PER FBC,5TH EDITION(2014), EXISTING BUILDINGS,706.4,EXCEPTION#2.
OPENING PRODUCT DESIGN
OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS
NO. WIDTH. HGT. FTG. ZONE POS. NEG. (N.O.A.#) POS. NEG.
1 72 80 40.00 1 4 34.4 1 -37.6 FL15220.4 50.0 1 -50.0 <25%GLAZED AREA REPLACEMENT
U-FACTOR-.32 SHGC-.25
REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS.
NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS.
ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 1/4" TAPCON SCREWS INTO CONCRETE
WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS.
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES
MEAN ROOF HEIGHT= 11 FT 0 IN
MILLER RESIDENCE
414 COCONUT AVENUE, E. DOOR REPLACEMENT PLAN
PORT ST LUCIE, FLORIDA