HomeMy WebLinkAboutProduct Approval (2) 811`x+24#5 Florida Building Code Online-,
-1 F b { YfYfNY A
g'E � U -
&aN�,.�5rt{ � &. .G+,, .f$',K sit-+ F E8Sa1 L' AL�Vk° Yi
cam-sz4 q�€ 3 'em
w, �a�s.. apt¢ev'4 �
.isr.,r4"t SCIS Home Log In User Registration d Hot Topic, Submit Surcharge Stats&Facts PubftcaUons FBC Staff BUS Site Map Un" Search -
s
'Business'
Approvai
USIEW Public User oessitna
@I # Product Aoorowl Menu>Product or Application Search>goofication List>Application RotvB '
MEN= FL# FL11410 .
Application Type Revision F+i 4 �t°L 4 .
Code Version 2014 t'. V
Applkation Status Validated
Cotrcrients
Archived
Product Manufacturer Regency Pius Incorporated
Address/Phone/Email 1024 Locust Gap Hkjhway
Mount Carmel, PA:17851
(570)339-3374
tonyp@cons6rvationwindows.com.
Authorized Signature Tony Pmcoplo
tonyp@conservat ionwindows.com;
Technical Representative Joe.Korzenlecki
Address/Phone/Email 2000 Locust Cap Hely.
Mount Carmel,SD 17851
(570)339-3374
joek@window-pros,info
I;
` Quality Assurance-Representative Joe Korzeniecki
Address/Phone/Email 2000 Locust Gap Hwy.'
Mount Carmel, PA 17851
(570)339-3374
joek@wi nd ow-pros.into
PA --- ,,
Category Windows
Subcategory Caseti>rat S
Compliance Method Certification Mark or Listing
Certification Agency National Accreditation.&Management institute
Validated By National Accreditation&L Managernent Institute,
Referenced Standard and Year(of Standard) Standard Yeah
AAMA/NWWDA101/r.S,2-97 19 T
TAS 201 1994
TAS 202 1994
TAS 203 , 1994
Equivalence of Product Standards
Certified By
Product Approval Method Method 1 Option A
x Date Submitted 08!13/2015
Date Validated 08/17/2015
/ryai building.otg/prlpr p_l.asp�OP��++PGE1/XQWDq�fikAgZgMEE7n3AEJU.91SSsQir�1kdFWl%Z,+DrexJ7vP/o3de/o3d
8MW4115 Florida Building Cocom Online
summa ry.of Product M.
FL* Piiodel,hlumber or Mame Description
114101 1 Series 2000 Casernank Series 2000 Casement Window-Non Irrpact
Limits.of Use Certification Agency Certificate
Approved for use In HVHZ:No FL11410 133 C CAC Mf106321-RS odf
Approved for use outside ii4►}BL Yes Quality Assurance Contract Expiration Date j
]Impact Resistant.,No 12/31/2021 a
Desl4n pressure*+45/-45 ;Installation Instructions
Other. ELI 410 R3 II 0& 0 99.odf
i Verified By: Luis R.Larres,P.E.62514
Created by Independent Third Party:Yes
Evaluation Reports: i
FL11410 R3 AE 513474,2rtf
r
E
Created by Independent Third Party:Yes
i
11410.2 Series 5205 Casement Series 5205 I Vinyl y --pact Casement Window
Lime of Use Certification Agency Certificate
Approved for use In IHVHZQHyes
FI 11410 R3 C CAC N1006316A- 3 Ddf
Approval for use of tslflef es Quality Assurance Contract Expiration Date
i
Impact-Reuistarrh Yes 09/30/2021
Design pressure: t55/-55 E installation Instrefctions.
