Loading...
HomeMy WebLinkAboutProduct Approval lorida Building Code Online http://www.tiorldabulldmg.org/pr/pr_app_dtl.aspx!param=w(i>;vx... ` ��-- -�-�- '; E ' • ''������. -- .,�--tom Cuff I €� BCIS Home ! Log In User Registration Hot Topics f Submit Surcharge Stats&Facts i Publications FBC S[aff I BCLS SRe Map I Lucks Search Business ), Professional @USER:Product Approval Public User Regulation! ?19S1JdGLE«BL4YaIMgnu>PrsLdl a iD�. eE�lsh>3PDat!otLl.lst>Application Detail if Y FL# FL1956-R11 Application Type Revision Code Version 2014 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.. Comments Archived Product Manufacturer TAMKO Building Products,Inc. Address/Phone/Email PO Box 1404 Joplin,MO 64802 (417)624-6644 Ext 2305 kerri—eden@tamko.com Authorized Signature Kerrl Eden kerri_eden@tamko.com Technical Representative Kerri Eden Address/Phone/Email PO Box 1404 Joplin,MO 64802 (417)624-6644 Ext 2305 kerri—eden@tamko.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Certification Mark or Listing Certification Agency UL LLC Validated By Robert J.M. Nieminen,PE J Validation Checklist-Hardcopy Received Referenced Standard and Year(of Standard) Standard Year ASTM D3161 2009 ASTM D3462 2009 ASTM D7158 2008 Equivalence of Product Standards Certified By of 4 9/14/2015 11:15 AM ,lorida Building Code Online http://www.tlorldabUlldmg.org�pr/pr app_dti.aspx'!param=weir vx... Product Approval Method Method 1 Option A Date Submitted 03/20/2015 Date Validated 04/02/2015 Date Pending FBC Approval Date Approved 04/06/2015 Summary of Products FL# Model, Description Number or Name 1956.1 Elite Glass-Seal A three tab asphalt shingle. Limits of Use Certification Agency Certificate Approved for use In FL195f_R11 C CAC._.Ian:ko Sery Ctfnf FL 1956 2012.nd HVHZ:No FL1956_R11 C CAC UL certification 10-11-12.od_f Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 10/10/2015 Impact Resistant: N/A Installation Instructions Design Pressure:N/A FL1956_Rll 11 G!ass Seal Elite Glass Seal app inst.odf Other:Asphalt shingles Verified By: Robert Nleminen 59166 shall be used only on roof Created by Independent Third Party: No slopes of 2:12 or greater. Evaluation Reports Nails must be used as the Created by Independent Third Parry: method of attachment. 1956.2 Glass-Seal A three tab asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in FL1A_56 R11 C CAC Tamko Sery Conf FL 1956 20.12.pdf HVHZ:No FL1956 R11 C CAC UL certification 10-11-12.pdf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 10/10/2015 Impact Resistant: N/A Installation Instructions Design Pressure: N/A `L1956 Rii II Glass Seal Elite Glass Seal app inst�df Other:Asphalt shingles Verified By: Robert Nieminen PE 59166 shall be used only on roof Created by Independent Third Party: No slopes of 2:12 or greater. Evaluation Reports Nails must be used as the Created by Independent Third Party: method of attachment. 1956.3 Heritage A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in FL1�56 911 CS9C_Tamko Sery Cont FL 1956 2012rif HVHZ:No FLio R1�_C_CAUL�ertf!cati n -11-12.adf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 10/10/2015 Impact Resistant: N/A Installation Instructions Design Pressure:N/AFL19 6 11 fI_ Heli[�ge D F� P app inst.pdf Other:Asphalt shingles FL1956 RLI.II Heritaga F app inst.p4if shall be used only on roof FL1956 R11 II Heritage T app !nst.odf slopes of 2:12 or greater. Verified By: Robert J.M.Nieminen FL 59166 Nails must be used as the Created by Independent Third Party: No method of attachment. Evaluation Reports Created by Independent Third Party: 1956.4 Heritage 30 A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in FL1956 R11_C CAC_Tarnko Sery ConF FL 1956 2012.gdf HVHZ:No FL1956 R11 C CAC UL certification 10-11-12.odf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 10/10/2015 Impact Resistant: N/A Installation Instructions Design Pressure: N/A FL1956 R11 II herltage 30 app Ins Aril 10.pdf Other:Asphalt shingles FL1_4.56 R21 11 heritage 30 anp Inst f april 1Qpdf shall be used only on roof Verified By: Robert Nleminen PE 59166 slopes of 2:12 or greater. Created by Independent Third Party: No Nails must be used as the Evaluation Reports method of attachment. Created by Independent Third Party: of 4 9/14/2015 11:15 AM ,loridaBuilding Code Online http://www.tioridabuilding.org/pr/pr_app_utl.aspx'!param=weir vx... 1956.5 Heritage 50 A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in FL1956 RS_1 C CAC Tamko 5�Cg.Of FL 1956 2012:Pd HVHZ:No FL1956_ RI C CAC UL certification 10 li 12.pdf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 10/10/2015 Impact Resistant: N/A Installation Instructions Design Pressure:N/A FL1.956 R11_i1 10-Pdf Other:Asphalt shingles Fl]9Sn_R11_!I__heritaee._50 aup-i-051-f aPril_1Q-pdf shall be used only on roof Verified By: Robert Nieminen PE 59166 slopes of 2:12 or greater. Created by Independent Third Party: No Nails must be used as the Evaluation Reports method of attachment. Created by Independent Third Party: 1956.6 Heritage A dimensional asphalt shingle. Premium Limits of Use Certification Agency Certificate Approved for use in FLk956 R11 C CAC