Loading...
HomeMy WebLinkAboutDrawing 1 51" X80" REPLACE DOOR&SIDELIGHT IN 1 OPENING ONLY. LESS THAN 25%OF TOTAL GLAZED AREA TO BE REPLACED UNDER THIS PERMIT.SHUTTERS NOT REQUIRED PER FBC,5TH EDITION(2014), EXISTING BUILDINGS,706.4,EXCEPTION#2. OPENING PRODUCT DESIGN OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS NO. WIDTH. HGT. FTG. ZONE POS. NEG. (N.O.A.#) POS. NEG. 1 51 80 28.33 4 35.5 -38.7 FL16468.6 50.0 1 -50.0 FRONT ENTRY-LSMI U-FACTOR SHGC DOOR 0.30 0.20 S/L 0.24 0.11 REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS. NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS. ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 1/4" TAPCON SCREWS INTO CONCRETE WITH A MINIMUM 1 3/8"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS. SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES MEAN ROOF HEIGHT= 13 FT 2 IN TRUE RESIDENCE 5401 DEER RUN DRIVE DOOR REPLACEMENT PLAN FORT PIERCE, FLORIDA