Other:FRAME MATERIAL TO BE RIGID PVC FROM ROYAL WINDOW I FLU d?0 R3 II 08-0Z700A.odf
&DOOR PROFILES,PLANT 1,VEKA AAMA CERTIFIED(DOM-1). i Verified By: Luis R Lomas,P.E.62514
i Created by Independent Third Party:Yes
Evaluation Reports;
j FL1141Q_R3 AE t,i-0129,27-COMP odf
F111410 R3 AE 1.3012927,Dd
i FL11410 R3 AE 513460A odf
Created by Independent Third Party:Yes
Contact lis-::
1.940 North Monroe Street;Tallahassee FL 32399 Phone:-850-487-1824
The State of Florida;is an AA1EEo employer.Copyright 2007-2013 State of Fiodd;s.::privacy Statement Accessibility SUte ent::Refund Statement
Under Florida lav-,email addresses are public records.If you do not vent youre-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail,If you have any questions,please contact 650.487,1395.'Pursuant to
Section 455.275(1),Florida statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one,.The emails provided may be used for official communication with the licensee.Hoviever email addresses are public record.If you do not v"h to
supplya personal address;please provide the Department vith an email address which can be made available to the public To determine if you are a licensee
.. - under Chapter 455,F.S.,please dick here.
Product Approval Accepts.
W lL lyw CM
S �
ik
i
hti IA"idafxiltbrg orgfDl'"W-ffl-asivOWP ir-vvGE1/XQIMDgAlyggZSV\AuEE/n3AEJU3ISSSOrnI8tZdFVulvZfii mj7W/,3dk3d 212
y L. Roberto Lomas R.B. Engineering Evaluation Report
233 W.Main St
Danville,VA 24141 Report No.. 5139180A
434-688-0609
rilomas@lrlomaspe.com
Manufacturer: Regency Plus, Inc.
2000 Locust Gap Highway
Mt. Carmel, PA 17851
Product Line: Series 5205 Vinyl Casement Window 36"X 68"-LMI
Compliance:
The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of
Business and Professional Regulation for Statewide Acceptance per Rule 61 G20-3.005 method 1(a).The product listed
herein complies with requirements of the Florida Building Code.
Supporting Technical Documentation:
1. Approval document:drawing number 08-02700, Revision A,prepared,signed and sealed by Luis Robedo Lomas
P.E.
2. Test report No.:NCTL 110-9697-1 signed and sealed by Robert H Zeiders P.E.
National Certified Testing Laboratories,York, PA
TAS 201-94 Large Missile Impact Test,Level.D,Wind Zone 4
TAS 202-94 Uniform Static Air Pressure,t55.Opsf design pressure, 12.Opsf water penetration.
TAS 203-94 Cyclic Pressure loading t55.Opsf design pressure
3. Anchor calculations, report number 513480-1,prepared,signed and sealed by Luis Roberto Lomas P.E.
Limitations and.Conditions of use:
Maximum design pressure: t55.0psf
o Maximum unit size: 36"x 68"
o Units must be glazed per ASTM El 300-04,see installation instructions for glass details.
U This product is rated to be used in the HVHZ.
o This product is impact resistant and does not require impact protection in And bomea;debris regions.
m Frame material to be rigid PVC.
Installation: Units must beiinstalled in accordance with approval document,08-02700,.Revision A.
Certiricaffon of Independence.- Please note that I don't have nor will acquire a financial interest in any company
manufacturing or distributing the product(s)for which this report is being issued.Also, I don't have nor will acquire a.
financial interest In any other entity involved in the approval process of the listed_product(s).
�eN �� ' d ��it
. . .
E did
• `� * ._
TATS 0
Ok .
0 R���:
ONA
1-0
1 of 1 Luis R..Lomas, P.E.
FL No.:62514
08/14/2015
aMSONS
.REV CESCR✓FMN RATE APPRWED
A REVISED RATING 08/13/15 R.L.
15. FOR ANCHORING THROUGH FRAME 114TO MASONRY/CONCRETE USE 1/4' TAPCONS WITH
1. THE PRODUCT SHOWN.HEREIN IS DESIGNED AND
MANUFACTURED TO COMPLY WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2
REQUIREMENTS OF THf� FLORIDA BUILDING CODE INCLUDING THE HVHZ. i/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND
2. WOOD FRAMING AND MASONRY OPENING TO.BE DESIGN TO PROPERLY INSTALLATION DETAILS,
TRANSFER ALL LOADS TO STRUCTURE, FRAMING AND MASONRY OPENING
IS THE
RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 16. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #12 SMS OR SELF
3. IX BUCK OVER MASONRY/CONCRETE IS OPTIONAL, DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND
4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1_/2" WINDOW UNITS MUST BE STRUCTURE INTERIOR WALL.. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION
DETAILS.
