51" X80"
REPLACE DOOR&SIDELIGHT IN 1 OPENING ONLY.
LESS THAN 25%OF TOTAL GLAZED AREA TO BE REPLACED UNDER THIS PERMIT.SHUTTERS
NOT REQUIRED PER FBC,5TH EDITION(2014), EXISTING BUILDINGS,706.4,EXCEPTION#2.
OPENING PRODUCT DESIGN
OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS
NO. WIDTH. HGT. FTG. ZONE POS. NEG. (N.O.A.#) POS. NEG.
1 51 80 28.33 4 35.5 -38.7 FL16468.6 50.0 1 -50.0 FRONT ENTRY-LSMI
U-FACTOR SHGC
DOOR 0.30 0.20
S/L 0.24 0.11
REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS.
NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS.
ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 1/4" TAPCON SCREWS INTO CONCRETE
WITH A MINIMUM 1 3/8"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS.
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES
MEAN ROOF HEIGHT= 13 FT 2 IN
TRUE RESIDENCE
5401 DEER RUN DRIVE DOOR REPLACEMENT PLAN
FORT PIERCE, FLORIDA