HomeMy WebLinkAboutProduct Approval (2) 11/6/2015 Florida Building Code Online
ren [7
+.. ze. l. .� -i ggy�
'Ic S
—
lol,16 Devrr eivBCIS Home Log In User Registration Hot Topics Submit Surcharge i Stats&Facts Publications FBC Staff BCIS Site Map Links Search
Busines
@USER:Product Approval
Professi real Public User
Regulation
Product Approval Menu>Application Detail
llillilliFtm 16
ie
Application Type Revision
Code Version 2014
Application Status Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer NewSouth Window Solutions
Address/Phone/Email 4901 oak fair blvd
tampa, FL 33610
(513) 284-0129
danochstein@newsouthwindow.com
Authorized Signature Vivian Wright
rickw@rwbldgconsultants.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Windows
Subcategory ' Horizontal Slide„ry
Compliance Method Certification Mark or Listing
Certification Agency National Accreditation&Management Institute
Validated By Ryan J. King; P.E.
Validation Checklist- Hardcopy Received
Referenced Standard and Year(of Standard) Standard Year
AAMA/W D MA/CSA101/I.S.2/A440 2008
AAMA/W DMA/CSA101/I.S.2/A440 2005
ASTM E1886 2005
ASTM E1996 2006
ASTM E1996 2005
TAS 201, 202, 203 1994
Equivalence of Product Standards
Certified By
Product Approval Method Method 1 Option A
https://floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsf°/p2fLKgxApZZQMacKkAQnfZOIIIIoRVQrXwp/o3d%3d 1/6
11/6/2015 Florida Building Code Online
Date Submitted 07/02/2015 r
Date Validated 08/06/2015 --
Date Pending FBC Approval
Date Approved 08/11/2015
Summary of Products
Go to Page Page 1/ 2
FL# Model,Number or Name Description
16842.1 a. 9500 Slider XO Extruded Vinyl "Non-Impact":Horizorital.Sliding Windo
utilizing a Nail Fin Installation (XO or OX configurations)
_.. .......
Limits of Use Certification Agency Certificate t.
Approved for use in HVHZ: No FL16842 R2 C CAC NAMI Cert for 16842.1 (60 x 60).pdf i
Approved for use outside HVHZ:Yes FL16842 R2 C CAC NAMI Cert for 16842.1 (74 x 62)..Ddf
Impact Resistant: No FL16842 R2 C CAC NAMI Cert for 16842.1 (74 x 62).Ddf
Design Pressure: N/A (Quality Assurance Contract Expiration Date
Other: See INST 16842.1 for Design Pressure Ratings, any 05/31/2017
additional use limitations, installation instructions and product Installation Instructions
particulars. FL16842 R2 II Inst 16842.1.pdf
Verified By: Lyndon F. Schmidt, P.E. 43409 j
Created by Independent Third Party: Yes
Evaluation Reports
Created
y AE Evals e tThir 1.ort
Created by Independent Third Party: Yes
16842.2 i b. 9500 Slider XO Extruded Vinyl "Non-Impact" Horizontal Sliding Window with
Flange Installation (XO or OX configurations) j
.._.._...........__ ._._._..__._._.._......_..__.._...:— --- ._.............–_..._...__....._.............._...........__... ............_........-------.._......._......._................... .__
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL16842 R2 C CAC NAMI Cert for 16842.2 (60 x 60).Ddf
Approved for use outside HVHZ: Yes FL16842 R2 C CAC NAMI Cert for 16842.2(74 x 62)..pdf
Impact Resistant: No FL16842 R2 C CAC NAMI Cert for 16842.2 (74 x 62).Ddf
Design Pressure: N/A Quality Assurance Contract Expiration Date
Other: See INST 16842.2 for Design Pressure Ratings, any 05/31/2017
additional use limitations, installation instructions and product Installation Instructions i
particulars. 1116842 R2 II Inst 16842.2.Ddf
Verified By: Lyndon F. Schmidt, P.E. 43409
Created by Independent Third Party: Yes
Evaluation Reports
FL16842 R2 AE Evals 16842.2.pdf
Created by Independent Third Party: Yes
16842.3 i c. 9500 Slider XO Extruded Vinyl "Impact" Horizontal Sliding Window utilizing a
Nail Fin Installation (XO or OX configurations)
Limits of Use Certification Agency Certificate –�
Approved for use in HVHZ: No FL16842 R2 C CAC NAMI Cert for 16842.3 (74 x 63)..odf
Approved for use outside HVHZ:Yes FL16842 R2 C CAC NAMI Cert for 16842.3 (74 x 63).Ddf
Impact Resistant: Yes Quality Assurance Contract Expiration Date E
Design Pressure: N/A 09/30/2017
Other: See INST 16842.3 for Design Pressure Ratings, any Installation Instructions
additional use !imitations, installation instructions and product FL16842 R2 II Inst 16842.3.Ddf
particulars. Verified By: Lyndon F. Schmidt, P.E. 43409
Created by Independent Third Party: Yes
Evaluation Reports
FL16842 R2 AE Evals 16842.3.pdf
Created by Independent Third Party: Yes
16842.4 d. 9500 Slider XO II Extruded Vinyl "Impact" Horizontal Sliding Window with !
