Loading...
HomeMy WebLinkAboutEngineering COOK & MENARD ARCHITECTURE INC. 806 Delaware Avenue, Fort Pierce, Florida 34950 PHONE(772)460-7751 FAX(772)460-4244 1-S EMAIL cookmenard@yahoo.com RECEIVED DEC 0 71015 December 3, 2015 Saint Lucie County Building Department Attn: Roof Permit Plan Review 2300 Virginia Avenue Ft. Pierce, FL 34982 Re: Roofing specification prepared for the St. Lucie County Building Dept.for the structure located at, 10420 Glades Cut off Rd., Saint Lucie County, Florida Manufacturer: Gulf Coast Supply& Manufacturing Profiles: 24 GA GulfPBR Roof Panel FL# 11650.2 , Code: FBC 2014 Wind Speed: 160 MPH; Ultimate Design Wind Speeds AILE Exposure: B Mean Roof Height: 30' Maximum Pitch: 1/12' Required Design Pressure: Zone1:-38.2 Zone 2: -53.9 Zone3: -101.4 Maximum Uplift Pressure: Fastener spacing:-60psf @ 5'-0"o.c. zone 1 & 2, -150 psf @ 2'-0" o.c. zone 3 Panel Fastener: #12-14 x 1-1/4" HWH SD with sealing washing or approved equal at 12"-12"-12"fastener pattern. Panel side laps fastened together w/1/4" -140/8" HWH SD w/sealer washer at Maximum 18"O.C. Corrosion Resistance: Per Florida Building Code 2014, section 1506.6, 1507.4.4 Substrate Description: Minimum 16 Ga. Steel Framing. Must be designed in accordance w/ Florida Building Code 2014. The above approved,as per Florida Building Code Compliance acceptances, 2014 Florida Building Code, and the Manufacturer's recommendations. ST.LUCIE C®UP1V pLAH REVIEW Respectfully Submitted, / BLDG: DATE: ELEC: DATE: Peter B. Cook PLUMB: Cook& Menard Architecture, Inc. DATE, MECH: DATE: Florida Registration No. AA0003494, NCARB Certification No. 31789 .}, ��� s �� ih, b�''r:j 1::ff; i . _ f i � - ��- � ��- f