Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Building Permit Application
ALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: Permit Number:1 Building Permit Application Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772)462-1553 Fax: (772)462-1578 Commercial Reside PERMIT APPLICATION FOR: Roof PROPOSED IMPROVEMENT LOCATION: Address: 3717 PEBBLE BEACH LANE PORT ST. LUCIE FL. 34952 Legal Description: SEC 25 TWN 36 S RANGE 40 E Property Tax ID#: 3425-705-0057-000-2 Lot No. Site Plan Name: Block No. Project Name: MILDRED DALLO Setbacks Front Back: Right Side: Left Side: DETAILED DESCRIPTION OF WORK: REMOVE EXISTING SHINGLED ROOF. INSTALL SOPREMA RESISTO SHINGLE UNDERLAYMENT DIRECT TO DECK. INSTALL TAMKO HERITAGE SHINGLES. INSTALL SUN TEK .H-cF SKYLIGHTS 2/12 PITCH ONE STORY CONSTRUCTION INFORMATION: Additional work to be performed under this permit—check all appy: HVAC Gas Tank ❑Gas Piping _Shutters Windows/Doors Electric ❑ Plumbing Sprinklers Generator Roof Total Sq. Ft of Construction: 1500 SFt. of First Floor: Cost of Construction: $ 5,800.00 Utilities:n Sewer O Septic Building Height: 13 FT OWNER/LESSEE:. = CONTRACTOR: Name MILDRED DALLO Name: GARY MARZO Address:3717 PEBBLE BEACH LANE Company: GARY MARZO, INC. City: PORT SAINT LUCIE State:FL. Address: 861 A-SW LAKEHURST DRIVE Zip Code: 34952 Fax: City: PORT SAINT LUCIE State:FL Phone No.772-343-0953 Zip Code: 34983 Fax: 772-465-8829 E-Mail: Phone No. 772-871-2489 Fill in fee simple Title Holder on next page (if different E-Mail: GMARZOINC@AOL.COM from the Owner listed above) State or County License: CC-C058193 If value of construction is$2500 or more,a RECORDED Notice of Commencement is required. SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION: DESIGNER/ENGINEER: _ Not Applicable MORTGAGE COMPANY: _Not Applicable Name: Name: Address: Address: City: State: City: State: Zip: Phone: Zip: Phone: FEE SIMPLE TITLE HOLDER: _Not Applicable BONDING COMPANY: Not Applicable Name: Name: Address: Address: City: City: Zip: Phone: Zip: Phone: I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will,in all respects, perform the work in accordance with the approved plans,the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review:room additions, accessory structures,swimming pools,fences,walls,signs,screen rooms and accessory uses to another non-residential use WARNING TO OWNER:Your failure to Record a Notice of Commencement may result in your paying twice for improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite before the first inspection. If you intend to obtain financing, consult with lender or an attorney before commencing work or recording our Notice of Commencement. 9:�a)_Til N Ylh t:rs " NAW—____ s _Signature of wn r/Lessee/A Signatu of Cpnt act r/Lic a Holder STATE OF FLORIDA STATE OF FLO IDA COUNTY OF Sr.LUCIE COUNTY OF ST.LUCIE The forgoing instrum was acknowledged before me The forgoing instrument was acknowledged before me this day of OW1 (/Lt 20 &y this s day of JANUARY 20 /&by DAVID VANDERF�IER DAVID VANDERFLIER (Name of person acknowledgin ) (Name of person ackn I ging) signature of fVoaa Publiate of Florida ) (Signatur.e of_N.otary_P.ublicz„Statelof Florida ) Personally Know Personally K ' ' Type of Identific itxPt... .... P ►VID VAN Type of Identil ica o I, ©MAMID VANDERIFLIER MY COMMISSION#FF099550 '€ MY COMMISSION#FF099550 Commission No. '�...�... EXPIRESM& 9, 2018 Commission N -° aoP.= EXPIRES Marc(6%3a 018 '•`^•..,.:,, (407)398-0153 FloridallotaryService.com (407)396-0153 FloridallotarySewice.com Revised 07/15/2014 REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE COMPLETE INITIALS . f �RINI ':ERD 5.6.3 Bond to Mechanically Attached Base Laver: Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, Lastobond TU HT, Lastobond, Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip-Rite Eave & Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR applied to: ➢ ASTM D226,Type I or 11 felt;Sopra-G;Modified Sopra-G. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam-on tile systems (Lastobond TU HT only), base layer shall be attached in accordance with FRSA/TRI April 2012(04-12). 5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems, where the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam-on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind pressures. 5.6.4.1 Maximum Design Pressure=-45.0 psf. