SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER -
Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority
Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control
Section,(hi Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right
to have this product or material tested for quality assurance purposes. If this product or material fails to
perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may
immediately revoke, modify,or suspend the use of such product or material within their jurisdiction. RER
reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control
Section that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code, including the High.Velocity Hurricane Zone.
DESCRIPTION:(Aluminum Single.HungWindov'.=
APPROVAL DOCUMENT:Drawing No.W03-53,titled"Aluminum Single Hung Windbiv
sheets 1 through 8 of 8,dated 07/14/03,with revision G dated 07/23/14,prepared by Al-Farooq Corporation,
signed and sealed by Javad Ahmad,P.E.,bearing the Miami-Dade County Product Control Revision stamp
with the Notice of Acceptance number and expiration date by the Miami-Dade County Product Control
Section.
MISSILE IMPACT RATING:Large and Small Missile Impact Reslgtailt
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state,
model/series, and following statement: "Miami-Dade County Product Control Approved", unless otherwise
noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been
no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change
in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement
of any product,for sales, advertising or any other purposes shall automatically terminate this NOA. Failure
to comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida; and
followed by the expiration date may be displayed in advertising Iiterature. If any portion of the NOA is
displayed,then it shall be done in its entirety.
INSPECTION: A copy of this entire-NOA shall- be provided to the unser by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA#13-1024.05 and consists of this page 1 and evidence pages E-1 and E,2,as well as
approval document mentioned above.
The submitted documentation was reviewed by Manuel Perez,R.E.
NOA No. 14-0903.05
MIAMI DA®uNrr 17 ExpirationDate: Febt uaiy 19,2019
d Approval Date: October 30,2014
�t7i �� Page 1
Innovative Window Contents,LLC
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
A. DRAWINGS
1. Manufacturer's die drawings and sections.
2. Drawing No.W03-53,titled"Aluminum Single Hung Window(L.M.I.)",sheets 1
through 8 of 8,dated 07/14/03,with revision G dated 07/23/14,prepared by Al-Farooq
Corporation,signed and sealed by Javad Ahmad, P.E. j
• i
B. TESTS
1. Test reports on: 1)Air Infiltration Test,per FBC,TAS 202-94
2)Uniform Static Air Pressure Test,Loading per FBC,TAS 202-94
3)Water Resistance Test,per FBC,TAS 292-94
4)Large Missile Impact Test,per FBC,TAS 201-94
5)Cyclic Wind Pressure Loading,per FBC,TAS 203-94
6)Force Entry Test,per FBC 2411 3.2.1 and TAS 202-94
along with marked-up drawings and installation diagram of an aluminum single hung
window,prepared by American Test Lab of South Florida,Test Report No.
ATLSF-0527.01-03,dated 06/12/03,signed and sealed by Henry Hattem,P.E.
(Submitted raider NOA#03-1201.02)
2. Test reports on: 1)Uniform Static Air Pressure Test,Loading per FBC,TAS 202-94
2)Large Missile Impact Test,per FBC,TAS 201-94
3)Cyclic Wind Pressure Loading,per FBC,TAS 203-94
along with marked-up drawings and installation diagram of an aluminum single hung
window,prepared by American Test Lab of South Florida,Test Report
No.ATLSF-1109.01-04,dated 01/25/05,signed and sealed by William R.Mehner,
P.E. . _-
(Submitted muler NOA#05-0215.04)
C. CALCULATIONS
1. Revised anchor verification calculations and structural analysis,complying with FBC-
2007,dated 10/28/08,updated to FBC-2010 on 01/12/12,and revised and updated on
07/30/14 to comply with FBC-5'h Edition(2014),prepared by Al-Farooq
Corporation,signed and sealed by Javad Ahmad,P.E.
(Submitted partly un(lerNOAIs#08-1210.03 and#13-1024.05)
2. Glazing complies with ASTM E1300-09.
D. QUALITY ASSURANCE
1. Miami-Dade Department of Regulatory and Economic Resources(RER)
"-Vf ru
l._/�' r
Manuel Fdrezl
Product Controf Ex iiner
NOA No:44=0903.05
Expiration Date: February 19,2039
Approval Date: October 30,2014
E-1
Innovative Window Concepts,LLC
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 11-0624.02 issued to E.I.DuPont DeNemours &*Co.,Inc.
for their"DuPont Sent yGlas®Interlayer"dated 08/25/11,expiring on 01/14/17.
