HomeMy WebLinkAboutProduct Approval Florida Building Code Online https://www.floridabuilding.org/pr/pi_app dti-aspx?param=wGEVX...
33��Y"fit
d BCLS Home Log In User Regktmtbn Hot TOPICS Subntt Surcharge Stats&Facts Publications FBC Staff BCLS Ste Map Unks Search
Busines ��'i Product Approval
ProfesZihai USER:Public User
RECEIVED
�I Product Aooroval Menu>Product or Appkatbn Search>A�Ikati�n_Ust>Application Detal
FL# FL6785-R6 DEC 14 2015
Application Type Revision
Code Version 2014 PERMITTING
Application Status { Approved St. Lucie County, FL
Comments
Archived
Product Manufacturer Carlisle Coatings&Waterproofing
Address/Phone/Email 900 Hensley Lane
Wylie,TX 75098
(717) 245-7000 Ext 7456
wert@syntec.carlisle.com
Authorized Signature Chad Wert
wert@syntec.carlisle.com
Technical Representative
Address/Phone/Email FILE COPY
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 08/01/2016
Validated By John W.Knezevich,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL6785_R6 COI 2015 01 COI Nieminen W
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2009
Equivalence of Product Standards
Certified By
Sections from the Code
1 of 2 12/10/2015 1:53 PM
Florida Building Code Online https://www.floridabuilding-org/pr/pr app_dtl.aspx?param=wGEVX...
Product Approval Method Method i Option D
Date Submitted 02/27/2015
Date Validated 03/01/2015
Date Pending FBC Approval 03/05/2015
Date Approved 04/15/2015
Summary of Products
FL# Model,Number or Name Description
6785.1 CCW Roof Underlayments Self Adhesive Roofing Underlayments
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL6785 R6 II 2015 02 FINAL ER CARLISLE UNDERLAYMENTS FL6785-
Approved for use outside HVHZ:Yes R6 Qdf
Impact Resistant:N/A Verified By: Robert Nieminen 59166
Design Pressure: N/A Created by Independent Third Party:Yes
Other:Refer to ER Section 5 for Limits of Evaluation Reports
Use. FL6785 R6 AE 2015 02 FINAL ER CARLISLE UNDERLAYMENTS FL6785
R6.pdf
Created by Independent Third Party:Yes
d I
Contact Us::1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida Is an AA/EEO employer.Cooyrioht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your a-mal address released In response to a pubic-records request,do not send electronic
mail to this entty.Instead,contact the office by phone or by traditional mal.R you have any questions,please contact 850.487.1395.-Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department wth an email address If they have
one.The emacs provided may be used for official communication wth the licensee.However email addresses are pubic record.9 you do not wish to supply a
personal address,please provide the Department with an emal address which can be made avalable to the public.To determine r you are a licensee under Chapter
45S,F.S.,please click here.
Product Approval Accepts:
W] W I eCtec
K curite,,,:,:r,
2 of 2 12/10/2015 1:53 PM
EXTERIOR RESEARCH&DESIGN,LLC.
Certificate of Authorization#9503
TRINI 1 1 353 CHRISTIAN STREET,UNIT#13
ERD OXFORD,CT 06478
PHONE:(203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
Carlisle Coatings&Waterproofing Evaluation Report C39180.12.11-R3
900 Hensley Lane FL6785-116
Wylie,TX 75098 Date of Issuance:12/09/2011
Revision 3:02/04/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have evaluated for compliance with the 5th Edition (2014) Florida Building Code sections
noted herein.
DESCRIPTION: CCW Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words 'Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 3.
Prepared by:
The facsimile seal appearing was authorized
'+.,F �` �,'y�.�`
by=Nieminen,P.E.on 02/04/2015
Robert J.M.Nieminen,P.E. �+oac�s�' This does not serve as an electronically signed document.Signed,
�,JAan nrY g gn
Florida Registration No.59166 Florida DCA ANf1983 sealed hardcoples have been transmitted to the Product Approval
Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: CCW Roof Underlayments, as produced by Carlisle Coatings & Waterproofing, have demonstrated
compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.4,1507.2.8(3),1507.2.9.2, Physical Properties ASTM D1970 2009
1507.4.5.1,1507.4.5.2(3),
1507.5.3,1507.5.3.2(3),1507.7.3,
1507.7.3.2(3)
3. REFERENCES:
Entity Examination Reference Date
ERD(TST6049) Physical Properties C41280.10.12 10/05/2012
MTI(TST2508) Physical Properties PX02MOA 01/17/2011
MTI(TST2508) Physical Properties PX16MOA 01/18/2011
MTI(TST2508) Physical Properties PX13MOB 01/18/2011
ICC-ES(EVL2396) 2012&2009 IBC/IRC Compliance ESR-1556 04/01/2014
ICC-ES(EVL2396) 2012&2009 IBC/IRC Compliance ESR-2206 04/01/2014
UL,LLC.(QUA9625) Quality Control TGDY.R38678 Listing 10/18/2010
UL,LLC.(QUA9625) Quality Control Inspection Report,R18678 08/01/2014
4. PRODUCT DESCRIPTION:
4.1 CCW WIP 100 is a self-adhering,fiberglass reinforced,granule surfaced,rubberized asphalt roof underlayment.
4.2 CCW WIP 250 is a self-adhering,fiberglass reinforced,film surfaced,rubberized asphalt roof underlayment.
4.3 CCW WIP 300HT is a self-adhering,coated-polyolefin-composite film surfaced,rubberized asphalt roof underlayment.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this report;refer to current Approved Roofing Materials Directory for fire ratings of this
product.
5.4 CCW Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed,a request may be made to the AH1 for approval based on this evaluation
combined with supporting data for the prepared roof covering.
