Loading...
HomeMy WebLinkAboutDrawing ---------------- - -------------------------------'-------------------- ---------------- -- --- Joy Moore,#8847635 250 Bimini Dr- °` Fort Pierce, FL,34949 Replacing 4 windows size for size with impact. Thecost of the job is 2.3% of the structures'assessed i value. i Line Item Single Hung Window 37"x 75" Living Roorri FL 1435-4 +32-1,-42.0 Line Item 1. Single Hung Window 37 x 75" Living Room FL 1435.4 +32-1, -42.0 Line Item 'I Single Hang Window 37"x 75" Living Room . . FL 1435.4 - +32-1,-42-0 Line items 1,2, and 3 are being mulled together using NOA 14-110.5.01. Line Item 4 Single Hung Window 531139". Kitchen FL 1435-4 +32-7,-43.3 Company: The Home Depot At Home Services Job Description: Replacing 4 windows size fc - Prepared By: Amber Client Name:" Moore Project Number: 8847635 •Version 10 0 - c 01 Structures Jnte naLoaal,LLCE% r�r.s- N,p WA�� Conforms with ASCE 7 10 „ ,:,tea•. �:x.,.w .. t DESIGN PRESSURES FOR WALL COMPONENTS&CLADDING _q ay Design Data Building Data Wind Velocity(mph) 160 Mean Roof Height 13 Risk Category 2 Building Width(ft) 61 Exposure_Category C Building Length(ft) 56 Directionality Factor 0.85 Roof Slope (x:12) 4 Internal Pressure Coefficient+/- 0.18 Design pressures listed below are: Allowable Stress OPENING OPENING LOCATION OPENING OPENING DIMENSIONS MAXIMUM POSITIVE MAXIMUM NEGATIVE MARK DESCRIPTION ZONE. ELEVATION WIDTH(INCHES) HEIGHT(INCHES) PERSSURE(PSF) PRESSURE(PSF) 1 5500-SH 5 5 37 75 32.1 -42.0 2 5500-SH 5 5 37 75 32.1 -42.0 3 5500-SH 5 5 37 75 32.1 -42.0 4 5500-SH 5 5 53 39 32.7 -43.3 Width of End Zone(a)in feet= 5.2 h + � 5 e Y sTRUCTuRCS t�s ER'#ATtC)F1AL,LLC ; • Ttraa3r� r^tc xv w..:.,,.cs.F,w'1crs-." 12/30%2015 11:56'AM