Loading...
HomeMy WebLinkAboutProduct Approval (5) 11/23/2015 Florida Building Code Online 7777, _ =s 1 0qq t %g 77 j 4 F �> ''x, ^AiMK� _"on,o-r,,.,„.x� 1' ��.€..A•v.\X�� � JF F'.➢"$,g y.R 39�` 'E, .'t ��� � nvewww ., sf L' wWr b 4 i fl. L•,w.....'aw.a...._.uu "`. ,w+..v...,..+.[-' `w+."' .. n+,.a.. .a..-awa....,mw....�..a._ew..tu „..v,..r..,..,:.rua.da:z�..+::! #1MKITM ;a; ( %..,„p. ,_ ,j BCIS Home Log In User Registration Hot Topics ' Submit Surcharge Stats&Facts i Publications FBC Staff BCIS Site Map Links Search Busines. Professi nal :tit P Approval 'USER:ER: PubPublic User Regulation ...'�. V Product Approval Menu>Product or Application Search>Application List>Application Detail FL# FL�17184-R2 a Application Type Editorial Change Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Plastpro Inc. / Nanya Plastics Corp. Address/Phone/Email 5200 W CENTURY BLVD. LOS ANGELES, CA 90045 (440) 969-9773 Ext 16 rickw@rwbldgconsultants.com Authorized Signature Vivian Wright rickw@rwbldgconsultants.com Technical Representative Scott Johnson Address/Phone/Email 5200 W Century Blvd. Los Angeles, CA 90045 (440) 969-9773 Ext 18 scottjohnson@plastproinc.com Quality Assurance Representative Address/Phone/Email Category Exterior Doors 6categpo' SwingingExte'ri:or�Door=Assernblies -. ,a; Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F. Schmidt, P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation &Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By Ryan J. King, P.E. Validation Checklist- Hardcopy Received Certificate of Independence FL17184 R2 COI CERTIFICATE of INDEPENDENCE.pdf Referenced Standard and Year (of Standard) Standard Year AAMA/W D MA/CSA101/I,S.2/A440 2005 ASTM E1886 2005 ASTM"E1886 2002 ASTM E1996 2002 ASTM'E1996 2006 ASTM E1996 2005 ASTM E330 2002 TAS 201, 202, 203 1994 https://www.floridabui ldi ng.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvCo3Eapi II BW 4u90°/`2bpvEj LDyyVB49OUxg5aOgK%2bKlZvA%3d°/`3d 1/5 11/23/2015 Florida Building Code Online • Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 07/17/2015 Date Validated 07/19/2015 Date Pending FBC Approval 08/09/2015 Date Approved 10/16/2015 Summary of Products Go to Page 4) 0 Page 1/ 310 0 ........................_._..._............._..................................... ._......---.............................---...._..._._................................................ _._._.............................__._.........................._...._.............._..._....._.__—........._..__............................---------........................................... ...; FL# ;Model, Number or Name Description 17184.1 a. Fiberglass Door (Up to a 3'0 x 8'0 Glazed "Impact" Fiberglass Single Door(X I Configuration) Inswing/Outswing ---—----_-..._........_................._......_................._.._................_..._.....---._._._............................................_.............................._.—._----............_..........................._.._.._.—_._..............—_...................._.._..........................._......_........._.; Limits of Use (Installation Instructions Approved for use in HVHZ: No FL17184 R2 II Inst 17184.1.pdf Approved for use outside HVHZ: Yes j Verified By: Lyndon F. Schmidt, P.E. 43409 j Impact Resistant:Yes Created by Independent Third Party: Yes I Design Pressure: N/A j Evaluation Reports Other: See INST 17184.1 for any additional use limitations, FL17184 R2 AE EVAL 17184.1. installation instructions and product particulars. I Created by Independent Third Party: Yes _............._._..----._....--......................................_..._..----- ........_..._._ ._._..............................................._., ........-........_.._ ----.._._..__......._..........-- —-.. .._.._..............._._............_..... 17184.2 b. Fiberglass Doob Up to a 3'0 x 8'0 Glazed "Impact" Fiberglass Single Door with I a Sidelite (OX or XO Configurations) Inswing/Outswing I Limits of Use I Installation Instructions Approved for use in HVHZ: No i FL17184 R2 II INST 17184.2.pdf Approved for use outside HVHZ: Yes I Verified By: Lyndon F. Schmidt, P.E._43409 Impact Resistant: Yes I Created by Independent Third Party: Yes i Design Pressure: N/A Evaluation Reports Other: See INST 17184.2 for any additional use limitations, FL17184 R2 AE EVAL 17184.2.pdf I installation instructions and product particulars. Created by Independent Third Party: Yes i 17184.3 !c. Fiberglass Door Up to a 3'0 x 8'0 Glazed "Impact" Fiberglass Single Door with Sidelites (OXO Configuration) Inswing/Outswing ..............................