5.5 Allowable roof covers applied atop the underlayments are follows:
TABLE 1: ROOF COVER Op noNS
Asphalt Wood Shakes Slate&
Underlayment Shingles Nail-On Tile Foam-On Tile Metal &Shingles Synthetic
Slate/Shake
CCW WIP 100 Yes No No No No No
CCW WIP 250 Yes No No Yes No No
CCW WIP 300HT Yes No No Yes No Yes
Exterior Research and Design,LLC. Evaluation Report[39180.12.31-R3
Cartifio3te of Authorietion 09503 FL678S-R6
Revision 3:02/04/2015
Page 2 of 3
TRINITY ERD
5.6 Allowable substrates are noted below:
5.6.1 Direct-Bond to Deck:
Self-adhering membranes applied to:
❑ New untreated plywood;
❑ Primed new untreated plywood;
❑ Existing plywood;
❑ Primed existing plywood;
Note:While not required,CCW-701 or CAV-GRIP primer may be used when deemed appropriate or when temperatures
are below 407.
5.6.2 Bond to Mechanically Attached Base Laver:
Self-adhering membranes applied to:
❑ ASTM D226,Type I or II felt;
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements.
5.7 Exposure Limitations:
5.7.1 CCW WIP 100,CCW WIP 250 and CCW WIP 300HT shall not be left exposed for longer than 30-days after installation.
6. INSTALLATION:
6.1 CCW Roof Underlayments shall be installed in accordance with Carlisle Coatings & Waterproofing published
installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application. Prime the substrate(if applicable)with CCW-702 or CAV-GRIP Primer.
6.3 CCW WIP 100.CCW WIP 250 and CCW WIP 300HT:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections 1507 for the
type of prepared roof covering to be installed.
6.3.2 While not required,CCW-702 or CAV-GRIP primer may be used when deemed appropriate. Priming is required when
temperatures are below 40°F.
6.3.3 Cut WIP roofing underlayment into 10 to 15 ft lengths. Remove 2 to 3 ft of release film and align the edge of the
membrane,sticky-side down,so it overhangs the drip edge by 3i8-inch. Continue to remove release film and press as
you move across the roof. Use a hand roller and/or hand pressure to press into place.
6.3.4 Horizontal seams should be minimum 3.5-inches, configured to shed water. Vertical seams should be 6-inches and
staggered not less than 2-ft from vertical seams in the course below.
6.3.5 Consult Carlisle Coatings&Waterproofing for steep slope&back nailing requirements.
6.3.6 For Valleys and Ridges: Cut WIP roofing underlayment into manageable lengths. Align over the center of the valley,
hip or ridge. Remove release film. Press the middle of the membrane first before working toward the edges. For
open valleys,cover roofing underlayment with metal valley liners.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS:
Contact the manufacturer or the named QA entity for plants covered under Rule 61G20-3 CIA requirements.
9. QUALITY ASSURANCE ENTITY:
UL,LLC—QUA9625;(847)664-3281
-END OF EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation Report 039180.12.11-R3
CertificateofA dhorimtion#9503 FL678S-R6
Revision 3:02/04/2015
Page 3 of 3
Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_ tl.aspx?param=wGEVX...
. sem
"i: BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats d Facts Publcatbns FBC Stafr BCLS Site Map Links Search
I
Businessy"
Professibnal � Public UserApp '
Produd-A roval Menu>Product or Application Search>AppIcartbrLL.Wt>Appiotion DOUR
FL# FL1956-R12
Application Type Editorial Change
Code Version 2014
Application Status Approved
*Approved by DBPR.Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer TAMKO Building Products, Inc.
Address/Phone/Email PO Box 1404
Joplin,MO 64802
(417)624-6644 Ext 2305
kerri_eden@tamko.com
Authorized Signature Kerr!Eden
kerri—eden@tamko.com
Technical Representative Kerri Eden
Address/Phone/Email PO Box 1404
Joplin,MO 64802
(417)624-6644 Ext 2305
kerri_eden@tamko.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Certification Mark or Listing
Certification Agency UL LLC
Validated By Robert J. M. Nieminen, PE
Validation Checklist-Hardcopy Received
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 2009
ASTM D3462 2009
ASTM D7158 2008
Equivalence of Product Standards
Certified By
1 of 4 12/10/2015 1:31 PM
Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_ ti.aspx?param=vGEVX...
Product Approval Method Method 1 Option A
Date Submitted 09/17/2015
Date Validated 10/06/2015
Date Pending FBC Approval
Date Approved 10/09/2015
Summary of Products
FL# j Model, Description
Number or
Name
1956.1 Elite Glass-Seal A three tab asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in FL1956 R12 C CAC FL1956 Rll C CAC Tamko Sery Conf FL 1956 2015,p f
HVHZ: No FL1956 R12 C CAC UL certification 10-11-1�df
Approved for use outside I Quality Assurance Contract Expiration Date
HVHZ:Yes 109/17/2018
Impact Resistant:N/A Installation Instructions
Design Pressure:N/AI FL1956 R12 II Glass Seal Elite Glass Seal st
Seal-App in .pdf
! Other:Asphalt shingles Verified By: Robert Nieminen 59166
shall be used only on roof Created by Independent Third Party: No
slopes of 2:12 or greater. Evaluation Reports
Nails must be used as the Created by Independent Third Party:
method of attachment.
1956.2 Glass-Seal A three tab asphalt shingle. _
Limits of Use Certification Agency Certificate
Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015.p-df
HVHZ:No FL1956 R1_2 C CAC UL certification 10_11- 2". df
1 Approved for use outside Quality Assurance Contract Expiration Date
HVHZ:Yes 09/17/2018
Impact Resistant: N/A Installation Instructions
Design Pressure:N/A FL1956 R12 II Glass Seal Elite Glass Seal app inst,p_df
Other:Asphalt shingles Verified By: Robert Nleminen PE 59166
shall be used only on roof Created by Independent Third Party: No
slopes of 2:12 or greater. j Evaluation Reports
Nails must be used as the Created by Independent Third Party:
method of attachment.
