Loading...
HomeMy WebLinkAboutWind Load Calculation Company: The Home Depot At Home Services Job Description: 10 windows and 2 doors size Prepared By: Amber . Client Name: Hix Project Number: 8762946 Version 10 0 Conforms with ASCE 7 10 e;201- S ua"tore I a aI,LLC,-" ■�.'�� �■ �,.. ,y{,p Via.- w. ......;. »,..a ,, n..,,v ,.._..,,.._ ,� v. .�n.�w,•x ... ." z„ s,-s., -' DESIGN PRESSURES FOR WALL COMPONENTS&CLADDING Design Data Building Data Wind Velocity(mph) 160 Mean Roof Height 12 Risk Category 2 Building Width(ft) 27 Exposure Category D Building Length(ft) 56 Directionality Factor 0.85 Roof Slope (x:12) 3 Internal Pressure Coefficient+/ 0.18 Design pressures listed below are: Allowable Stress OPENING OPENING LOCATION OPENING OPENING DIMENSIONS MAXIMUM POSITIVE MAXIMUM NEGATIVE MARK DESCRIPTION ZONE ELEVATION WIDTH(INCHES) HEIGHT(INCHES) PERSSURE(PSF) PRESSURE(PSF) 1 9700-PD BI 5 0 60 80 37.5 -48.0 2 9700-SH BI 5 5 36 48 40.2- -53.4 3 9700-SH BI 5 5 36 48 40.2 -53.4 4 9700-SH BI 5 5 36 48 40.2 -53.4 5 9700-SH BI 5 5 36 48 40.2 -53.4 6 9700-SH BI 5 5 34 25 '40.6 -54.4 7 9700-PD BI 5 0 72 80 37.0 -47.1 8 9700-SH BI 5 5 34 25 40.6 -54.4 9 9700-SH BI 5 5 36 48 40.2 -53.4 10 9700-SH BI 5 5 36 48 40.2 -53.4. 11 9700-SH BI 5 5 36 48 40.2 -53.4 12 9700-SH BI 5 5 36 48 40.2 -53.4 Width of End Zone(a)in feet= 3 i 5 h 5� 0 O O a 5 5 Y ' s STRUCTURES INTERNATIONAL,LLC 11/12/2015 5:01 PM Ronald and Carla Hix,48762946 505 Ponderosa Dr. 31 D Fort Pierce, FI_34982 Replacing.2 doorsand 10 windows.size for size with impact_ 0 Q .. .. __ 1 Sliding Glass Door 60"x 80" Kitchen FL 8208.2 + j37 5,;— 48.0 2 Single Hung Window 36°x 48" Bedroom FL 1435.4 40 2, — 53.4 3 Single Hung Window 36"x 48" Bedroom FL 1435.4 + :140.2,1— 53.4 4 Single Hung Window 36"x 48" Bedroom FL 1435.4 + 140.2, — 53.4 5 Single Hung Window 36"x 48" Bedroom FL 1435.4 + 40.2, -!53.4 6 Single Hung Window 34"x 25" Bathroom FL 1435.4 + 40.6,' 54.4 7 Sliding Glass Door 72"x 80" Dining Room FL 8208.2 + !37 0, — 47.1 10 8 Single Hung Window 34"x 25" Bathroom FL 1435.4 -1- ;40.6,'— 54.4 9 Single Hung Window 36"x 48" Bedroom FL 1435.4 -1- i40.2,1-153.4 10 Single Hung Window 36"x 48" Bedroom FL 1435.4 -1- ;40.2,_— 53.4 12 11 11 Single Hung Window 36"x 48" Bedroom FL 1435.4 $ 140.2, — 53.4 12 Single Hung Window 36"x 48" Bedroom FL 1435.4 + 140.2, — 53.4 ,Line items 2 and 3 are being mulled together. Line items 4 and 5 are being mulled together. Line items 9 and 10 are being mulled together. 'Line items 11 and 12 are being mulled together. All are using NOA 14-1105.01.