Temko Sery Conf FL 1956 2012.pdf HVHZ:No FL1956 R11 C CAC UL certification 10-11-1—df Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 10/10/2015 Impact Resistant: N/A Installation Instructions Design Pressure: N/A FLig56 Ril I, Heritage Premium D P app insdf Other:Asphalt shingles FLL1;56,R1i 1I Heritaoe Premium app irist.pdf shall be used only on roof Ft.1956 P11 II_Heritane Premium T app instQdf slopes of 2:12 or greater. Verified By: Robert Nieminen 59166 Nails must be used as the Created by Independent Third Party: No method of attachment. Evaluation Reports Created by Independent Third Party: 1956.7 Heritage A heavy weight dimensional asphalt shingle. Vintage Limits of Use Certification Agency Certificate Approved for use in FL1956 RiI C CAC—FL1g56_,R9_C QAC Tarn Serv�or FL 1956 2012.p-tif HVHZ:No FL1956 R11 C CAC UL shingle matrix.pdf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 10/10/2015 Impact Resistant: N/A Installation Instructions Design Pressure: N/A FL1956 R11 II Heritage Vintage app inst.odf Other:Asphalt shingles Verified By: Robert J.M.Nieminen PE 59166 shall be used only on roof Created by Independent Third Party: No slopes of 2:12 or greater. Evaluation Reports Nails must be used as the Created by Independent Third Party: method of attachment. 1956.8 Heritage Hip and ridge shingles Vintage 12 X 12 Hip and Ridge Limits of Use Certification Agency Certificate Approved for use in FL1956 R11 C CAC FL1956 R9 C CAC Tamko Sery Conf FL 1956 2012.pdf HVHZ: No FL1956 R11 C CAC UL shingle matrix.pdf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 10/10/2015 Impact Resistant: N/A Installation Instructions Design Pressure:N/A FL1956 1111 II TAMKO1 HeritageR 12 •x 12 Hip and Ridge Application Instruction�df Other:Asphalt shingles Verified By: Robert J.M. Nieminen PE 59166 shall be used only on roof Created by Independent Third Party: No slopes of 2:12 or greater. Evaluation Reports Nails must be used as the Created by Independent Third Party: method of attachment. 1956.9 Heritage A dimensional asphalt shingle. Woodgate Limits of Use Certification Agency Certificate Approved for use in FL1.956_3F Q21�df HVHZ:No FLI 56 R11 C CAC UL certification 10-11-12.pdf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 10/10/2015 Impact Resistant:N/A Installation Instructions Design Pressure: N/A FL195r R11 I1 Heli _ge Woodgate_p app inst,ndf Other:Asphalt shingles F_1 125_6Ri 1_I.I Heriial9e—�No2d9a1e_FapR instdl shall be used only on roof Verified By: Robert Nieminen 59166 slopes of 2:12 or greater. Created by Independent Third Party: No of 4 9/14/2015 11:15 AM lorida Builcling Code Unline nttp://www.iiorlaaouitaing.org/pr/pr_app_an.aspx:param=wvr,vA... Nails must be used as the Evaluation Reports method of attachment. Created by Independent Third Party: 1956.10 1 Heritage XL A dimensional asphalt shingle. Limits of Use Certification Agency Certificate Approved for use in FL1956 R11 C .CAC Tamko Sery Conf FL-1956 2012:pdf HVHZ:NorL-�95o Ril C CPC UL'certification 10-11-12,pdf Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 10/10/2015 Impact Resistant: N/A Installation Instructions Design Pressure:N/A FL19.56 R11 II heritage xl apo inst d aDtil lO.DdF Other:Asphalt shingles FL1956 Rif II heritagex1 aDp jnst f april 10.Ddf shall be used only on roof Verified By: Robert Nieminen PE 59166 slopes of 2:12 or greater. Created by Independent Third Party: No Nails must be used as the Evaluation Reports method of attachment. Created by Independent Third Party: 1956.11 Hip and Ridge Hip and ridge shingles Shingles Limits of Use Certification Agency Certificate Approved for use in FL1956_R11_C CAC._:[o(nko 5grv_CQ]r f_FL 19,56 4 pd[ HVHZ: No FL1955 RI L C CAC UL certifjcatiorL:LQ- 1-12_p.((_f Approved for use outside Quality Assurance Contract Expiration Date HVHZ:Yes 10/10/2015 Impact Resistant:N/A Installation Instructions Design Pressure:N/A FL1956 Ril f1 12. x12 HID and Ridge.Ddf Other: Hip and Ridge F1 6 R21 1I 1Z x 12 HipRidge Aulication inptryctijns_.idf shingles shall be used only F11956 R1.1 II .12-1-4x?22_NipRid9e,_SealanC Dab jllustra ions. df on roof slopes of 2:12 orpL19.5E._gti__l,(__Lzx:l?_�al2�icf9G_SgaI�1I Doh lllustrations.Ddf greater. Nails must be used Verified By: Robert Nieminen 59166 as the method of Created by Independent Third Party: No attachment, Evaluation Reports Created by Independent Third Party: Back, Next Contact Us::2940 North Monroe Street,Tallahassee Fl.3 3 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective Octobe(1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click berg_ Product Approval Accepts: FCheY sccuritva::riucec of 4 9/14/2015 11:15 AM `�"A :KDO HERITAGE" 38 &AKINETE® &OPEAUT 099@931,90 Dallas, TX o Tuscaloosa, AL o Phillipsburg, KS Joplin, MO THESE ARE THE MANUFACTURER'S APPLICATION INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED. TAMKO BUILDING PRODUCTS,INC.ASSUMES NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING DEFECTS RESULTING FROM FAILURE TO FOLLOW THE MANUFACTURER'S INSTRUCTIONS. THIS PRODUCT IS COVERED BY A LIMITED WARRANTY,THE TERMS OF WHICH ARE PRINTED ON THE