HomeMy WebLinkAboutProduct Approval morloa Binding Code Online
=� �"
+ r,
•" �.p 3 t SCiS Home Log In User Registration Not Topics 1 Submit Surcharge Stats&Facts I Publications + FBC Staff 8CIS Site Map Links Search
Busines �' � :, ,
Professional fir°` usEa Public
Regulation
Product Approval-Menu>Application Detail'
'�' 1; t168.42-R_ R2
;' "f Application Ty'e Revision
Code Version 2014
Application Status Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified
by the POC and/or the;Commission If necessary,
Comments
Archived
Product Manufacturer NewSouth Window Solutions
Address/Phone/Ema11 4901 oak fair blvd
tampa, FL 33610
(513) 284.0129
danochsteln@newsouthwindow.com
Authorized Signature Vivian Wright
rickw@rwbldgconsultarnts,com
Technical Representative
Address/Phone/Email
Quality Assurance Representative.
Address/Phone/Email
SubCdtegory Horizontal-Slider •�••---�'�- '
Compliance Method Certification Mark or listing
Certification Agency National Accreditation &Management Institute
Validated By Ryan 3. King, P•E,
Validation Checklist:- Hardcopy Received
Referenced Standard and Year (of Standard) Standard Year
AAMA/WDMA/CSA101/I,S,2/A440 2008
AAMA/WDMA/CSA101/ItS•2/A440 2005
ASTM E1886 2005
ASTM E1996 2006
ASTM E1996 2005
TAS 201, 202, 203 1994
Equivalence of Product Standards
Certified By
Product Approval Method Method 1 Option A
L
1ps://fl or id.abuildi ng.org/pr/pr_app_dtl,aspx?param=wGEVXQwtD qtm mTSTN dVPsf%2fLKgxApZZQM acKkAOnfZOl ll loRVQrXw`/o3de/a3d 1 rA
riurids tsunaing code Unline
Impact Resistant: Yes 01/30/2018
Design Pressure: N/A Installation Instructions
Other: See INST 16842,5 for Design Pressure Ratings, any FLI 842!R2 II Inst-16842,5.)d
additional use limitations, Installation Instructions and product Verified By: Lyndon F. Schmidt, P.E. 43409
particulars, Created by Independent Third Party: Yes
Evaluation Reports
Fl_16aA2� Sg Evals 16842,5,pdf
Third Party: Yes
....................................................1.................. ................................. ..................................... ........_____..1.............
168416 f, 9500,Silder XO - Impact Rated - Extruded Vinyl "Impact" Horizontal Sliding Window with
,HVHZ,-.,.. s ...........Tz 8anglepdristallatl {X4 or OX.configuratlons
MMM
Ap}pralved,A-- Teo on ftMM1
AMPA
'
T-
24
Q�
df
t 1 d H allAssurance CoratracExpiratlon Date
q'tytpU
0 1&'
Win
-Ml-
s� any 1 8420a
19 MF�r�e S S tire rKA'Ai
oa, -A,
Is "a CtIr
ont:%ndhp_0ductM'
r
F�$ hmidt RE 5434092
Pa 4In epenaz.
RA
eplo;
yd
04
�
�i h a e A V7,.,h I r d�R 4
",N, 'Ng
R
t
16842,7 9. 9500.3 Slider XOX Extruded Vinyl "Non-Impact" H&eI:t6ntaI'8IIdInM� dow
utilizing aNall Fin Installation (XOX, configuration)
Limits of Use Certlflcatl;o n Agency Certificate
Approved for use In HVHZ: No' FL16842 RIC CAC NAMI Cart for 16842,7 t11 x 631,pdf
Approved for use outside HVHZ, Yes Quality Aigurance Contract Expiration Date
Impact Resistant: No 01/31/201$
D.esIgn Pressure: N/A Installatill 0 Instructions
Other: See INST 16842,7 for Design Pressure Ratings, any FLIG842 R2 11 Inst 16842.7.pdf
additional use limitations, Installation instructions and product Verified By,: Lyndon F, Schmidt, P.E. 43409 II
particulars. Created by;Independent Third Party: Yes
Evaluation Reports
FLI 42.12 AE Evals 16842,7.r)d
Created by Independent Third J_ Party:-Yes
............... ..............__................ ......