------_ — — ---- - -----------.... --- ----------
1956.3
-------1956.3 Heritage TA dimensional asphalt shingle.
Limits of Use Certification Agency Certificate
Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015.pdf
HVHZ:No FL1956 R12 C CAC UL certification 10-11-12,pdf
Approved for use outside Quality Assurance Contract Expiration Date
'HVHZ:Yes 09/17/2018
Impact Resistant:N/A Installation Instructions
Design Pressure:N/A FL1956 R12 II Heritage D F J_P a p jnst.pdf
Other:Asphalt shingles FL1956 R12 II Heritage F appinst.Qdf
shall be used only on roof FL1956 R12 II Heritage-T app inst,pdf
slopes of 2:12 or greater. Verified By: Robert 1.M.Nieminen FL 59166
Nails must be used as the Created by Independent Third Party: No
method of attachment. Evaluation Reports
Created by Independent Third Party:
1956.4 'Heritage 30 A dimensional asphalt shingle
Limits of Use Certlf[cation Agency Certificate
Approved for use In FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015 df
HVHZ:No FL1956 R12 C CAC UL certification 10-11-12 gdf
Approved for use outside Quality Assurance Contract Expiration Date
HVHZ:Yes 09/17/2018
Impact Resistant:N/A Installation Instructions
Design Pressure: N/A FL1_956 R12 II heritage 30_ap-p_1nst april_-l0.pdf
Other:Asphalt shingles FL1956 R12 II heritage 30_app inst f a ril l0.pdf
shall be used only on roof Verified By: Robert Nieminen PE 59166
slopes of 2:12 or greater. Created by Independent Third Party: No
Nails must be used as the Evaluation Reports
j method of attachment. 1 Created by Independent Third Party:
2 of 4 12/10/2015 1:31 PM
Florida Building Code Online https://www.floridabuilding.org/pr/pr_app dti.aspx?param=wGEVX...
1956.5 l Heritage 50 A dimensional asphalt shingle i
Limits of Use Certification Agency Certificate
Approved for use in j FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956_2015.pdf
HVHZ:No FL1956 R12 C CAC UL certification 10-11_11pdf
Approved for use outside Quality Assurance Contract Expiration Date
HVHZ:Yes 09/17/2018
Impact Resistant: N/A !Installation Instructions
Design Pressure:N/A FL1956 R12 II heritage 50 �nst a rii l0.pdf j
` Other:Asphalt shingles FL1956 R12 II heritage 50 app inst f april 1df
I shall be used only on roof Verified By: Robert Nieminen PE 59166
IIII slopes of 2:12 or greater. Created by Independent Third Party:No
Nails must be used as the Evaluation Reports
method of attachment. Created by Independent Third Party:
1956.6 I Heritage .A dimensional asphalt shingle.
Premium
Limits of Use Certification Agency Certificate
Approved for use In F11956 R12 C CAC FL_1956 Ril_C CAC Tamko Sery Conf FL1956_2015,pdf
HVHZ:No FL1956 R12 C CAC UL certification 10-11-12.pdf
j Approved for use outside Quality Assurance Contract Expiration Date
HVHZ:Yes 09/17/2018
Impact Resistant: N/A Installation Instructions
Design Pressure:N/A FL1956 R12 II Heritage Premium D P app inst,pdf
j Other:Asphalt shingles FL1956 R12_II Heritage Premium F app inst•pdf
shall be used only on roof FL1956 R12 II Heritage Premium Tapp inst.pdf
slopes of 2:12 or greater. Verified By: Robert Nieminen 59166
Nails must be used as the Created by Independent Third Party: No
method of attachment. Evaluation Reports
Created by Independent Third Party:
Heritage A heavy weight dimensional asphalt shingle.
1;56.7
Limits of UlseVintage i _-_-._—_-_--------_—__-__-----_.__--�
--- r-- ---------------------
Certification Agency Certificate
Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery_Conf FL 1956 2015.pdf
HVHZ:No FL1956 RSC CAC UL shingle matrix. df
Approved for use outside Quality Assurance Contract Expiration Date
HVHZ:Yes 09/17/2018
Impact Resistant: N/A Installation Instructions
Design Pressure: N/A FL1956 R12 II Heritage Vintage app inst.pdf
Other:Asphalt shingles j Verified By: Robert J.M.Nieminen PE 59166
i shall be used only on roof Created by Independent Third Party: No
slopes of 2:12 or greater. Evaluation Reports
Nails must be used as the Created by Independent Third Party: I
method of attachment. j
1956.8 Heritage I Hip and ridge shingles
Vintage 12 X 12
Hipand Ridge -=---- ---------------- ---------------------- --...--------
Limits of Use Certification Agency Certificate
Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL1956 2015.pdf
HVHZ:No FL1956 R12 C_CAC UL shin-gIe matrix. df
Approved for use outside I Quality Assurance Contract Expiration Date j
HVHZ:Yes 09/17/2018
Impact Resistant:N/A Installation Instructions
Design Pressure: N/A FL1956 R12 II TAMKOHerita e@ 12 x 12 H1and Ridge Application Instructions,pdf�
Other:Asphalt shingles Verified By: Robert J.M.Nieminen PE 59166
shall be used only on roof Created by Independent Third Party: No
slopes of 2:12 or greater. Evaluation Reports j
Nails must be used as the Created by Independent Third Party:
method of attachment.
