HomeMy WebLinkAboutEngineering PAUL NVELCH INC. Mechanical * Electrical * Civil Engineering 1984 S.W.Biltmore St. Suite#1 14 Port Saint Lucie,FL 34984 Phone(772) 785 -9888 Email pwelchinc@aol.com December 17,2015 F map— Re.: Door Replacement Y, 9803 S. Ocean Dr. A4007 r Jensen Beach, FL To Whom It May Concern: Our office has calculated the required design pressure in accordance with ASCE 7-10 for a replacement of the doors at the above referenced address. Wind speed: Vwt: 165raph,V,,,d: 124 mph Exposure: D Enclosure Type: Enclosed Door Size: 36" X 80" Solid Core Door Quantity of Doors: I Location: Zone 5 (Per Attached Sketch) Required Design Pressure(Zone 5): +45.6/-60.8 PSF Worst Case Door to be installed shall be equal to,or exceed the required design pressures as listed above. All installations shall be in accordance with FBC 2014 and manufacturer's installation instructions. Proposed Door: Plastpro Inc. / Nanya Plastic Corp. Fiberglass Door FL#15187.1 (+65.0/-65.0PSF). Thank you for your attention to this matter. Submitted by: PAUL WELCH IN Paul Welch, P.E. Reg.No 29945 Attached: Product Approval Affid. Area of Work Plan S PAUL WELCH INC. Mechanical * Electrical * Civil Engineering 1984 S.W.Biltmore St. Suite#114 Port Saint Lucie, FL 34984 Phone(772)785 - 9888 Email pwelchinc@aol.com Door Replacement 9803 S. Ocean Dr. Jensen Beach, FL A 25 27 19 C N2 (24) - -_ 38 6 EXISTING STRUCTURE 4 6 4 6 13 CN3 19 27 (130) 10 4 OA 36"WIDE X 80"HIGH OUTSWING DOOR AREA OF WORK PLAN nts... NORTH —> Paul Welch,P.E. / Reg.No 29945 December 17,2015 Planning & Development Services Department Building & Regulations Division Product Review Affidavit Building Permit# Owners Name I Ue ft bt-b AA4 JAI+ - Applicant: 960'-:5 t, k1{.dEA J DOP) Product Opening Design Product Rated Manufacturer Model Number Product Approval Gies Method of Attachment Pressures Desid"pressure Nu rTvoe Windom N 1A Mullions Fined Glass Slock{Mass Skylights Sliding Blass Doors SvWng Ty Doors +r45V5.0 -U50 E S P,Ca f,G. DUT fM/S187,! 14 '14-" I'll M{!0, fgb� Qe,005 Ar French Doors A Y (op K 7( 5 Garaus Doors Hurricane Protection Root ventiletlon Roofing Materiel I have reviewed the above components or cladding and i have approved their use in this str re. These products provide adequate resistance to the wind toads and forces specified by current code provisions. Name: PAUL WELCH P.E. Signature: — Design Prof. I PAUL WELCH P.E. Cert.No. 2"45 Date: ,DEC 1 7 2015