2. Notice of Acceptance No. 13-0129.27 issued to E.I.DuPont DeNemours &Co.,Inc.
for their"DuPont Butacite®PVB Interlayer"dated 04/11/13,expiring on 12/11/16. i
3. Notice of Acceptance No. 14-0423.17 issued to Eastman Chemical Connpany(MA) '
for their"Saflex Clear and Color Glass Interlayers"dated 0619114,expiring on
05/21/16.
F. STATEMENTS
1. Statement letter of conformance, complying with FBC-5'h Edition (2014), and of no
fmancial interest, dated August 4,2014, issued by Al-Farooq Corporation, signed and
sealed by Javad Ahmad,P.E.
2. . Laboratory compliance letter for Test Report No.ATLSF-1109.01-04,issued by
American Test Lab of South Florida,dated 01/25/05,signed and sealed by William R.
Mehner,P.E.and Henry Hattem,P.E.
(Submitted under NOA#05-0215.04)
3. Proposal No. 14-0732 issued by the Product Control Section, dated July 1, 2014,
signed by Manuel Perez,P.E.
G. OTHER
1. Notice of Acceptance No. 13-1024.05 issued to Innovative Window Concepts,LLC
for their Aluminum Single Hung Window-L.M.I. approved on 12/26/13 and expiring
on 02/19/14.
Manuel Perm P.E.
Product Contro}/Exa} iner
NOA No.kt-ff903.05
Expiration Date: February 19,244-4--
Approval Date: October 30,2014
E-2
47 9/16" 47 9/16'
D.L.O.(FIX.LITE) D.L.O.(FIX. LITE) Ip
6'MAX. 6'MAX. n
HEAD/SILL HEAD/SILL Z
CORNERS 14'MAX. CORNERS 14'MAX. O
FALSE HUNTINSHEAD/SILL HEAD/SRL al
(SURFACE APPLIED) 1.4
OPTIONAL 3
A v
II II
A", II �yG m
g
�� N v
Q I /lJ
II O
a \n J II ii II • S a of F
30
6 �O I, L�1(yYLyp II 'ol > n c I O
(ty n J I II I 11 II' N Z �h
m S _Ci II II I C II II II Z V L�M�t
d
30�
V^V ' ' Lu Qzo
__-46 7/8' ---46 7/8' 3 z�K V
. D.L.O.(VENT) .o D.L.O.(VENT) `a w OL M m
so 1/8' 50 1/8' f O z
VENT WIDTHVENT WIDTH Z U
j H
HEAD/SILL ANCHORS NOT READ. 53 1/8' 'HE UL ANCHORS NOT REDD. 53 1/8- Z v
FOR YANDOWS'THAT REQUIRE WINDOW WIDTH FOR WINDOWS THAT REDUIRE / Z N G�0
62 PSF OR LESS 82 PSF OR LESS WINDOW WIDTH
DESIGN PRESSURES .DESIGN PRESSURES O
ALUMINUM SINGLE HUNG WINDOW (L.M.I.) UNEQUAL LITES (ORIEL TYPE) EQUAL LITES
DESIGN LOAD RATINGS FOR THESE WINDOWS TO BE AS PER
CHARTS SHOWN ON SHEETS 2 & 3.
TYPICAL ELEVATIONS '
APPROVAL APPLIES TO SINGLE.UNITS OR SIDE BY SIDE 'TESTED UNITS c"-F n
COMBINATIONS OF S.H./S.H. OR SINGLE HUNG WITH OTHER ° H I?
WINDOW TYPES IN MODULES OF TWO OR MORE WINDOWS USING
MIAMI-DADE COUNTY APPROVED MULLIONS IN BETWEEN. m 4
LOWER DESIGN PRESSURE FROM WINDOWS OR MULLION APPROVAL SSS s
WILL APPLY TO ENTIRE SYSTEM.
THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE c° ^^
REQUIREMENTS OF THE FLORIDA BUILDING CODE INCLUDING HIGH VELOCITY .D o g$o'
-gas
HURRICANE ZONE(HVH2). 6 o o ;LL°
WOOD BUCKS BY OTHERS;MUST BE ANCHORED PROPERLY TO TRANSFER O
LOADS TO THE STRUCTURE. q
ANCHORS SHALL BE AS LISTED,SPACED AS SHOWN ON DETAILS,ANCHORS
EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. THESE WINDOWS ARE RATED FOR LARGE MISSILE IMPACT. E"91 JAVAD At MAD PRODUCT REVISED S
SHUTTERS ARE NOT REQUIRED. Fu PE 170597 IVIL wtomplyLlgwilh111eNloride
ANCHORING OR LOADING CONDITIONS NOT SHOWN IN THESE DETAILS ARE C.AN 33 EuilJillItCada o -
NOT PART OF THIS APPROVAL. - Acceptant,No�4'09� '
E>.pimli,n Datc $ g
A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY, 7
ALL SHIMS TO BE HIGH IMPACT, NON-METALLIC AND NON-COMPRESSIBLE. Oy
Miami ade Product Can ole-. drawing no.
MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS,THAT 2014 CW03-53
COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE
REQUIREMENTS OF THE FLORIDA BUILDING CODE. " sheat of 8
UNEQUAL LITES WINDOWS
DESIGN LOAD CAPACITY-PSF WIDTH
FIANCE DIMS, SERIES 103D SERIES 1040 SERIES 1041 SERIES 1062 n
WIDTH HEIGHT EXT.(+)INT.(-) EXT.(+)INT.(-) EXT.(+)INT.(-) EXT.(+)INT.(-) Z
19-1/8' _65.0 72.5 62.0 62.0, 62.0 75.0 90.0 130.0
0
_ 24" 65.0_ 72.5 62,0 62.0 62.0 75.0 90.0 130.0 1
26-1/2" 65.0 72.5 62.0 62,0 62.0 75.0 90.0 130.0 /, C u
32•' 50-5/8' 66.0 72.5 62.0 6210 62.0 75.0 9D.O 130.0 kk
JT .(4) 65,0 72.5 62.0 62.0_ 62.0. 75.0 90.0__ 130,0 A
40' 65.0 72.5 62.0 62.0 62.0 75.0 90.0 130.0
48" 65.0 72.5 62.0 62.0 62,0 75.0 .90,0 130.0 �x 0 �eny1
53-1/8" 65,0 65,2 62.0 62.0 62.0 75.0 90.0 130.0 a �u M
19-I/8' 65.0 724 62.0 62.0 62.0 75.0 90.0 130.0 10
24' 65.0 72.5 62.0 62.0 62.0 75.0 90.0 130.0 0 l0
28-1/2' 65.0 .72.5 _62.0 82A 82.0 75.0 90.0 130.0 a 3
32' 63'. 65.0 72.5 62.0 62.0 62.0__ 75.0 90.0 130.0 GGG LL Y 0{
37' (5) 65.0 72.5 62.0 62.0 62.0 75.0 90.0 130.0 Z .I
40' - 62.0 62,0 62.0 75,0 90.0 130.0 ai YI iii��ill K'
O
48' - - 8210 82.0 62.0 75.0 90.0 130.0
53-1/8' - - 62.0 62.0 62.0 75.0 90.0 129.6 UNEQUAL LITES (ORIEL TYPE)
19-1/8' 63.0 72.5 _62.0 62.0 62.0 75.0 90.0 130.0 a J t
24" 65.0 72.5 62.0 62.0 62.0 75.0 90.0 130.0 w rn
28-1/2" 65.0 72.6 62.0 82.0 62.0 75.0 90.0 130.0 D O v
J2 .76' - - 620 62.0 .62,0 75.0 90.0 130.0 U Z Z !µ'a
J7" (6) - - 62.0 62.0 B2.0 75.0 90.0 130.0 O U to,v�
40' - - 62.0 62.0 62,0 75.0 90.0 130.0 O Z 4
48• - - 620 62.0 62.0: 75.0 90.0 130.0 Ci
