Loading...
HomeMy WebLinkAboutProduct Approval RECEI`."T JAN 06 2016 MIAMI-®SDEFILE COPY PRODUCT ICONICOUNTY CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy DAB Door Company,Inc. 12195 NW 981h Avenue Hialeah Gardens,FL 33018 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section([n Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION:Hurricane Master Model 824/811 Steel Sectional Garage Door up to 9'-4"Wide w/ Window Lite Option(DP+50.0,-60.0 PSF) APPROVAL DOCUMENT:Drawing No.01-09,titled"Sectional Garage Door",sheets 1 through 5 of 5, dated 02/01/2001,with last revision J dated 03/09/2015,prepared by Al-Farooq Corporation,signed and sealed by Javad Ahmad,P.E., bearing the Miami-Dade County Product Control revision stamp with the Notice of Acceptance number and expiration date by the Miami-Dade County Product Control Section. MISSILE IMPACT RATING:Large and Small Missile Impact Resistant LABELING:A permanent label with the manufacturer's name or logo,manufacturing address,model number,the positive and negative design pressure rating, indicate impact rated if applicable,installation instruction drawing reference number,approval number(NOA),the applicable test standards,and the statement reading`Miami-Dade County Product Control Approved' is to be located on the door's side track, bottom angle,or inner surface of a panel. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be.cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA#14-0814.04 and consists of this page 1 and evidence pages E-1 and E-2,as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M.Utrera,P.E. NOA No.15-0317.02 MIAMI•DADE COUNTY Expiration Date: August 9,2016 •• 9 1 Approval Date:June 11,2015 o��ozIZdls Page 1 DAB Door Company,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. 01-09,titled"Sectional Garage Door",sheets 1 through 5 of 5,dated 02/01/2001,with last revision J dated 03/0912015;prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad,P.E. B. TESTS "Submitted under NOA#09-0128.04" 1. Test reports on 1)Uniform Static Air Pressure Test,Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC,TAS 201-94 3) Cyclic Wind Pressure Loading per FBC,TAS 203-94 4)Forced Entry Test,per FBC 2411 3.2.1,TAS 202-94 ' i along with marked-up drawings and installation diagram of a DAB 824 24 GA Sectional Garage Door with Fixed Windows,prepared by Hurricane Engineering& Testing,Inc, Test Reports No. HETI-08-2149A/B, dated 06/27/2008,signed and sealed by Candido F.Font,P.E. "Submitted under NOA #09-0128.04" 2. Test report of Tensile Test per ASTM E 8,Report No. HETI 08-T182,prepared by Hurricane Engineering & Testing, Inc., dated 12/23/2008, signed and sealed by Candido F. Pont,P.E. "Submitted under NOA # 01-0516.03" 3. Test report of