__.......__.........................._............_.l_..--................._._..._.._.....-...._....._........................_..............._.......—---.............................._...........-....._............._......_........---—......_.....................-._.__......._.._........._................_...................... ; Limits of Use I Installation Instructions Approved for use in HVHZ: No I FL17184 R2 II INST 17184.3.ndf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure:'N/A Evaluation Reports Other: See INST 17184.3 for any additional use limitations, I FL17184 R2 AE EVAL 17184.3.pdf installation instructions and product particulars. Created by Independent Third Party: Yes I 17184.4 d. Fiberglass Door (Up to a 6'0 x 8'0 Glazed "Impact" Fiberglass Double Door (XX Configuration) Inswing/Outswing -._..._. ..........._.._.._ Limits of Use I Installation Instructions Approved for use in HVHZ: No FL17184 R2 II INST 17184.4.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F, Schmidt, P.E. 43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 17184,4 for any additional use limitations, FL17184 R2 AE EVAL 17184.4.pdf installation instructions and product particulars. — Created by Independent Third Party: Yes __._..............__........-...---._.................................:...........__.........................._.........__...._..__.—_....................._.............._..._.__.................._............................. _ —....._......_..............._..._......_.._.----_......__._...--_...-----.................................................. _......._.l 17184.5 e. Fiberglass Door Up to a 6'0 x 8'0 Glazed "Impact" Fiberglass Double Door with Sidelites (OXXO Configuration) Inswing/Outswing Limits of Use Installation Instructions Approved for use in HVHZ: No FL17184 R2 II INST 17184.5.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 17184.5 for any additional use limitations, FL17184 R2 AE EVAL 17184.5.1)df installation instructions and product particulars. Created by Independent Third Party: Yes --......_............_----.... ...._.....,..........._...._._.... 17184:6f. Fiberglass Door Up to 3'0 x 8'0 Glazed "Non-Impact" Fiberglass Single Door (X Configuration) Inswing/Outswing ........ _._e___ .._._............._.....__.._.. .......................-_........_.........................._...... _....__.......... ..._....... - _................._ _ ._-_.._.....__...._......._.- -----....................................... ......i Limits of Use _ Installation Instructions https://www.floridabuilding.org/pr/pr_app dtl.aspx?param=wGEVXQwtDgvCo3EapiIIBW4u90%2bpvEjLDyyVB49OUxg5aOgK%2bKlZvA%3d%3d 2/5 11/23/2015 Florida Building Code Online Approved for use in HVHZ: No j FL17184 R2 II Inst 17184.6.odf Approved for use outside HVHZ: Yes ! Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No 1 Created by Independent Third Party: Yes Design Pressure: N/A I Evaluation Reports Other: See INST 17184.6 for any additional use limitations, FL17184 R2 AE EVAL 17184.6.odf installation instructions and product particulars. Created by Independent Third Party: Yes ----..__—. __...__.._.._._........------.._..._.........._._.. -....� _._._.._.. —..._.._....__.. _--_........._...........-- ........._...._......... -................................._.._.............. : 17184.7 g. Fiberglass Door I Up to a 3'0 x 8'0 Glazed "Non-Impact" Fiberglass Single Door with a Sidelite (OX or XO Configurations) Inswing/Outswing Limits of Use Installation Instructions i Approved for use in HVHZ: No FL17184 R2 II INST 17184.7.odf j Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A I Evaluation Reports Other: See INST 17184.7 for any additional use limitations, FL17184 R2 AE EVAL 17184,7.pdf installation instructions and product particulars. Created by Independent Third Party: Yes --._.._._.�..._.__._.._...---------- -..__..__.................._.._...._.._ -..................................---r------._...._......_._..._.._...