WRAPPER. IN COLD WEATHER(BELOW 40"F),CARE MUST BE TAKEN TO AVOID DAMAGE TO THE EDGES AND CORNERS OF THE SHINGLES. IMPORTANT:It is not necessary to remove the plastic strip from the back of the shingles. L INOW OEM S. These shingles are for application to roof decks capable of receiving WIND CAUTION: Extreme wind velocities can damage these and retaining fasteners,and to inclines of not less than 2 in.per foot. shingles after application when proper sealing of the shingles For roofs.having pitches 2 in.per foot to less than 4 in.per foot,refer does not occur. This can especially be a problem if the shingles to special instructions titled"Low Slope Application".Shingles must are applied in cooler months or in areas on the roof that do not be applied properly.TAMKO assumes no responsibility for leaks or receive direct sunlight.These conditions may impede the sealing defects resulting from improper application, or failure to properly of the adhesive strips on the shingles.The inability to seal down prepare the surface to be roofed over. may be compounded by prolonged cold weather conditions and/ NEW ROOF DECK CONSTRUCTION:Roof deck must be smooth, or blowing dust.In these situations,hand sealing of the shingles is dry and free from warped surfaces. It is recommended that metal recommended.To insure immediate sealing,apply 4 quarter-sized dabs of TAM-PRO Premium SBS Adhesive or TAMKO Tam-Seal drip edges be installed at eaves and rakes. Adhesive on the back of the shingle 1 in.(25mm)and 13 in.(330mm) PLYWOOD:All plywood shall be exterior grade as defined by the in from each side and 1 in. (25mm) up from the bottom of the Engineered Wood Association:Plywood shall be a minimum of 3/8 shingle.Press shingle firmly into the adhesive.For maximum wind in.thickness and applied in accordance with the recommendations resistance along rakes,cement shingles to the underlayment and of the Engineered Wood Association. each other in a 4 in.(102mm)width of TAM-PRO SBS Adhesive or SHEATHING BOARDS: Boards shall be well-seasoned tongue- TAMKO Tam-Seal Adhesive. Caution:Apply ONLY a thin uniform and-groove boards and not over 6 in.nominal width.Boards shall layer of adhesive less than 1/8 in.(3mm)thick.Excessive amounts be a 1 in. nominal minimum thickness. Boards shall be properly can cause blistering of the shingles and may soften the asphalt in spaced and nailed, certain underlayments resulting in the asphalt flowing,dripping and staining.Shingles must also be fastened according to the fastening instructions described below. Inadequate ventilation of attic spaces can cause accumulation of Correct placement of the fasteners is critical to the performance moisture in winter months and a build up of heat in the summer. of the shingle. If the fasteners are not placed as shown in the These conditions can lead to: diagram and described below,this will result in the termination of TAMKO's liabilities under the limited warranty.TAMKO will not be 1.Vapor Condensation responsible for damage to shingles caused by winds in excess of 2.Buckling of shingles due to deck movement. the applicable mph as stated in the limited warranty. See limited 3.Rotting of wood members. warranty for details. FASTENING PATTERNS:Fasteners must be placed 6-1/8 in.from 4.Premature failure of roof. the bottom edge of the shingle, penetrating through the common To insure adequate ventilation and circulation of air, place louvers bond,and located horizontally as follows: of sufficient size high in the gable ends and/or install continuous 1)Standard Fastening Pattern.(For use on decks with slopes 2 in. ridge and soffit vents. FHA minimum property standards require per foot to 21 in.per foot.)One fastener 1 in. back from each end one square foot of net free ventilation area to each 150 square feet and one 13-1/2 in.back from each end of the shingle for a total of 4 of space to be vented,or one square foot per 300 square feet if a fasteners.(See standard fastening pattern illustrated below). vapor barrier is installed on the warm side of the ceiling or if at least one half of the ventilation is provided near the ridge.If the ventilation STANDARD FASTENING PATTERN openings are screened,the total area should be doubled. FASTENERS NAIL ZONE COMMON BOND IT IS PARTICULARLY IMPORTANT TO PROVIDE 6-1/8" ADEQUATE VENTILATION. FEXPOSURE5-5/8" 12-1/2"--+—12-3/8"—+— 12-1/2"—� �-1" (Continued) Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 11/09 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055 Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656 tanllis®.Oom Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 ® (CONTINUED from page 1) 30 Dallas, TX o Tuscaloosa, AL o Phillipsburg, KS o Joplin, MO 2) Mansard Fastening Pattern. (For use on decks with slopes be a minimum of 1-1/4 in.for new construction and 1-1/2 in. for greater than 21 in.per foot.)One fastener 1 in.back from each end reroofing thus allowing a minimum deck penetration of 3/4 in.The and one fastener 8-1/2 in.back from each end and one fastener 16 crown of the staple must be parallel to the length of the shingle. in. back from each end for a total of 6 fasteners per shingle. (See The staple crown should be driven flush with the shingle surface. Mansard and High Wind Fastening Pattern illustrated below.) Staples that are crooked,underdriven or overdriven are considered MANSARD AND HIGH WIND FASTENING PATTERN improperly applied. FASTENERS NAIL ZONE Properly Driven Improperly Driven COMMONf91 a1 underddven overdriven crooked BOND Asphalt bw Shingles 5' EXPOSURE 5-501 .E �} bob Decking 3) High Wind Fastening Pattern. (For High Wind Application CAUTION:ALL FASTENERS MUST BE DRIVEN INTO THE NAIL requirements)One fastener 1 in.back from each end.One fastener ZONE/COMMON BOND AS SHOWN IN THE DIAGRAM ABOVE. 