1Heritage �A dimensionalWood ate _
956.9 asphalt shingle.
�
9 -- —
Limits of Use Certification Agency Certificate- -- --- --------�------�
Approved for use in FL1956 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015.pdf
HVHZ:No !, FL19.5_6 R12 C CAC UL certification 10=._1_1-.12,pdf
1 Approved for use outside Quality Assurance Contract Expiration Date
HVHZ:Yes 09/17/2018
Impact Resistant: N/A Installation Instructions
Design Pressure:N/A FL1956 R12 II Heritage Wood ate D a iinst pdf
Other:Asphalt shingles FL1956 R12 II Heritage Woodgate F app instgdf
shall be used only on roof Verified By: Robert Nieminen 59166
slopes of 2:12 or greater. Created by Independent Third Party: No
i
3 of 4 12/10/2015 1:31 PM
Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_ ti.aspx?parwn=wGEVX...
Nails must be used as the Evaluation Reports j
i method of attachment. Created by Independent Third Party:
1956.10 Heritage XL 'A dimensional asphalt shingle.
Limits of Use Certification Agency Certificate i
Approved for use in FL195-6 R12 C CAC FL1956 R11 C CAC Tamko Sery Conf FL 1956 2015.pdf
HVHZ: No j FL1956 R12_C CAC UL certification 10-11-12.pdf
Approved for use outside ! Quality Assurance Contract Expiration Date
HVHZ:Yes 09/17/2018
Impact Resistant:N/A I Installation Instructions
Design Pressure:N/A FL1956 R12 II hent a a xi app inst d apn l0.pdf
Other:Asphalt shingles _FL1956 R12 II heritage xl app Inst f april 10.g!f
shall be used only on roof Verified By: Robert Nieminen PE 59166
I slopes of 2:12 or greater. Created by Independent Third Party: No
Nails must be used as the Evaluation Reports
method of attachment. _ Created by Independent Third Party:
1956.11 Hip and Ridge Hip and ridge shingles
Shingles
Limits of Use Certification Agency Certificate
Approved for use in FL1956 R12C CAC—FL-1956 R11 C CAC Tamko Serv_Conf FL_i9�6 2.0__35.�df
HVHZ:No FL1956 R12 C CAC_UL certification 10-11-12.pdf
Approved for use outside Quality Assurance Contract Expiration Date
HVHZ:Yes 09/17/2018
Impact Resistant:N/A Installation Instructions
Design Pressure: N/A FL1956 R12 II 12 25x12 Hip and Ridgepddf
Other:Hip and Ridge 51956 R12 II 12 x 12 Hig Rid�c e Aoolication Instructions.odf
shingles shall be used only RA956 R12_II 12__1-4x12 HipRidye Sealant Dab Illustration df
on roof slopes of 2:12 or FL1956 R12 II 12x12 HipRidoe Sealant_Dab_Illustrationspdf
greater. Nails must be used Verified By: Robert Nieminen 59166
as the method of Created by Independent Third Party: No
attachment. Evaluation Reports
Created by Independent Third Party:
lwa i L^"x'_I
Contact Us::1940 North Monroe Street Talahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Coovrioht 2007-2013 State of Florida.::Privacy Statement::Accessibility statement::Refund Statement
Under Florida law,emal addresses are pubic records.If you do not want your a-mal address released In response to a public-records request,do rot send electronic
mal to this entity.Instead,contact the office by phone or by traditional mal.R you have any questions,please contact 850.487.1395.*Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have
one.The emacs provided may be used for official communication with the licensee.However email addresses are public record.ff you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the pubic.To determine If you are a licensee under Chapter
455,F.S.,please click here.
Product Approval Accepts:
Wri
4 of 4 12/10/2015 1:31 PM
® Application Instructions for FORMERLY HERITAGE®30
TAMKO HER1TAGCO
BUILDING PBODOc" LAMINATED ASPHALT SHINGLES
Dallas, TX • Frederick, MD • Joplin, MO • Phillipsburg, KS
THESE ARE THE MANUFACTURER'S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED.
TAMKO BUILDING PRODUCTS,INC.ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING DEFECTS RESULTING FROM
FAILURE TO FOLLOW THE MANUFACTURER'S INSTRUCTIONS.FAILURE TO FOLLOW THESE INSTRUCTIONS WILL ADVERSELY
AFFECT COVERAGE UNDER THE LIMITED WARRANTY.SEE THE LIMITED WARRANTY FOR DETAILS.
THIS PRODUCT IS COVERED BY A LIMITED WARRANTY,THE TERMS OF WHICH ARE PRINTED ON THE WRAPPER.
IN COLD WEATHER(BELOW 40°F),CARE MUST BE TAKEN TO AVOID DAMAGE TO THE EDGES AND CORNERS OF THE SHINGLES.
IMPORTANT•.It is not necessary to remove the plastic strip from the back of the shingles.