j I Flange Installation (XO or OX configurations)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL16842 R2 C CAC NAMI Cert for 16842.4(74 x 63)..)d
Approved for use outside HVHZ:Yes FL16842 R2 C CAC NAMI Cert for 16842.4(74 x 63).Ddf
Impact Resistant: Yes Quality Assurance Contract Expiration Date
Design Pressure: N/A 09/30/2017
Other: See INST 16842.4 for Design Pressure Ratings, any Installation Instructions
additional use limitations, installation instructions and product FL16842 R2 II Inst 16842.4.Ddf
particulars. Verified By: Lyndon F. Schmidt, P.E. 43409
Created by Independent Third Party: Yes
Evaluation Reports
FL16842 R2 AE Evals 16842.4.pdf
Created by Independent Third Party: Yes
16842.5 j e. 9500 Slider XO- Impact Rated- Extruded Vinyl "Impact" Horizontal Sliding Window utilizing a I
' HVHZ Nail Fin Installation (XO or OX configurations)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes FL16842 R2 C CAC NAMI Cert for 16842.5 (74 x 63).Ddf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
hUps://floridabuilding.org/pr/pr_app_dd.aspx?param=wGEVXQwtDgtmmTSTNdVPsf%2fLKgxApZZQMacKkAQnfZol ll loRVQrXw%3d%3d 2/6
11/6/2015 Florida Building Code Online
Impact Resistant: Yes 01/30/2018 I
= Design Pressure: N/A Installation Instructions
Other: See INST 16842.5 for Design Pressure Ratings, any FL16842 R2 II Inst 16842.5.()df
additional use limitations, installation Instructions and productVerified By: Lyndon F. Schmidt, P.E. 43409
particulars. Created by Independent Third Party: Yes
Evaluation Reports
FL16842 R2 AE Evals 16842.5.pdf
i
Created by Independent Third Party: Yes
16842.6f. 9500 Slider XO- Impact Rated -i-Extruded Vinyl "Impact" Horizontal Sliding Window with f
HVHZ Flange Installation (XO or OX configurations)
zL'i�mits o e N ,� E� z "raj Ge��fi�cation Agency Certificate
pproved for use m HV Z fe y��� � c�iFL�1r684a R2�C CAC '99MI C�`e�rt o 6842^.6 (74 x 63).pdf
Approved forrtuse3 ourside¢HVcHMfZ Quality AssurarrcefContrac�Exp�yrak D xa e
.f r nk « q-. r+" `�/-',•
:I�npact,Resistant Yesr ?`
'GW$+C, -sqi S uc�t'?§c..� }". `1 § .P r� , q
Desi nfPressure. /!k f y I Installation InsErui tton5
f _ O,her'See INST�1'6842r6-fdr Des�gn�IPre`ssure'Ratirigs zany 'FL'1842�2 II`)nstd§8426ptlf I
ad�t tional useelimit�tions n
�installation� structiorLs and prod4�CVeriied<Sy jy#ndo � ��5ci�it, PSE434 9,
1pertic lars: � a ' ,'fir r r t s CP at;sdi�b Intle endent Third�Par Yes 1FL16842 R2''A`E 19 12.
`, reatedrby Ir2depend nt ThirtlpParty';.iY�e
C ..s
16842.7 g. 9500-3 Slider;O&_' Extruded Vinyl "Non-Impact" Horizontal Sliding Window
utilizing a Nail Fin Installation (XOX, configuration)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No S 16842 R2 C CAC NAMI Cert for 16842.7 (111 x 63)pdf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: No 01/31/2018
Design Pressure: N/A Installation Instructions
Other: See INST 16842.7 for Design Pressure-Ratings, any i FL16842 R2 II Inst 16842.7.pdf
additional use limitations, installation instructions and product Verified By: Lyndon F. Schmidt, P.E. 43409
particulars. Created by Independent Third Party: Yes
Evaluation Reports
FL16842 R2 AE Evals 16842.7.Ddf I
Created by Independent Third Party: Yes -
16842.8 h. 9500-3 Slider XOX (Extruded Vinyl "Non-Impact" Horizontal Sliding Window with
j Flange Installation (XOX, configuration) I
---------------- .._ r _. _-..... - - - ..._----- _. --.._..---— -...._..— ---------------- --------
Limits of UseCertification Agency Certificate
Approved for use in HVHZ: No I FL16842 R2 C CAC NAMI Cert for 16842.8 (111 x 63).odf
Approved for use outside HVHZ:Yes f Quality Assurance Contract Expiration Date {
Impact Resistant: No 4 01/31/2018
Design Pressure: N/A l Installation Instructions
Other: See INST 16842.8 for Design Pressure Ratings, any !I FL16842 R2 II Inst 16842.8.pdf
additional use limitations, installation instructions and product' Verified By: Lyndon F. Schmidt, P.E. 43409
particulars. Created by Independent Third Party: Yes
Evaluation Reports j
FL16842 R2 AE Evals 16842.8.Ddf
Created by Independent Third Party: Yes
16842.9 i. 9500-3 Slider XOX Extruded Vinyl "Impact" Horizontal Sliding Window utilizing a
Nail Fin Installation (XOX, configuration)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: NoFL16842 R2 C CAC NAMI Cert for 16842 9 (111 x 63) pdf
Approved for use outside HVHZ:Yes f Quality Assurance Contract Expiration Date
Impact Resistant: Yes i 06/30/2018
Design Pressure: N/A Installation Instructions
Other: See INST 16842.9 for Design Pressure Ratings, any FL16842 R2 II Inst 16842.9.pdf
additional use limitations, installation instructions and product Verified By: Lyndon F. Schmidt, P.E. 43409
particulars. I Created by Independent Third Party: Yes
Evaluation Reports
FL16842 R2 AE Evals 16842.9.Ddf
Created by Independent Third Party: Yes
16842.10j. 9500-3 Slider XOX Extruded Vinyl "Impact" Horizontal Sliding Window with I
Flange Installation (XOX, configuration)
.-..-..............----�._....-_............