8-1/2 in.back from each end and one fastener 16 in.back from each a.>196l9D �Hok1P6'fdl6�u end fora total of six(6)fasteners per shingle.In addition to this shingle fastening pattern requirement for High Wind Application, TAMKO UNDERLAYMENT:An underlayment consisting of asphalt saturated also requires the use of the following TAMKO products: TAMKO felt must be applied over the entire deck before the installation of felts or underlayments;TAMKO Moisture Guard Plus underlayment TAMKO shingles.Failure to add underlayment can cause premature at all eaves,rakes,and valleys;TAMKO or TAM-PRO cements and failure of the shingles which is not covered by TAMKO's limited coatings products where required;TAMKO ventilation where required, warranty.Apply the felt when the deck is dry.On roof decks 4 in. TAM KO starter shingles if available in area,and TAMKO Hip and Ridge per foot and greater apply the felt parallel to the eaves lapping each shingles installed on all hips and ridges.Along rakes,cement shingles course of the felt over the lower course at least 2 in.Where ends to the underlayment and each other in a4 in.(102 mm)width of TAM- join, lap the felt 4 in. If left exposed, the underlayment felt may PRO SBS Adhesive or TAMKO Tam-Seal Adhesive.Also,see local be adversely affected by moisture and weathering. Laying of the building codes for proper nailing application.High Wind Application underlayment and the shingle application must be done together. Is offered on new construction or complete tear-off applications only. Products which are acceptable for use as underlayment are: It is not offered for recover applications. If High Wind Application requirements are not followed,the High Wind Application Warranty — TAMKO No.15 Asphalt Saturated Organic Felt MPH, as stated on Table I in the Limited Warranty, reverts to the — A non-perforated asphalt saturated organic felt which meets Standard Application Wind Warranty MPH limit.(See Mansard and ASTM:D226,Type I or ASTM D4869,Type I High Wind Fastening Pattern illustrated above.) — Any TAMKO non-perforated asphalt saturated organic felt NAILS:TAMKO recommends the use of nails as the preferred method — TAMKO TW Metal and Tile Underlayment,TW Underlayment and Moisture Guard Plus® (additional ventilation may be of application. Standard type roofing nails should be usedNail required.Contact TAMKO's Technical Services Department shanks should be made of minimum 12 gauge wire,and a minimum for more information.) head diameter of 3/8 in.Nails should be long enough to penetrate 3/4 in.into the roof deck.Where the deck is less than 3/4 in.thick, In areas where ice builds up along the eaves or a back-up of water the nails should be long enough to penetrate completely through from frozen or clogged gutters is a potential problem, TAMKO's plywood decking and extend at least 1/8 in.through the roof deck. Moisture Guard Plus®waterproofing underlayment(or any specialty Drive nail head flush with the shingle surface. eaves flashing product) may be applied to eaves, rakes, ridges, valleys, around chimneys, skylights or dormers to help prevent Properly Driven Improperly Driven water damage. Contact TAMKO's Technical Services Department min diameter underdriven overdriven crooked for more information. <—Asphalt Shingles TAMKO does not recommend the use of any substitute products E� I\ •—Decking as shingle underlayment. V 1/4"nominal straight,good penetration, Inadequate too deep,cuts Inadequate 9•APP�BCEu D®PA B�YSa�N9��©E� end flush Kith shingle surface penetration Into shingle anchorage STARTER COURSE:A starter course may consist of TAMKO Shingle Starter,self-sealing 3-tab shingles or a 9 inch wide strip of mineral STAPLES: If staples are used in the attaching process,follow the surface roll roofing.If self-sealing 3-tab shingles are used,remove above instructions for placement.All staples must be driven with the exposed tab portion and install with the factory applied adhesive pneumatic staplers.The staple must meet the following minimum adjacent to the eaves. Attach the starter course with approved dimensional requirements.Staples must be made from a minimum fasteners along a line parallel to and 3 in.to 4 in,above the eaves 16 gauge galvanized wire.Crown width must be at least 15/16 in. edge.The starter course should overhang both the eaves and rake (staple crown width is measured outsidethe legs).Leg length should edges 1/4 in.to 3/8 in. (Continued) Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 11/09 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick, MD 21701 800-368-2055 Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656 taI'9'9koxo9'➢i9 Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 2 ® (CONTINUED from page 2) ETA:M ® HERITAGE° 30 NUMBING PRODUCTI NATrr9QNATIED a91PHAVe SHRA1105922 Dallas, TX c Tuscaloosa, AL o Phillipsburg, KS o Joplin, MO SHINGLE APPLICATION:Start the first course with a full size shingle S.RAW 91610FE AP!