HomeMy WebLinkAboutWind Load Calculation 191E Corporate Drive
Rnyntcn Beach,FL33426
WI ` �� WPh.561 322-6747
NFax.561--292-3562
Property Information Building Information
Owner: Sandra F Silasavage lVind Zone: 160 MPH.
Address: 10 10 1 Bluefield Road Exposure Category: C
Okechobee, FL 34952 M inimum Building Dimension: 41 ft.
Mean Roof Height: 11 ft.
Risk Category: 11
Design Pressure Calculations
€:&'E6S12BL88�:8R'SS:E:,TBIIh'/x - 3IIE&SRffilSCY23L9:SIIII£Sw'.Eff8Z�:5ASSii9..3Rf�E�®H'8S6.S$35&3SlZOffiIiHIiIIII[ T]ti'SITY:SG®28iIDH- LSTiFZt� PL�Y.'t.'f.ffi8E®
Opening Location Device Device Device Max Positive Max Negative
Number Zone ] Width(in) IF Height(in) [- Elevation(ft) Pressure(psf) Pressure(psf)
1 lilt 36 37 7 33.5 -36.3
2 End 36 49 7 33.0 -43.9
3 lilt 36 37 7 33.5 -36.3
4 lilt 36 49 7 33.0 -35.9
5 lilt 36 37 7 33.5 -36.3
6 Int 36 37 7 33.5 -36.3
7 Int 36 37 7 33.5 -36.3
8 Int 36 49 7 33.0 -35.9
9 Int 36 37 7 33.5 -36.3
10 Int 36 37 7 33.5 -36.3
---.._..._._....... .._.._.__._._._-.._......- --...................
..----------------— ...----
11 Int 52 49 7 32.2 -35.1
12 Int 52 49 7 32.2 -35.1
Prepared in accordance with:ASCE 7-10.Chapler 30. Mnd Loads-Conrpon:-nts and Cladding.5th Edition(2014)Florida Building Code.
Page 1 of 1
MNDOW Z,
A FLOOR PLAN!WITH OPENING IDENTIFICATION SHOULD D Di PROVIDED WITH THIS
Definition of Corner Zone -10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft.
OPENING (Location) IS THIS A PRODUCT
PRODUCT APPROVAL REQUIRED OPENING MAXIMU ROUGH MULTIPLE
ARE
GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW
LOCATION Corner Zone WINDOW TYPE ACCEPTANCE TESTED OPEiviivG REQ Y/N/NA SHU T I ERS
NUMBER or Interior OR DOOR NUMBER (+)PSF (-) PSF (+)PSF (-)PSF DIMENSIONS MULLION REQ
SIZE Y/N
1 Int W '/8"UmiIG FL 11413.2 55 55 33.5 36.3 53x77 36x37 N N
2 End W "$"Lami'G FL 11410.2 55 I 55 33.0 43.9 36X68 36x49 I N ! N
3 Int W 7/8"Lami IG FL 11413.2 55 55 33.5 3 6.3 53X77 3 6x3 7 N N
4 Int W ;;s"La"'i'G FL 11410.2 55 55 33.0 35.9 36x6 36x49 N N
5 Int W 7/9"Lan,i IG FL 11413.2 I 55 55 33.5 36.3 53X77 36x37 N N
6 Int W 7/8"Lami 1G FL 11413.2 55 55 33.5 36.3 53X77 36x37 N N
7 I Int W 78"LamiIG FL 11413.2 55 I 55 33.5 I 36.3 53x77 ; 3607 N i N
8 Int W 7/
8"Lami'G FL 11413.2 55 55 33.0 35.9 53x77 36x49 N N
9 Int W 7/8°Lami 1G FL 11413.2 55 55 33.5 36.3 53X77 3607 N N
10 Int W 7/8"La0u1G FL 11413.2 55 55 33.5 36.3 53x77 3 6 x 3 7 N N
11 Int W 7/8"Lanu10 FL 11411.2 55 55 32.2 35.1 74X63 52x49 Y N
12 Int W 7/8"Lami IG FL 11411.2 55 55 32.2 35.1 74x63 52x49 Y N
9
I
1