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Primer: (Optional)Elastocol Stick or Elastocol 600c Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered. 5.6.4.2 Maximum Design Pressure=-67.5 psf. Deck: Structural concrete to meet project requirements to satisfaction of AHJ. Primer: Elastocol 600c Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered. 5.6.4.3 Maximum Design Pressure=-60.0 psf. Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps(FBC 1517.5.2)spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three, equally spaced rows in the center of the sheet. Underlayment: Lastobond TU HT or Colphene FR GR,self-adhered 5.6.4.4 Maximum Design Pressure=-90.0 psf. Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of AHJ. Underlayment: Unilay(e) mechanically attached with Soprafix Polymer Batten Bar (PBB) or Soprafix Metal Batten Bar(MBB) with Soprema#15-EL fasteners spaced 6-inch o.c. within the 5- inch wide, self-adhering side laps. End laps are 6-inch wide and sealed using either heat-welding or hot-air welding techniques. 5.7 Exposure Limitations: Lastobond, Lastobond 195,Lastobond Eco, Lastobond Smooth Seal HT, RESISTO LB1236, Grip-Rite Eave & Valley Protector or RESISTO LB1244 shall not be left exposed for longer than 30-days after installation. Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT or Lastobond Pro HT-S shall not be left exposed for longer than 90-days after installation. Lastobond TU HT or Colphene FR GR or Unilay(e) shall not be left exposed for longer than 180-days after installation. Exterior Research and Design,I.I.C. Evaluation Report 518010.06.09-R9 Certificate of Authorization#9503 FL2569-Rll Revision 9:10/12/2015 Page 5 of 7 eters TRINI 6. INSTALLATION: 6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate with Elastocol Stick or Elastocol 600c(if applicable). 6.3 Lastobond TU HT Lastobond Shield Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT Lastobond Pro HT-S,Lastobond Lastobond 195 Lastobond Eco, Lastobond Smooth Seal HT, RESISTO LB1236 Grip-Rite Eave&Valley Protector RESISTO LB1244 or Colphene FR GR: 6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.3.2 Non-Tile Applications: While priming is optional, Soprema recommends priming with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within 24 hours. Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of release film. Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible. Once the entire length of membrane is in place, peel-off the release film diagonally while holding the membrane tight. Firmly roll the membrane into place to achieve a bond. Horizontal seams should be minimum 3-Inches, configured to shed water. Vertical seams should be 6- inches and staggered not less than 2-ft from vertical seams in the course below. All over-granule end-laps shall be sealed using either heat-welding or hot air welding techniques. When installing at slopes above 8:12, Soprema recommends back-nailing in the overlap area at the top of the sheet at 12-inch o.c. For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in each direction. For valleys,apply the sheet starting at the lowest point and work upward. 6.3.3 Tile Applications(Lastobond TU HT or Colphene FR GR only): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For foam-on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that fall outside the scope of FRSA/TRI April 2012(04-12). Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. 6_4 Unila e : 6.4.1 Non-Tile Applications or Nail-On,Battened Tile Applications: Reference is made to Table 1 herein and FRSA/TRI April 2012(04-12) Installation Manual (if applicable). Apply sheet parallel to the roof edge and, starting at the eave with the selvedge-edge upslope, mechanically attach the 5-inch wide selvedge-edge to the wood deck with nails and tin caps or round cap- nails spaced 36-inch o.c. Apply the second course in a water-shedding manner with self-adhering side- laps. Vigorous hand or motorized roller pressure is applied to the self-adhering laps to ensure a watertight application. Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course below. All over-granule end-laps shall be sealed using either heat-welding or hot air welding techniques. Exterior Research and Design,I.I.C. Evaluation Report 518030.06.09-R9 Certificate of Authorization#9503 FL2569-R11 Revision 9:10/12/2015 Page 6 of 7 t TRINI-ry ER® Tile(if applicable)shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. 