HomeMy WebLinkAboutInspection Docs �� l �,- ��� fsl (
M L Engineering Inc.
2030-37 Ih Avenue
Vero Beach,Florida 32960
Phone: (772)569-1257
Fax:(772)569-4041
November 24, 2015
Mr. Carl Peterson, Building Official
St. Lucie County Building Department
2300 Virginia Ave
Fort Pierce,Florida.34982
Re: Fiberglass Supply Depot—Re Roof
2550 North US Highway 1
Fort Pierce, Florida
SLC Permit No. 12511-0202
Engineer's Permit No. 15-238
Dear Mr. Peterson:
A roof pull test was performed in the existing 5/8"thick plywood roof sheathing using a
Carlisle HP-X connector by OMG Roofing Products as per the product approval note 11.
Based on the results of the test, the substrate exceeds the capacities required by the
Product Approval and we have approved the fastening system.
Respectfully,
i hael Lue-T E-
'consulting`Fngineer
En.cl: Pull test results
i
- RECEIV7D NON 2410i5'
F" 0 0 F ( �4
153 90VILtS ROAD
t;aKi.'t1`a,iii A 01001
43 7E9(125"
gc?3;•t,3u3t;4O
=tax:413•799.106
t-��11i1.t3L'f FiiST,tO„1 .
1
11/17/2015
Eric Black
MB.Enterprises
540 2nd St. SW
Vero Beach;FL
UNITED STATES
Re:Fiberglass Depot
Dear Eric:
I have enclosed the Job Report Number 11342 from the job referenced above. The report was recorded by Luke
Turner, OMG Field Sales Representative.
OMG is interested in your feedback on our services. Please visit wwwc.)malistens.com to take a brief, 2-3
minute survey to help us understand how we did on this project, and more importantly, anything we can do
better next time. We value your time and input, and thank you in advance for your participation.
If you have any further questions,please feel free to call.
Sincerely,
rz t?F HEWED,NO E3 REJECTEO
,r`{ irXti EPTIONS TAKEN ® RESUIst'AT
Ll
dREVIEWED ANOTED El DO NOT RESU3M1T
SUn ` SPECIFIED P
Andy Cleveland is only for gs'ndral conformance with the design
OMG Technical SupportLead ntet,t of �•: pro;ecz Gn=? comp' nce .xith the informa?+on
c ;h
tom."V3!t in GL9 cotliract documents, t!:ny i n �`rJn t5
sul3 ect to the requirements of the pl as an:f; :=ccficatcons.
CC: Contractor is responsible, for dimsns:o�cs which shall by
Luke Turner OMG mnfrmed and coordinated at the jobsite,fabrication processes,
tecf'(niques of construction, coordination of all w k with
Miser vad and the satisfactory performance_ in a
rrc ordance
n tiap a uments. N //Al
Attn: pytyE i 6Y
EricBlack2011@Gmail.com; N.L.Engineering,Inc.
CoTmAing Engineer
Vero Bach;Florida
Enc:
None
R---t-1,J—'6-- 11 ld'7 nage 1 of 4
PuN Test Report
Job Name: Fiberglass Depot Report Number: 11342
Job Location:Fort Pierce,FL Test Date: 11/17/2015
Ambient Temperature: 83°F Building Height: 12'
Tester Manufacturer:DMD Force-2000 Max Cap of Tester: 2000
Test Witnessed By: Eric Black(MB Enterprises)
Ground Roughness: C Roof Area: 2,588 sq. ft.
Test Performed By: Luke Turner Existing Roof System: Re-Roof
Test Cut Area Repaired By: Eric Black(MB Thickness of Existing Roof. .25'
Enterprises)
Fasteners Tested: Carlisle.HP-X New System Manufacturer: Carlisle
Roof Cover Type:M/A Single Ply
New Insulation Manufacturer: Carlisle
Insulation Type: ISO
Insulation Thickness: 4.5"
Deck Type Thickness
Wood-plywood 5/8"
Disclaimer: Manufacturer's installation requirements shall be
followed when using any of the tested fasteners or adhesives.
Neither the technician performing the pullout tests,nor his/her
company is responsible for the waterproofing integrity of the
repairs.This test report does not certify the structural integrity of
the roof deck.
Report Number 11342 page 2 of 4
Test ResuRs
Job Name: Fiberglass Depot
Test Results lbs Fastener'bested Penetration Bit Diameter Comments
Location No.
1 1117 Carlisle HP-X 1"
2 574 Carlisle HP-X 1"
3 427 Carlisle HP-X 1"
4 431 Carlisle HP-X 1"
5 725 Carlisle HP-X 1"
6 857 Carlisle HP-X 1"
7 895 Carlisle HP-X 1"
8 921 Carlisle HP-X 1"
9 487 Carlisle HP-X 1"
10 517 Carlisle HP-X 1"
Pull Test Comments:
This pull test was requested by Eric Black with MB Enterprises.
Eric was onsite to witness and repair the roof.
There is a tapered ISO system on this job from 1/2"to 4.5"
i
Report Number 11342 page 3 of 4
` DeP®'t
?,00 eat ,be�
s.
�un'ber 11342
Report