----...._............._.__. ---.__.....__...---..............._._.........._....._....., 17184.8 1 h. Fiberglass Door 'Up to a 3'0 x 8'0 Glazed "Non-Impact" Fiberglass Single Door I I j with Sidelites (OXO Configuration) Inswing/Outswing ................... - ._-...._.........._....._........_.....................__.............._....-----......_..._...............................--.;_..__..._..................._--- -- Limits of Use Installation Instructions Approved for use in HVHZ: No FL17184 R2 II INST 17184.8.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 17184.8 for any additional use limitations, FL17184 R2 AE EVAL 17184.8.odf j installation instructions and product particulars, j Created by Independent Third Party: Yes .............._...........-------..................................._..._........-----.._......._......_......._...._...._..................._........_...._...._.._...._-..........................._.._...- --.-._..............._._._. -----..._......_..............._.........._ L 17184.9 1 i. Fiberglass Door Up to 6'0x 8'0 Glazed "Non-Impact" Fiberglass Double Door Il (XX Configuration) Ins ing/Outswing -- ......_.._...._..__._....._..... --.......... - ---- ........... - — -............_.._...._....__._.._...—_.......I.........-.......- ..—_.........--..._._................._._...................-----....._..... , Limits of Use I Installation Instructions Approved for use in HVHZ: No 1 FL17184 R2 II INST 17184.9.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No ; Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 17184.9 for any additional use limitations, j FL17184 R2 AE EVAL 17184.9.pdf installation instructions and product particulars. I Created by Independent Third Party: Yes .........._........._..__......._................................................_.............._......................................................................................................._.._.............1.........................._..............._.................................................._.. ---...--................_........._...................._.._............................_........_...._....., 17184.10 j. Fiberglass Door f Up to a 6'0 x 8'0 Glazed "Non-Impact" Fiberglass Double Door with Sidelites (OXXO Configuration) Inswing/Outswing Limits of Use i Installation Instructions Approved for use in HVHZ: No FL17184 R2 II INST 17184.10.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A j Evaluation Reports Other: See INST 17184.10 for any additional use limitations, FL17184 R2 AE EVAL 17184.10.1)df installation instructions and product particulars. Created by Independent Third Party: Yes _................-.......------_..__...__.................._..._....i_....___....._..__..__.._....--........ ...._.................................._.. ---..,..................._.............------ .......__..._......-- -- ._..__........-------_.._......_.................._.........._; 17184.11 ;k. Fiberglass Door I Up to a 3'0 x 6'8 Opaque "Impact" Fiberglass Single Door (X 1 Configuration) Inswing/Outswing j .....................__......----........................................._.........1_._._.__..............................................................................................................._............_.._.................................._...................__..........................._.............._.........__......_.._._.._.._..._._.._..__............-....._.._..........................................; Limits of Use Installation Instructions Approved for use in HVHZ: No FL17184 R2 II INST 17184.11.odf Approved for use outside HVHZ: Yes 1 Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 17184.11 for any additional use limitations, I FL17184 R2 AE EVAL 17184.11.pdf installation instructions and-product particulars. .. ,.,Created by Independent Third Party: Yes _ _ _ ill 184 12 1�rtI Fibergiass DooL Up to a 3 0 x 8_6 Opaque Impact Fiberglass Single Door with a'SI 9,lte (,Ox�or XO Configurations) Inswing/Outswing `j`,'��""–_`.`•`"._.. L`.�.._.'__"–�' -= — - _._._.