.....................*.........-"-*..........' _*---------
16842.8 h. 9500-3 Slider XOX Extruded Vinyl "Non-Impact" Horizontal Sliding Window with
Flange Installation (XOX, configuration)
.................. ................. ......................___............... .......... ............I.- I............ I............ ..........................
Limits of Use Certification Agency Certificate
Approved for use In HVHZ: No FL16842_R2 C CAC NAMI Cert for 16842,8 f11 x 631.odf
Approved for use outside HVHZ, Yes Quality Assurance Contract Expiration Date
Impact Resistant: No 01/31/2018
Design Pressure: N/A Installation Instructions
Other: See INST 16842,8 for DVsIgn Pressure Ratings, any FL16842 P:,2. 11 Inst 1042,8.pdf•
additional use limitations, Installation Instructions and product Verified By:; Lyndon F. Schmidt, P.E. 43409
particulars, Created by Independent Third Party: Yes
Evaluationi Reports
FL16842 R2- AE Evals 16842.8,12d
Created by independent Third Party: Yes
............
............
............................... ............. ...................
16842.9 1. 9500-3 Slider XOX Extruded Vinyl "Impact" Horizontal Sliding Window utilizing a
Nall Fin Installation (XOX, confIguratlon)
.............__,_ _
,_ *.......... ....
........ ............................. .... ....................
Limits of Use Certification Agency Certificate
Approved for use In HVHZ: No FL16842 R2 C CAC NAMI Cert for 16$42,91111 x MW
Approved for use outside HVHZ., Yes Quality Assurance Contract Expiration Date
Impact Resistant; Yes 06/30/2018,
Design Pressure. N/A Installation-Instructions
Other: See INST 16842.9 for Design Pressure Ratings, any FLI 842 R2 II Inst 16842.9.pdf
additional use limitations, installation Instructions and product Verifled By':;Lyndon F. Schmidt, P,E. 43409
particulars, Created by;lndependent Third Party; Yes
Evaluation Reports
FL16842 R2 AE Evals 16a42.9.od
Created byIhdependent Third Party: Yes
................. ................................. .................... ...............1,............... ..............................
16842.10 J. 9500-3 Slider XOX Extruded Vinyl "Impact" Horizontal Sliding Window with
Flange Installation (XOX, configuration)
...................... .......... ............ .............. .......... ................................ ..................................................................................................
Limits of Use Certification Agency Certificate
Approved for use In HVHZ: No FL16842 R2 'C CAC NAMI Cert for 16842,10 f11 x 531.pd
Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date
Impact Resistant., Yes 06/30/2018,
Design Pressure: N/A Insta Ilatlon'Instruct Ions
Other: See INST 16842.10 for Design Pressure Ratings, any FL16842 R2; 11 Inst 16042,10,pdf
additional use limitations, Installation Instructions and product Verified By:1 Lyndon F, Schmidt, P,E, 43409
particulars, Created by Independent Third Party: Yes
Evaluation Reports
FLI 842 112' AE Evals 16842.10.r)df
Created by Independent Third Party: Yes
........... ...»._.._....._-._...»_.._......».....-................ ....... ..................... ........... ..........*..............------------
ttps:I/floridabuiIding,orgVpr/pr_appjtl.aspx?param=wGEVXQwtDqtmmTSTNdVPsf�/�2fLKqxApZZQMacKkAQnfZ01111oRVQrXw��/o3d%3d
rlorlda buiiding Code Online
Other: See INST 16842,16 for Design Pressure Ratings, any P 1x;842 92 II Inst 1684 , 6,Ddf f
additional use limitations, Instaliatlon Instructions and product Verified By: Lyndon F. Schmidt, P,E. 43409
particulars, Created by Independent Third Party: Yes
.' Evaluation Reports
E,SL 6842 M AE Evals 16642 16 adf
Created by Independent Third Party: Yes
16842,17W ~� q. SasnlLteYSlider XX Extruded:Vinyl "Non-Impact" Horizontal Sliding Window -
utilizing a.Nall Fln Installation (XX, configuration)
Limits of Use Certificatlon Agency Certificate i
Approved for use in HVHZ; No FL16842 IR2 C CAS' NAMI Cert for 16842 17 (72 x 60).pd
Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date
Impact Resistant: No 03/31/20j1;9
Design Pressure; N/A Installation Instructions
Others See INST 16842,17 for Design Pressure Ratings, any )1,16842 IR2. II Ihst 16842.17,odf l
additional use limitations, Installation Instructions and product Verified By: Lyndon F. Schmidt, P.E. 43409 i
particulars. Created by Independent Third Party: Yes
Evaluatio',n Reports
FL16842 R2 AE Evals 16842 17 Ddf 1
Created by Independent Third Party: Yes
16842,18 r. Sashllte Slider XX Extruded Vinyl "Non-Impact" Horizontal Sliding Window (XX,
configuration)
_._..._.......