53-1/8" - - 62.0 62.0 62.0 75,0 90.0 128.1 Z w 2
19-1/B" 65.0 724 62.0 .62.0 62.0 75.0 :90.0 130.0 Z K O la=2
24' 65.0 72.5 62.0. 82.0 82.0' ,75.0 90.0 130.0 o N w a D7
26-1/2' 84' - - 62.0 62.0 62.0 .75,0 90.0 .130.0 NOTE: SF o z-a-
'32' (7) - - 62.0 62.0 62.0 75:0 90.0 130.0 `-^ GLASS CAPACITIES ON THIS SHEEVARE
,37' - - 620. 62.0 . 620' -75.0 9D.D tW.0' BASED ON ASTM E1300-09 '(3,SEC. GUSTS) Zo
40' - '.62.0: 62.0 62.0' 75.0 90.0 t3D.D .-AND FLORIDA.BUILDING COMMISSION �, z N m
65.0 72.5 162.0 62.0 62.0' 75.0 90.0 130.0 DECLARATORY STATEMENT'DCA05-DEC-219 0
24' - 82.0 62.0 ..62.0',75.0 90.0 130.0
26-1/2" 96' - - 620 620 62.0 75.0 90.0 130.0 z
32' (8). - - 82.0' 62.062.0 75.0 90.0 130.0 Z
37' - - 62.0' 62.0 62.0 75.0 90.0 130.0
cR$ R
1/8"ANN.CLASS 3/16'ANN.CUSS _ 3/16°HEAT STREN'D GLASS' 3/16'HEAT STREN'D CLASS a s�s a g5
090'Intedoyer •090"Interlayer 090'Interloyer 090"Interlayer u g $
DuPont Sulacite PVB Saflex Clear And Color Gloss Sallex Clear And Color Glass DuPont SentgClas
By'E.I.DuPont Oe Nemours dt Co.,Inc.' By'Sostman Chemical Co.' By'Eastman Chemlcal Co.' 'By'E.i.DuPont Do Nemaure dr Co.,Inc.'
1/8"ANN.GLASS 3/16"ANN.GLASS 3/18'HEAT STREN'D GLASS 3/16"HEAT STREN'D GLASS g n
SILICONE i SILICONE z In SILICONE i$ SILICONE
3 m .DOW CORNING 995 DOW CORNING 995DOW CORNING 995 DOW CORNING 995 •u a c S o
'
w \c2 42 \ 42 rqj 42
n n hh ro hh m hh rye 4
'EnJAVAD.AHMAD
CML PRODUCT'REVISOD
gn n 53j
a �I, Fl.l.PE 70592 mcomplyingWith the Flodda c
0i OA.N. 538 Building Coda
5 45 45 .. 45 Acceplama No 4' 9 $ $
18 18 18 B ha Dnlc 9
13 , . o
SERIES 1030 SERIES 1040 SERIES 1041 SERIES 1082 S 2014 Mum'DadeProdu,i n or drawing no.
v llff..// W03-53
GLAZING OPTIONS
sheet 2 of 8
' EQUAL LITES WINDOWS 4.0 M
`. DESIGN LOAD.CAPACITY-PSF WIDTH
I
FI.ANGEDIETS. SERIES 1080 SERIES 1040 SERIES 1041 SERIES 1082 o
WIDTH HEIGHT E)(f.(+)IM.(-) EXi.(+)1M.(-} IXT.(+) 1M.(-) E7(T.(+) 1M.(-) 0
19-1/e' 65.0' 72.5_..62.0 62.0 65.0 75.0 _90_.0_ 130.0 r
24' 65.0. 72,5 62.0 62.0 65.0 75.0' 90.0 1.30.0 1"�
26-1/2" 65.0 72.5 62.0 62:0 65.0 75.0 90.0 130.0 �j' 3 V
32' 26" 65,0 72.5 62.0 62.0 65.0 75.0 90.0 130.0 a
37" (2) 65.0 72:5 62.0 62.0' 65.0 75.0 _90.0_ 130.0_
ao' 65.11 7z.5 sz.o -s2.o' 'es.o ' 7s.o .eo.o t3o.o
48' io
65.0 72.5 62 0 62.0 65.0 75.0 90.0 130.0 OpW�l
53-1/8• 65.0 72.5 62.0 62A - 65.0 75.0 90.0' 130.0
19-1/8' 65.0 72.5 62.0 62.0 65.0 75.0 90.0 130.0 O 4 a O
24• '65.0 72.5 62.0 62.0 65.0 75.0 90.0 130.0 Ip r