` a '"cw_...""""''' _"sem..z Y .' -. Limof Else ^i {t r ' Installation Instructions �E\pprovedforuswm NVHZ �Vo r;`�r� FL17,184 R� II 31�5T 17184-1-2-'odf 3 Approved for,u `Yes Wei�� ,A t i\/erfied�By Lyndon Schm'icit, PYE 43409 endenr Impart Resistant�es — _ Crested by Indept ThirdPa *Cfther See INS 17 Design ,64Zfn� a�dit;an 1(Ruse lirriiba�iors i�FLL7184 k RAEoEVAL 17184 12 odf j linsta latio Cs�uctidris,en-ii,product articulars �` "moi Created b'Tnde �ndent�lhird Par 3`Yes _.�_ P Y p __,• 17184.13 m. Fiberglass Door I mpc a S delite (OXO COpaque.,,n)aIns�niing OutswSn9gle Door with Limits of Use Installation Instructions Approved for use in HVHZ: No I FL17184 R2 II INST 17184.13.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 17184.13 for any additional use limitations, FL17184 R2 AE EVAL 17184.13,odf installation instructions and product particulars. 1 Created by Independent Third Party: Yes ........................__....._....................._..............._....._...._ _._............._...._.....................__.....__..._........._................................._.__.........._...._._.I...._..................................._._.........-...................................--- _..._.._._..---._-_..._..............._..............._................._...._._; https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvCo3EapilIBW4u90%2bpvEjLDyyV849OUxg5aOgK%2bKlZvA%3d%3d 3/5 11/23/2015 Florida Building Code Online 17184.14 n. Fiberglass Door I Up to a 6'0 x 6'8 Opaque "Impact" Fiberglass Double Door(XX i Configuration) Inswing/Outswing I _...--- --.._.........__.._.__ ._-_._._...__........................................................_....................... ---- .--...................._..._._........-....... _.........__...._..-- Limits of Use Installation Instructions Approved for use in HVHZ: No FL17184 R2 II INST 17184.14.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 17184.14 for any additional use limitations, FL17184 R2 AE EVAL 17184.14.pdf installation instructions and product particulars. Created by Independent Third Party: Yes .........................._....-.................._......_....__............_..._......_................_............................._............................................_...........................................--.--...._....................................-.................._-._.._...__.............._......................_....:.........._................._........................................... 17184.15 c. Fiberglass Door ;Up to a 6'0 x 68 Opaque "Impact" Fiberglass Double Door with Sidelites (OXXO Configuration) Inswing/Outswing Limits of Use i Installation Instructions Approved for use in HVHZ: No FL17184 R2 II INST 17184.15.odf Approved for use outside HVHZ: Yes I Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A I Evaluation Reports Other: See INST 17184.15 for any additional use limitations, I FL17184 R2 AE EVAL 17184.15.pdf installation instructions and product particulars. Created by Independent Third Party: Yes .......-----......_._._.......__............. ... _..........__..........._.................__.........._._.=................................_..- -- -.._._... ....._......-.....---....................._...-- ---....................................... ......_; - __..----_......_...-__._...�W_--- -------.—..._._-...._.....__.._......._._._.._._....__-_ _._...__._.._.._............_—.. 17184.16 p. Fiberglass Door Up to a 3'0 x 8'0 Opaque "Impact" Fiberglass Single Door (X Configuration) Inswing/Outswing ......................_.._-......---._.............._.......-..........._..__a.. -..................._......_._ - _................................--............°.....-......_.------------....................................._._._. _..__.........._.-- --.._......................................__......_._ Limits of Use f Installation Instructions Approved for use in HVHZ: No FL17184 R2 II INST 17184.16.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 17184.16 for any additional use limitations, I FL17184 R2 AE EVAL 17184.16.1)df installation instructions and product particulars. Created by Independent Third Party: Yes ------........................................._- 17184.17 (q. Fiberglass Door Up to a 3'0 x 8'0 Opaque "Impact" Fiberglass Single Door with a Sidelite (OX or XO Configurations) Inswing/Outswing Limits of Use !Installation Instructions Approved for use in HVHZ: No FL17184 R2 II INST 17184.17.