large missile impact test per PA 201 and cyclic wind pressure test per PA 203 on"Sectional Residential Garage Door",prepared by Hurricane Engineering &Testing,Inc.,Report No. HETI 01-974A,dated 01/29/2001, signed and sealed by Hector M. Medina,P.E. 4. Test report of Uniform Static Air Pressure Test per PA 202 and Force Entry Resistance Test on"Sectional Residential Garage Door",prepared by Hurricane Engineering &Testing,Inc.,Report No. HETI 01-969,dated 01/18/2001, signed and sealed by Hector M. Medina,P.E. 5. Test report on Salt Spray(Corrosion)Test per ASTM B 117 of a painted G-40 steel panels,prepared by Celotex Corporation,Test Report No. 258592, dated 08/17/1998, signed by W.A. Jackson,P.E. 06/02/Zeis Carlos M.Utrera,P.E. Product Control Examiner NOA No. 15-0317.02 Expiration Date:August 9,2016 Approval Date:June 11,2015 E-1 DAB Door Company,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED C. CALCULATIONS "Submitted under NOA#14-0814.04" 1. Anchor verification calculations prepared by Al-Farooq Corporation,dated 09/22/2014 and 07/24/2014,signed and sealed by Javad Ahmad,P.E. "Submitted under NDA#09-0128.04" 2. Anchor verification calculations prepared by Al-Farooq Corporation,complying with F.B.0 2007,dated 12/19/2008,signed and sealed by Humayoun Farooq,P.E. D. QUALITY ASSURANCE 1. Miami-Dade Department of Regulatory and Economic Resources(RER) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 13-0717.01,issued to SABIC Innovative Plastics,for their Lexan Sheet Products,approved on 11/28/2013 and expiring on 07/17/2018. 2. Notice of Acceptance No. 14-0311.08,issued to Insulfoam,LLC,for their Insulfoam Expanded Polystyrene Insulation,approved on 08/14/2014 and expiring on 11/29/2017. 3. Notice of Acceptance No. 11-0926.07,issued to Dyplast Products,LLC,for their Expanded Polystyrene Block Type Insulation,approved on 11/10/2011 and expiring on 01/11/2017. 4. Notice of Acceptance No. 11-0926.06,issued to Dyplast Products,LLC,for their Dyplast ISO-C1 Polyisocyanurate Insulation,approved on 11/10/2011 and expiring on 01/11/2017. 5. Notice of Acceptance No. 10-1129.04, issued to Cellofoam North America Inc,for their Expanded Polystyrene Block Insulation,approved on 02/24/2011 and expiring on 02/24/2016. "Submitted under NOA#05-0228.02" 6. Test Report on Accelerated Weathering Using Xenon Arc Light Apparatus Test per ASTM G155 of"PVC Extrusion Material",prepared by Hurricane Engineering& Testing,Inc.,Report No.HETI 04-A002, dated 09/27/2004, signed and sealed by Rafael E. Droz-Seda,P.E. 7. Test Reports on Tensile Test per ASTM D638 of"PVC Extrusion Material',prepared by Hurricane Engineering&Testing Inc.,Report No.HETI 04-T251,dated 11/29/2004 signed and sealed by I. Ghia,P.E. 8. Test Report on Self-Ignition