HomeMy WebLinkAboutWind Load Calculation ECEIV�
ME
RzNewSouth
Kp'
W1 N DOW SOLUTIONS
2526 Okeechobee Blvd,West Palm Beach,FL 33409•561-712-9000•CRC1330822
Property Information Building Information
Owner: SMITH,SHALONDA Wind Zone: 170 MPH.
Address: 4808 MYRTLE DR Exposure Category: C
FT.PIERCE,FL 34982 Minimum Building Dimension: 40 ft.
Mean Roof Height: 15 ft.
V jj� Risk Category:
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf)
1 Int 36 51 7 37.2 -40.4
2 Int 72 51 7 35.5 -38.7
3 Int 72 51 7 35.5 -38.7
4 Int 36 36 7 37.8 -41.0
5 Int 36 51 7 37.2 -40.4
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.51h Edition(2014)Florida Building Code.
Page 1 of 1