HomeMy WebLinkAboutProduct Approval (2) Florida Building Code Online Page 1 of 2
Susin
e a Reg on
AM
Florida Deparlment� SCIS Home i Login User Registration Hot Topics i Submit Surcharge I Stats&Facts i Publications i FBC Staff I SCIS Site Map 1 Links I Search '.
BusinesO,
iaProdctProfessi n2aUSER:Publics U�seroval
Regulation
Product Approval Menu>Product or ADDlication Search>Application List>Application Detail
FL# FL389-R8
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived L
Product Manufacturer American Shutter Systems Association,Inc.
Address/Phone/Email 4268 Westroads Drive
West Palm Beach, FL 33407
(561)209-8263
bfeeley@easternmetal.com
Authorized Signature Bill Feeley
Irodriguez@easternmetal.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Shutters
Subcategory Accordion
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
WA Evaluation Report-Hardcopy Received
Florida;Engineer or Architect Name who developed Walter A..Tillit,Jr. P.E.
the Evaluation Report
Florida License PE-44167
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2017
Validated By John W. Knezevich,PE
9 Validation Checklist-Hardcopy Received
Certificate of Independence FL389 R8 COI HV ACCORDION CI NONHVHZ.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM E-1886 2005
ASTM E-1996 2005
ASTM E-330 2002
TAS 201, 202,203 1994
Equivalence of Product Standards
Certified By
Sections from the Code
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvYYHH2vJvx... 10/7/2015
orida Building Code Online Page 2 of 2
Product Approval Method Method 1 Option D
i
Date Submitted 04/29/2015
Date Validated 04/29/2015
Date Pending FBC Approval 05/07/2015
Date Approved 06/22/2015
Summary of Products
FL# Model,Number or Name Description
389.1 Bertha HV Accordion Shutter- Extruded aluminum interlocking blades retained by tracks
Blade 3-(Non-HVHZ)-Drwg 15- (top and bottom)for storm protection
086
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL389 R8 II A.S.S.A. INC. DRWG.15-086.pdf
Approved for use outside HVHZ:Yes Verified By: American Test Lab of South Florida Inc.
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:Large Missile Level"D".Max span is 12'-7"for 3,,5 psf FL389 R8 AE A.S.S.A.INC. P.E.R. DRWG.15-086.pdf
positive ASD load and 13'-0"for 35 psf negative ASD load Created by Independent Third Party: Yes
the HV3 blade w/o window blade,5'-2"for 110 psf ASD load
for HV3 blade w/o window blade and 8'-11"for 62 psf,9'-6"
for 55 psf HV3 blade w/window blade working in
unison.Max.span for HV3 blade w/o window blade for
installations into Metal Stud walls is 79"for max.ASD
pressure rating of+72,-72 and 84"for+64,-64 psf.See
sheet 5 for other spans and ASD pressures.
389.2 Bertha HV Accordion Shutter-Blade Extruded aluminum interlocking blades retained by tracks
1 Only-(Non-HVHZ)-Drwg 15-085 (top and bottom)for storm protection
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL389 R8 II A.S.S.A. INC. DRWG.15-085.pdf
Approved for use outside HVHZ:Yes Verified By: American Test Lab of South Florida Inc.
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:Large missile level"D".Max.Span is 16'-0"for 30 FL389 R8 AE A.S.S.A. INC. P.E.R. DRWG. 15-085 HV.pdf
p.s.f negative ASD load depending on centermates and Created by Independent Third Party: Yes
locking rod configuration for the HV1 blade,8'-0"for+64,
-72 p.s.f. load for HV blade for Keystone mountings 7'-0"for
+75,-75 p.s.f.for metals stud mountings and 8'-0"for 110
p.s.f.for HV1 and HV1A working in unison. See sheets 7, 11
and 20 respectively of installation drawings for other spans
and pressures.
389.3 Bertha HV Accordion Shutter- Extruded aluminum interlocking blades retained by tracks
COMBO-(Non-HVHZ)-Drwg 15- (top and bottom)for storm protection
084
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL389 R8 II A.S.S.A. INC. DRWG.15-084.pdf
Approved for use outside HVHZ:Yes Verified By: American Test Lab of South Florida Inc.
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:Large missile. Max. 16'-0"span at 30 p.s.f ASD load FL389 R8 AE A.S.S.A. INC P.E.R. DRWG.15-084.pdf
for Blade 1 and 18'-0"for Blade 2.See schedules on sheet Created by Independent Third Party:Yes
12,25 and 28 respectively
Back Next
Contact Us::1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts:
® ® ttihe_k -ti.T.
securitv.,mi c,
https://www.floridabuilding.org/pr/P _app_dtl.aspx?param=wGEVXQwtDgvYYHH2vJvx... 10/7/2015