Loading...
HomeMy WebLinkAboutEngineering Advanced Architecture & Planning LLC Architect & Planning 4929 S. Indian River Drive Ft. Pierce, FL 34982 (772)631-5709 Wind Loads for Sliding Glass Door Certification: December 18, 2015 Bill Laprade Glass Professionals Stuart,Florida Cell: 772-283-0616 Email: glassprofessionals@gmail.com Project: Two Sliding Existing Glass Door Replacements, 89' High: Tyler Residence,Admiral Condo's, 8750 S. Ocean Drive Unit 1033 Jensen Beach,FL 34957 Dear Mr. Laprade: Please know a wind load analysis was completed for the following: 1. Two sliding glass doors,NOA 14-0128.11 by PGT Industries, Series 770,Aluminum SGD with reinforcements, glass Type G4 or G4A, with minimum sill riser of 4.0"and Large and Small Missile Impact rated. Allowable Design pressure of+90.0 psf and— 110.0 psf. Using the ASCE7-10 to calculate the applied wind loads for the sliding glass door replacements,the following parameters were used: Window& Sliding Glass Doors height less than 90 feet; Exposure D; Wind speed 170 mph;Enclosed Structure; Category II, Wind Zones 4 &5; When taking into account the external and internal pressure coefficients and adjustments per the ASCE7-10,the resulting and governing and most severe applied wind pressure comes to+82.3 psf/-96.4 psf. With all systems installed per the above noted NOA,the allowable pressures all exceed the applied wind loads in this application, and is therefore acceptable to this office. If you have any questions,please contact me at a P - Thank you, , ADVANCED, •Q%%,-rARCHirECT PLANNING LRC$ Raymond Ch1 2573 ,•U B.arch.Sc.,M.ar '�'• .'t�, AIA,NCARB, ARG�\� Lic.#: AA26002573 Page 1 of 2 d 1�of 1 Find I Next t' NFRC Report c+PROTECTION&S'it1ENG1"H PO Number: Herb&Grace Tyler 2 Job Name: Herb&Grace Tyler 2 www.pgtindustries.com Job Address: Line#Item Description ` Quantity —_ Location (1.1 SGD770HP SGD SERIES 770 HP Ordered:1 I{(001)— 191x95 EB/L4 TLIG G 4/2 BY SN S 2131C I Unit Width::191.375 Unit Height::95.875 II Send Door:Complete Frame Color:Bronze Glass Type:Laminated Insulating Glass Make-Up:3/16"Tmp-7/16"Tmp/Tmp ! Glass Color:Clear GlazingDescription:"'I LIG(3/16 Tmp-3/8 air-7/16 Tmp/Tmp i Interlayer Type:SGP.090 (PVB Lami" IIII Inboard Color:CUCL ;Low-E:SolarControl LowE2 Configuration::BP (Argon Gas:Yes E Stacking:Standard Stack Panels&Tracks:4 Panel/2 Track {Panel Configuration:OXXO Door Type:Bypass +Sill Riser Type:Narrow Sill Riser Height:4" Screen Rail Qty:1 Muntin type:No Grid ' Screen Type:1816 Charcoal Screen Panels:Box Screen i Astragal Orientation:Astragal Box Out ;Screen Quantity:2 Primary Lock Type:Mortise Lock Panel Type:RILIDIP Panel 3(OSLI):Raised Interior&Exterior Panel 2(OSLI):Raised Interior&Exterior Primary Lock Location:39 Handle Color:Black X-Panel Rollers:Stainless Steel Tandem I Secondary Lock Type:None Panel Reinforcement:Aluminum Heavy-Duty Astragal:Yes i O-Panel Rollers:Stainless Steel Tandem Heavy-Duty Stiles:Yes Certification:Miami-Dade NOA(in HVHZ) Which NOA:15-0106.09 SM(exp.3/24/2020) Substrate:Concrete AnchorType:1/4"Elco Ultracon # FPANumber.FL251 Water:13.5000 i Calculated DP+;90.0000 Calculated DP:130.0000 �Pt�#2�Lt3S1riSC•-�0:2000A �kt�t,'�L�ab�1�11=FactaT�B[65Q0� NFRC COGVT(Use for Turtle Code)::0.3700 NFRC Label:VT:0.2700 j NFRC CondResistance:17_0000 — – NFRC Energy Star Zone:Does Not Qualify 2.1 iSGD770HP SGD SERIES 770 HP Ordered:1 (0 02) 1144x95 EB/L4 TLIG G 3/2 BY RN S 1131C Unit Width::144.750 i Unit Height::95.500 1 Send Door:Complete I Frame Color:Bronze Glass Type:Laminated Insulating Glass Make-Up:3/16"Tmp-7/16"Tmp/Tmp I j Glass Color:Clear I'GlazingDescription:"1""LIG(3/16 Tmp-3/8 air-7/16 Tmp/Tmp I Interlayer Type:SGP.090 i PVB Lami" Inboard Color:CL/CL (Low-E:Solarcontrol LowE2 I Configuration::BP ;Argon Gas:Yes Stacking:Reverse Stack Panels&Tracks:3 Panel/2 Track Panel Configuration:OXX Door Type:Bypass j Sill Riser Type:Narrow Sill Riser Height:4" Screen Rail Qty:1 Muntin type:No Grid Screen Type:1816 Charcoal I Screen Panels:Box Screen Astragal Orientation:Astragal Box In Screen Quantity:1 Primary Lock Type:Mortise Lock Panel Type:SIMIK Panel 3(OSLI):Raised Interior&Exterior Panel 2(OSLI):Raised Interior&Exterior Primary Lock Location:39 Handle Color:Black i X-Panel Rollers:Stainless Steel Tandem 'Secondary Lock Type:None 'Panel Reinforcement:Aluminum Heavy-Duty Astragal:Yes O-Panel Rollers:Stainless Steel Tandem Heavy-Duty Stiles:Yes Certification:Miami-Dade NOA(in HVHZ) Which NOA:15-0106.09 SM(exp.3/24/2020) Substrate:Concrete AnchorType:1/4"Elco Ultracon FPANumber:FL251 Water:13.5000 Calculated DP+:90.0000 i Calculated DP-:130.0000 http://www.exoquote.com/exoquote/Reporting/(S(kxubO 1 xsvhisoceg 13 slupht))/ExoRepor... 12/16/2015 Page 2 of 2 r � Rf�dlarb�l�slillf��€Z001� '4�r�aber�l-acc000� k I j 'NFRC COGVT(Use for Turtle Code)::0.3700 i'NFRC Label:VT:0.2700 NFRC CondResistance:17.0000 p NFRC Energy Star Zone:Does Not Qualify s I ---- ( - 3.1 Engineering Fee Engineering Fee Ordered:1 I � I j 4.1 Permit Pull Permit --- Ordered:1 5.1 Remove&Replace Sliding Glass Doors Remove— Ordered:1 &Replace Sliding Glass Doors I Print Date 12/16/2015 Page 1 of 1 http://www.exoquote.com/exoquote/Reporting/(S(kxub0l xsvhisoceg 13 slupht))/ExoRepor... U/16/2015