.......... _.........._...._..........................................._..._......_._._._..........................................._......._............................:..._..._.._........._.................................................._......_..................-....-,--.._...._.... ._....... ...;
Limits of Use Certification Agency Certificate
Approved for use In HVHZ: No FL16842 122 C CAC NAMI Cert for 16842,18(72 x 60).Ddf
Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date
Impact Resistant: No 03/31/2019 I
Design Pressure: N/A Installation Instructions
Other: See INST 16842,18 for Design Pressure Ratings, any FL 16842 R2 II Inst 16842,18_pd_f
additional use limitations, Installation Instructions and product Verified By: Lyndon F. Schmidt, P,E, 43409 I
particulars, Created by Independent Third Party: Yes
Evaluation Reports
FL16842 R2 AE Evals 16642.18,12df j
Created by Independent Third Party: Yes i
........_,......................_•_........................_..................__......................._...................._-_.•.._.........._...,..... _._..._..................................•.....,........._....................................._......_....................
_...__..__._...
16842,19 s. Sashllte - 3 Slider XOX Extruded Vinyl "Non-Impact" Horizontal Sliding Window i
utilizing a Nall Fin Installation (XOX, configuration) ,
Limits of Use M Certification Agency Certificate
Approved for use In HVHZ; N4 FL16842 R2 C CAC NAMI Cerk fqr 16842 19(112 x 60) Ddf j
Approved for use outside HVHZi Yes Quality Assurance Contract Expiration Date i
Impact Resistant: No • 03/31/201'9 l
Design Pressure: N/A Installation Instructions
Other: See INST 16842.19 for Design Pressure Ratings, any FL16842 R2 II Inst 16842.19.Ddf j
additional use limitations, Installation Instructions and product Vertfled By: Lyndon F, Schmidt, P,E, 43409 L
particulars, Created by Independent Third Party: Yes j
Evaluation Reports
FL16842 R2AE Evals 16842,19,odf
Created by independent Third Party: Yes
............_.. ._.___--_ _-------_
___.___.....__...._ _._....._..____.__._._____....._.__.._................__..._....._ .... ___...._,.._....__........._.._._.. .......__ _. ............._..____ _._._ ..
Sashll
............ i
' 16842,20 t, te - 3 Slider XOX Extruded Vinyl "Non-Impact" Horizontal Sliding Window (XOX,
configuration) I
Limits of Use _ Certification Agency Certificate
Approved for use In HVHZ; No FL16842 R2 C CAC NAMI Cert for 16842 20(112 x 60) Ddf
Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date i
Impact Resistant: No 03/31/2019
Design Pressure: N/A Instailatlo'n Instructions
other: See INST 16842,20 for Design Pressure Ratings, any FL 6842 RAZ; II Inst 16842.20.Ddf i
additional use limitatlons, installation instructions and product Verified By:,Lyndon F. Schmidt, P,E, 43409
particulars. Created by Independent Third Party: Yes
Evaluation!Reports
FL16842 R2, AE Evals 16842,20•Ddf i
Created by Independent Third Party: Yes
Go to Page 4 S i Page 1/ 2 1 Q)
• T3r,,:': Wrx:.
Contact Us is 1940 North Monroe Street.Tallahassee F6 32b99 Phone! 850.4871824
The State of Florida Is an AA/EEO employer,Coovrloht 2007.2013 State of Florida. ;; Privacy Statement:: Accessibility Statement::;mound Statement
Under Florida law,email addresses are publlc records.If you do not want your e-mail address releasgd In response to a publlc•records request,do not send electronic
mall to this entity. instead,contact the office by phone or by traditional mail,If you have any questions,please contact 850,487,1395.*Pursuant to Section
455.275(1),Florida Statutes,effective October 1, 2012,licensees licensed under Chapter 455,F,S, must provide the Department with an email address if they have
one,The emalls provided may be used for official communication with the licensee.However email addresses are public record.It you do not wish to supply a
personal address,please provide the Department with an email address which can be made avallable to the public,To determine If you are a licensee under Chapter
455,F.S„please click 11€Cq_.