>LICA` HOM and overhang the rake edge 1/4 in.Cut 1.0-3/8 in.from a full shingle On pitches 2 in.perfoot to 4 in.per foot coverthe deck with two layers to form a shingle 29 in.long.Use this to start the second course(see of asphalt saturated felt.Begin by applying the felt in a 19 in.wide strip diagram below).Cut a 23 in.long shingle to start the third course.Use along the eaves and overhanging the drip edge by 1/4 to 3/4 in.Place the remaining 16-3/8 in.piece of shingle to start the fourth course and a full 36 in.wide sheet over the 19 in.wide starter piece,completely use the remaining 10-3/8 in.piece to begin the fifth course.Continue overlapping it.All succeeding courses will be positioned to overlap the up the rake in as many rows as necessary using the same formula precedingcourse by 19 in.If winter temperatures average 25eForless, as outlined above.The butt of the shingle should be aligned with thoroughly cement the felts to each other with TAM-PRO or TAMKO the top edge of the sawtooth of the underlying shingle for a 5-5/8 in. Plastic Roof Cement from eaves and rakes to a point of a least 24 in. exposure(see shingle application drawing illustrated on this panel). inside the interior wall line of the building.As an alternative,TAMKO's When you make your final cut at the roof's edge,flip any pieces that Moisture Guard Plus)self-adhering waterproofing underlayment may are 8 in.or longer back onto the roof.These pieces can be worked be used in lieu of the cemented felts. in anywhere without creating zippers or color variations. NOTE: Do not align joints of shingle courses when working in cut T.6r��9��(iD ®®�®��������°®�� ®®� pieces.Joints should be no closer than 4 in.from one another. If theslope exceeds 21 in.perfoot(601,eachshingle must besealedwith TAM-PRO SBS Adhesive or TAMKO Tam-Seal Adhesive immediately upon installation.Spots of cement must be equivalent in size to a$.25 piece and applied to shingles with a 5-5/8 in.exposure,use 6 fasteners 10.3/8" per shingle.See Section 3 for the Mansard Fastening Pattern. repeat 10.3/8" 29;; courses 1s- " Before re-roofing,be certain to inspect the roof decks.All plywood 23" shall meet the requirements listed in Section 1. 29a Nail down or remove curled or broken shingles from the existing 16-3/8a 23° roof.Replace all missing shingles with new ones to provide a smooth rake Full base. Shingles that are buckled usually indicate warped decking 10-3/8" or protruding nails. Hammer down all protruding nails or remove them and refasten in a new location. Remove all drip edge metal 5th course 23° 16-3/8° and replace with new. 4th course 18 318" If re-roofing over an existing roof where new flashing is required 3rd course 23" to protect against ice dams(freeze/thaw cycle of water and/or the , 2nd oourse 2e" backup of water in frozen or clogged gutters),remove the old roofing ----- 29". to a point at least 24 in. beyond the interior wall line and apply lstcourse -_ Full 10-3/ea TAMKO's Moisture Guard Plus®waterproofing underlaymeht.Contact a-Gave TAMKO's Technical Services Department for more information. Measurements will vary when nesting over an existing 5 in.exposure single roof:Call TAMKO Technical Services for further information. 9 Cul your first eourso ehingle to mako 29°and a 10 3/6'.length.Cut asewndShingle tomake a23'and The nesting procedure described below is the preferred method for a 16 3!6°langlh. reroofing over existing metric size shingles with a 5-5/8 in.exposure. 29° '103,18 = - See description below: 23• l 163/8° Starter Course:Remove the tabs and an additional portion from the head of a full size shingle so that its height is equal to the exposure of the existing shingles.Position the resulting strip over the existing roof edge(with the factory-applied adhesive strip along the eaves). Cut approximately 6 in.from the rake end and apply the remaining ' portion at the eaves.Continue the starter strip by applying full length shingle strips cut to height as above,evenly along the existing roof at the eaves.The existing roof should overhang the eaves far Beat.nppL Vion Mth n lull length sningla. �-Then Lay yaar29.23'.163/8°and 103M'lengths. enough to carry water off into the gutter.If this is not the case, AS makeucansee.three shingles with two cuts cut and apply the starter strip so that it will provide sufficient make canseeas. pay P overhang for proper drainage. ca.Continue working yourway across the mat.Whenyou make your First Course:Remove an amount from the butt edge of a full-size t'I Bnal cul at Line roofs edge,gip any ptaose that are B'or longer back a'.the roof:These pieces ran be worked in anywhere wdthour shingle so that the remaining