HomeMy WebLinkAboutEngineering Advanced Architecture & Planning LLC
Architect & Planning
4929 S. Indian River Drive
Ft. Pierce, FL 34982 (772)631-5709
Wind Loads for Sliding Glass Door Certification:
December 18, 2015
Bill Laprade
Glass Professionals
Stuart,Florida
Cell: 772-283-0616
Email: glassprofessionals@gmail.com
Project: Two Sliding Existing Glass Door Replacements, 89' High:
Tyler Residence,Admiral Condo's, 8750 S. Ocean Drive Unit 1033 Jensen Beach,FL 34957
Dear Mr. Laprade:
Please know a wind load analysis was completed for the following:
1. Two sliding glass doors,NOA 14-0128.11 by PGT Industries, Series 770,Aluminum SGD with
reinforcements, glass Type G4 or G4A, with minimum sill riser of 4.0"and Large and Small Missile
Impact rated. Allowable Design pressure of+90.0 psf and— 110.0 psf.
Using the ASCE7-10 to calculate the applied wind loads for the sliding glass door replacements,the following
parameters were used:
Window& Sliding Glass Doors height less than 90 feet;
Exposure D; Wind speed 170 mph;Enclosed Structure; Category II, Wind Zones 4 &5;
When taking into account the external and internal pressure coefficients and adjustments per the ASCE7-10,the
resulting and governing and most severe applied wind pressure comes to+82.3 psf/-96.4 psf.
With all systems installed per the above noted NOA,the allowable pressures all exceed the applied wind loads
in this application, and is therefore acceptable to this office.
If you have any questions,please contact me at a
P -
Thank you, , ADVANCED, •Q%%,-rARCHirECT
PLANNING LRC$
Raymond Ch1 2573 ,•U
B.arch.Sc.,M.ar '�'• .'t�,
AIA,NCARB, ARG�\�
Lic.#: AA26002573
Page 1 of 2
d 1�of 1 Find I Next t'
NFRC Report
c+PROTECTION&S'it1ENG1"H
PO Number: Herb&Grace Tyler 2
Job Name: Herb&Grace Tyler 2
www.pgtindustries.com Job Address:
Line#Item Description ` Quantity —_ Location
(1.1 SGD770HP SGD SERIES 770 HP Ordered:1
I{(001)— 191x95 EB/L4 TLIG G 4/2 BY SN S 2131C I
Unit Width::191.375 Unit Height::95.875
II Send Door:Complete Frame Color:Bronze
Glass Type:Laminated Insulating Glass Make-Up:3/16"Tmp-7/16"Tmp/Tmp
! Glass Color:Clear GlazingDescription:"'I LIG(3/16 Tmp-3/8 air-7/16 Tmp/Tmp
i Interlayer Type:SGP.090 (PVB Lami"
IIII Inboard Color:CUCL ;Low-E:SolarControl LowE2
Configuration::BP (Argon Gas:Yes E
Stacking:Standard Stack Panels&Tracks:4 Panel/2 Track
{Panel Configuration:OXXO Door Type:Bypass
+Sill Riser Type:Narrow Sill Riser Height:4"
Screen Rail Qty:1 Muntin type:No Grid
' Screen Type:1816 Charcoal Screen Panels:Box Screen
i Astragal Orientation:Astragal Box Out ;Screen Quantity:2
Primary Lock Type:Mortise Lock Panel Type:RILIDIP
Panel 3(OSLI):Raised Interior&Exterior Panel 2(OSLI):Raised Interior&Exterior
Primary Lock Location:39 Handle Color:Black
X-Panel Rollers:Stainless Steel Tandem I Secondary Lock Type:None
Panel Reinforcement:Aluminum Heavy-Duty Astragal:Yes
i O-Panel Rollers:Stainless Steel Tandem Heavy-Duty Stiles:Yes
Certification:Miami-Dade NOA(in HVHZ) Which NOA:15-0106.09 SM(exp.3/24/2020)
Substrate:Concrete AnchorType:1/4"Elco Ultracon #
FPANumber.FL251 Water:13.5000
i Calculated DP+;90.0000 Calculated DP:130.0000
�Pt�#2�Lt3S1riSC•-�0:2000A �kt�t,'�L�ab�1�11=FactaT�B[65Q0�
NFRC COGVT(Use for Turtle Code)::0.3700 NFRC Label:VT:0.2700 j
NFRC CondResistance:17_0000 — – NFRC Energy Star Zone:Does Not Qualify
2.1 iSGD770HP SGD SERIES 770 HP Ordered:1
(0 02) 1144x95 EB/L4 TLIG G 3/2 BY RN S 1131C
Unit Width::144.750 i Unit Height::95.500 1
Send Door:Complete I Frame Color:Bronze
Glass Type:Laminated Insulating Glass Make-Up:3/16"Tmp-7/16"Tmp/Tmp I
j Glass Color:Clear I'GlazingDescription:"1""LIG(3/16 Tmp-3/8 air-7/16 Tmp/Tmp
I Interlayer Type:SGP.090 i PVB Lami"
Inboard Color:CL/CL (Low-E:Solarcontrol LowE2
I Configuration::BP ;Argon Gas:Yes
Stacking:Reverse Stack Panels&Tracks:3 Panel/2 Track
Panel Configuration:OXX Door Type:Bypass
j Sill Riser Type:Narrow Sill Riser Height:4"
Screen Rail Qty:1 Muntin type:No Grid
Screen Type:1816 Charcoal I Screen Panels:Box Screen
Astragal Orientation:Astragal Box In Screen Quantity:1
Primary Lock Type:Mortise Lock Panel Type:SIMIK
Panel 3(OSLI):Raised Interior&Exterior Panel 2(OSLI):Raised Interior&Exterior
Primary Lock Location:39 Handle Color:Black i
X-Panel Rollers:Stainless Steel Tandem 'Secondary Lock Type:None
'Panel Reinforcement:Aluminum Heavy-Duty Astragal:Yes
O-Panel Rollers:Stainless Steel Tandem Heavy-Duty Stiles:Yes
Certification:Miami-Dade NOA(in HVHZ) Which NOA:15-0106.09 SM(exp.3/24/2020)
Substrate:Concrete AnchorType:1/4"Elco Ultracon
FPANumber:FL251 Water:13.5000
Calculated DP+:90.0000 i Calculated DP-:130.0000
http://www.exoquote.com/exoquote/Reporting/(S(kxubO 1 xsvhisoceg 13 slupht))/ExoRepor... 12/16/2015
Page 2 of 2
r
� Rf�dlarb�l�slillf��€Z001� '4�r�aber�l-acc000� k I
j 'NFRC COGVT(Use for Turtle Code)::0.3700 i'NFRC Label:VT:0.2700
NFRC CondResistance:17.0000 p NFRC Energy Star Zone:Does Not Qualify s