--.__ _._ ._......_..... -- ............_........--..._.. ...................... ._..._ -.___......................-_..�-. ----
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL16842 R2 C CAC NAMI Cert for 16842 10(111 x 63)_12df
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 06/30/2018 j
Design Pressure: N/A Installation Instructions
Other: See INST 16842.10 for Design Pressure Ratings, any FL16842 R2 II Inst 16842.10.pdf
additional use limitations, installation instructions and product I Verified By: Lyndon F. Schmidt, P.E. 43409 I
particulars. I Created by Independent Third Party: Yes
Evaluation Reports
FL16842 R2 AE Evals 16842.10.Ddf
Created by Independent Third Party: Yes
_____....
...._
https://fioridabuilding.org/pr/pr_app dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsf/o2fLKgxApZZQMacKkAQnfZ011lloRVQrXw%3d%3d 3/6
11/6/2015 Florida Building Code Online
16842.11 I k. 9500-3 Slider XOX- Impact Extruded Vinyl "Impact" Horizontal Sliding Window utilizing a'
Rated - HVHZ Nail Fin Installation(XOX, configuration) i
Limits of Use IiI Certification Agency Certificate
Approved for use in HVHZ:Yes k FL16842 R2 C CAC NAMI Cert for 16842.11 (111 x 63),osif
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 06/30/2018
Design Pressure: N/A Installation Instructions
Other: See INST 16842.11 for Design Pressure Ratings, any FL16842 R2 II Inst 16842.11.odf i
additional use limitations, installation instructions and product Verified By: Lyndon F. Schmidt, P.E. 43409 i
particulars. Created by Independent Third Party: Yes
'Evaluation Reports
FL16842 R2 AE Evals 16842.11.0f
Created by Independent Third Party: Yes f
16842.12 11. 9500-3 Slider XOX- Impact Rated Extruded Vinyl "Impact" Horizontal Sliding Window with
HVHZ Flange Installation (XOX, configuration)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes ! FL16842 R2 C CAC NAMI Cert for 16842.12 (111 x 63).)df 1
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant:Yes 06/30/2018
Design Pressure: N/A Installation Instructions
Other: See INST 16842.12 for Design Pressure Ratings, any FL16842 R2 II Inst 16842.12.12df
additional use limitations, installation instructions and product Verified By: Lyndon F. Schmidt, P.E. 43409
particulars. Created by Independent Third Party: Yes
Evaluation Reports
FL16842 R2 AE Evals 16842.12.pdf i
Created by Independent Third Party: Yes
_.................._ _..........-.......-----................_.._-_. -
16842.13 m. DuraGard Slider XX Extruded Vinyl "Non-Impact" Horizontal Sliding Window j
utilizing a Nail Fin Installation (XX, configuration) I
Limits of Use !Certification Agency Certificate
Approved for use in HVHZ: No f FL16842 R2 C CAC NAMI Cert for 16842.13 (72 x 56).)d i
Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date
Impact Resistant: No 12/31/2015
Design Pressure: N/A Installation Instructions
Other: See INST 16842.13 for Design Pressure Ratings, any FL16842 R2 II Inst 16842.13.odf
additional use limitations, installation instructions and product Verified By: Lyndon F. Schmidt, P.E. 43409
particulars. Created by Independent Third Party: Yes j
Evaluation Reports f
FL16842 R2 AE Evals 16842.13.pdf I
Created by Independent Third Party: Yes
_.._.......... _.—.._...._. ..._—_— ._......_..__...----_._.._.....-........... _._._-..................._........_..--- _..._._.._...._..-....-----._._._--._..__._........_ .__.............__. E
16842.14 ! n. DuraGard Slider XX Extruded Vinyl "Non-Impact" Horizontal Sliding Window (XX,
configuration)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL16842 R2 C CAC NAMI Cert for 16842.14 (72 x 56).odf
Approved for use outside HVHZ:Yes FL16842 R2 C CAC NAMI Cert for 16842.14 (72 x 65).odf
Impact Resistant: No Quality Assurance Contract Expiration Date
Design Pressure: N/A 12/31/2015
Other: See INST 16842.14 for Design Pressure Ratings, any Installation Instructions
additional use limitations, installation instructions and product FL16842 R2 II Inst 16842.14.odf
particulars. Verified_By: Lyndon F. Schmidt, P.E. 43409 I
Created by Independent Third Party: Yes !
Evaluation Reports
FL16842 R2 AE Evals 16842.14.pdf
Created by Independent Third Party: Yes J
....._....-.._. ........—_..._......_...--.--.........._.....----..__..._._.__.-._...---...__.._.-_... ----... -_...... -. __......................--
i
16842.15 i o. DuraGard - 3 Slider XOX II Extruded Vinyl "Non-Impact" Horizontal Sliding Window
I i utilizing a Nail Fin Installation (XOX, configuration)
Limits of Use Certification Agency Certificate j
Approved for use in HVHZ: No FL16842 R2 C CAC NAMI Cert for 16842.15(112 x 63).odf
Approved for use outside HVHZ:Yes E Quality Assurance Contract Expiration Date
Impact Resistant: No 03/31/2019
Design Pressure: N/A !Installation Instructions I
Other: See INST 16842.15 for Design Pressure Ratings, any FL16842 R2 II Inst 16842.15.odf
additional use limitations, installation instructions and product Verified By: Lyndon F. Schmidt, P.E. 43409
particulars. Created by Independent Third Party: Yes
Evaluation Reports
FL16842 R2 AE Evals 16842.15.odf
Created by Independent Third Party: Yes
_......................_....._—_............-..--......._......_..._._..__......_............_.............._...._..._....._..............._............_.........._._.._......................._.,..._...._..._................._.,__.__._..._..........................__..........--.._._.