portion of the shingle fits between the emoting zippers or color w•iations. NOTE:Do net align joints of shingle courses when working In butts of the existing third course.This course must also be applied cul pieces.Mrits should be no closer than 4'from ono another, evenly along the eaves edge of the new starter strip. (Continued) Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 11/09 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055 Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656 tarok®.Com Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 ® (CONTINUED from page 3 ) TAO HERITAGE"' 30 Dallas, TX o Tuscaloosa, AL o Phillipsburg, KS o Joplin, MO Second and Succeeding Courses: Remove 10-3/8 in. from the FOR ALTERNATE VALLEY APPLICATION METHODS, PLEASE rake end of the first shingle in the second course, and continue CONTACT TAMKO'S TECHNICAL SERVICES DEPARTMENT. with full width shingles for the remainder of the course, placing the top edge of each new shingle against the butt edge of the old valley-Marine shingle in the course above.This method should create an exposure of Nail m3fi'wide shoal d 9 P of Nail Fast,Moisture of 5-5/8 in.after the first course.When beginning the succeeding or heavier Plus ll SOlb. endExtranailn 9 9 g or heavier roll rooting end at shingle courses continue to follow the Heritage application instructions. ztendend shmgle -161 byl.d (See section 5). A valley centerlirs Existing shingles /� �'C '�:i�•. / Untlerlayment NoevAtnin 8°off comcenterlris ne Drip edge Place rip of shingle an the edge or \\/ lne vertical shin inches hack Drip edge rrom valley centerlino.and covering New shingles the vertical shingle. 55/81, / 5 5/8"exposure M.. HEIP ANIM MODS IPAS u SP3M BETA 93 exposure i Apply the shingles with a 5 in. exposure beginning at the bottom I of the hip or from the end of the ridge opposite the direction of the prevailing winds.Secure each shingle with one fastener on each side, 5-1/2 in.back from the exposed end and 1 in.up from the edge. Over the shingle underlayment,center a minimum 36 in.wide sheet TAMKO recommends the use of TAMKO Hip & Ride shingle of TAMKO Nail-Fast®,Moisture Guard Plus°or a minimum 50 Ib.roll products.Where matching colors are available, it is acceptable to roofing in the valley.Nail the felt only where necessary to hold it in use TAMKO's Elite Glass-Seal shingles cut down to 12 in.pieces. place and then only nail the outside edges. IMPORTANT:PRIOR TO INSTALLATION WARM SHINGLES TO Fasteners should be 1/4 in.longer than the one used for shingles PREVENT DAMAGE WHICH CAN OCCUR WHILE BENDING IMPORTANT. PRIOR TO INSTALLATION, CARE NEEDS TO BE SHINGLES TO FORM VALLEY. TAKEN TO PREVENT DAMAGE WHICH CAN OCCUR WHILE After valley flashing is in place: BENDING SHINGLE IN COLD WEATHER. a Apply the first course of shingles along the eaves of one of the Direction of prevailing wind intersecting roof planes and across the valley. start 5"exposure Note:For proper flow of water over the trimmed shingle,always here— 1 r start applying the shingles on the roof plane that has the lower slope or less height, 4E4\ 2tener o Extend the end shingle at least 12 in.onto the adjoining roof. 'I he e Apply succeeding courses in the same manner,extending them 5"exposure across the valley and onto the adjoining roof. • Press the shingles tightly into the valley. THESE ARE THE MANUFACTURER'S APPLICATION • Use normal shingle fastening methods. INSTRUCTIONS FOR THE ROOFING CONDITIONS DESCRIBED.TAMKO BUILDING PRODUCTS, INC.ASSUMES Note:No fastener should be within 6in.ofthe valley centerline, NO RESPONSIBILITY FOR LEAKS OR OTHER ROOFING and two fasteners should be placed at the end of each shingle DEFECTS RESULTING FROM FAILURE TO FOLLOW THE crossing the valley. MANUFACTURER'S INSTRUCTIONS. a To the adjoining roof plane,apply one row of shingles vertically facing the valley and 2 in.back from the valley centerline. Note: For a neater installation, snap a chalkline over the TAMKOO,Moisture Guard PlusO,Nail FastO,TAM-PROD and Hedtage0 are registered P trademarks of TAMKO Building Products,Inc. shingles for guidance. Information included in these application instructions was current at time of printing.To o To complete the valley, apply shingles on the adjoining roof obtain a copy of the most current version of these application instructions,visit us online plane by positioning the tip of the first shingle of each row at at tamko.com or call us at 800-641-4691. the 2 in.point from the centerline where the edge of the vertical shingle has been applied,covering the vertical shingle. Central District 220 West 4th St., Joplin,MO 64801 800-641-4691 11/09 Visit Our Web Site at Northeast District 4500 Tamko Dr., Frederick,MD 21701 800-368-2055 Southeast District 2300 35th St., Tuscaloosa,AL 35401 800-228-2656 ta1mkoxo9'711 Southwest District 7910 S.Central Exp., Dallas,TX 75216 800-443-1834 Western District 5300 East 43rd Ave., Denver,CO 80216 800-530-8868 Q -- -- lorida Building Code Online http://www.floridabuilding.org/pr/pr_app_dtl.aspx?paratn=wGEVX... 