ANCHORED,THROUGH THE FRAME N ACCORDANCE WITH MANUFACTURER'S PUBLISHED 17.ALL FASTENERS TO BE CORROSION RESISTANT.
INSTALLATION INSTRUCTIONS.ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO 18.INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR
MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. MANUFACTURER'S.INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN
S. wilERE WOOD BUCK '1HICKN£SS IS 1-1/2" UR GREATER, BUCK SMALL 6E SECURELY SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW:
FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY A. WOOD — MINIMUM SPECIFIC GRAVITY OF G-0.42
BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH B. CONCRETE — MINIMUM COMPRESSIVE STRENGTH OF 3,192 PSL
"-NU' PUBLISHED INSTALLATION INSTRUCTIONS, C. MASONRY — STRENGTH CONFORMANCE TO ASTMC_90, GRADE N. TYPE 1 (OR GREATER). �
6. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED D. METAL STRUCTURE! STEEL 18GA, 33KS1 OR ALUMINUM 6063—T5 1/8" THICK MINIMUM
COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF
—THE ARCHITECT OR ENGINEER OF RECORD.
F17. BUCKS OND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS
lPROVIDED.. A
8. SHtM AS REQUIRED AT EACH ANCH N WITH LOAD BEARING SHIM. SHIM WHERE
SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4".
9. SHIMS SHALL BE LOCATED, APPLIED AND 14ADE FROM. MATERIALS AND THICKNESS CAPABLE
OF SUSTAINING APPLICABLE LOADS,
10. KIND LOAD DURATION FACTOR Cd-1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS.
11. FRAME MATERIAL: EXTRUDED RIGID PVC.
12. UNITS MUST BE GLAZED PER ASTM E1300-04, SEE SHEET 2 FOR CLASS DETAILS.
13. APPROVED IMPACT PROTECTIVE SYSTEM 1S NOT REQUIRED FOR THIS PRODUCT IN WIND
BORNE DEBRIS REGIONS.
14. FOP. ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #12 WOOD
SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/8" MINIMUM EMBEDMENT INTO
SUBSTRATE. LOCATE ANCHORS AS.SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
SIGNED:08/13/7015
REGENCY PLUS, INC.
\\\ >1+1I►Irrr���
2000 LOCUST GAP. HIGHWAY ��� \5 P. L�4f.��ii,
MT. CARMEL. PA 17851 �w•��G�N9iP��
TABLE OF CONTENTS SERIES 5265 VINYL CASEMENT WINDOW =sY" 0 51
SHEET NO. DESCRIPTION 36" X 68" LMI
NOTES TAT OF"'o,
1 NOTES muwN: owc No. REY
2 ELEVATION N.G.
3 — 4 INSTALLATION DETAILS SCALE NTS DATE 05/11/15 08-02700s•EETOF 4A
/' ►1fA�
..................... ............. ...............
............ ..............
36' MAX FRAME WIDTH REVISIONS
7'
acv DESCAdn= DATE APPROvED
PX FRAME A�WIDTH,
O.C. A REVISED RATING 108/13/15 R.L.
4" MAX
4` MAX
4- MAX
'
MAX O.C.0 C
10-
IA)IO.C.
MAX
FRAME
HEIGHT 7/8'
1/13" ANN,
.090' PV8 BY DUPONT
1/8" ANN.— 1/8" TEMP
EXTERIOR DESICCANT STEEL
SPACER
SYSTEM
11/16- BITE INTERIOR
C2, 0
SERIES 5205 VINYL CASEMENT WINDOW
EXTERIOR VIEW GLAZING.DETAIL
DESIGN FRESSUR5 RATIN IMPACT RAS
.AR61E
±0'.6PSF "
MWIL.'LEIMPACT
Z
MISSILE LEVEL Q,WIND ZONE 4 1 A.HVHZ
NOTES:-
i. -MAXIMUM SASH SIZE' 3�:5 /16 X 66 .3/115
2. MAXIMUM D.L.O.: 29 1/8 X 61 1/8
- SIGNED.03/13/2015
'REGENCY PLUS, INC.