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E..43409 Impact Resistant: Yes i Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 17184.17 for any additional use limitations, FL17184 R2 AE EVAL 17184.17.pdf installation instructions and product particulars. i Created by Independent Third Party: Yes ........._.__..__......................_.............................._j._...__............-....._..............------......_....................._.__....-..........................._........_---- ...__.-_.............-.._..- --.......__..__._...-----........_..........................._....... , 17184.18 r. Fiberglass Door Up to a 3'0 x 8'0 Opaque "Impact" Fiberglass Single Door with a Sidelite (OXO Configuration) Inswing/Outswing Limits of Use - Installation Instructions Approved for use in HVHZ: No FL17184 R2 II INST 17184.18.pdf Approved for use outside HVHZ:Yes ( Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A i Evaluation Reports i Other: See INST 17184.18 for any additional use limitations, ': FL17184 R2 AE EVAL 17184.18.pdf installation instructions and product particulars. 1 Created by Independent Third Party: Yes ..............._......._...._...........-......._.....................-.._.._....I..__........._..........._........_...._._.__...._............_...................................................._.._...... -................._-....._...._.............................................._......._._........_....._._......__._...._.-----._...._.............-............... ...._........_.........: 17184.19 s. Fiberglass Door j Up to a 60 x 8'0 Opaque "Impact" Fiberglass Double Door(XX ! iConfiguration) Inswing/Outswing j ----------......_..........._---.--_......_....... - - ------.......... Limits Limits of Use 'Installation Instructions Approved for use in HVHZ: No FL17184 R2 II INST 17184.19.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant:Yes i Created by Independent Third Party: Yes Design Pressure: N/A (Evaluation Reports Other: See INST 17184.19 for any additional use limitations, FL17184 R2 AE EVAL 17184.19.pdf installation instructions and product particulars. ; Created by Independent Third Party: Yes j .......... __.................._....... ..............._.....-.............-......._........................................-........................_..__..__ _...._..................._-....................._.......-... --- -- _._.__.._..._......._..._.._......._._......._:.................---I 17184.20 t. Fiberglass Door i Up to a 6'0 x 8'0 Opaque "Impact" Fiberglass Double Door with Sidelites (OXXO Configuration) Inswing/Outswing Limits of Use Installation Instructions Approved for use in HVHZ: No I FL17184 R2 II INST 17184.20.1)df Approved for use outside HVHZ:Yes I Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A i Evaluation Reports Other: See INST 17184.20 for any additional use limitations, FL17184 R2 AE EVAL 17184.20.pdf installation instructions and product particulars. Created by Independent Third Party: Yes Go to Page I (Did Pagel/30 0 https://www.floridabuildi ng.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvCo3Eapi II BW4u90%2bpvEj LDyyVB49OU xg5aOgK%2bKlZvA%3d%3d 4/5 77 plastpro . .__ ••/ _ f \Q N 5200 W. CENTURY BLVD. ` ;` ;N'•? z M LOS ANGELES, CA 90045 - On z fill - / 76.25"MAX.OVERALL FRAME WIDTH `v. ({ N Lo m m c w OPAQUE FIBERGLASS DOOR N� � t m 3750"MAX. 37.25'MAX. WITHSIDELITE FRAMEWIDTH�I rfRAMEWIDTH _I �Z INSWING/OUTSWING r z� ,,impAcr, a 4 oZ R 0 GENERAL NOTES :+ (z) Oz � 000 z w Ir" IDZ 1. This product has been evaluated and is in compliance with the 5th Edition(2014)Florida z o i 5o w OL Building Code (FBC)structural requirements excluding the"High Velocity Hurricane Zone" HVHZ, LD( ) S N O] Q Q D ULO v) 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to 1o base material shall be beyond wall dressing or stucco. „� ® >k a `a a Y} 3. When used in areas requiring wind bome debris protection this product complies with W X O 'm Section 1609.12 of the FBC and does not require an impact resistant covering.This product >- c O4 U "`- meets missile level"D"and includes Wind Zone 4 as defined in ASTM E 1996 and Section � o' Cm 1609.1.2.2 of the FBC. 6 4. For 2x stud framing construction,anchoring of these units shall be the some as that shown for 2x buck masonry construction. m m;K � w LD 5. Site conditions that deviate from the details of this drawing require further engineering ` / > w analysis by a licensed engineer or registered architect. w o K", o a TABLE OF CONTENTS 3 SHEET# DESCRIPTION a1 Typical elevation,design pressures,&general notes a 2 Door panel details OVFRAii OVERALL pES(GNPRESSURE(P5F)j a o z LL 3 Sidelite panel details GLASS o 0 z 4 Horizontal cross sections ; SWfNG.