6.4.2 Foam-On Tile Applications: Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual, Table 1 herein and Section 5.6.4.4 herein. Apply sheet parallel to the roof edge and, starting at the eave with the selvedge-edge upslope, mechanically attach the 5-inch wide selvedge-edge to the wood deck Soprafix Polymer Batten Bar(PBB)or Soprafix Metal Batten Bar (MBB) with Soprema #15-EL fasteners spaced 6-inch o.c. Apply the second course in a water-shedding manner with self-adhering side-laps. Vigorous hand or motorized roller pressure is applied to the self-adhering laps to ensure a watertight application. Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course below. All over-granule end-laps shall be sealed using either heat-welding or hot air welding techniques. Tile shall be loaded and staged in a manner that prevents the slippage and/or damage to the underlayment. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the manufacturer or the named QA entity for information on plants covered under Rule 61G20-3 QA requirements. 9. QUALITY ASSURANCE ENTITY: UL, LLC—QUA9625;(314)578-3406; k.chancellor@us.ul.com -END OF EVALUATION REPORT- Exterior Research and Design,LLC. Evaluation Report 518010.06.09-R9 Certificate of Authorization 119503 FL2569-R11 Revision 9:10/12/2015 Page 7 of 7 Florida Building Code Online http://www.floridabWlding.orgipr/pr_app_dtl.aspx`?param--w(iEVXQ... i • ® 0 8 . r � 4 a (i il0fd3 LZ°p3fttT12fttf BCIS Home t Loglin f User Registration ' Hot Topics ; Submlt 5urcharge ; Stats&Facts 'Publications FBC Staff BCIS Site Map Links Search Business Professi real product Approval USER:Public User Regulation Product Approval Menu>Product or ApoUcatloo Search>Application List>Application Detail FL# FL12570-R2 Application Type Rev'Sio` Code Version 2010:. Application Status Approved *Approved by DCA.Approvals by DCA shall be reviewed and ratified by the POC and/or the Commission If necessary. Comments Archived Product Manufacturer Sun Tek Mfg Address/Phone/Email 10303 General Dr Orlando,FL 32824 (407)859-2117 ifeudner@sun-tek.com Authorized Signature James Feudner engineer!ng@sun-tek.com Technical Representative James Feudner Address/Phone/Email 10303-Gene-ra I Dr Orlando, FL 2824 engineering@sun-tek.com Quality Assurance Representative James Feudner Address/Phone/Email 10303 General Dr Orlando, FL 32824 (407)859-2117 Ext 111 engineering@sun-tek.com Category Sky Lights Subcategory Skylight Compliance Method Certification Mark or Listing Certification Agency National Accreditation&Management Institute, Validated By National Accreditation&Management Institute, Referenced Standard and Year(of Standard) Standard Year TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By of 3 5/29/2013 11:24 AM Florida Building Code Online http://www.floridabuilding.orgtpr/pr_app_dti.aspi 1param—W(i. VXQ... Product Approval Method Method 1 Option A Date Submitted 03/14/2012 Date Validated 08/17/2012 Date Pending FBC Approval Date Approved 08/20/2012 Summary of Products FL# Model;,Number or Name . Description.. 12570.1 CMA-D curb mounted polycarbonate bubble with welded aluminum ring Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL12570 R2 C CAC CMADNI011086.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 11/30/2014 Design Pressure: +60/-60 Installation Instructions Other: FL12570 R2 II CMADinstallsBCIS.pdf Verified By:James D.Wells.Jr. P.E. P.E.#53616 Created by Independent Third Party:Yes Evaluation Reports F1-12570 R2 AE.5 14 12 CMAD Aporoved Evaluation Report.pdf Created by Independent Third Party:Yes 12570.2 HSF. Self flashing aluminum frame with polycarbonate bubble. Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FLI2570 R2 C CAC HSFNI011087(2).pdf. Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 11/30/2014 Design Pressure: +60/-60. Installation Instructions Other: max size r.o.46.5 x 46.5 FL12570 R2 II HSFlnstallsBCIS.pdf Verified By:James D.Wells Jr. P.E. P.E.#53616 Created by Independent Third Party:Yes EvaluationReports FL12570 R2 AE 5 21 12 HSF Approved Prod Eval Report.odf Created by Independent Third Party:Yes 12570.3 1.ICMG Curb mounted glass impact rated skylight Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL12570 R2 C CAC ICMGNI006223-R4(2).pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 04/30/2014 Design Pressure: +60/-60 Installation Instructions Other:'max size Ko.46.5 x 46.5 FL12570 R2 II ICMGinstallsBCIS.pdf Verified By:James D. Wells Jr. P.E. P.E.#53616 Created by Independent Third Party:Yes . Evaluation Reports FL12570 R2 AE 7 16 12 ICMG Approved Evaluation report. df Created by Independent Third Party:Yes 12570.4 ISFG Self flashing Impact rated glass skylight Limits of Use Certification Agency Certificate Approved.for use in HVHZ:Yes FL12570 R2 C CAC ISFGNI006214-R4.