26-1/2• 65.0 72.5 62.0 62.0 65.0 75.0_ 90.0 130._0 Ip�li,5 y3J
32' 38-3/8' 65.0' 72.5 62.0 62.0 85.0 75.0 90.0 130.0 LL 2
37' (3) 65.0 72.5 62.0 620 65.0 75.0 90.0 130.0 G{
40' 65.0 72.5 62.0 62.0 65.0 75.0 90.0 130.0 F
48'. 65.0 72.5 62.0 82.0 65.0 75.0 90.0 130.0
53-1/8 65.0 72.5 62.0 62.0 65.0 75.0 90.0 130.0 EQUAL LITES o
19-1/8' 65.0 72.5 62A 62.0_ 65.0 75.0 90.0 130.0
24' 65.0 72.5 62.0 62.0 65.0 75.0 90.0 130.0 .o a '�
28-1/2' 85.0 72.5 62.0 62.0 65.0 75.0 90.0 130.0 W a
32' 50-5/e' 65.0 72.5 62.0 '62.0 65.0 75.0 90.0 130.0 z Z a'�^
37' (4) 85.0 72.5 62.0 82.0 85.0 .75.090.0 130.0 U{.1 M
40' 65.0_ 72.5 62.0 62.0. 65.0 75.0 90.0 130.0 z 3 Q
48' 65.0 72.5 62.0 62.0 65,0_ 75.0. 90.0130.0_ = p
53-1/8' 64.4 64.4 62.0 62.0' 65.0 75.0 90.0 130.0
19-1/1' 65.0 72.5 62.0 62.0. -65.0 75.0 96.0 130.0 Z 3 O H
24' 65.0 72.5'.62.0 62.0 65.0 75.0" 90.0 130.0 N 6.a)a
26-1/2• 65.0 72.5 82.0 62.0 85.0 75.0'1 90.0 I130.0 = at
U z m
32' 63' 65.0. 72.5. 62.0 62.0 65.0 75.0 90.0 130.0 z
37' (5) .65.0 72.5 62.0 62.0 65.0 75.0 90.0 130.0 j OZ o
40' 85.0 . 72.5 62.0 62.0 65.0 75.0 90.0 130.0 Z N m
48' 64.9 64.9 62.0 62.0 85.0 75.0 90.0 1.30.0 O
53-1/8' 56.0 56.0 '620 62.0. 65.0 75.0 90.0 121.8 m
19-1/8• 65.0' 72.5 62.0 62.0 65.0 75.0 90.0 130.0
24' 65.0 72.5 62.0 62.0 65.0 75.0 90.0' 130.0
26-1/2" 65.0' 72.5 62.0 62.0 65.0 75.0 90.0 130.0 a g u A
32' 76' kO72
62.0 62.0 65.0 75.0 90.0 130.0
o 0
37' (8) 62.0 82.0 65.0 75.0 80.0 130.0 = q fffJJJ
40' 62.0 62.0 65,0 75.0 90.0 130.0 a
48' 62.0 62.0 65.0 75.0 90.0 130.0 w
SS-1/8' 62.0 62.0 65.0 75.0 90.0 111.7 0 NOTE:
19-1/8" 62.0 62.0 65.0 75.0 90.0 130.o d GLASS CAPACITIES ON THIS SHEET ARE
24" 82.0 62.11 15,11 75.0 90.0 130,0 BASED ON ASTM E1300-09 (3 SEC. GUSTS) a,
411 Ic
26-1/2" 65.0 72.5 62.0 62.0 65.0 75.0 90.0 130.0 AND FLORIDA BUILDING COMMISSIbN DECLARATORY STATEMENT DCA05-DEC-219
32" 84' 65.0 72.5 62.0 62.0 65.0 75.0 90.0 130.0 p -
37• (7) 85.0 72.5 62.0 62.0 65.0 75.0 90.0 130.0 =
40' - - 82.0 62.0 65.0 75.0 90.0 130.0 N '
48' - - 62.0 62.0 65.0 75.0 90.0 130.0 ` Engr..UYAD AHMAD - c
CML PRODUCTREVISED
19-1/8' 65.0 72.5 82.0 62.0 65.0 75.0 _90.0 130.0 w FLA PE/70592 •s-,plyingwith lho Flarld9 0
'GAN.'.5533 Duilding Code n
24" 65.0 72.5 62.0 82.0 B5.0 75.0 90.0 130.0 Acccplance No
26-1/2" 96" 65.0 72.5 62.0 62.0 65.0 75.0 90.0 130.0 Z 8r rnllon Dnta 9 4 '� 0 5
32' (8) 65.0 72.5 62.0 02.0 65.0 75.0 90.0 130.0
37' - - 62.0 82.0 85.0 75A 90.0 130.0 0 A82
O�Adfawing no.