- FRAME ",DLO .. "z 5 Vertical cross sections DIMENSION: DIMENSIONP F SITIVE NEGATiUE; BnTe 8/25/14 6 Vertical cross sections INSWI'[N 76 2rs 1c 82 00 U2 SO"6Z 7 N� 5f} r�,-50.0 S N.T.S. 7 Buck and frame anchoring-2X buck masonry construction 3 DWG.BY.. AL m GTS a 8 Frame anchoring-1 X buck masonry construction �� i CHK.BY. LFS 3 o OUTSWING.r 76 25 x 80 50 10 5Q.x.b2 75 �..` #$0 Q $0,0 rc 9 Bill of materials,glazing detail&components d`. DRAWING NO.: -- FL-17184.12 a 1 OF SHEET 9 N U •R:\Clients\Plastpro,Inc PERMANENT\Florida Product Approvals\FL-17184\C-Drawings\Current\FL-17184.11-.20,dwg,2.2 79.25"MAX.DOOR PANEL HEIGHT a w o v w z O �O y v � x01� � 90 m = V a N m r O D m D m A �— � ra N 2 � N �0n0 00 Aa cq O 0 0 n r o'1 41G) d A r Z m a D m m z 2 A An �3 o O T O �b Z N s, 0 v S 4 As } o 'n o= 3 x ---- ~m Fes- , m 1.58" rn Y � - m N lV m n 0 N tA m � m Z � O A `,\\Ill ll 1111!/ffT No.434D9 G .27-vis�5 p� T n g PRODUCT: Documents Precered By: PLASTPRO Lyndon F. Schmldt �••'••FZORIOP•:'Gp`� IN V o 2 N FIBERGLASS DOOR P.E. No. 43409 /7�S o Do r- y PART OR ASSEMBLY: BUILDING CONSULTANTS, INC. ? to 1 04722715 UPDATE TO 5TH ED. (2014) FPC JK J l��P.O. Box 230, Valrico, FL 33595 Ka 4 NO DATE 8Y DOOR PANEL DETAILS Phone No.: 813.659.9197 REVISIONS FBPE C.A. No. 9813 0 2014 R.W.OUILDINu CONSULTANTS INC. R:\Clients\Plastpro,Inc PERMANENT\Florida Product Approvals\FL-17184\C-Drawings\Current\FL-17184.11-.20.dwg,3.2 A w 79.25"MAX.SIDELITE PANEL HEIGHT 62.75"MAX.D.L.O.HEIGHT a o - Zw V S-- L!h .. m 4.5" -�11.59 W o N O.C. -o Oo O D N =x Q Q 0 CIN K3 N .OC2 OTI O rn m m M M n o 0 OA Z7 o N m Z 61 m o � � V P V $ W < 3g �x a m m m T N n M A O qO1 ci �EJ rn �— ,I1111I111/// 0 No.43409 yt 7.iS '^ x n PRODUCT: y D... nts Prepored By: PLASTPRO Lyndon F. Schmidt �'i�s•••!20RfOP.:•G•��`` FIBERGLASS DOOR P.E. No. 43409 /1/11111111` Q C' r -1 - PART OR ASSEMBLY: /� /�BUILDING CONSULTANTS, INC. I� rte- to 1 04722715 UPDATE TO 5TH ED. (2014) FSC JK SIDELITE PANEL DETAILS J I•VI� P.O. Box 230, Volrico, FL 33595 N NO DATE BY Phone No.: 813.659.9197 REVISIONS FBPE C.A. No. 9813 02014 R.W.BUILOINO CONSULTANTS INC. INTERIOR K1 V 2 1 2 E � ........... I K 1 O A d 35 50 0 N'.7 rc'•:p.ut °p Z z um 21 20 21 20 �'��i'7"t*i iss �``` 12 N m z EXTERIOR d a 1 v 3 KeEm ommU 7 4 v 4 \ N m oa �da `oa 22 SEE m n `� y NOTE 1 2 ° X ' 4 0 o O 4 az 4 0 3a 20 21 v z I o INTERIOR SEE ° cc 0 w 40 47 M 5 50 35 22 NOTE 1 °" Co EXTERIOR F--- 1-1/4"MIN. m 4 D 4 D EMB.(TYP.) �cD w 4 HORIZONTAL CROSS SECTION, o 5 HORIZONTAL CROSS SECTION o 4 Outswingconfiguration 4 Shown w/1Xsul�buck a zo 3 4 3 4 5 o 5 5 6 6 6 1-1/4"MIN. NOTE: 1-1/4"MIN. a a y EMB.(TYP.) 1.Sidelite panels anchored to frame 6" EMB.(TYP.) 0.15' from top of frame then 10"O.C.(TYP.) m C f- C'SINK (B)screws total each jamb. K BB D L InP) 5 SIN C'SINK m (TYP.) 21 20 20 21 8 0 20 21 21 20z O0 7 22 SEE EXTERIOR x a 40 EXTERIOR 7 NOTE 1 p a o / a `aa a � <�' G a n N O W ~ N Q F L p P O z INTERIOR 50 35 ° z 10 M 35 50 DATE: 8/25/14 i 10 INTERIOR 40 27 SEE 22 C a SME: N.T.S. ° NOTE 1 D DWG.BY: AL m' B DNK.B. LFS 3 1 HORIZONTAL CROSS SECTION 2 HORIZONTAL CROSS SECTION 3 HORIZONTAL CROSS SECTION E DRAWNG ND.: E ° 4 Inswing shown-outswing 4 Inswing configuration 4 Inswing shown-outsw ng FL-17184.12 also approved also approved SHEET 4 OF 9 " V K R:\Clients\Plastpro,Inc PERMANENT\Flodda Product Approvals\FL-17184\C-Drawings\Current\FL-17184.11-.20.dwy,52 m m Z Z °f p m m 4 ° !Js W H .. ° 4 c) o0 ran '01 4° Q)s clool o A �rn0 Q m 7 y , y � ° °4 N O A m A ~ O ~ O V O iT1 Q 4' z c co W d ° 0.15" pp.) 1-1/4"MIN. 1-1/4"MIN. EMB.(TYP.) EMB.(TYP.) r 1-1/4"MIN. EMB.(TYP.) m " w Z cn N m ° ° oA A o a m X r < 0 0 f017 �y N p - °° n r) — e � m ° 0 Z m F" ° IZ1 F" Z ° � V ° m 0 70 O N N z O C1 1-1/4"MIN, EM m B,rrYP.) &•$C.�J/Q No.43409 •" n PRODUCT: aocuments Prepared By: 't f " Lyndon F. Schmidt ���••••.