Temperature Test,Rate of Burn Test and Smoke Density Test of"REHAU non-foam PVC extrusion material',prepared by ETC Laboratories, Report No. 04-761-15019.0,dated 05/06/2004,signed and sealed by J.L.Doldan,P.E. F. STATEMENTS "Submitted under NOA#14-0814.04" 1. Statement letter of code conformance to the 5"edition(2014)FBC and of no financial interest issued by Al-Farooq Corporation, dated 05/13/2014,signed and sealed by Javad Ahmad,P.E. 06 a2 ��S Carlos M.Utrera,P.E. Product Control Examiner NOA No. 15-0317.02 Expiration Date:August 9,2016 Approval Date:June 11,2015 E-2 7-1/2"X 3"X .071"GALV. STEEL TOP FIXTURE 5-1/2"X 2-3/4"X 0.1" END ROLLER HINGESTEEL PLATE WITH ONE 5/16-18 MS W/NUT W/(6) #14 X 5/8"SMS /---_ FASTENED TO END STILE WITH OPTIONAL DOOR VIEWER WITHOUT DELRON SLEEVE (STD.) (6) #14 X 3/4"SELF DRILLING SCREWS TO BE INSTALLED AT WITH DELRON SLEEVE(OPTIONAL) / ENTER STILE Y IW `, CENTER STILE 0 F ray I� f�c yA aU, ry�U OO 01 y 0 IL 0 t a I 1 . n A ,1, O GALV 25TEEL CENTER HINGE ! ``````•`�`�� m1 04�Q d W1 (4) #14 x 5/8"SMS _ B r, � B �o o Q�3 LL WITH DELRON SLEEVE(OPTIONAL) I: r,o o z Ei a U. _ I z rc z LOCK a w .i IIr �������� 0 0 0 0 0o", w 2/DOOR / °� 1 1"W X .15"THK. LATCH r i — — = 7- -- --- - m 24 GA. STEEL PANEL �{�� m 3/16"ALUM RIVETS z n Q � w F � � Z N FLAPS BENT OVER PANEL Q d w icy O w ^ 1/2" PUNCHED HOLES) -.024"STL. PANEL 0 4"O.C. OUTSIDE OF DOOR O Ocl I Q W LL N LLwm c— STEEL TRACK BRACKET FASTENED SOLID BRASS DOOR VIEWER TO WOOD JAMB WITH BY 'SCHLAGE SECURITY HARDWARE' 5/16'X 1-5/8"LAG SCREW INSTALLED IN 9/16" DIA. HOLES IN CENTER STILE (FULLY THREADED) POSITIONED AT EYE LEVEL END STILE I o 00 ONE PER BRACKET p ANCHORS AT TRACK BRACKET: of M OPTIONAL STOP MOULDING A) 3/8"DIA. POWER-BOLT BY'POWERS' w BY DOOR INSTALLER w FOR CONNECTION OF WOOD BUCK 2'MIN. EMBED INTO CONCRETE C7 Q TO MASONRY SEE NOTE ON SHEET 4 1-7/8'•MIN. EDGE DISTANCE < U 2 - a 114 X 5/8"SMS Q•Z N v; e 6 PER HINGE 3/4"%IL X 2-1/2'X IB GA.STEEL B) '1/e'DA. H SLEEVE BY'HIL71' (7 — Z n END STILE,CONNECT TO PANELS WITH CO w 1/2"X 1-3/4"X.059"FORMED STEEL FLAPS AND 3/16"ALUM RIVETS 1-1/4"MIN. EMBED INTO CONCRETE OR FILLED BLOCK ¢ (/) mm I SOUTHERN PINE CLUED TO PANEL AND SECURED TO SEE DETAIL ABOVE 1-5/8"MIN. EDGE DISTANCE INTO CONCRETE Z 4 e 0.55 S.G. EOG DIST:! END STILE WITH 3/16'POP RIVETS ® 12"O.C. 4'MIN. EDGE DISTANCE INTO FILLED BLOCK 0 oz U N U O =n ° - 1-7/8'X 2-5/8'% 045"STEEL EDGE ------III CONCRETE Vc = 3000 PSI MIN. m J v •+ I Z I CENTER STILE.GLUED AND RIVETED DISTANCE I C-90 GROUT FILLED BLOCK I'm = 2000 PSI MIN. Q N Q , I I TO PANEL W/(4) 3/16'RNETS 1 1/2" MIN. I I POP RIVETS , N14 X 5/B"S.M.S. e .