40" - - 62.0 62.0 65,0 75.0 90.0 130.0 . 9 , W03-53
sheat 3 of 8
TYPICAL ANCHORSTYPICAL ANCHORS
WOOD BUCK ��
113YI SEE ELEV.FOR PACING 'SEE ELEV.FOR SPACING
R S1BY
t WOOD DUCK,
[%!a
0 "
O O ,A a p 14
.SLOPED 1 i FLAT 45 II II 8
° M
nu a
4 h 27 46 II I' 27 0 Q 4
46 II II II I' Q�t0 a�'
'I 'I LL z�2 1pJx1
O W el F
J L
I I
N
II II 42 v �
II II 15 m
II II 28 OPTIONAL TO
II ,, SPRING LATCH
Z 2
3
Z � M
4 :3Ooh'
!E ow
Son
I
a m
W s 0
0 0
Z 4 �'
16 q II J
� II II O
I, II
1 'I II 1
U o
_ J
I I 4
10
25 a 1; P-
II II N
IB I, II i {I
I I
23
O 7 30 SEALANT: n o g g
ALL JOINTS AND FRAME CONNECTIONS SEALED WITH '9 o e 4
SCHNEE MOREHEAD SEAM SEALER SM5504.
Engr;JAYAD AHIAAO r
PROD
CIVIL IJCT'RQVISQb
FIA.PE 0 70592 ne complying with lho Pimidn• r
Q. CAN.7538 �11,21lo
drawing no.
','.o.t.'.••c•.. :9 ~ TYPICAL ANCHORS W03-53]
SEE ELEV.FOR SPACING '
sheet 4 of 8
TYPICAL ANCHORS \ U
ICK I SEE ELEV.FOR SPACING ' METAL TYPICAL ANCHORS 2BY`N[O\OD BUCK
Yf00D BUCK STRUCTURE SEE ELEV.FOR SPACING OR 0D STRU TORE M
n e •a a MIAMI-DADE COUNTY.APPROVE
eD
" MULLION&MULLION ANCHORS O. p:
CL
SEE SEPARATE NOA
cy
TYPICAL ANCHORS TYPICAL ANCHORS C a 6
SEE ELEV.FOR SPACING SEE ELEV.'FOR SPACING C)08
a i
TYPICAL ANCHORS u1
IBY SEE ELEV.FOR SPACING METAL TYPICAL ANCHORS �� 0 M
2 l 00D BUCK ZZ l�'
W000•SUCH.. STRUCTURE SEE ELEV.FOR SPACING OR Stu
RE W 2,
o e I' MIAMI-DADE COUNTY APPROVED
MULLION&MULLION ANCHORS 0
e.a I SEE SEPARATE NOA I ^ U a
jj
Ln 0
It 2 0 N
3 Z a
4
N z U M
\ \ TYPICAL ANCHORS \ 5 3 p CJ
CAL ANCHORS SEE,ELEV.FOR SPACING =
"SEE•ELEV.TYPI R SPACING
UQQ
N Oa Wm a
UOQ
TYPICAL ANCHORS: SEE ELEV.FOR SPACING 0 o a
WOOD BUCKS AND.METAL STRUCTURE NOT BY I.W.0
1•/4" DIA:.VLTRACON BY'ELCO' (Fub177 KSI,Fy.-I55 K51). .MUST SUSTAIN.LOADS IMPOSED BY GLAZING SYSTEM Z N m
INTO 28Y WOOD.BUCKS OR WOOD:STRUCTURES AND TRANSFER THEM TO THE BUILDING STRUCTURE.
1-1/2" MIN. PENETRATION'INTO WOOD
THRU 1B BUCKS INTO'CONC. OR MASONRY
1-1/4" MIN.'EMBED INTO CONC. OR MASONRY,
DIRECTLY INTO'CONC. OR MASONRY c R
1-1/4" MIN. EMBED INTO CONC. OR MASONRY 0 B
•f 14 SMS'OR SELF DRILLING SCQEWS (GRADE 2 CRS) 'o
INTO METAL STRUCTURES o
STEEL : 12 GA. MIN. (Fy — 36 KSI MIN.)