16842.16 p. DuraGard - 3 Slider XOX Extruded Vinyl "Non-Impact" Horizontal Sliding Window with
i Flange Installation (XOX, configuration)
..........--- — .................._._- __-..........--.......-_. - _._ ._.._-._..._._._..........._._...__......... —__....__.. - .-.._.. _..__...._............._._........._.....................................................--....__�
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL16842 R2 C CAC NAMI Cert for 16842.16(112 x 63).odf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date j
Impact Resistant: No 04/30/2016
Design Pressure: N/A Installation Instructions j
https://floridabuilding.org/pr/pr_app d.aspx?param=wGEVXQwtDgtmmTSTNdVPsf%2fLKgxApZZQMacKkAQnfZ011lloRVQrXw%3d%3d 4/6
11/6/2015 Florida Building Code Online
i Other: See INST 16842.16 for Design Pressure Ratings,'any FL16842 R2 II Inst 16842 16 pdf
' additional use limitations, installation instructions and product Verified By: Lyndon F. Schmidt, P.E. 43409
particulars. Created by Independent Third Party: Yes
Evaluation Reports
FL16842 R2 AE Evals 16842.16.pdf
Created by Independent Third Party: Yes
_.........._.._......__......_ ._.— —- ....._._......__— ._...... -.._..._.—._---- -- _ ----- ....-- —- — -- ---- _... -..........�
16842.17 q. Sashlite Slider XX Extruded Vinyl "Non-Impact' Horizontal Sliding Window I
utilizing a Nail Fin Installation (XX, configuration)
__..._..____- _._.-._..._._.__---_..I
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL16842 R2 C CAC NAMI Cert for 16842.17(72 x 60).pdf
Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date f
Impact Resistant: No 03/31/2019
Design Pressure: N/A Installation Instructions
Other: See INST 16842.17 for Design Pressure Ratings, any FL16842 R2 II Inst 16842.17.odf
additional use limitations, Installation instructions and product Verified By: Lyndon F. Schmidt, P.E. 43409
particulars. Created by Independent Third Party: Yes
Evaluation Reports i
FL16842 R2 AE Evals 16842.17.Ddf
Created by Independent Third Party: Yes
___...__......_..___—..._............_......._._....
—.__..__.._.._.__.._...----_._-....._._....—._.__...—.._..__..----..__.._._ --___—
_-----_.
16842.18 r. Sashlite Slider XX Extruded Vinyl "Non-Impact' Horizontal Sliding Window (XX,
- - -----.._........---- configuration)-- -...—_._
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No C FL16842 R2 C CAC NAMI Cert for 16842.18(72 x 60).Odf
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date
Impact Resistant: No 03/31/2019 i
Design Pressure: N/A I Installation Instructions
Other: See INST 16842.18 for Design Pressure Ratings, any FL16842 R2 II Inst 16842.18.Ddf
additional use limitations, installation instructions and product Verified By: Lyndon F. Schmidt, P.E. 43409
particulars. Created by Independent Third Party: Yes
Evaluation Reports
FL16842 R2 AE Evals 16842.18.pdf
Created by Independent Third Party: Yes
......_.._.........—----—._._______.._.._.. _____ — .��_ ._......
_.._._____.____..—._.__— ----.._._-
16842.19 — s. Sashlite - 3 Slider XOX Extruded Vinyl "Non-Impact' Horizontal Sliding Window
I utilizing a Nail Fin Installation (XOX, configuration)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ: No FL16842 R2 C CAC NAMI Cert for 16842.19 (112 x 60).pdf j
Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date j
Impact Resistant: No • 03/31/2019
Design Pressure: N/A Installation Instructions -
Other: See INST 16842.19 for Design Pressure Ratings, any FL16842 R2 II Inst 16842.19.pdf
additional use limitations, installation instructions and product Verified By: Lyndon F. Schmidt, P.E. 43409
particulars. Created by Independent Third Party: Yes j
Evaluation Reports
{ FL16842 R2 AE Evals 16842.19.Ddf
Created by Independent Third Party: Yes
_.......-...._ —.—_... .--_._..-. --.............._.........._ ..........._............. —----._....__._._...._.._._._._._—
16842.20 ;t. Sashlite - 3 Slider XOX _ i Extruded Vinyl "Non-Impact' Horizontal Sliding Window (XOX,
configuration)
Limits of Use Certification Agency Certificate i
Approved for use in HVHZ: No FL16842 R2 C CAC NAMI Cert for 16842.20 (112 x 60).Ddf
Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date
Impact Resistant: No 03/31/2019
Design Pressure: N/A Installation Instructions f
Other: See INST 16842.20 for Design Pressure Ratings, any FL16842 R2 II Inst 16842.20.pdf
additional use limitations, installation instructions and product Verified By: Lyndon F. Schmidt, P.E. 43409
particulars. Created by Independent Third Party: Yes
Evaluation Reports
FL16842 R2 AE Evals 16842.20.pdf i
Created by Independent Third Party: Yes
Go to Page Pagel/ 2
pack Yd,txt
Contact Us:: 1940 North Monroe Street,Tallahassee Fl_32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida. :: Privacy Statement::Accessibility Statement:: Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,d°not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.`Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter
455,F.S.,please click here.
Product Approval Accepts:
https:/lfloridabuilding.org/pr/pr_app dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsf°/g2fLKgxApZZQMacKkAQnfZ01111oRVQrXw°/pad°/g3d 516
11/6/2015 Florida Building Code Online
n _
RAIIII
eCRa:k r
socur]ty\tvluF tcs'
https://floridabui lding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtm mTSTNdVPsN/`2fLKgxApZZQM acKkAQnfZ0I II IoRVQrXw%3d%3d 6/6
NOTICE OF PRODUCT CERTIFICATION
CERTIFICATION NO: NI011847-R2
DATE: 02/07/2014
CERTIFICATION PROGRAM: Structural
COMPANY: NewSouth
� r � �` CODE: 2013-1
V NIT
REVISION DATE: 08/03/2015
To verify that the"Notice of Product Certification"is valid,please visit www.NAMICertification.com to assure that the
product is active and currently listed.This certification represents product conformity to the applicable specification and
that certification criteria has been satisfied. A NAMI approved certification.label must be applied to the product to claim
certification status. Please review and advise NAMI if any corrections are required to this document.
COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION
NewSouth Window Manufacturing,LLC Series "9500"
4901 Oak Fair Boulevard Horizontal Roller
Tampa, FL 33610 Vinyl Horizontal Sliding Window
Configuration: XO
Glazing: IG-1/8"Annealed Glass/Laminate-1/8"
Annealed Glass/0.090"PVB Interlayer/1/8"Annealed
Glass
Frame: W-1879mm(74.00") H-1600mm(63.00")
Vent: W-934nv-n(36.81") H-1541mm(60.68")
DLO: W-844mm(33.25") H-1487mm(58.56")
SPECIFICATION PRODUCT RATING
TAS 201/202/203-94 Design Pressure: 23.94 Pa (50 psf)
Negative Design Pressure: 2872 Pa (60 psf)
Large Missile Impact Rated
Product Tested By: Architectural Testing Incorporated
Report No: D0002.02-401-18
Expiration Date: January 31, 2018
Administrator's Signature:
NATIONAL ACCREDITATION AND
:MANAGEMENT INSTITUTE, INC.