-dl t_3/16} r --� 4/HINGE \see.. o ^1-3/161 t' /ANCHOR TYPE A OR 8 0 1.9"X 2.19"X 3.3•' X.102" (1) PER BRACKET STEEL TRACK BRACKETS SEE SHEET 3 FOR BRACKET SPACING u V V u SEE SHEET 3 FOR SPACING , 7INGE 1/4-20 SS BOLT h NUTo 7-1/2'X ,071"GALV. STEELCENTER HINGE 7-I/2"X 3" c" "7/16"PUSHNUTSECTION B—BEND ROLLER HINSTALLED ON ROLLER SHAFTEngr:JAVAD AHNADE{�vINTERIOR SIDE 82" RS (STD.)STEEL TRACK 1.82" DIA. % OPTIONAL FLA.PEIW#N 7059214 GA.%2-1/8'X 1"(STANDARD) 4CA.N.. A"IMM No 3/ 012 CA%3-5/16"% 1-1/2'(OPTIONAL) 2.75" DIA. X .50STEEL RO (OPTIONAL; DUe 4 o FASTENED TO TRACK PLATES 2.75" DIA. X .50"NYLON ROLLERS (OPTIONAL) '�T��'TTTTTTT"""'""" �o a W/ 1/4-20 X 5/8'TRUSS 110, WITH 5"STEM my SLOTTED M.S.& LOCK NUT dfaw_ no. 015 01-09 sheet 2 of-51) POP RIVETS 2 X 2 X 1/8"HORIZ.ANGLE f�1 m 2" _*FASTERNELD ` 5/16"X 1-5/8" LAG SCREWS INTO WOOD OR HORIZ.TRACK SUPPORT, SPOT WELDED TO HORIZ.TRACK {�V / 2-3/4"X 5-1/2"X 3"X.104" 5/16"SLEEVE ANCHORS CENTER SUPPORT READ. ON DOORS WITH TWO WELDS AT 1-1/2"APARTGALVBRACKET ON EACH SIDE TEEL WITH 1-1/4EMBED INTOMASONRY EXPEEDING 8 Fr. IN HEIGHFIRST AT 3"O.C._ 3 PER BRACKET11 A REST AT 9"O.CNU (6) 1d%5/8"S.M.S. _ II 1 CONNECTED TO FLAG BRACKET ANGLE ZT/ K.GALV.STEEL ADJUSTABLE AD T085PRINC S/4-BOLT HAf7 GUIDE WITH OSTENED TO BRACKET 2-1/2"X 4-1/4"X 13 GA. STEEL PLATES 6-18 X 3/4"HEX HEAD WELDED TO 1-1/2"X 1-1/2" X 14 GA.ANGLE -- A (2) 1/4-20 X 5/8BOLT&NUT WS&NUTS. FASTENED 70 TRACK - -- dTOP BRACKET WITH (4) 1/4-20 SS. BOLT& NUTS - -- HORIZTRACK LENGTH = OPENING HEIGHT PLUS 12" w(STANDARD) gTOP BRACKET O LL (OPTIONAL) VERTICAL TRACK� = LOW HEADROOM DOOR 14 GA GALV.STEEL TRACK 2-1/8"% 1"X.080" V O m — o HORIZONTAL REINFORCEMENT SECTION A-A a o w roa>Q N o -`l 1/2"X 1-3/4"X.059"FORMEDSTEEL 2"X 5-1/2"X.104" I qT r GLUED TO PANEL AND FASTENED TO GALV.STEEL - e uo a VERTICAL STILES WITH FASTENED W/(4)H 14 X 5/8"S.M.S. ¢ IS N a (2)3/16"POP RIVETS TOP ROLLER BRACKET FOR Q W 3 LL N LOW HEADROOM DOOR OPTION {L Z N E o HORIZONTAL REINFORCEMENT DOOR " SECTION HEIGHTS BRACKET PLACEMENTS Q 0 N d 1/2"% 1-3/4"X . FORMED STEEL HEIGHT 1ST 2ND 3RD 4TH 5TH BI B2 83 84 I B5 B6 B7 B8 � j CLUED TO PANEL ANOD FASTENED TO - /VF.RTICAI.STILES WITH —I 6'-0" 18° 18" 18" 18"N/A 1"TO 2"11-3/d"I 23" 34" 45" 56 67" (2)3/16"POP RIVETS 6'-6" 21"18" 78"i21"N/A 1"TO 2"11-3/4"i 23" 34" 45" 56" 67" - - --- -- 5/16"MEETING RIB 21" 21'121"N/A 1"TO 2"11-3/4" 23" 34" 45° 56 67" T-6" 18" 18"118"118" 18"1"TO 2"11-3/4" 23" 34" 45" 56 67" 78-1/4" 1.82"DIA. X .50"ROLLERS tE -}. ... 8'-0" 21" 18"118"118" 21"1"TO 2"71-3/4" 23" 34" 45" 56" 67" 78-1/4" Of m W/.hh DIA. % 4-1/4" STEM w u "-SECTIONS ARE NUMBERED STARTING AT THE BOTTOM I O` o M _m FOR DOORS MORE THAN 8 FT. HIGH, USE ADDITIONAL TRACK BRACKETS AT 10" O.C. Ld O LL M OPTIONAL INSULATIONS: m I Q J BY'DYPI0.ST PRODUCTS LLC' w g m I Q u- EPS-EXPANDED POLYSTYRENE 0-o m DENSITY= 1.05 PCF o 1.9"X 2.19"X 3.3"X .090" / 6 Z I=..