ALUMINUM : 1/B" THK. MIN. (6063—T5 MIN.) n
(STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED)
N 6
#12 SMS98-SELF DRILLING SCREWS $ .
• o
INTO MIAMI—DADE COUNTY APPROVED MULLIONS (MIN. THK. _ .090")
(NO SHIM SPACE)
F.ngr.JAVAO AHM40 PRODUCT REVISED
I A DQC DISTANCE CML mcomplyhigwith the Plodda
--r3-��. E FLA PE/70SB2 0
INTO CONCRETE AND MASONRY = 2-1/2" MIN. CAN, 5M Ac 2.1.
No�
INTO WOOD STRUCTURE = 1" MIN. mltonDaleQ
�I
INTO METAL STRUCTURE = 3/4" MIN. E.�yjLi/ o
' Mte�Dedo PToducl nt drawing no.
WOOD-AT HEAD, SILL OR JAMBS SG.-0.55 MIN,
WO —5,3
CONCRETE AT HEAD,.SILL OR JAMBS YC a 3000 PSI MIN. (SE 9 2OtA Ljl
C790 HOLLOW/FILLED BLOCK AT JAMBS Pm = 2000 PSI MIN. C.hae7t5=- B
MIAITEM NO. PART NO. QUANTITY DESCRIPTION MATERIAL.' EIANF./SUPPMER/REMARKS 4,u v
APPROVROVEO MULLIOCOUNTY
TYPICAL ANCHORS 1 021-029 �1 FRAME HEAD(SLOPED) _ 8063-T6 MCH ALUM.
SEE SEPARATE NQA SEE ELEV.FOR'SPACING
1A 021-006 1 _ FRAME HEAD(FLAT) 6063-TS MCH ALUM. o
2 021-002 1 FRAME SILL 6063-T6 MCH ALUM,
3 021-005 _ 2 FRAME JAMB 6083-T6 MCH ALUM.
4 .022-007 1 MTO.RAIL 6063-T5 MCH ALUM.
G
6 T 022-004 1 VENT TOP RAIL - 6083-T5. MCH ALUM. O 0. if U
7 022-001 1 VENT BOMOM RAIL 6063-T5 MCH ALUM. IL
B -021-003 2 VENT S1°E RAIL 6063-T5' MCH ALUM_. ^�
18 021-011 4/LITE GLAZING BEAD 6063-T5 MCH ALUM. 8 n
VVV� M
18A 021-012 4/LITE CUBING BEAD_ 6063-T5, ARCH ALUM. 0O '
23 021-000 2/VENT SNAP LATCH 2 O 3-LG) 6063-T5 MCH ALUM., O 0Q
24 025-000 2 ULTRA UFT BALANCE CALDWELL MFG 0 y
24A 024-000 2 BLOCK&TACKLE BALANCE BSI E7;
------- ------ 25 006-001 2 SPRING ST/ST IND.SPRING GZf��ynyj-
26 004-005 - UEK BRACKET STEEL CALDWELL MFG Q a N F
'WINDOW WIDTH VRNbOW WIDTH 27 010-001 - SASH STOP RIGID VINYL MASTER TOOL •/ 1-
O
28 004-002 - .SWEEP LOCK O 7'FROM ENDS _METAL SULLIVAN&ASSOC. = U
29 016-001 AS REOD. FIN SEAL WOOL PILE ULTRA FAB
� n
JO 023-001 - FILLED BULB VINYL AMESBURY
TYPICAL ANCHORS ttPICA1 ANCHORS 31 015-009 - CHIMNEY PLUG .CLOSED CELL FRANK LOWE RUBBR 3 .>
SEE ELEV.FOR SPACING O
SEE ELEV.FOR SPACING 3,T 008-014 AS READ. BBX1 PHPH SMS ST/ST O
VENT WIDTH z Z
34 008-031 2/ENO 010X1 PHPH SMS ST/ST 3
O. cl
D.L.OPG. 1/4°MAX. 37 012-001 - SEAM SEALER SM5504 ACRYLIC' SCHNEE MOREHEAD Z U>M a
49 SHIM
/SHIM 50 39 008-010 = JbXI/2 UCFHPH SATS ST/ST —_� O 3 p
= O1Wa�
B 29 40' 008-017 /8X1 1/4 FHPH SMS ST/ST w Z F=o
. 24 _ 42 015-001 IS'REQD. BULB VINYL VINYL MASTER TOOL C9 .g V e"ri
42A 015-007 AS READ, WEDGE CASKET VINYL - inn d m m
45 015-006 - .0.150'SPACER .VINYL FRANK LOWE RUBBR U zo
--=_ ------_-_ -_ ___ _- 45A '015-004 - 1/16 X:400 SPACER _ VINYL FRANK LOWE RUBBR ? j�
48 012-004 - DOW 985 SILICONE DOW CORNING J Z o O r;
18 y' 49 010-010 - SASH GUIDE TOP RIGID PVB ±_&M PLASTICS Q Z N m F
50 010-011 - SASH GUIDE BOT ' 'RIGID PV8 M&M PLASTICS
WOOD B K - --- -- - - --_- - - - - - - -- --- .4 51 '008-002 - 16%1/2 FHPH SMS ST/5T
R
WOOD STRUCTU� _ 55 003-001' AS READ. ,ROLL FORM SCREEN FRAME ALUMINUM FLORIDA SCREEN
-----SCREEN OPTIONAL ---- o
40
3 EXTERIOR 7 e WOOD BUCKS
D.L.OPG. 3
WINDOW WIDTH
TYPICAL ANCHORS '• n r.