`? DR�•G\��� ?K .. PLASTPRO p E. No. 43409 ���Sar W FIBERGLASS DOOR // /Q 01 o PART OR ASSEMBLY: V1( BUILDING CONSULTANTS, INC. ? L1 [NO 04722/15 UPDATE TO 5TH ED. (2014) FEC JK J l� P.O.. Box 230, Valrico, FL 33595 a ; DATE EIY VERTICAL CROSS SECTIONS Phone No.:-813, 59.9197 N REVISIONS FBPE C.A. No. 9813 201 4 R•W.8 H-1—C....SIA.-INC. Av . i�Y •GJ� a°D;n �•••••......... > z 8 ��rrrr Pty�� o nn..z U N D E z o z Zo 0 m e >p n o E m b m o Sa C A \( N 4n °tm Za co moi✓ `oz 35 C 2 w 0 3d SEE NOTE 122 h Z a 35 z O SEE 50 21 NOTE 1 22 2U 0 00 En NOTE: in y INTERIOR EXTERIOR 1.Screws thru frame into sidelite panel 5 3 m c located 6"from corners of sidelite and 1 VERTICAL CROSS SECTION O centerline of sidelite INTERIOR EXTERIOR 6 Inswing shown-outswing < F aalso approved 2 VERTICAL CROSS SECTION G o 6 Shownw/1X sub-buck �I a INTERIOR EXTERIOR m INTERIOR EXTERIOR 50 SEE INTERIOR EXTERIOR m A 22 NOTE 1SEE(�k 0 29 NOTE I SEE z 31 50 50 22 NoiE 1 20721 W o z� za p 34 E 35 n I a u a _ a F z DATE: 8/25/14 i : SCALEN.T.S. ° z a � _ DWG.BY: AL m CHK,BY: LFS 3 DBAWINO NO.: 3 VERTICAL CROSS SECTION 4 VERTICAL CROSS SECTION 5 VERTICAL CROSS SECTION Q 6 Inswing configuration 6 Outswing configuration 6 Outswing configuration FL-17184.12 0 SHEET 8 of g N V f. n16., i�Y •OJ` a z 6, S; 1 14 ILIII1I`� a N. 0 Z a E m Z m a Eq ONRY TYP.HEAD I I 1 03` t ? MASONRY TYP.HEAD 8 r Q �V, n e m a a I &JAMBSI m' OPENING JAMBS c o OP. PENING I t z D '; II TY FRAME — 0 3d t MULLION No 2X Bk SHOWN FOR ¢ a..A N v oi f cn� REFERENCEII °� 2X BUCK CJ c�i. �, 1 f h ONLY i`s 1 y, ' o Uz 00 �4'a. F SILL F SILL a N J wow } ng�ED `¢2 co OD o fez al a BUCK ANCHORING HINGE JAMB R FRAMEANCHORING STRIKEJAMB 1 Masonry 2X buck construction m V N O Z o O CO CRETE ANCHOR NOTES: ai L I Concrete anc rlocattons+at)he Gainers maybe adlusteaintain the min. 9 28 0 r e drgn e*to�matfar)oiris`x MWM "2 Concrete anchor locafron�s�note�-!'&9X ON�yCtE�NiER must be adjusted to 10 0 maintain the in.e_gege distance tom ?nts;addihona�!concretefanchors a may begl2itedttaensu `MAXOF(xCC1�7RF drinensron are not exceeded 10 Z 3 Concrete anchor table s w i p N H Q ACdI�O& dNC OM M)N CLEARANCE MW.GLEARANCE: lO v Qo 7 M o a TO F�IASONRY TO ADJACENT o w1YPE SIZE EMBEDMEM _ EDGE ANCHORDD DATE 8/25/14 Z TAPCONw �Y� i SCALE: N.T.S. ULTR`3CON��7�4 sem= `71 4" _ T �'- w 4" HINGE DETAIL LATCH&DEADBOLTDETAIL DWG.BY: AL m o �NO'ODSCREW INSTALLA71ONNOTES: - -'= Yrt-- t_''_ra.;F.: e:spaCHK.BY: LF S 3 d -`+ DRAWING NO.: R 1A amtoin a minimum i" 5/8"edge distance,I"end distance,8 o: cof Q — oodscrews-to`pr&ent the splitting of wood. FL-77184.12 _ D SHEET 7 OF 9 N 1' -V' 6 dern 'lwr N•'7 �'r��l" o, �W .'V- z v •n 9 o°n m z° U N•; f TYP.HEAD& rn v v z° MASONRY J JAMBS cCOi lU F{ n o to o m m w OPENING5 TMP 3:A c m a a GG 0 9z W n L FRAME < HINGE DETAIL O :3z O mo .o o X? n n IX BUCKv CU m x ^ F TYP. F TYP. o m N ¢fe a SILL SILL 28 4 z �y o ¢� M 0 f o � $ t fI 1 I 1 a aim 3 HINGE JAMB FRAME ANCHORING STRIKE JAMB 0N Masonry lXbuck construction o. a �i LATCH 8 DFADBOLT DETAIL w CONCRETEANCHOR•NOTES: n 1.Concrete anchor locations of the comers maybe adjusted to maintain the min. 0 edge distance to mortar joints. 2.Concrete anchor locations noted as MAX.ON CENTER"must be adjusted to 0 maintain the min.edge distance to mortarjoints,additional concrete anchors. i may be required to ensure the"MAX.ON CENTER"dimension are not exceeded. F 8 3.Concrete anchor table: w z ANCHOR ANCHOR MIN MIN:CLEARANCE:':MIN CLEARANCE o o iOMASONRY 70ADJACENT i F TYPE SRE EMBEDMENT:, _z a ...... .. ._ EDGE......... ,:ANCHOR: z v Z RWDATE: 8/25/14 i < TAPCON® 1/4" 1-1/4" 2" 4" SCALE: N.T.S. ° ELCO ® 1/4" 1-1/4" 1" 4" DWG.BY. AL GI ULTRACON cHx,BY. LFS 3 a WOOD SCREW INSTALLATION NOTES., DRAWING NO.: _ 1.Maintain a minimum 5/8"edge distance,I"end distance,&I"o.c.spacing of FL-17184.12 ° wood screws to prevent the splitting of wood. �° SHEET 8 OF J V BILL OF MATERIALS REM DESCRIPTION MATERIAL REM DESCRIPTION MATERIAL A 1 X BUCK SG>=0.55 WOOD 20 JAMB FINGER-JOINT-PINE WOOD AV.: B 2X BUCK SG>=0.55 WOOD 21 POLYFIBER COMPOSITE JAMB POLYFIBER _U? a C 114-MAX.SHIM SPACE 22 #7 X 2'PFH DRYWALL SCREW STEEL =N,37 Z 'r O� O D 114"X 2-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL 27 LATCH STRIKE PLATE STEEL p,.• :C".;., I �m MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI 28 DEADBOLT PLATE STEEL �,� '•.