(/j °Na STEEL TRACK BRACKETS O - Z .o N.O.A. #11-0926.07 n 2-3/16"HIGH OR m mo I CONNECTED TO TRACK WITH / Q N ISO-25 POLY-ISOCYANURATE } 1/4"BOLTS&NUTS. j_ Z ¢ m o f DENSITY- 2.0 PCF F i_ / � C)ZN.OA. #11-0926.06 I OR / w p = o d BY'CELLOFOAM NORTH AMERICA' % DENSITY= 1.03 PCF mm j Q N Q N.O.A.A10-1129.04 OR l �_- BY'INSULFOAM_LLC- DENSITY=0.92 PCF m N.O.A. j .�' N.O.A. x'14-0311,08 mELLL-ILl ®\14 CA GALV.STEEL � ROLLER HINGES FASTENED W1 W/(4) #14 X 5/8"SMS mm s U a MIN, .024"ROLL FORMED STEEL PANEL 533 DRAWING DUALITY G-40 -� �x 3� -_ W:THYIELD STRENGTH=34 KSI PRIMER AND BAKED-ON TRACK CONFIGURATION v o POLYSTER PAINTED TOP COAT r APPLIED TO BOTH SIDES OF STEEL K S O o 0 J O^ VERTICAL LIFT HIGH ltI STANDARD LIFT LOW HEADROOM .�o a DOUBLE TRACK - x - 12 GA.GALV. STEEL AVAILABLE TRACK OPTIONS T BOTTOM BRACKET FASTENED i I -�W/(4) X14%5/8"SMS Engr:JAVAD PHMAD - CML FLA.PE I(70592 r�� � n I x k, 2015 w1d�C.&BOTTOM SEAL OPTIONSASEE SHEET 4pkdm SECB! dr0wing no. 01-09 TION A-A Lshee 5 3.4" REINFORCEMENT IN. 1/2"% 1-3/4'X.056" 4� o DOE FORMED STEEL o� _ DIST. NB X 1" __ t W SELF DRILLING SCREWS '/ 1-1 2"MIN. OR -1V� - - --� �8 X 1" � W z / _q I SELF DRILLING SCREWS Z 1 3/16"'RNEX'STEEL RIVETS OGE DIST. o I I m OR C FZ m m� , \ MULTIGRIP W DOME HEAD W W o i o /AT 48"O.C. 3/16"'RIVE%'STEEL RIVETS Iii N MULTIGRIP W/DOME HEAD �3 nAT 48'O.C.REINFORCEMENT 0 1/2'% 1-3/4"X .OSB"FORMED STEEL O 11.u 28Y ul 1/4"DIA.LAC SCREWS 2BY I 1/4'DIA. LAG SCREWS p u WOOD BUCK 1 j� AT 6'FROM ENDS W000 BUCK AT 6"FROM ENDS - O y / 1 AND 19"O.C.MAX, j I AND 19"O.C. MAX. 7 1 I W.STRIP ADAPTER w Leri 0 ALUMINUM TEERIP ADAPTER 0 10.Q QO C�W� RUBBER W'STRIPPING RUBBER W'STRIPPING Q: p N WLd N_o T .040 )LQf7 cMV .224534 .700 - 348 �k p ILLLSSS---���fff I -------� 1.7so�+I 7 1.790—^ BOTTOM SEAL OPTIONS OPTION 'A' OPTION 'B' w WOOD BUCK CONNECTION TO WOOD SUBSTRATE (WOOD SPECIFIC GRAVITY SG-0.55 MIN.) I Co THE INSTALLATION METHODS SHOWN ABOVE SHOWS 2X6 SYP WOOD BUCK ATTACHMENT IW r7 TO WOOD STRUCTURES. IF THESE METHODS ARE FOLLOWED NO ADDITIONAL CALCULATIONS/DESIGN Q G WILL BE REQUIRED FOR DESIGN OF GARAGE DOOR ANCHORAGE. --- K FOR DOOR REPLACEMENT APPLICATIONS WITH NO ENGINEER OF RECORD,INSTALLATION MAY BE -_,._ ANCHOR SPACING_ < L) = n ANCHORS STRUCTURE EMBED SPACING EDGE DIST. Z ~ VERIFIED AND APPROVED BY THE BUILDING OFFICIAL UPON INSPECTION. _ __ - 0 G e 3 B HLC SLEEVE BY HILTI'__EE 1-1 4' 8" 1_578 J In wo 3 8' HLC SLEEVE BY'HILTI' 1-I 4" Q 3 8"DYNABOLT BY'ITW' 1-I/2" ._ B— 2' ZO 3 w 3/8-DYNABOLT BY'lIW'5/16' X 1-5/8' STEEL STRUCTURE BY OTHERS 3/8'POWER-BOLT BY'POWERS' 2" 8" I-•7 8 CJ O Z 2 N LAC SCREWS MUST SUPPORT THE LOADS IMPOSED J/8"SLEEVE-ALL BY'SIMPSONS'I CONC_ 1_ ul go n AT 12'O.C. BY DOOR SYSTEM - m J CONCRETE