11111,116v - x eMrP.ta r s i $,Inn 44,E v y N i S f 11`J3r i°ili BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Ma Busines, uct� Professional (_'A�USER PubliccU�seeroval Rieguiatio I Product Aooroval Menu>Product or Application Search>Application List>Application Detail FL# FL2569-R l l Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Soprema, Inc. (Canada) Address/Phone/Email 1640 rue Haggarty Drummondville, NON-US 00000 (819)478-2400 Ext 3327 memathieu@soprema.ca Authorized Signature Marc-Etienne Mathieu memathieu@soprema.ca Technical Representative Marc-Etienne Mathieu Address/Phone/Email 1688 lea n-Berchmans-Michaud Drummondville, NON-US 00000 (819)478-2400 Ext 3327 memathieu @soprema.ca Quality Assurance Representative Jean-Francois Cote, Ph.D. Address/Phone/Email 1640 rue Haggarty Drummondville (888) 811-3145 jfcote@soprema.ca Category Roofing Subcategory Underlayments i Compliance Method Evaluation Report from a Florida Registered Architect o Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert J. M. Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/16/2017 Validated By John W. Knezevich, PE of 3 1/5/2016 3:08 PM lorida Building Code Online http://www.tloridabuilding.org/pr/pr_app_dtl.aspx'iparam=w(iEVX... Validation Checklist- Hardcopy Received Certificate of Independence FL2569 R11 COI 2015 01 COI Nieminen.r)df Referenced Standard and Year(of Standard) Standard ASTM D1970 ASTM D6163 ASTM D6164 FM 4474 FRSA/TRI April 2012 (04-12) TAS 103 TAS 110 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/15/2015 Date Validated 10/19/2015 Date Pending FBC Approval 10/21/2015 Date Approved 12/15/2015 Summary of Products FL# Model, Number or Description Name 2569.1 Soprema Roof Self adhering roof underlayments Underlayments Limits of Use Installation Instructions Approved for use in HVHZ: No FL2569 R11 II 2015 10 FINAL ER SOPREMA CA UNDERLAW Approved for use outside Rll.pdf HVHZ:Yes Verified By: Robert Nieminen, P.E. PE-59166 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-90 Evaluation Reports Other: 1.) Refer to ER Section 5 for FL2569 R11 AE 2015 10 FINAL ER SOPREMA CA UNDERLAY Limits of Use. 2.)The design pressure R11.pdf noted herein pertains to underlayment Created by Independent Third Party: Yes systems used beneath adhesive-set tile systems. Refer to ER Section 5.6.4 for details. Back Next Contact Us:: 1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::B! Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records req of 3. 1/5/2016 3:08 PM lorida Building Code Online http://www.floridabuilding.org/pr/pr_app_dtl.aspx?pa==wGEVX electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487. Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department wi they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.Il supply a personal address,please provide the Department with an email address which can be made available to the public,To determine Ifyo Chapter 455,F.S,please click here. Product Approval Aocepts: of 3 1/5/2016 3:08 PM EXTERIOR RESEARCH &DESIGN, I.I.C. Certificate of Authorization#19503 TRINITY ' UNIT#13 ED 353 CHRISTIAOX ORD,�CT 6478 (� PHONE:(203)262-9245 FAX:(203)262-9243 EVALUATION REPORT Soprema, Inc. Evaluation Report 518010.06.09-119 1640 rue Haggerty FL2569-R11 Drummondville, Quebec J2C 5P8 Date of Issuance:06/15/2009 Canada Revision 9:10/12/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: Soprema Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in'its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: .• S � a l Robert J.M. Nieminen P.E. O'. /a Tt� The facsimile seal appearing was authorized by Robert Nieminen, _ tie.,•;;;, ' 7,. •, ,•'`; P.E.on 10/12/2015.This does notserve as an electronically signed Florida Registration No.59166 Florida DCA ANE1983 '',`s�� 4 document.Signed,sealed hardco ies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity)ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. . k ,k TRINI1 Y ER1� ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind Resistance FM 4474 2004 1507.2.4,1507.2.8, Physical Properties ASTM D1970 2009 1507.2.9.2,1507.4.5.1, 1507.5.3,1507.7.3 1507.11.2 Physical Properties ASTM D6163 2000 1507.11.2 Physical Properties ASTM D6164 2005 1523.6.5.2.1 Physical Properties TAS 103 1995 TAS 110 Accelerated Weathering TAS 110 2000 1507.3.3 Installation Practice FRSA/TRI April 2012(04-12) 2012 3. REFERENCES: Entity Examination Reference Date ERD(TST6049) ASTM D1970/TAS 110 2968.05.04-2 05/14/2004 ERD(TST6049) Physical Properties 2757.02.05 02/03/2005 ERD(TST6049) ASTM D1970/TAS 110 2974.03.05-2 05/17/2005 ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005 ERD(TST6049) Wind Resistance 2779.11.05-111 04/18/2007 ERD(TST6049) TAS 103/TAS 110 S7120.11.07-2 11/02/2007 ERD(TST6049) ASTM D1970/TAS 110 513190.02.09-111 04/01/2010 ERD(TST6049) ASTM D1970/TAS 110 531370.03.10-1-R1 04/07/2010 ERD(TST6049) Physical Properties/Tensile Adhesion 511150.05.10-R1 09/09/2010 ERD(TST6049) Physical Properties/Tensile Adhesion S11150.05.09-R2 10/05/2010 ERD(TST6049) ASTM D1970 S37210.11.11 11/09/2011 ERD(TST6049) ASTM D1970 S40540.02.13-1 02/19/2013 ERD(TST6049) Physical Properties/Tensile Adhesion S43530.02.14-1 02/21/2014 ERD(TST6049) Physical Properties/Tensile Adhesion SOPC-SC7645.02.15 02/13/2015 ERD(TST6049) Accelerated Weathering SOPC-SC8520.14 04/17/2015 M-D(CER1592) HVHZ Compliance 09-1005.02 11/04/2010 M-D(CER1592) HVHZ Compliance 13-0530.02 11/27/2014 ICC-ES(EVL2396) 2012,2009 and 2006 IBC Compliance ESR-1524 10/01/2014 PRI(TST5878) Physical Properties SOP-064-02-01 12/03/2013 Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 05/29/2015 UL,LLC(QUA9625) Quality Control Service Confirmation Exp.10/16/2017 4. PRODUCT DESCRIPTION: 4.1 Lastobond TU HT is a self-adhering, non-woven polyester fabric surfaced, SBS modified bitumen roof underlayment. 