HomeMy WebLinkAboutDrawing ---------------- - -------------------------------'-------------------- ---------------- -- ---
Joy Moore,#8847635
250 Bimini Dr-
°` Fort Pierce, FL,34949
Replacing 4 windows size for size with impact.
Thecost of the job is 2.3% of the structures'assessed
i value.
i
Line Item
Single Hung Window
37"x 75"
Living Roorri
FL 1435-4
+32-1,-42.0
Line Item 1.
Single Hung Window
37 x 75"
Living Room
FL 1435.4
+32-1, -42.0
Line Item 'I
Single Hang Window
37"x 75"
Living Room . .
FL 1435.4
-
+32-1,-42-0
Line items 1,2, and 3 are being mulled together using
NOA 14-110.5.01.
Line Item 4
Single Hung Window
531139".
Kitchen
FL 1435-4
+32-7,-43.3
Company: The Home Depot At Home Services Job Description: Replacing 4 windows size fc
-
Prepared By: Amber
Client Name:" Moore Project Number: 8847635
•Version 10 0 -
c 01 Structures Jnte naLoaal,LLCE% r�r.s- N,p WA�� Conforms with ASCE 7 10
„ ,:,tea•. �:x.,.w .. t
DESIGN PRESSURES FOR WALL COMPONENTS&CLADDING
_q
ay
Design Data Building Data
Wind Velocity(mph) 160 Mean Roof Height 13
Risk Category 2 Building Width(ft) 61
Exposure_Category C Building Length(ft) 56
Directionality Factor 0.85 Roof Slope (x:12) 4
Internal Pressure Coefficient+/- 0.18
Design pressures listed below are: Allowable Stress
OPENING OPENING LOCATION OPENING OPENING DIMENSIONS MAXIMUM POSITIVE MAXIMUM NEGATIVE
MARK DESCRIPTION ZONE. ELEVATION WIDTH(INCHES) HEIGHT(INCHES) PERSSURE(PSF) PRESSURE(PSF)
1 5500-SH 5 5 37 75 32.1 -42.0
2 5500-SH 5 5 37 75 32.1 -42.0
3 5500-SH 5 5 37 75 32.1 -42.0
4 5500-SH 5 5 53 39 32.7 -43.3
Width of End Zone(a)in feet= 5.2
h
+ � 5 e
Y
sTRUCTuRCS t�s ER'#ATtC)F1AL,LLC ;
• Ttraa3r� r^tc xv w..:.,,.cs.F,w'1crs-."
12/30%2015 11:56'AM