4794 George Washington Memorial Highway
Hayes,VA 23072
Tel: (804) 684-5124
Fax: (804) 684-5122
A,Newsouth
:::
Z :0z m
\. ` o m
BVII`RDO � SOLUTIONS pY,f 75'MAX.OVERALLFLANGEWIDhI %v''•,
74"M .OVERALL FRAME WIDTH
o n m z0
AX
4901 Oak Fair`vd.,Tampa,FL 33610 ..
� x
W' to 9m�
°
OIL
9500 Slider X®
IMPACT RATED - HVHZ �((
1� , • w � Z
W Flange ? Z
g GENERAL NOTESste
N JW
1. This product anchoring drawing has been evaluated and is in compliance with
the 5th Edition(2014)Florida Building Code(FBC)including the"High Velocity o a
Hurricane Zone"(HVHZ).See the Certification Agency Certificate for saes, ''fi1:, j/ it a
specifications&ratings.
2. Product anchors shall be as listed and spaced as shown on details.Anchor
o embedment to base material shall be beyond wall dressing or stucco. "•';, c
3. When used in the"HVHZ,this product complies with Section 1626 of the FBC and N
does not require an impact resistant covering. W o
4. For 2x stud framing construction,anchoring of these units shall be the some as
a that shown for 2x buck masonry construction.
0 5. Site conditions that deviate from the details of this drawing require furtherA. s F/ Z
engineering analysis by a licensed engineer or registered architect. -
w
LL DESIGN PRESSURE a
z MAX OVERAll MAX OVERACT MAX MAX
Z TABLE OF CONTENTS ndv LrrE Dar LRE Glass m
FLANGE FRAME n
W SHEET# DESCRIPTION DIMENSION DIMENSION Xypp
DIMENSION L1IMENSION (OPERABLE) (FIXED);;: POS: . ....NEG..
1 Typical elevations,design pressures&general notes ""'" DATE: 2119114
2 Vertical&horizontal cross sections 75.9'X 64.0" 74.0"X 63.0" 33S'X 57.31" 33.25"X 58.56" Gl +50.0 -60.0 s— N.T.S.
3 3 Buck&frame anchoring DWG.D.: JK m
4 Components Note:This product is not approved for use above 30 feet in the"HVHZ'. a«.er: LFS 3
5 Bill of materials and glazing details DnawiNc No.:
Z FL-16842.6
0
sHEEr 1 OF S N
.V
a NOTE:Sheet Metal Screws must
K penetrate a min.of 3 threads O:'
through at least 2 sheets of metal. M J=i
C 1 zcd
:W• v
1 v v E n �����/*Ps �� o M m z
2 a e ° m oN0
p
e Z m U
a e S O C W
Gil a
D s4
2 / / ' v Z
B S a
2 C
3 n oZ
Note. 2 L7 17 SEE NOTE 3 No
1.Lock and keeper located Tfrom2 p ocP,
aeach end of locklmeeting stile. Q z�
2.Metal roller assembly located 7'from r4 HORIZONTAL CROSS SECTION GI °} M
each end of the bottom rail. 2 Metal Stud Construction $ Z o
3.Anti-lift secured to head with a
(6)#6 x 1/2"PPH SMS. E 30
o �
0
1-1/4"MIN. a
EMB.(TYP.) A 4 m
B �°
GI 3 U
3 CC 2 15 UT
g a o 8
F 10 Gil 13 18
,` D o d N N
SEE NOTE 1 7
I� o Z
LD
lLl 0 14 SEE NOTE 2 _
12
W
1 16 0
a < G1 C
F z
o v
0 3 D
❑ B Na
Zv
F5 <
6 1 E Z a
c. o
9 D a c 0.47E 2/19/14 0
I-114"MIN. N.T.S.
3 O 2 EMB.(TYP.) owc.ev: JK M
E 1 HORIZONTAL CROSS SECTION 2 HORIZONTAL CROSS SECTION r3 VERTICAL CROSS SEC17ON CHK BY: LFS rc
2 2X Buck Masonry Construction 2 I X Buck Masonry Construction —u oRnmHc Ho.:
Z 2 2X Buck Masonry Construction FL-16842.6
0
N
SHEET 2 OF S
v
6 q3
r //tit Iltt c� oro z
�P) "YP•) / t m o
4
17'(1YP), Lt z o z o
a
m
co C 0.
J O0.
l./ 4 \ s to 7OLm
TYP. Oz
C
�• ;�„f � FRAMEf 2X BUCK
y, .� �., 2X SUB D 1X BUCK
r S _ la
BUCK
BUCKK STEEL STUD ksi w
,MASONRY TYP. 'o z
N,06PENING ::,ti e. MASONRY 3
OPENING z m Y v
t 4 w
AQ
O.C; ;
�f =I
,v_ r I ,a� o
;9 a 1% }5 t�•� 1 1 I o it
4i d,t` t-� a � •S f r U m
C\ o
2XBUCKANCHORING ! �.. "ti� FRAME ANCHORING in
;e o
- o
E CONCRETE ANCHOR NOTES: mIx
j ri
1.Concrete anchor locations at the corners may be adjusted to maintain the min. ?
edge distance to madarloints. 'n a
2.Concrete.anchor locations noted os"MAX.ONCENTER'mustbeadjusted to \w z
if LL maintain the min.edge distance to mortorjolnfs additional concrete anchors N
W may be required to ensure the'MAX.ON CENTER"dimension are not exceeded. m m
3 Concrete anchor fable _ o
ANCHOR ANCHOR MIN
MIN:CLEARANCE MfN'CLEARANCE Z a
- TO:MASONRY,:: TO ADJACENT.,`.. a
TYRE SIZE .EMBED-M, s.EDGE. .:ANCNOR <: are 219/74 z
0
SCALE: N.T.S.