1/4-MAXMSEE ELEV.FOR SPACING o
/ O'od6
SHIM OP110NA1 TOULTRAUFT BALANCEEner;JAVAD AIMAD" PRODUCT REVISEDCAL mmplying with Lha Piorida
CAPN. 538592 Building CodeAcceplanco l METALI DteSTRUCTURE -------__ ❑y
IAimr' ado Pr uclContro(�T drowing no.
_-_-_--_ 6A(P
2014' J W03-53
--SCREEN OPT. sheot s o1 $
.406 � .077
'..297-y - 3.189- 1�
i � � F+-A7a � e�
.094 .500 d..I }''305 3
.909, .500 1.000 I 0 .�
i.e9s I L_
1.157- 1,68] }' 1
9 5 062 1.062 Ofi2 Q a
-!. NP. .
3:062 NP. C' U
062 7'750 1.405 Q.
.070 Tom•
33",-
.457 . Q:6' •u
• 3.239 � �,
1 FRAME HEAD(SLOPED) 1A FRAME HEAD (FLAT)
�r.2a5-W t,ao9 4 FIXED MEETING RAIL
-2.046-
1.1041
.048 1.104 .750 -
3.095
.062 0]B .562 v J r
typ, 970 1.467 .062 3 v
It ItFF
7 NP. 2.467
i--1.795
.t.000 V ro 4
.075
070 a U
3 FRAME JAMB 7.03 K
B VENT TOP RAIL V 3 a�m
. 3,304 Oz
2.293
O
J71
1.J34
2.686 2.401 1.000
.078 tttt
3.436 265
.494 2.670 $ .
..535 1.715 .0e2
7YP
NP
---�' . 1.000 .050 N z 5
09J 1.104
3.114 .903 Fn w
2 FRAME SILL 7 VENT BOTTOM RAIL
. to GLAZING BEAD
1.010 .875'
.415
q L
B F.ngr.JPE AN50 S
-�. - cmL wtopucrizsvtssu n. \
,'-' 4,415
.303 F1A.PE 0592d1.094 844 •� .970 1• CAN. DulldingCade.936 .078 ._TYP. - P p{att pate.625 BY drowi630 1 000 3 •ktt m do NCo tray 8
2014 // W03-53
23 LATCH 80 VENT SIDE,RAIL GLAZING BEAD sh0ol 7 of $ '
- - — - - - -
u
N NN F
o u o
4y •\ \
�d b
o�o€hoe •' � o
a date: DY—ta-0,t
revisions: ALUMINUM'SINGLE HUNG WINDOW LIVI— a
T `L c no a e escri on ) AL FAROOQ CORPORATION
ENGINEERS&PRODUCE DEVELOPMENT S
m W / INNOVATNE WINDOW CONCEPTS, LLC s23ssW a�AVE T
2005 CORPORATE DRIVE MIAMI,FLORIDA33174
CT X10 BOYNTON BEACH, FL 33426 TEL
W e enw. a°E�.0 va°are°m z°ta Tec
TEL(561)493-2303 FAX 493-2302
305)26481W FAX(3o�267a C
COMP—ANL\W03-531WC