Product Approval Acceptst
tips://floridabuiiding,org/prlpr_app dti,aspx?param=wGEVXQwtDgtmmTSTNdVPsf%2fLKgxApZZQMacKkAQnfZ01111oRVQrXw%3d%3d r1A
NOTICE OF PRODUCT CERTIFICATION
r ct ' CERTIFICATION NO: N1011847-R2
_at DATE: 02/07/2014
CERTIFICATION PROGRAM: Structural
COMPANY: NewSouth
CODE: 2013-1
► � �°
REVISION DATE: 08/03/2015
To verify that the"Notice of Product Certification"is valid,please visit www.NAMICertification.com to assure that the
product is active and currently listed.This certification represents product conformity to the applicable specification and
that certification criteria has been satisfied. ANAMI approved certification.label must be applied to the product to claim
certification status. Please review and advise NAM1 if any corrections are required to this document.
COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION
NewSouth Window Manufacturing, LLC Series "9500"
4901 Oak Fair Boulevard Horizontal Roller
Tampa, FL 33610 Vinyl Horizontal Sliding Window
Configuration:XO
Glazing: IG-1/8"Annealed Glass/Laminate-1/8"
Annealed Glass/0.090"PVB Interlayer/1/8"Annealed
Glass
Frame: W-1879mm(74.00") H-1600mm(63.00")
Vent: W-934mm(36.81") H-1541mm(60.68")
DLO: W-844mm(33.25") H-1487mm(58.56")
SPECIFICATION PRODUCT RATING
TAS 201/202/203-94 Design Pressure: 2394 Pa (50 psf)
Negative Design Pressure: 2872 Pa (60 psf)
Large Missile Impact Rated
Product Tested By: Architectural Testing Incorporated
Report No: D0002.02-401-18
Expiration Date: January 31, 2018
Administrator's Signature:
NATIONAL ACCREDITATION AND
MANAGEMENT INSTITUTE, INC.
4794 George Washington Memorial Highway
Hayes,VA 23072
Tel: (804) 684-5124
Fax: (804) 684-5122
0���* rr
WINDOWSOLUTIONS �`� ' z
Wit_ 75-MAX.-OVERALL-FLANGE-WIDTH _Newsouth
r V' � � °u��•,,.i
74'=MAXcOVERALLFRAME WIDTH j�*a �� Jj Z o m°
o
4901 Oak Fpir Blvd.,Tampa,FL 33610 ,t fill, n ;z
x Z
« U N•
O
I ` 6 EO
Data
1 v a mda�
E u
9500 Slider XO
IMPACT RATED - HVHZ
5.�b w
Z
w/Flange
¢Od
°d
GENERAL NOTES
E2
1. Thisroduct anchoring drawing has been evaluated and is in compliance with ) a tn
P t ;;3 o aN
the 5th Edition(2014)Florida Building Code(FBC)including the"High Velocity g 1
Hurricane Zone"(HVHZ). See the Certification Agency Certificate for saes, f t,11 / j/ al a a
specifications&ratings. th
m
2. Product anchors shall be as listed and spaced as shown on details.Anchor
embedment to base material shall be beyond wall dressing or stucco.
3. When used in the"HVHZ,this product complies with Section 1626 of the FBC and N
does not require an impact resistant covering. W o
LA
4. For 2x stud framing construction,anchoring of these units shall be the some as
that shown for 2x buck masonry.construction.
Q W
o 5. Site conditions that deviate from the details of this drawing require further 6
engineering analysis by a licensed engineer-or registered architect.
'W
z MAX OVERAll MAX OVERALL MAX MAX. DESIGN PIrESSURE o
z TABLE OF CONTENTS DAY LITE DAy LRE G[ASS °
FLANGE FRAME DIMENSION DIMENSION
SHEEP# DESCRIPTIONDIMENSION DIMENSION.' (ppERAg1E) (FIXED]:: TYPE POS.. NEG Z v
1 Typical elevations,design pressures&general notes a � _ 4A '.2_9/I4 Z
a 2 Vertical&horizontal cross sections 5 0"X?64 0 74 0 X63 0 33.5':X57 31 : 3349'X§8 56 G7 +S0 0 -60.6- ,�,„�. sruE N.T.S.