ITVY ® 1/4" 1-1/4' 2• 4" d
TAPCON DWG.BY: JK m
ELCO ® 1/4' 1-1/4" 1. 4" CHK.BY: LFS 3
UITRACON /
DRAWING NO.:
WOOD SCREW INSTALLA77ON NOTES: a
1.Maintain a minimum 5"8 edge distance,1'end distance,&r o.c.spacing of FL—7 6842.6 0
F
wood screws to prevent the splitting of wood. SHEET 3 o 5 N
\Clients\New South Windows PERMANENT\Florida Product A rovalAFL-16842\C-8rawin s\FL46842(2014)\FL-16842.1-6.dw 4.6
.O
m O
� w ,
b.
y 3,29"
m
T
a
r)
n
0
P
N
O
O
0
T
O
m
Gt N
a -+•-1.24"—� E o m o
Fn °! "� A o
O
N
�11 O I I N V
'0.26 �l
o O
a b
N
n
ro 0Tsi!,46'
0.21"
c)m9Zzp0 —.A)- a n uN'
--1
to
r -
z ans to 0 Qo
6"• Q �0.0fi
�!
A m
� f
0.94"
—(0.94 �
0.07
or
-r 0,07' y S 0 w
rn a
Cao o'� p�
1.42
No.43409
PRODUCT, Occumonte Prepared 9y'�
Y N NewSouth Lyndon F, Schmidt ��i •• ORIO�.••`•\���
�{, c P.E. No. 43449 Ss•••••••••• G��
!!l7111111�t
PART OR ASSEMBLY: GD BUILDING CONSULTANTS, {NC.
N -TI fi in~a
9WRNI—SICONS
2014 FBC LFS aJ l,�1�j
to BY YU P.O. Box 2381 Valric.659.9, 7 33595
Phone No.: 813.859.819?
COMPONENTS .FBPE C.A. No. 9873
2C I4 R.W.9UILDIMD CpN9ULigNTG INC.
.............
BILL OF MATERIALS
REM R DESCRIPTION
MATERIAL ����,.' '•
B 2X BUCK(SG>=0.55) WOOD =� g� ° ,=z M
"� o:
C 1/4"MAX.SHIM SPACE z° A.0'd W
D 114'X 2-3/4"PFH ELCO OR 17W CONCRETE SCREW STEEL �g��?
E OOR HOLLOW BLOCK CO ORMINGOTO�MIC O �TT
NCRETE NG TO ACI CONCRETE ''''i7 �*"
� 11 ``yam o Z
F #10 X 7'PPH SMS(1-114-MIN.EMBEDMENT) STEEL v n-.
J STEEL STUD Min.Thk.033" (ASTM A653 GRADE 33 Fy=33 ksi min.,Fu=45 ksi min.) STEEL a a z o z
K #10 PPH SELF-DRILLING SMS STEEL \ a t om w
1 EXTRUDED VINYL FRAME(439)` RIGID PVC a D a D a
N A a ma
a�a:
�
2 EXTRUDED VINYL GLAZING BEAD(736A)` RIGID PVC
3 EXTRUDED VINYL GLAZING BEAD(425A) E `z
( ) RIGID PVC � a
4 BOTTOM RAIL(424B)` RIGID PVC S J,a
5 TOP RAIL(478)` RIGID PVC
6 MEETING STILE(477)` RIGID PVC
7 LOCK STILE(476)' RIGID PVC
8 HANDLE STILE(475B)` RIGID PVC �a
9 MEETING STILE REINFORCEMENT 6063-T5 ALUM t wo
10 LOCK STILE REINFORCEMENT 6063-T5 ALUM
11 SASH LOCKz
a
12 KEEPER - z" N �
13 HANDLE STILE REINFORCEMENT 6063-T5 ALUM a mo
14 ROLLER(TRUTH#24331000) - �I o a
15 SILL RISER 6063-T5 ALUM $ 1
16ROLLER TRACK 6063-T5 ALUM a a
17 ANTI-LIFT ALUMINUM 6063-T5 ALUM 5/8"
18 BOTTOM RAIL REINFORCEMENT 6063-T5 ALUM GLASS BITE 7/Ir OA.GLASS THK. m
20 WEATHERSTRIP(.187'X.299-1 GLAZING SEALANT m
`THE APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONS FOR WINDOWS ARE TO BE PRODUCED BY (SIKAFLEX-552) `
EXTRUDERS LICENSEES IN"AAMA CERTIFICATION PROGRAMS FOR RIGID PVC EXTRUSIONS". 1/8"ANNEALED GLASS a
o
0.090 SARHO PVB INTERLAYER w o
z m
a
o 1/S ANNEALED GLASS
a AIR SPACE
w
1/9'ANNEALED GLASS a
0
METAL REINFORCED BUTYL
a n f
W S
h H j
z m
Gll GLAZING DETAIL _p 0
Z
DATE: 2/19/14 m
z
0
SCALE N.T.S.