-••••••••. 1z, >m m E 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE 29 SIDELITE SPACER PVC ,'i''i Ll*P1 ���` i o;6 F 114'X 2-1/4"PFH ELCO OR ITW CONCRETE SCREW STEEL 30 DOOR SWEEP '� $N Z H 1/4'X 3-1/4"PFH ELCO OR ITW CONCRETE SCREW STEEL 31 OUTSWING THRESHOLD BY DLP(QOSH) ALUM./WOOD a v z o z°v I 1/4'X 2-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL 33 INSWING THRESHOLD BY DLP(ISCS) ALUM./WOOD o t o o m c m J 1/4"X 3-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL 34 SIDELITE THRESHOLD BY DLP ISH/EIS No maa ALUM./WOOD \(I� °° °a v N ° 0 K 2X REINFORCEMENT CLEAR PINE SG>=0.42 WOOD 35 TRIM L #10 X 2-1/2"PFH WOOD SCREW STEEL 40 DOOR PANEL.-SEE DOOR PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS E z M #8 X 2-1/2'PFH WOOD SCREW STEEL 41 DOOR SKIN MIN.0.075"THICK PLAST-PRO/NANYA FY=11,063 PSI MIN. FIBERGLASS rw 5 #10 X 3"PFH SCREW STEEL 42 TOP RAIL CELLULAR PVC J a 6 SEALANT SILICONE 43 LATCH&HINGE STILE CELLULAR PVC z 7 WEATHERSTRIP FOAM 44 REINFORCEMENT WOOD FOR LOCKS WOOD N 9 4"HINGE STEEL 45 BOTTOM RAIL CELLULAR PVC o U z 10 #10 X 3/4"PFH WOOD SCREW STEEL 46 FOAM CORE POLYURETHANE oo J a 47 LATCH&HINGE STILE REINFORCEMENT LVL av) J s o 4.56' 50 SIDEUTE PANEL-SEE SIDELITE PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS 3 w c� z ¢qy o 2.12" 51 ODL LITE FRAME ALUMINUM a W N 52 #101-3/4"PFH SCREW STEEL m a o N 53 GLAZING COPOUND REDI-SEAL BY ODL,POLYMERIC FOAM P/MERIC FOAM o J o 54 STRUCTURAL SILICONE DOW#995 SILICONE $ m 55 SCREW PLUG a `a 20 HEAD&SIDE 29 SIDELITE SPACER m Jamb is I LL N 4.56" a 4.56" N � � I 3/4"GLASS o 1 BITE 53 1"OVERALL V) LE: 53 54 GLASSTHK. o o HEAD&SIDE 33 INSWING THRESHOLD d 21 fiberjamb IS 1/8"TEMPERED GLASS i Poly a AIR,SPACE z a r 4.62' 118"ANNEALED GLASS W I N Q F 4.56" 0.090"SAFLEX®PVB v- ' Q Isi- NTERLAYER O o z a 1/8"ANNEALED GLASS ^Z z 53 53 DATE.- 8/25/14 i i T - SCALE: N.T.S. ° i DWG.BY, AL m I GLAZING OElAIi SIDELITE THRESHOLD C'I CNK.Br: LFS 3 31 OIIfSWINGTHRESHOLD 34 TSH/ES Danwiuc ND.: QQSH FL-17184.12 a - o 5N SHEET 9 OF 9 g V K RW R W Building Consultants, Inc. U Consulting and Engineering.Services for the Building Industry 1� P.O.Box 230 Valrico,FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No.9813 ort TL-17184.1 Product Sub Category Manufacturer Product Name Category Swinging Plastpro Inc. Opaque Fiberglass Door Exterior 5200 W CENTURY BLVD. with,Sidelite Doors Exterior Door Assemblies LOS ANGELES,CA 90045 Inswing/Outswing (440)969-9773 "Impact" Scope: This is a:Product Evaluation report issued by R W Building Consultants, Inc.and Lyndon F.Schmidt, P.E.(System ID# 1998)for Plastpro Inc. based on Rule Chapter No.61.G20-3, Method 1 D of the State of Florida Product Approval; Department of Business&Professional Regulation. RW Building Consultants and Lyndon F. Schmidt, P.E.do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 5th Edition(2014) Florida Building Code(FBC)structural requirements excluding the"High Velocity Hurricane Zone". 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Section 1609.1.2 of the FBC and does not require an impact resistant covering.This product meets missile level"D"and includes Wind Zone 4 as defined in ASTM E1996'and Section 1609.1.2.2 of the FBC. 4. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL-17184.12 require further engineering analysis by a licensed engineer or registered architect. 6. See drawing FL-17184.12 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed by TEL 2004-07-13-016 ASTM E330-02 and ASTM E1996/1886-02 Testing Evaluation Lab.,lnc. V.K.Wright TEL 01390365 TAS 201,202,203-94 Testing Evaluation Lab.,lnc. Lyndon F.Schmidt, P.E. 2. Miami Dade NOA Materials 14-0423.16 Saflex®PVB Interlayers(Eastman Chemical Company) 3. Drawing.No. Prepared by Signed&Sealed by No. FL-17184.12 RW Building Consultants, Inc. (CA#9813) Lyndon F.Schmidt, PE. 4, Calculations Prepared by Signed&Sealed by Anchoring RW Building Consultants, Inc. (CA#9813) 43 ;_. Lyndon F. Schmidt, P.E. 5. Quality Assurance Certificate of Participation issued by National Accreditation and M° 0 Management Institute, certifying that Plastpro Inc. is manufacturing products within a quality assurance program that complies with ISO/IEC 17020 and Guide 53. r, `^ Lyndon F.Schmidt,P.E. ' FL PE No.43409 4/27/2015 Sheet 1 of 1