1.1106E OAR S.FA31"ns
These shingles are for application to roof decks consisting of plywood WIND CAUTION. Extreme wind velocities can damage these
or sheathing boards capable of receiving and retaining fasteners,and shingles after application when proper sealing of the shingles does
to inclines of not less than 2 in,per foot.For roofs having pitches 2 in. not occur.This can especially be a problem if the shingles are applied
per foot to less than 4 in.per foot,refer to special instructions titled in cooler months or in areas on the roof that do not receive direct
"Low Slope Application".For roofs having pitches greater than 21 in. sunlight.These conditions may impede the sealing of the adhesive
per foot,refer to special instructions titled"Mansard Roof or Steep strips on the shingles.The inability to seal down may be compounded
Slope Roof".Shingles must be applied properly.TAMKO assumes no by prolonged cold weather conditions and/or blowing dust.In these
responsibility for leaks or defects resulting from improper application, situations,hand sealing of the shingles is required.To insure quicker
or failure to properly prepare the surface to be roofed over. sealing, apply 4 quarter-sized dabs of TAM-PRO®SBS Flashing
Cement,TAMKO or TAM-PRO®Plastic Roof Cement,or TAMKO
NEW ROOF DECK CONSTRUCTION:Roof deck must be smooth, Tam-Seal Adhesive,meeting ASTM D 4586,Type 1,on the back of
dry and free from warped surfaces. It is recommended that metal the shingle 1 in.(25mm)and 13 in.(330mm)in from each side and
drip edges be installed at eaves and rakes. 1 in.(25mm)up from the bottom of the shingle.Press shingle firmly
PLYWOOD: All I into the adhesive.For maximum wind resistance along rakes,install
plywood shall be exterior grade as defined by any TAMKO starter shingle including sealant or cement shingles to
APA - The Engineered Wood Association. Plywood shall be a the underiayment and each other in a 4 in.(102mm)width of TAM-
minimum of 3/8 in,thickness and applied in accordance with the PRO® SBS Flashing Cement,TAMKO or TAM-PRO® Plastic Roof
recommendations of APA-The Engineered Wood Association. Cement,orTAMKO Tam-Seal Adhesive.Caution:Apply ONLY a thin
SHEATHING BOARDS Boards shall be well-seasoned tongue- uniform layer of adhesive less than 1/8 in.(3mm)thick. Excessive
and-groove boards and not over 6 in.nominal width.Boards shall amounts can cause blistering of the shingles and may soften the
be a 1 in. nominal minimum thickness. Boards shall be properly asphalt in certain underlayments resulting in the asphalt flowing,
spaced and nailed. dripping and staining.Shingles must also be fastened according to
the fastening instructions described below.
8.VSNTMA"ON Correct placement of the fasteners is critical to the performance of
the shingle.If the fasteners are not placed as shown in the diagram
Inadequate ventilation of attic spaces can cause accumulation of and described below,this will result in the termination of TAMKO's
moisture in winter months and a build up of heat in the summer. liabilities under the Limited Warranty.TAMKO will not be responsible
These conditions can lead to: for damage to shingles caused by winds in excess of the applicable
1.Vapor Condensation mph as stated in the Limited Warranty.See Limited Warranty on the
2.Buckling of shingles due to deck movement. wrapper or tamko.com for details.
3.Rotting of wood members. FASTENING PATTERNS:Fasteners must be placed 6-1/8 in.from
4.Premature failure of roof. the bottom edge of the shingle,penetrating through the common
bond,and located horizontally as follows:
To insure adequate ventilation and circulation of air,the ventilation 1)Standard Fastening Pattem.(For use on decks with slopes 2
system must include inlets and outlets.This may be accomplished with in.per foot to 21 in.per foot.)One fastener 1 in.from each end and
a combination of ridge and soffit vents or by using gable end vents. one 13-1/2 in,from each end of the shingle for a total of 4 fasteners.
FHA minimum property standards require one square foot of net free (See Standard Fastening Pattern illustrated below).
ventilation area to each 150 square feet of space to be vented.This
may be reduced to one square foot of ventilation area per 300 square STANDARD FASTENING PATTERN
feet if at least 40%and not more than 50% of venting is provided FASTENERS NAIL ZONE
not more than 3 feet below the ridge or if a Class I or 11 vapor barrier COMMON
is installed on the warm in winter side of the ceiling in climate zones
BOND
6,7,and 8 as recommended by the 2012 International Residential FEXPOSUREs-SW
Code.For more information consult your design professional.If the
ventilation openings are screened,the total area should be doubled. 1 12-1/2"-►�-12-3/S•- 12-1/2"-+) �-1"
IT IS_PARTICULARLY IMPORTANT TO PROVIDE
ADEQUATE VENTILATION, (Continued)
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 09/19/14
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tamko.com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 1
(CONTINUED from page 1) FORMERLY HERITAGE"30
TAMK4 ®
Hninece
LMINATO ASPEW SHINGLES
1311MOING PROBVIC" Dallas,TX a Frederick, MD *Joplin, MO e Phillipsburg, KS
2) Mansard Fastening Pattern. (For use on decks with slopes be a minimum of 1-1/4 in.for new construction and 1-1/2 in.for
greater than 21 in.per foot.)One fastener 1 in.from each end and reroofing thus allowing a minimum deck penetration of 314 in.The
one fastener 8-1/2 in.from each end and one fastener 16 in.from Properly Driven Improperly Driven
each end for a total of 6 fasteners per shingle.(See Mansard and Lrdwddven averdrwn 01,00W
High Wind Fastening Pattern illustrated below.) A
MANSARD AND HIGH WIND WARRANTY FASTENING PATTERN Shing6s
FASTENERNAIL ZONE
S'Zy
COMMON
BOND
6-118" n EXPOSURE S-SW crown of the staple must be parallel to the length of the shingle.V� n The staple crown should be driven flush with the shingle surface.
I" F-11" Staples that are crooked,underdriven or overdriven are considered
3)High Wind Warranty Fastening Pattern.(For High Wind Warranty improperly applied.
Application requirements)One fastener I in.from each and. One CAUTION: ALL FASTENERS MUST BE DRIVEN INTO THE
fastener 8-1/2 in.from each end and one fastener 16 in.from each NAIL ZONE COMMON BOND AS SHOWN IN THE FASTENING
end for a total of six(6)fasteners per shingle. In addition to this PATTERN DIAGRAMS.
shingle fastening pattern requirement for High Wind Application,
TAMKO also requires the use of TAMKO starter shingles including 4.UDZRWMMT
sealant strip at eaves and rakes.Alternatively,along rakes,cement UNDERLAYMENT. An underlayment must be applied over the
shingles to the underlayment and each other in a 4 in. (102 mm) entire deck before the installation of TAMKO shingles.Failure to add
width of TAM-PRO@ SBS Flashing Cement,TAMKO or TAM-PROS underlayment can cause premature failure of the shingles which is
Plastic Roof Cement,or TAMKO Tam-Seal Adhesive.Caution:Apply not covered by TAMKO's Limited Warranty.