9
3
DWG.BY:
aHk er. LFS 3
DRAWING NO.: O
'z FL-16842.6 o
S
SHEET OF S O
V
Integrated Office Suite e-Tempest.com ... Page I ,of 1
sf ,
r File Setup Welcome:Bennis Close
File File: File: File: File: File: File: File: File: File:
Manager [1069] (DELEON] [ANDERSEN] [NOVA] [NOVA] [1071] [LEON,MARCELLO] [LEON,MARCELLO] [SMITH,S
Floor Plans
CLARK,JOHN&NANCY
e-Tempest ID:I CLARK,JOHN&NANCY
General Information [1m m
(23 Openings) Floor Plans Drawings New Floating Text NeW..; Print
__
Page# Description Reference
Attachments ka 1
Site Plan Number Text Print Sidebar ❑O
Notice of Commencement ---- No Floating Text Print Drawings
Y St.Lucie County
Permit v v
X St.Lucie County
Drawings Print sizes on: sidebar v Sidebar Text: Devlce(opemllq cess.)! Page:prev Lt]2
X Floor Plan Opening Drawn Number
-- # Width Height Device Sidebar Note Drawing Note:Wr - opening Position on
Description Style Drawing
14 =w�II�DLI Ighlsl beal rettanale frormal 14
Y 15 _I O EEK=guesl Asa 1s ^
�� 16 Dl] 3B Ight sl 9uesths rectangle normal 16
y. 17 =� 39 Ighl d guest hs O�� er ctarple (rormal 17
DEI39 Ighl sl 1a
Y DKI L��"` � 36 Ighl sl guest bath 1 � [eRangle firma 19
X
EK] 4 1 39 Ightsl =. h==E==� rectarm namwi
y. I 21 j=1 �smog�[ I regma a normal 21
}{ =1 60 Itchen ms oath—�E==[� reRangle normal
k 0'L 36� 60 19 rm smooth ] ecrr anile —no
V
V
t
http://new.e-tempest.com/application/office/frameset.phn 11/11/2015
a -
NewSouth
WiNDOWSOLUTIONS
2526 Okeechobee Blvd,West Palm Beach,FL 33409•561-712-9000•CRC1330822
Property Information Building Information
Owner: CLARK,JOHN&NANCY Wind Zone: 170 MPH.
Address: 2859 DEVINE RD Exposure Category: C
FT.PIERCE, Minimum Building Dimension: 40 ft.
Mean Roof Height: 25 ft.
Risk Category:
'
Design Pressure Calculations
Opening Location Device EDevice Device Max Positive ILMax Negative
Number Zone Width(in) Height(in) F Elevation(ft) Pressure(psf) Pressure(psf)
1 Int 80 38 7 40.0 -43.6
2 Int 32 38 7 42.1 -45.7
3 Int 96 50 7 38.8 -42.4
4 Int 40 39 7 41.9 -45.4
5 Int 40 39 7 41.9 -45.4
6 Int 80 50 7 39.3 -42.9
7 Int 63 50 7 39.9 -43.5
8 Int 63 50 7 39.9 -43.5
9 Int 60 50 7 40.1 -43.6
10 Int 60 50 7 40.1 -43.6
11 Int 32 38 7 42.1 -45.7
12 Int 80 38 7 40.0 -43.6
13 Int 80 38 7 40.0 -43.6
14 Int 80 38 7 40.0 -43.6
15 Int 32 38 7 42.1 -45.7
16 Int 32 38 7 42.1 -45.7
17 Int 64 39 7 40.6 -44.1
18 Int 40 39 7 41.9 -45.4
19 Int 32 38 7 42.1 -45.7
20 Int 40 39 7 41.9 -45.4
21 Int 52 80 7 39.2 -42.8
22 Int 30 80 7 40.7 -44.3
23 Int 36 80 7 40.2 -43.8
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.5th Edition(2014)Florida Building Code.
Page 1 of 1
Opening I Size
(WxH)
1. 3 Ight sl 80 x38
(ded 1)
2.,21ght sl 32 x38
(bath)
3. 3 Ight sl 96 x50
('Vg rm) 8 7 t i Z
4. 2 Ight sl 40 x39 O u
(storage) f
S. 2 Ight sl 40 x39 6
(kit) 9 0
6. 3 Ight sl 80 x50
(fla nn) 23
7. 2 Ight sl 63 x50 °�+"�
#16 rm) 12 11 1 U 5
B. 2 Ight sl 63 x50 4 Z $
(fla nn) ��
9. 2 Ight sl 60 X50 ti
(fla rm) 17 / 3
10. 2 Ight sl 60 x60 v
(fla rrn)
11. 2 Ight sl 32 x 38
(bath) 13 18 22
U
12. 3 Ight sl 80 x 38 Y
(bed 2) 0
13. 3 Ight sl 80 x38 19 r
(bed 2) 15 16
14. bed 1 80 x38
(3 fight sl) 20 0 0
15. guest hse 32 x 38 14
(2 Ight sl)
16. guest hs 32 x38 21 3 V
(2 Ight sl)
17. guest hs 64 x39 Z
(2 Ight s/) Q Q
18. guest hs 40 x39 Z ry—
(2 Ight si) 1 2 W U
06 19. guest bath 32 x 38
(2 Ight sq Z Z of
20. guest hs 40 x39 W LlJ
(2 Ight sQ
O C)21. smooth 52 x 80 F-
(entrance) u~„
V7
22. smooth 30 x80 w
(kitchen) CN
/
I 23. smooth 36 x 80 5 I
(fl y .