3 Buck&frame anchoring DWG.B,: JK m
4 Components ote:This product is not approved for use above 30 feet in the"HVHT'. CHK.BY. LFS 3
5 Bill of materials and glazing details BRAwwG No.: a
a
z FL-16842.6 0
9
sH¢r t OF 5
NOTE:Sheet Metal Screws must \\A.
penetrate a min.of 3 threads N, o n
K through at least 2 sheets of metal. _a/
Ps om
d /� * \\\ Z. M
X
o v 2 E �rrnl e d rTit 0 n°mz°_ �N..
O G� °
\ a
ci
GI \ �a �p 5 -CD
Q
D
0
217 / / vZ
Ui
F
2 C
(� Z�
Note: 2 L] 17 SEE NOTE 3 00
1.Lock and keeper located T from (2) Oq = =w
each end of locklmeeting stile. n
2.Metal roller assembly located 2'from 4 HORIZONTAL CROSS SECTION v '
each end of the bottom rail. C'1 5 Z ¢o
70 $ Metal Stud Construction
3.Mti-lift secured to head with
(6)#6x1/2"PPfiSMS. E 3 0
o
0
$ 1-1/4"MIN. N
EMB.(TYP.) 4A m
B Gl 3 v
v. m
3 C C 2 15
F 10 13 o d 18 N
z
7 Gl D m
SEE NOTE 1 11
E! o
14 SEE NOTE 2 � LD
12 16 0
G1 C
a
F o
v
3 D
_ B �w Q
° c 0
a Z
' 6 1 E e. v
3 D ° ° c DATE 2/19/14 0
91-1/4"MIN. z s�E: N.T.S.
3 O O EMB.PP.) f Dwc.BY: JK m
E 1 HORIZONTAL CROSS SECTION r-2 HORIZONTAL CROSS SECTION 3 VERTICAL CROSS SECTION CHK LFS
3 w DRAWING No.:
z" 2 2X Buck Masonry Construction 2 1 X Buck Masonry Construction 2 2X Buck Masonry Constnlction o
FL-16842.6 0
SHEET 2 OF S N(�
V
.............
va
Z,!Q
ZZ,
z
y.. C <r-
. ...........
D>
4" U)
U(TYP.) ITYP o r)m z
m
m.5 c,1 w
o
D TYP-
cz 6
c vi
r FRAME F
oc
2X BUCK 3�
2X SUB D 1 X BUCK
2X
BUCKSUB BUCK
K STEEL STUD
uj
MASONRY TYP.
MASONRY Ln u-
OPENING OPENING
X
W
ilkO
o3
0
2X BUCK ANCHORING FRAME ANCHORING
Z
O
CONCRETE ANCHOR NOTES: o_
1.Concrete anchor locations at the comers may be adjusted to maintain the min. —————
edge distance to mortar joints.c 2.
Concrete anchor locations noted as"MAX.ON CENTER"musf be cdftzfed to z
maintain the min.edge distance to mortarjoInts.additional concrete anchors
may be required to ensure the'MAX.ON CENTER"dimension are not exceeded.
z 3.Concrete anchor table: ——————0 w
A11
;.
N..CIEAMPICE,,Mly.q(ARAN.. z ID
ANCHOR W41"h6i .._MIN :70 MASONRY
TO
...... .......
PJACE
.TYPE :SIZE WE: 2/19/14 z
ANCHOR
........ '....
ITW sCALE: N.T.S.
TAPCON® 1/4' 1-1/4- 2- 4"
DWG.BY: JK
ELCO 1/4' 1-1m 4"
U
LTRACON (r
WOOD SCREW INSTALLATION NOTES: q
1.Maintain a minimum 5/8"edge cflsfcnce,I"end distance,&)"o.c.spacing of a
wood screws to prevent the splitting of mod.
\Clients\New South Windows PERMANENT\Florida Product A rovals\FL-16842\C-Drawin s\FL-16842(2014AFL-16842.1-6.dw 4.6
O
A o_
Z W
6)
v I 3,29"
m
2
T
Q
n
O
O
P
N t„
0 1
0
z
o
m
N
W p ❑
a 5 3
o —1.24' o
J_ m
�i 'voi O I
m
0.26' ❑
O o° N
a
n
m
3
w -T
r� o
N A
"0.46
�—
o I o
7
0.06" ] y
Yl o '`
o 0 � o q
�0.06'
A
y
A
O
7,.29"—
0.94"—►{
o
A O.OT'
OT' F � � o.