ONLY a thin uniform layer of adhesive less than 1/8 in.(3mm)thick.
Excessive amounts can cause blistering of the shingles and may Products which are acceptable for use as underlayment are:
soften the asphalt in certain underlayments resulting in the asphalt -e
-aft S toLated F-ItUnded nts-
a -- -_o -- aym
flowing,dripping and staining. SuperX 30TM Underlayment
High Wind Application is offered on new construction or complete TAMKO No.15 Asphalt Saturated Organic Felt
tear-off applications only.It is not offered for recover applications. Any TAMKO non-perforated asphalt saturated organic felt
If High Wind Application requirements are not followed, the High A non-perforated asphalt saturated organic felt which meets
Wind Application Warranty MPH,as stated on Table I in the Limited ASTM:D226,Type I or 11 or ASTM 04869
Warranty,reverts to the Standard Application Wind Warranty MPH
limit. (See Mansard and High Wind Fastening Pattern illustrated Tam-ShieldO Synthetic Underlayment or Synthetic Shield
above.) Underlayment
NAILS:TAMKO recommends the use of nails as the preferred method TAMKO TW Metal and Tile Underlayment,TW Undedayment
of application. Standard type roofing nails should be used. Nail and Moisture Guard Plus@ (additional ventilation may be
shanks should be made of minimum 12 gauge wire,and a minimum required. Contact TAMKO's Technical Services Department
head diameter of 3/8 in.Nails should be long enough to penetrate for more information.)
3/4 in,into the roof deck.Where the deck is less than 3/4 in.thick, A self-adhesive underlayment designed for use with asphalt
the nails should be long enough to penetrate completely through shingles which meets ASTM D1970.
plywood decking and extend at least 1/8 in.through the roof deck.
Drive nail head flush with the shingle surface. ForAs hgjLSAturjated_e Itt-Undedayment
p_
Apply the felt when the deck is dry.On roof decks with slopes
wop"Drh— bw"*"0ItvW 4 in,per foot and greater apply the felt parallel to the eaves
SW roln dion," aOder&im aw*ir GI-W lapping each course of the felt over the lower course at least
A 2 in.Where ends join,lap the felt 4 in.If left exposed,the felt
S
KI" may be adversely affected by moisture and weathering.Laying
rj.*j"9 of the felt and the shingle application must be done together.
For All Other SpAcia-11 -Underlay
ments.
sbaW4 good pmWMIW% I"doquato t-d"p.wte I..dwaft
IuW fl-h with shlog%4urft- pwmtmUon IRO shk%W snOha,me On roof decks with slopes 4 in, per foot and greater apply
the underlayment parallel to the eaves in accordance
APj_ES.If staples are used in the attaching process,follow the with underlayment written application instructions. The
above instructions for placement.All staples must be driven with underlayment should not be left exposed for a longer period of
pneumatic staplers.The staple must meet the following minimum time than is specified in the underlayments written application
dimensional requirements.Staples must be made from a minimum instructions,The final roof covering must be installed before
16 gauge galvanized wire.Crown width must be at least 15/16 in. the structure is exposed to adverse weather conditions,such
(staple crown width is measured outside the legs).Leg length should as wind driven rain,high wind,hail,ice storms,etc. {Continued)l
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 09/19/14
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tamko.com Southwest District 7910 S.Central Exp,, Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 2
TAMK :] (CONTINUED from page 2) FORMERLY HERITAGE"'30
e HERITAGE®
BUDDING PRODNCTS LAMINATED ASPHALT SHINGLES
Dallas,TX • Frederick, MD - Joplin, MO • Phillipsburg, KS
In areas where ice builds up along the eaves or a back-up of water of shingle to start the fourth course and use the remaining 10-3/8
from frozen or clogged gutters is a potential problem, TAMKO's in.piece to begin the fifth course.Continue up the rake in as many
Moisture Guard Plus®, TW Metal and Tile Underlayment or TW rows as necessary using the same formula as outlined above.
Underlayment (or any specialty eaves flashing product) may be The butt of the shingle should be aligned with the top edge of the
applied to eaves,rakes,ridges,valleys,around chimneys,skylights sawtooth of the underlying shingle for a 5-5/8 in. exposure (see
or dormers to help prevent water damage. Contact TAMKO's shingle application drawing illustrated on this panel). When you
Technical Services Department for more information. make your final cut at the roof's edge,flip any pieces that are 8 in.or
Substitute products as shingle underlayment should not be used. longer back onto the roof.These pieces can be worked in anywhere
without creating zippers or color variations.
6.APPLICATION IIISTRIICTtONS NOTE:Do not align joints of shingle courses when working in cut
STARTER COURSE:A starter course may consist of TAMKO Shingle pieces.Joints should be no closer than 4 in.from one another.