J
U
NTE-TEM-COM
SCALE:C
NOT TO SCALE
DATE:
Nov 11,2015
PAGE DESCRIPTION:
Site Plan
PAGE: OF
5
a
11/6/2015 Florida Building Code Online
Date Submitted 07/02/2015 `
Date Validated 08/06/2015 ,
Date Pending FBC Approval
Date Approved 08/11/2015
summary of Products
Go to Page Page 1/20 0
PL# Model,Number or Name Description—�-- ----�_-W
16842.1` a. 9500 Slider XO Extruded Vinyl "Non-Impact" Horizontal Sliding Window
I utilizing a Nall Fin Installation (XO or OX configurations)
Limits of Use _- ---- ^--- i Certification Agency Certificate T�
Approved for use In HVHZ; No FL16842 R2 C CAC NAMI Cert for 16842.1 (60 x 60).odf
Approved for use outside HVHZ:Yes i Fr 16842 R2 G CAC NAMI Cert for 16842.1 174 x 621,odf i
Impact Resistant: No FL16a42 R2_C CAC NAMI Cert for 16842,1 (7g x0,2).odf i
Design Pressure: N/A Quality Assurance Contract Expiration Date
Other: See INST 16842.1 for Design Pressure Ratings, any 05/31/2017
additional use limitations, installation instructions and product Installation Instructions
particulars. FL16842 R2 II Inst 16842.1.adf
Verified By: Lyndon F, Schmidt, P.E. 43409
i Created by Independent Third Party; Yes
Evaluation Reports
FL16942 R2 AE Evals 16842.1.Ddf
Created by Independent Third Party; Yes
Extruded Vin p
16842.2 � i b. 9500 Slider XO yl "Non-Impact"Horizontal Sliding Window with i
Flange Installation(XO or OX configurations) t
A -
Limits of Use Certification Agency Certificate
pproved for use In HVHZ: No FL16842 R2 C CAC NAMI Cert for 16842.2(60 x 60),12df i
Approved for use outside HVHZ:Yes FL16842 R2 C CAC NAMI Cert for 16842.2(74 x 62),.Ddf
Impact Resistant: No i FL16842 R2 C CAC NAMI Cert for 16842.2(74 x_62)_,D_df t
Design Pressure: N/A i Quality Assurance Contract Expiration Date
Other:See INST 16842.2 for Design Pressure Ratings, any 05/31/2017 1
additional use limitations, installation instructions and product Installation Instructions
particulars, FL16842 R2 II_inst 16842.2.adf
Verified By: Lyndon F. Schmldtr P.E.43409
Created by Independent Third Party: Yes
Evaluation Reports j
FL16842 R2 AE Evals 16842,2.pdf j
Created by Independent Third Party: Yes
16842.3 i c. 9500 Slider XO Extruded Vinyl "Impact"Horizontal Sliding Window utilizing a
Nail Fin Installation(XO or OX configurations)
Limits of Use Certification Agency Certificate
Approved for use In HVHZ: No FL16842 R2 C CAC NN6MI Cert for 16842.3(74 x 63).,Dd1
Approved for use outside HVHZ:Yes FL16842 R2 C CAC NAMI Cert for 16842,3(74 x 63) odf
Impact Resistant:Yes Quality Assurance Contract Expiration Date
Design Pressure: N/A 09/30/2017
Other:-See INST 16842.3 for Design Pressure Ratings, any Installation Instructions
additional use limitations, installation instructions and product FI-16842 R2 11 Inst 16842.3.Ddf
particulars. Verified By: Lyndon F. Schmidt, P.E. 43409
l I Created by independent Third Party: Yes
Evaluation Reports
8.16842 R2 AE Evals 16842.3.2df
j Created by Independent Third Party: Yes
---- --- - ------ --- -- ...._-..... .._---- _ •------- _ ._
F16842.4 d. 9500 Slider XO Extruded Vinyl "Impact" Horizontal Sliding Window with i
Flange Installation(XO or OX configurations) -- —
Limits of Use — - i Certification Agency Certificate
4 Approved for use in HVHZ:No ( FL16842 R2 C CAC NAMI Cert for 16842.4(74 x 63)..odF
Approved for use outside HVHZ: Yes FL16842 R2 C CAC NAMI Cert for 16842.4(74 x 63).Ddf
Impact Resistant: Yes •Quality Assurance Contract Expiration Date
Design Pressure: N/A 1 09/30/2017
Other. See INST 16842.4 for Design Pressure Ratings, any :Installation Instructions
additional use limitations, installation Instructions and product; FL16842 R2 II Inst 16842 4 odf
particulars. i Verified By: Lyndon F. Schmidt, P.E.43409 !
Created by Independent Third Party: Yes
I Evaluation Reports
FL16842 R2 AE Evals_16842.4.odf
Created by independent Third Party: Yes
16842.5 ;e. 9500 Slider XO- Impact Rated- Extruded Vinyl "Impact"Horizontal Sliding Window utilizing a
HVHZ Nail Fin Installation(XO or OX configurations)
Limits of Use Certification Agency Certificate
Approved for use in HVHZ:Yes ( E416842 R2 C C NAMi Cert for 16842.5(74 x 63).Ddf
Approved for use outside HVHZ:Yes (Quality Assurance Contract Expiration Date
haps://floridabLilching.orglprlpr_app dU.aspx?Wam=wGEVXQwtDgtmmTSTNdVPsf/.2fLKgxApZZOMacKkAOnrZO111loRVQrXw%3d%3d 216
11/6/2015 Florida Building Code Online
n m—
s r A
_ �F�`�D DEC2015
6
1
'`�`: 3 uri .�,TTlijl:c{ BCIS Home Log In j User Registration i Hot Topics Submit Surcharge . Stats&Facts ! Publications FBC Staff BCI;�Site Map ( Links Search
Busines 'jm� N
a��i�� T�� �'�n d,S�hi,� +r-tr- c�
Professi *n DoT ProductApproval� t� 2
U I USER: Public User } A,
?c tr.
Regulation: ��— ��� �' ��r
Product Approval Menu>Product _r Aoolfcation•'SeaichApph ac LinList ;_u
Search Criteria Refine Search
Code Version 2014 FL# 16842.12
Application Type ALL Product Manufacturer ALL
Category ALL Subcategory ALL
Application Status ALL Compliance Method ALL
Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL
Product Model, Number or Name ALL Product Description ALL
Approved for use in HVHZ ALL Approved for use outside HVHZ ALL
Impact Resistant ALL Design Pressure ALL
Other ALL
Search Results-Applications
FL# Type Manufacturer Validated Statusj
I� !
FL16842 Revision NewSouth Window SolutionsRyan J King, Approved
2rx"" .t FL# .FL16842 12 E a. 5, "`;B' M�s .r * - --
History Model:-I. 9500-'3-Slider`XOX Impact Rated - HVHZ (813) 787-
Description: Extruded Vinyl "Impact" Horizontal Sliding Window with Flange 8283
Installation (XOX, configuration)
Category: Windows I' i
I i
( Subcategory: Horizontal Slider
I
`Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
Fi
Contact Us:: 1940 North Monroe Street,Tallahassee FL 32399 Phone: 850-487-1824 {�
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida. :: Privacy Statement::Accessibility Statement:: Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395. -Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S. must provide the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter
455,F.S.,please click here.
Product Approval Accepts:
EF, Z
sccurit. use rritc5
https://floridabuilding.org/pr/pr_appjst.aspx 1/1