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 04/30/2014 Design Pressure: +60/-60 Installation Instructions Other:.max size 46.5 x 46.5 FL12570 R2 II ISFGInstallsBCIS.odf Verified By:James D.Wells.Jr. P.E. P.E.#53616 Created by Independent Third Party:Yes Evaluation Reports FL12570 R2 AE 7 17 12 ISFG Approved Product Evaluation Report.pdf Created by.Independent Third Party:Yes. . . . 12570.5 MD-CMA Curb mounted polycarbonate bubble with welded aluminum ring. of 3 5/29/2013 11:24 AM ?lorida Building Code Online http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQ... Y,, Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL12570 R2 C CAC MDCMANIO06216-R4.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistants Yes 04/30/2014 Design Pressure: +60/-60 Installation Instructions Other: max.size 22.5.x 46.5 FL12570 R2.II NIDCMAinstallsBCIS.odf 'Verified By:James D.Wells Jr. RE:P.E.#53616 Created by Independent Third Party:Yes . Evaluation Reports FL12570 R2 AE 6 6 12 Approved MD-CMA-Prod Eval Report 003.pdf Created by Independent Third Party:Yes Back Next Contact Us::1940 North Monroe Street Tallahassee FL 32399 Phone;850-487-1824 The State of Florida is an AA/EEO employer.Coovriahi 2007-2010 State of Florida ::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with'an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please clickeh.re. Product Approval Accepts: of 3 5/29/2013 11:24 AM Sun-Tek SkylightsPolycarbonate Skylights from Sun-Tek http://www.sun-tek.com/home/how-to-choose/sun-durapoly-skylights Skylight Ideas Choosing a Sun-Tek Skylight 61, (Product Pages) PolyDome • Sun-Tek PolyDome Series Skylig Sun Tek Tube Skylights y distinguished by their easy Inst. Spyder Multi-Tube Polycarbonate Skylights and their Long-wearing durabili Skylight System Over thirty five years ago,Sun-Tek Skylights emerged as one of • The PolyDome Series is made vu the leading manufacturers of durable, high-strength Er G.E Lexan®Resin. Glass Skylights polycarbonate skylights in the nation. • PolyDome Skylights are 30 time j Polycarbonate Skylights We built our reputation on our PolyDome Skylight line and we impact resistant than acrylic sk 250 times more impact resistar Self Flashing continue to evolve and expand this range, including our new standard glass. Sapphire Self Sun-Tek Sapphire prism dome that has become an instant favorite . The Polycarbonate in our Polyp Flashing by adding a distinctive, modern flair to each finished project. skylights is the same product u: produce airplane windows and Aluminum insulated Polydome Series is for you. helmets. Self Flashing If you're looking for an economical and durable skylight,the • Sun-Tek PolyDome Skylights are Self Flashing stabilized for long lasting prote Aluminum/W • Polycarbonate skylights resist t, INFORMATIONSIZE extremes from a frigid-60° bel Curb Mount 6¢e rode 1414 1422 1430 1446 1919 2II2 2230 2236 2246 1269 3030 3036 3069 3576 4646 4991401 an oven baking+250° degrees. Curb Mount snap ■ 1 g 1 ■ ■ ■ I I 1 ■ 1 1 ■ ■ , ' • The polycarbonate skylights ar( Aluminum oayi du l4 in IS 2.02 2.77 417 138 1.11 l40 S30 639 10.21 6N 132 140.3 89S 1438 21M 2796 energy efficient and backed by qft. Tile Polycarbonate 1 03 w UN' 71K' 144" IPr 19!5' SY 11K" 724' 22W W IPS" NY 1Pr M, "W 8K 1645' warranty with a 223 Year"Corro Upenmq 141r 22r 108' 46% MY Mir 105' 36Y MY 695' 185' 464' 675• MW A- 67Y 897r Through"warranty on the metz Extreme i Weather w 13!5' IDS' 13IY I14 18, 211f 21K' 21K' 21K 21,5' 2915' NY M' 1515' W' 4S4" OF . SF Et SFPH models carry a 5 yea Fnished �{ Skylights �pnln9 11 13114' 211r 291r 4515" Ir" 1115" 2A. 73K' 4Sh 697r 29K' 4' Jr IM• /Pr 681i' A' 'LUrbMaunt 1Di' 17K' 178' IT' 23!r 75!5' 2514' 2SK' 7515' 27r ]175' 7Di' 77X' 37i' 199' /9K' 19!5' COMMERCIAL SKYLIGHTS M9denGnb , , , Outside RK' 2555• I7K' ®15' 2215' 27':' )113' 191r 49T 7Dr 119' 491' 72W 19K' 198' 72K' 924' Skylight Purchasing Fltf�n{en[!I 16' 16' 16' 16' 16' 16" 16' General Polycarbonate Warrant g $paan9 16" I6" Id' 2d' 24' 34' S4' 2d' 2Y a a a� 12' 24' 31' IY 2Y 1r 12' 1r 48' u' 48' Skylight Accessories rse6MamtModllsa emadel'L gethan mdmrt dedanero ootoaOPxfn 6mn 49nuam ai tl0.�h'.wK' Skylight InstClick to Enlarge allation Instructions Skylight Satisfaction Contact Sun-Tek SUN-TEK CATALOG T:407 859-2117 1 F:407 859-6607 1 E:customerservice@sun-tek.com I o 2011 Sun-Tek Manufacturing,Inc.•10303 General Drive•Orlando,FL 32824 1 All Rights Rese 1 of 1 1/6/2016 10:03 AM