Starter,TAMKO 10-inch Starter or self-sealing 3-tab shingles.If self-
sealing 3-tab shingles are used,remove the exposed tab portion and
install with the factory applied adhesive adjacent to the eaves.Attach 1 �W a�p w gleeto�ke29za da10318•
lengththe starter course with approved fasteners along a line parallel to a 16 a,'e•1-0.
and 1.5 in.to 3 in.above the eaves edge.The starter course should :
overhang both the eaves and rake edges 1/4 in.to 3/8 in.if drip edge
flashing is not used along the eaves or rakes.If drip edge flashing 23• 6„s
is present,install shingles even with the drip edge. =
For—i,—wind—Wan.along nates,insa!any -
TAMKO slater Shingle indilding sealant or eem W slkhgks
to ubalayment arM e..h other in•4"(172 mm)width or -
TAM-PROL SRS Flashing Cement TAMKO or TAM-PRO& Ur�dalaymera Oaok
Ptotic Roof Caned,or TAMKO Tam-Sed Adhew.e.
Eaw lad h or _
asphalt aldbu t d fall
IMP-� Re9in appiraton with a fuN kngtn shingle.
edge - ................................... - _— al 8neg glow aB 23',163A1'and 103.'8'kngths,
RakeM-- " As You cn see,three shingles with two s
- make five onuses.
Feateoers -�
looed 1-1
on—
located 3'
'r =--- 3.11n.1
_ l way
__the_Menmake_
pm rake edge .. \ _'�h tl.ACo ffi roofs do.,$.any Pieces that are y longs
1
back ado the rad.These pieces can be waked in anywhere wdhmd
/ crea8rig o ncA li cats v.ofWhis.
NQfE:De rql align(oirrh of Mkrgk pounce aawl halMdng in
SW errs trip with tr2 shingle Starter stop,ovaharg Set_W, Eaw FaYt.— Dnp edge eul Dicers.Jokte ata ld M m sloth/than 4'horn one atodw.
removed.then folow with fut veer and ekes adheawe located
ergs h ankh to onset with the 114'to 34r t no drip edge postned 1-1rr to
Ars shingle course, faahing ie present.If drip sing eawas from saw edge
wi
edge Aaaingle is ent or nab edge S.LOINS SLOPE APPLICATION
.d o.shingles lana
trip edge.
SHINGLE APPLIC-A—TION:Start the first course with a full size shingle On pitches 2 in.per foot to 4 in. per foot cover the deck with two
and overhang the rake edge 1/4 in.if drip edge is not present.If layers of underlayment. Begin by applying the underlayment in a
drip edge is present,align shingle edge with drip edge flashing.Cut 1/2-sheet width along the eaves and overhanging the drip edge
10-3/8 in.from a full shingle to form a shingle 29 in.long.Use this by 1/4 to 3/4 in. Place a full-sheet width over the 1/2-sheet width
to start the second course(see diagram below).Cut a 23 in. long starter piece,completely overlapping it.All succeeding courses will
shingle to start the third course.Use the remaining 16-3/8 in.piece be positioned to overlap the preceding course by 1/2-sheet width.
If winter temperatures average 25eF or less, thoroughly cement
10-3/8" the laps of the entire underlayment to each other with TAM-PRO
or TAMKO Plastic Roof Cement from eaves and rakes to a point
of a least 24 in. inside the interior wall line of the building.As an
1e spa 10-3m" of
alternative,TAMKO's Moisture Guard Plus®,TW Metal and Tile
Underlayment, or TW Underlayment self-adhering underlayment
4: may be used in lieu of the cemented felts.
1rr�a• �-
rake 7.MANSARD ROOK OR STEEP SLOPE ROOK
iF;i
1° If the slope exceeds 21 in.per foot(60',each shingle must be sealed
su cauraa 16 with TAM-PROS SBS Flashing Cement, TAMKO or TAM-PRO®
76„3x. Plastic Roof Cement, or TAMKO Tam-Seal Adhesive immediately
'�`° upon installation.Quarter-sized dabs of cement or adhesive must
3rd Dmt,w ser• be applied to shingles with a 5-5/8 in.exposure,use 6 fasteners per
2nd Cdl.fe z shingle.See Section 3 for the Mansard Fastening Pattern.
istcwna '`
lo-are•
(Continued)
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 09/19/14
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tamko.com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 3
® (CONTINUED from page 3) FORMERLY HERITAGE"30
TAMKO HERITAGE®
BUILDING PRODUCTS LA MINAMM ASPIIAIiI' SHINGLES
Dallas, TX a Frederick, MD - Joplin, MO • Phillipsburg, KS
a.N&B0onne 8.W W=APPLMMON
Before re-roofing,be certain to inspect the roof decks.All plywood shall Over the shingle underlayment,center a minimum 36 in.wide sheet of
meet the requirements listed in Section 1. Moisture Guard Plus',TW Metal&Tile Underlayment,or a minimum
it is not recommended to install laminated asphalt shingles directly 50 Ib. roll roofing in the valley. Nail the underlayment only where
over existing laminated shingles due to the unevenness of the existing necessary to hold it in place and then only nail the outside edges.
mufti-layered shingles.The performance of the sealant feature may be IMPORTANT PRIOR TO INSTALLATION WARM SHINGLES TO
compromised,preventing the d shingles
gles o sealing properly.Itis PREVENT DAMAGE WHICH CAN OCCUR WHILE BENDING
acceptable to install laminated shingles ovd'existing three-tab strip SHINGLES TO FORM VALLEY.
shingles which are flat and essentially intact.Nail down or remove curled
or broken shingles from the existing roof.Replace all missing shingles After valley flashing is in place:
with new ones to provide a smooth base.Shingles that are buckled Apply the first course of shingles along the eaves of one of the
usually indicate warped decking or protruding nails.Hammer down all irTtersecting roof planes and across the valley.
protruding nails or remove them and refasten in a new location.Remove
all drip edge metal and replace with new. Note:For proper flow of water over the trimmed shingle,always
If re-rooting over an existing roof where new flashing is required to start applying the shingles on the roof plane that has the lower
protect against ice dams(freeze/thaw cycle of water and/or the backup slope or less height.
of water in frozen or clogged gutters),remove the old roofing to a point . Extend the end shingle at least 12 in.onto the adjoining roof.
at least 24 in.beyond the interior wall line and apply TAMKO's Moisture Apply succeeding courses in the same manner,extending them
Guard Plus® TW Metal and Tile Underiayment,or TW Underlayment.
across the valley and onto the adjoining roof.