2000 LOCUST GAP HIGHWAY N..�j .-�t\ FL..LO
- ' -.4i
AL CARMEL,. PA,17851
K4RDWARESCHEDUIE SERIES 5265 V'INYL,dASEMENT'VANDOVi qtr
A. ;1)SINGLE HANDLE 3-POINT LOCKS 112"FROMSILLON LOCK JAMB 36 X $a- Lml
S. (1)METAL KEEPER LOCK STILE AT LOCK LOCATIONS ELEVATION
T_ Ur
C. ID1
(1)STANDAR ROTO OPERATOR 9 3/9'FROM HINGE JAMB ON SILL ...
0 Nawo.
to,
At.
0.'(6)METAL SNUBBER ON HINGE STILE N.G.. 7 08-02700,
E. (1)GALVANIZED STEEL CHANNEL REINFORCEMENT-AT LARGESTVENrHoLLOwl Se"NTS DATE 0,5111/15 SHEET 2.OF 4
.m............ .............. .......... ............ . ...... ..................... ............................. .............. ................ .......... .............. ...... ....................... ...........
9/1"6" MIN. REVISIONS
EDGE DISTANCE RV DESCRIPTION SIR[ APPW tW
WOOD FRAMING METAL �--_{_ 7/B" A(IN q REVISED RATiND 68/13/15 R.L.
OR 2X SUCK STRUCTURE I EDGE DISTANCE
BY OTHERS 1 3/8" MIN, BY OTHERS
EMBEDMENT 1/4" MAX.
SHIM SPACE
APPROVED APPROVED 7/8" MI!N 0
SEALANT 1/4' MAX, 1 4" MAX.
SHIM SPACE SEALANT
IM SPACE T EDGE DISTANCE IdTERIOR
12 WOOD E12 SMS OR o�
B SEL SMS OR SELF DRILLING D
D SCREW Q SELF DRILLING SCREWS
SCREW
1 !
I I EXTERIOR
1 INTERIOR i INTERIOR STRUCTURE
BY OTHERS APPROVED
I I SEALANT
! ! JAfvlB INSTALLATION DETAIL
EXTERIOR i EXTERIOR j METAL STRUCTUREWSTALLAT70M
! 1
j1/4" MAX.
Mft SHIM SPACE
! I EMBEDMENT
d 1
! #12 WOOD ! 512 SMS OR
SCREW SELF DRILLING
a D SCREW 9/16' MIN. INTERIOR
EDGE DISTANCE
O ❑ p
� t 0
#12 WOOD +
APPROVED 11 APPROVED Ip SCREW
1/4" MAX, SEALANT V
SHIM SPACE 1/4" MAX.
SHIM SPACE WOOD FRAMING
WOOD FRAMING —� �� METAL OR EXTERIOR
BY OTHERS
vn cn oven i o/c iaiiv. arnwlvRE APPROVED
_ BY OTHERS. _,...
_ ... EM6EOMENT BY OTHERS JAMB INSTALLATION DETAIL
7/8" MIN WOOD FRAMING OR 2X BUCK INSTALLATION
9/16",MIN f- EDGE DISTANCE SIGNED:08/1312075
EDGE DISTANCE VERTICAL CROSS SECTION
VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION REGENCY PLUS, INC. \\�6lulunt/
WOOD FRAMING OR2xSUCK/NSTALLATION 2000
LOCUST
GAP HIGHWAY
CARMEL, A GENS flr��i
¢ _
SERIES 5205 VINYL CASEMENT WINDOW o bi *ti
NOTES: 36" X 68" LMI
f,INTERtORANOEXTERIOR i7ANSNES,BYOTNEAS, INSTALLATION DETAILS `�, TAT OF rL�
NOT SNOWJd FOR CL4RITY.
OES/GNED W ACCORDANCE2.PERIUETER AND EALANTOY STMET 2S TO BE wuwN; o+D ero. Rev iQ"k�;�1 p Rl
N.G.
09 00 A
NTS DATC 05/11/1$ sHcn3 OF 4