4.2 Lastobond Shield is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths;36 and 45 inch. 4.3 RESISTO SA SMOOTH PLY 40 is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment;available in 3.3 ft x 65 ft rolls. Exterior Research and Design,LLC. Evaluation Report S18010.06.09-R9 Certificate of Authorization#9503 FL2569-R11 Revision 9:10/12/2015 Page 2 of 7 TRINITY ERE? 4.4 Lastobond Shield HT is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment. 4.5 Lastobond Pro HT-N is a self-adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths;36 and 45 inch. 4.6 Lastobond Pro HT-S is a self-adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment. 4.7 Lastobond 195 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment. 4.8 Lastobond is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment. 4.9 Lastobond Eco is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment. 4.10 Lastobond Smooth Seal HT is a self-adhering, glass-mat reinforced, film-surfaced, SBS modified bitumen roof underlayment. 4.11 RESISTO LB1236 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment,with a 36-inch sheet width. 4.12 PrimeSource Grip-Rite Eave &Valley Protector is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment,with a 36-inch sheet width. 4.13 RESISTO LB1244 is a self-adhering, glass-mat reinforced, sand-surfaced, SBS modified bitumen roof underlayment,with a 44-inch sheet width. 4.14 Colphene FR GR is a self-adhering, fiberglass reinforced, granule-surfaced, SBS modified bitumen roof underlayment. 4.15 Unilay (e) is a mechanically attached, polyester reinforced, granule-surfaced, SBS modified bitumen roof underlayment. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the AHJ for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable roof covers applied atop the underlayments are follows: TABLE 1: ROOF COVER OPTIONS Asphalt Nail-On Foam-On Metal Wood Shakes& Slate Underlayment Shingles Tile Tile Shingles Lastobond TU HT Yes Yes Yes Yes Yes Yes See 5.5.1 Lastobond Shield/Pro HT-N/ Yes No No No Yes Yes RESISTO SA SMOOTH PLY 40 Lastobond Shield HT/Pro HT-S Yes No No Yes Yes Yes Lastobond/Lastobond 195 Yes No No No Yes I Yes Exterior Research and Design,I.I.C. Evaluation Report S18010.06.09-R9 Certificate of Authorization#9503 FL2569-Rll Revision 9:10/12/2015 Page 3 of 7 . t. TRINRY ERD TABLE 1: ROOF COVER OPTIONS Underlayment Asphalt Nail-On Foam-On Metal Wood Shakes& Slate Shingles Tile Tile Shingles Lastobond ECO /RESISTO LB1236,Grip-Rite Eave&Valley Yes No No No Yes Yes Protector/RESISTO LB1244 Lastobond Smooth Seal HT Yes No No Yes Yes Yes Colphene FR GR Yes Yes Yes No Yes Yes See 5.5.1 Unilay(e) Yes Yes Yes No No No Batten Only See 5.5.1 5.5.1 "Foam-On Tile" is limited to use of the following adhesives unless tensile adhesion/ long term aging data from an accredited testing laboratory is provided. Underlayment Adhesive(s) Lastobond TU HT 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332)or Dow Chemical TileBondTm Roof Tile Adhesive(FL717) Colphene FR GR 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332) Unilay(e) I 3M 2-Component Foam Roof Tile Adhesive AH-160(FL6332) 5.6 Allowable substrates are noted below: 5.6.1 Direct-Bond to Deck: Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, Lastobond TU HT, Lastobond, Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip-Rite Eave & Valley Protector, RESISTO LB1244 or Lastobond Smooth Seal HT applied to: ➢ Plywood; ASTM D41 primed plywood; OSB;ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine;ASTM D41 primed structural concrete. Colphene FR GR applied to: ➢ Plywood;ASTM D41 primed plywood;ASTM D41 primed structural concrete. Note: ➢ While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends priming with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within 24 hours. ➢ Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of the self-adhering underlayment. 5.6.2 Bond-to-Insulation: Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, Lastobond TU HT, Lastobond, Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip-Rite Eave & Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR applied to: ➢ Dens Deck Prime;SECU ROCK Gypsum-Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on the systems (Lastobond TU HT only), insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474,Appendix D or TAS 114,Appendix J. Exterior Research and Design,I.I.C. Evaluation Report 518010.06.09-119 Certificate of Authorization 119503 FL2569-R11 Revision 9:10/12/2015 Page 4 of 7