Fc = 3000 PSI MIN. Q N Q J C-90 GROUT FILLED BLOCK I'm = 2000 PSI MIN. _ ' 5/16"DIA BOLTS WITH WASHER k NUT --- WOOD BUCK CONNECTION TO MASONRY [AT 12"O.C. MAX. PRESSURE TREATED 2X6 SYP WOOD JAMBS WHICH SHALL BE ANCHORED TO n EDGE DIST. W GROUTED REINFORCED MASONRY BLOCK WALL OR CONC.COLUMN WITH 1 1/4"ULTRACON BY'ELCO'WITH SPACING OF d ` 4 I6°O.C. INTO GROUT FILLED BLOCK WALL,WITH 2-1/4'MIN.EMBED 16°O.C. INTO 3000 PSI CONCRETE,WITH 1-3/4"MIN.EMBED I _1-1/4'X 2-1/2'X 14 GA I o g 2-1/2"MIN. EDGE DISTANCE 1I 1/2"I 1-1/2" CONT.STEEL ANGLE 11-1/z I 1/4"TAPPER BY'POWERS'WITH SPACING OF h 14'O.C.INTO GROUT FILLED BLOCK WALL,WITH 1-1/2"MIN. EMBED 12 GA. GALL.STEEL -- B"X 1°X 14 GA. 16"O.C. NTO 3000 PSI CONCRETE,WITH 1-3/4"MIN.EMBED 1/16-X 2_1/2 FLAT BRACKETS f3"LONG GALL. STEEL TRACK 'R 3"MIN. EDGE DISTANCE FILLET WELDS AT 12"O.C.IN DOOR OPNG. FASTENED TO TRACK PLATES 3 8"CONFLEX BY'ELCO'OR AT 12"O.C.MAX. AT 18'O.C.ABOVE DOOR OPNG. W/(2) 1/4-20X5/8"TRUSS HD. / CONNECTED TO CONT.ANGLE SLOTTED M.S.h LOCK NUT 3/8'LOT BY'ITW'WITH SPACING OF W/(3)SPOT WELDS AT EACH SIDE y= = 24"O.C. INTO 3000 PSI CONCRETE,WITH 2-I/2"MIN. EMBED 2"MIN. EDGE DISTANCE CONTINUOUS ANGLE TRACK REVERSE TRACK COMINULUS ANGLE TRACK TO WOOD RUCK TO STEEL TO CONCRETE AND FILLED 3/8"HLC SLEEVE BY'IIILTI'WITH SPACING OF 8"O.C. INTO GROUT FILLED BLOCK WALL,WITH 1-1/4"MIN. EMBED, 4"MIN. EDGE 01ST. ---� 18'O.C. INTO 3000 PSI CONCRETE,WITH 1-1/4"MIN.EMBED AND e 2-1/2'MIN. EDGE DISTANCE ALTERNATE TRACK INSTALLATION _ Engr:JAVAD AM MAD PREPARATION OF JAMBS BY OTHERS clvL PRODWC ABY" i PE 70592 '- FOR NEWCONSTRUCTION ENGINEER OF RECORD OR ARCHITECT TO VERIFY FLA. �otv�)riy pmt Plorld� C.A.N. 53B r An OF SUPPORTING STRUCTURE TO SUPPORT LOADS IMPOSED ����� BY DOOR SYSTEM. A00'0DW0C No 3( G� _ FOR DOOR REPLACEMENT IN RETROFIT BUILDINGS WITH NO ENGINEER OF RECORD,DOOR INSTALLATION MAY BE REVIEWED AND APPROVED BY BUILDING OFFICIAL UPON INSPECTION. By ha4ltf Cb6Fr1 wing no.1 MAXIMUM EXTERIOR(+)LOAD PER JAMB = (9.33' X 50 PSF)/2 = 233.3 Lbs per Fl. M 015 X01=09 j MAX MUM INTERIOR(-) LOAD PER JAMB (9.33'X 60 PSF)/2 m 279.9 Lbs per Ft. sheet 4 of 5 .500250 r, a * PLASTIC COMPLIES WITH �� 4Iv DOOR PANEL CHAPTER 26 OF FBC 24 GA.(.024)STEEL MIN. SEE EVIDENCE PAGE o Z m lu 1.765 71,7125CL Q CL N 7/16"DIA.WASHER0 J m 1.144 a . o� ti d8%3/4"SMS 21 3/4" I p M OJ/8°FROM ENDS MAX. 175- b t- 800 o OC g A 111 III' II i AND 7"O.C.MAX. WDW.WIDTH 0�n C ~I _ * EXTERIOR FRAME * INTERIOR FRAME J j 18 1/8" RIGID PVC ONE PIECE INJECTION RIGID PVC ONE PIECE INJECTION 1,1 3 a I 4 B X 3 4°SMS -- Q N I I ()R / a i O MAX. - W N.o I LI II II ® 1-3/8"FROM ENDS D.L.O. LL Z: I 1:I I! ; �•1 AND 6-1/2"O.C. MA). o ut .J L,NZ((MVy J I ! 