HomeMy WebLinkAboutEngineering COOK & MENARD ARCHITECTURE INC.
806 Delaware Avenue, Fort Pierce, Florida 34950
PHONE(772)460-7751 FAX(772)460-4244 1-S
EMAIL cookmenard@yahoo.com
RECEIVED DEC 0 71015
December 3, 2015
Saint Lucie County Building Department
Attn: Roof Permit Plan Review
2300 Virginia Avenue
Ft. Pierce, FL 34982
Re: Roofing specification prepared for the St. Lucie County Building Dept.for the structure located at,
10420 Glades Cut off Rd., Saint Lucie County, Florida
Manufacturer: Gulf Coast Supply& Manufacturing
Profiles: 24 GA GulfPBR Roof Panel FL# 11650.2 ,
Code: FBC 2014
Wind Speed: 160 MPH; Ultimate Design Wind Speeds AILE
Exposure: B
Mean Roof Height: 30' Maximum
Pitch: 1/12'
Required Design Pressure: Zone1:-38.2 Zone 2: -53.9 Zone3: -101.4
Maximum Uplift Pressure: Fastener spacing:-60psf @ 5'-0"o.c. zone 1 & 2, -150 psf @ 2'-0" o.c. zone 3
Panel Fastener: #12-14 x 1-1/4" HWH SD with sealing washing or approved equal at
12"-12"-12"fastener pattern. Panel side laps fastened together w/1/4" -140/8"
HWH SD w/sealer washer at Maximum 18"O.C.
Corrosion Resistance: Per Florida Building Code 2014, section 1506.6, 1507.4.4
Substrate Description: Minimum 16 Ga. Steel Framing. Must be designed in accordance w/ Florida
Building Code 2014.
The above approved,as per Florida Building Code Compliance acceptances, 2014 Florida Building Code, and the
Manufacturer's recommendations.
ST.LUCIE C®UP1V
pLAH REVIEW
Respectfully Submitted,
/
BLDG:
DATE:
ELEC:
DATE:
Peter B. Cook PLUMB:
Cook& Menard Architecture, Inc. DATE,
MECH:
DATE:
Florida Registration No. AA0003494, NCARB Certification No. 31789