Contact TAMKO's Technical Services
Department for more information.
Measurements will vary when nesting over an existing 5 in.exposure • Press the shingles tightly into the valley.
single roof:Call TAMKO Technical Services for further information. a Use normal shingle fastening methods.
The nesting procedure described below is the preferred method for Note:No fastener should be within 6 in.of the valley centerline,
reroofing over existing metric size shingles with a 5-5/8 in.exposure. and two fasteners should be placed at the end of each shingle
See description below: crossing the valley.
Starter Course:Remove the tabs and an additional portion from the . To the adjoining roof plane,apply one row of shingles vertically
head of a full size shingle so that its height is equal to the exposure of facing the valley and 2 in.back from the valley centerline.
the existing shingles.Position the resulting strip over the existing roof
edge(with the factory-applied adhesive strip along the eaves). Cut Note: For a neater installation, snap a chalkline over the
approximately 6 in.from the rake end and apply the remaining portion at shingles for guidance.
the eaves.Continue the starter strip by applying full length shingle strips To complete the valley, apply shingles on the adjoining roof
cut to height as above,evenly along the existing roof at the eaves.The
existing roof should overhang the eaves far enough to carry water plane by positioning the tip of the first shingle of each row at
off into the gutter.H this is not the case,cut and apply the starter the 2 in.point from the centerline where the edge of the vertical
strip so that it will provide sufficient overhang for proper drainage. shingle has been applied,covering the vertical shingle.
Minimum 36'wide sheet Valley centerline
of Moisture Guard Plus,
i v l
TW Metal B Extra nail in
131y" ! v�J Tie or 50lb_or
'� l
r end of shingle
heavier roll roofingExtend end shingle
valley�edind
Om edge' \ .( � //�
-Odp edge
New ehinAlea' / //j'
Underlayment No fosterers within
6'of centerline
5518"� �-3518'wy
ill
Frost Cowse:Remove an amount from the butt edge of a full-size shingle
so that the remaining portion of the shingle fits between the butts of the
existing third course.This course must also be applied evenly along the
eaves edge of the new starter strip. Place tip of shingle on the edge of
Second and SAcoeding Courses:Remove 10-3/8 in.from the rake
the vertical ceentteenine ra d tes ng
end of the first shingle in the second course, and continue with full the vertical shingle.
width shingles for the remainder of the course,placing the top edge of
each new shingle against the butt edge of the old shingle in the course FOR ALTERNATE VALLEY APPLICATION METHODS, PLEASE
above.This method should create an exposure of 5-5/8 in.after the first MKO'S TECHNICAL SERVICES DEPARTMENT AT
TA
CONTACT course.When beginning the succeeding courses continue to follow the COCO800-641-4691.TTA
Heritage application instructions.(See section 5).
(Continued)
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 09/19/14
Visit Our Web Site at Northeast District 4500 Temko Dr., Frederick,MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tamko.Com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 4
® (CONTINUED from page 4) FORMERLY HERITAGEe 30
TAMKO HERITAGFO
BMLMNG PBGBOCTS LANINA"M ASPHALT SHINGLES
Dallas, TX • Frederick, MD • Joplin, MO • Phillipsburg, KS
10.BIP AND BIDOB FAST6NIN0 DWABa
Apply the shingles with a 5-1/8 in.exposure beginning at the bottom
of the hip or from the end of the ridge opposite the direction of the
prevailing winds.Secure each shingle with one fastener on each side,
5-5/8 in.back from the exposed end and 1 in.up from the edge.
TAMKO recommends the use of TAMKO Hip & Ridge shingle
products.Where matching colors are available,it is acceptable to
use TAMKO's Elite Glass-Seal shingles cut down to 12 in.pieces.
Fasteners should be 1/4 in.longer than the one used for shingles
IMPORTANT. PRIOR TO INSTALLATION, CARE NEEDS TO BE
TAKEN TO PREVENT DAMAGE WHICH CAN OCCUR WHILE
BENDING SHINGLE IN COLD WEATHER.
Direction of prevailing wind
,Start 5-1/8"exposure
e
ere. F—
e.,
:^Fastener
�; yl
Start
here 5-1/8'exposure
THESE ARE THE MANUFACTURER'S APPLICATION
INSTRUCTIONS FOR THE ROOFING CONDITIONS
DESCRIBED.TAMKO BUILDING PRODUCTS, INC.ASSUMES
NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING
DEFECTS RESULTING FROM FAILURE TO FOLLOW THE
MANUFACTURER'S INSTRUCTIONS. FAILURE TO FOLLOW
THESE INSTRUCTIONS WILL ADVERSELY AFFECT COVERAGE
UNDER THE LIMITED WARRANTY. SEE THE LIMITED
WARRANTY FOR DETAILS. IF YOU HAVE ANY QUESTIONS
REGARDING THESE APPLICATION INSTRUCTIONS, PLEASE
CONTACT TAMKO'S TECHNICAL SERVICES DEPARTMENT AT
800-641-4691.
Information included in these application instructions was current at time of printing.To
obtain a copy of the most current version of these application instructions,visit us ordine
at tamko.com or call us at 800-641-4691.
TAMKO®,Moisture Guard Plus®,Tam-Shield®,TAM-PRO®and Heritage®are registered
trademarks and SuperX 30 is a trademark of TAMKO Building Products,Inc.
Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 09/19/14
Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055
Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656
tamko.com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834
Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 5
JP69909