4 I !III 175 X.062 DEEP y 4. GROOVE ._ i _O I IIII I1 `j J1 d' S — M IIII 1/4"POLYCARBONATE LEXAN { I.' I % I Id I ; BY'SABIC INNOVATIVE PLASTICS' ¢J I I NOA#13-0717.01 A A tL I U 1 UZ x N :Iy < aI o � .. .. p O 37 a: 0( ] ao w O1 0 1 Oo IIII U' N IIII I I .J ' w Z¢= o in N Q J O x r I � 'III I J V] O E .175 X.062 DEEP zi GROOVE +�s f2�n uto Tit I i INSIDE ELEVATION(4NB X°3/M1"SMS 1-/8FROM ENDS® - RAISED PANEL EMBOSSED DOOR WITH OPTIONAL WINDOWS Nlo wloo III dr AND 6-1/2"D.C. MAX. WINDOW LITES CAN BE IN ANY LOCATION IN DOOR SECTION ° _ �I= x #8X 3/4°SMS C '' 1 III 1 1 ®3/6°FROM ENDS .175 X.062 DEEP ROOVE r 1 1 AND 4-I/2"O.C. MAX.MA% 0 1 #8 X 3/4"SMS ®3/8"FROM ENDS AND 7°O.C.MAX. _ Engr:JAVAD AHMAD I o CIVIL F7 PRODUCTU� L'W J V ) o > 7/16"DIA.WASHER - - - - - - - - - - - - - - - FIA.PE 70 92 Mllfl�ly..r.,y Wltb 1l1l 41do o \�l -- �--- CAN.3530 Yd101C�Cu6 s ^ - --•-- Aoeepdne No S- !7 6 5 0 � DOOR PANEL EXTERIOR 24 GA. (.024) STEEL MIN. fi '- DOOR PANEL 15/16"MIN. D.L.OPG M rPiI � dFawing no. 2.4 GA. (.024)STEEL MIN, GIAZING BITE 01-09 WINDOW WIDTH Sheel rj of 5 y These Tables Are For GARAGE DOORS.IN One and Two Family Dwellings Garage Doors Installed In Buildings with a Mean Roof Height of 30' or Less Located in Exposures B, C or D Table R301.2(2) of the 5t' Edition FBG Residential COMPONENTS AND CLADDING WORST CASE DESIGN PRESSURE [PSF] ❑160 EXPOSURE B 9'x 7' Door=+24.3 -27.5 1-1160 EXPOSURE IB 16'x 7' Door=+23.3 -26.0 (❑160_EXPOSURE C 9'-X7'-Door=j 29.5_..---33:3 (1 story and max 15' M160 EXPOSURE`C-16'X 7"Door=+28.2 -31.5 mean roof height) ❑160 EXPOSURE C 9'x 7' Door=+34.1 -38.5 (2 story and max 30' ❑160 EXPOSURE C 16'X 7' Door=+32.7 -36.4 mean roof height) 171160 EXPOSURE D 9'x 7' Door=+35.8 -40.5 (1 story and max 15' 17-1160 EXPOSURE D 16'x 7' Door=+34.3 -38.3 mean roof height) ❑160 EXPOSURE D 9'x 7' Door=+40.4 -45.7 (2 story and max 30' 171160 EXPOSURE D 16'x 7' Door=+38.7 -43.2 mean roof height) ❑150 EXPOSURE B 9'x 7' Door=+21.3 -24.1 ❑150 EXPOSURE B 16'x 7' Door=+20.4 -22.7 171150 EXPOSURE C 9'x 7' Door=+25.8 -29.2 (1 story and max 15' 17150 EXPOSURE C 16'x 7' Door=+24.7 -27.5 mean roof height. ❑150 EXPOSURE C 9'.x 7' Door=+29.9 -33.8 (2 story and max 30' 71150 EXPOSURE C 16'x 7' Door=+28.6 .-31.8 mean roof height) ❑150 EXPOSURE D 9'x 7' Door=+31.4 -35.5 (1 story and max 15' 0150 EXPOSURE D 16'x 7' Door=+30.0 -33.4 mean roof height) 17-1150 EXPOSURE D 9'x 7' Door=+35.4 -40.1 (2 story and max 30' ❑150 EXPOSURE D 16'x 7' Door=+33.9 -37.7 mean roof height) Notes: ■ Secure existing bucks per the Product Approval or Design Professional Instructions prior to installing the door. Have product approvals available at the time of inspection. Glazing in Garage doors must comply with R3012.1.2 (Glazing must be impact resistant or shuttered) Miami Dade N.O.A or Florida Product Approval# I