O. x' W
ao
� 1.61.42" 2.17'
1.63" 3" �` v'�V��''•..
/ No.43409
Iva
u, PRODUCT: Documents Pnsparad BY.
$ x .+ L ndon F. Schmidt //�•• ORIVI�,''
r N NewSouth P.E. No. 43409 / G�`
I-P — D •' \ 2jllllllllttt
`' y co PART OR ASSEMBLY: G]� BUILDING CONSULTANTS, INC.
N ut 1 6/25 15 UPDATE TO 5TH ED. 2014 FOC Ifs J li P.O. Box 230, Valrtco, FL 33595
IU �114 { NO DATE BY Phone No.: 813.659.9197
REVISIONS COMPONENTS FBPE C.A. No. 9813
Q 2014 R.W.BUILDING CCIN—A—INC.
%AW fill
BILL OF MATERIALS `0�.: /a '
ITEM R DESCIUP170N MATERIAL '`1�
�L p M
B 2X BUCK(SG>=0.55) WOOD =a•� &;Q=z
C 114"MAX.SHIM SPACE ;an. z
D 114'X 2-3/4"PFH ELCO OR RW CONCRETE SCREW STEEL a 8 0
MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI �'� '•-•....-• 't�4y.� a 'm
E 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE /�//y/LL*pv
1v �����\ i o'm 6
F #10 X 7'PPH SMS(1-1/4"MIN.EMBEDMENT) STEEL c°)ccv Z
J STEEL STUD Min.Thk.033" (ASTM A653 GRADE 33 Fy=33 ksi min.,Fu=45 ksi min.) STEEL �1 m 9 0 xz a
K #10 PPH SELF-DRILLING SMS STEEL \ °a r o m c w
1 EXTRUDED VINYL FRAME(439)" RIGID PVC a` n a r m
2 EXTRUDED VINYL GLAZING BEAD(736A)' RIGID PVC a m n a
3 EXTRUDED VINYL GLAZING BEAD(425A)' RIGID PVC E az
4 BOTTOM RAIL(4248)' RIGID PVC
G Jd
5 TOP RAIL(478)• RIGID PVC
6 MEETING STILE(477)• RIGID PVC
7 LOCK STILE(476)` RIGID PVC
8 HANDLE STILE(4756)' RIGID PVC
9 MEETING STILE REINFORCEMENT 6063-T5 ALUM ¢�
N � wo
a 10 LOCK STILE REINFORCEMENT 6063-TS ALUM
o �
11 SASH LOCK w
12 KEEPER - z
$ 13 HANDLE STILE REINFORCEMENT 6063-T5 ALUM N 'U
a o
m
tk 14 ROLLER(TRUTH#2433-1000) - o
15 SILL RISER 6063 TS ALUM 0 a
16 ROLLER TRACK 6063-T5 ALUM a a
17 AMI-LIFT ALUMINUM 6063-T5 ALUM 5/8"
18 BOTTOM RAIL REINFORCEMENT 6063-TS ALUM GLASS BITE 7/9'0.A.GLASS THK. m
20 WEATHERSTRIP(.187'X.29(Y") GLAZING SEALANT
m
o 'THE APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONS FOR WINDOWS ARE TO BE PRODUCED BY (SIKAFLEX-552) 1/8"ANNEALED GLASS
EXTRUDERS LICENSEES IN"HAMA CERTIFICATION PROGRAMS FOR RIGID PVC EXTRUSIONS". o
n
0.090 SAFLEX®PVB INTERLAYER w o_
LL x 0
CD
1/8"ANNEALED GLASS '
a O AIR SPACE
n w
O 1/8'ANNEALED GLASS a o
METAL REINFORCED BUTYL zD �
v n
- W z<
N Q J
G� GLAZING DETAIL z D
v
GATE 2/19/14
z
0
sCa,r• N.T.S.
� 9
3
DWG.BY: ,JI( m
CHK.BY: LFS 3
DRAWING NO.:
a
2 F1_-16842.6' o
N
SHEET S Of S
v
s