Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL 12(iF3.�!:3 IF'ikmrii�IlEluil�Jim,�i tpmiimzn RLIEb 190y--W JAN 0 8 2016 - Business 0 Professional Regulation' FlolidaDepalrtmentof Eau>sr+rarr, I!Lc-gr�n I'�urHLE sarr�.ts�la-g.! I S1tdts&iTw= I Rae+!b.ztaas l F=- rI wmt� Busines PNessi I � g - -,Uri::F1uliiEirWhter Regulation ProductApproval Menu>Product or Application Search-,Application List> irmaC!=l L-'=1 e • FRL fi1Lt 9S74HR2n AWiCabjerm IFWP� Frniisicmn VW Sia ism 21DtL4 AWl1±at1LW Comments Archived L! Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo, OH 43659 (740) 404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg,keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo, OH 43659 (419) 376-8360 mel.sancrantCaa)owenscornig.com i Quality Assurance Representative Address/Phone/Email Category Rooting Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed Robert J.M. Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 08/20/2017 Validated By John W. Knezevich, PE Rj Validation Checklist- Hardcopy Received Certificate of Independence FL10674 R11 COI 2015 01 COI Nieminen.ndf Referenced Standard and Year(of Standard) Standard Year 45T114 D3161 2009 ASTM D3462 2009 ASTM D7158 2008 Equivalence of Product Standaras Certified By Sections from the Code https://floridabuilding-org/pr/pr_app_o.aspx?param=wGEVKQwtDgtBNbEY5l/p/`2boOT%2b6w7aliReglCQ8ur— 6ixEAOdgjxUlZosQ%a3d°ae3.d 1/2 Florida Buildirlo Code Online Product Approval Method Method 1 Option : Date Submitted 10/15/20_x. Date Validated 10/19/2015 Date Pending FBC Approval 10/20/2015 Date Approved 12/15/2015 Si a3T-9T.?ff0th7Cts E:L;# alr IAaa m Des—kNMI-10 1IMF/X1.11 (R%aa 3¢iMM ITT migoild tt Rw&rmg 3r d, ,5--tatY),l i ata$,st a tti it arrctt l:rij;u lip iri e 19hr t)2s aid Seater s"'id€Iz}ie5 iii S ag use R35t1P_ftff=Rimsbucurms riBdfta-,tm-ImIdY€Z::No FL10674 Rll II 2015 10 FINAL ER OC ASPHALT €wesaaudskLe H011:13-1-Was SHINGLES FL10674-Rll.pdf Fmpaclt R ma:W//A U'fta iPiEdl 1y::Rdbe ttll.MI.Wi mimeo RE-513T�ia D • - LV___ !//!A rimEltd ky�-ah-rd Pa74::-Yes FmTer tlm FAIR,SEdtwn S. E% aam i mm FL10674 R11 AE 2015 10 FINAL ER OC ASPHALT SHINGLES FL10674-R11.Ddf Back Next Contact Us:: 1940 North Monroe Street,Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement:: Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request do not send electronic mail to ttzs erlit•/.Isxtead,contact the office by phone or by traditional mail.If you have any questions,,please contact 850.487.1395.*Pursuant to Secwr. 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.most provide the Department with an email address If they have one.The emails provided may be used for official communication with the licensee.however email addresses are public record.It you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please dick here. Product Approval Accepts: ®recm , 5LCUritVm1:T1ucs• httpsl/floridabdiding.org/pr/pr app Od.aspx?param=wGEVXQwtDgtBNbEY5V%2boQTg/o2b6w7ahReglCQ8ucR6ixEAOdgtxUj3osQ°/pad°/g3d 212 EXTERIOR RESEARCH&DESIGN,LLC. Certificate of Authorization#9503 TRINITY ERD 353 CHRISTIAN STREET,UNIT#13 OXFORD,CT 06478 PHONE:(203)262-9245 FAX:(203)262-9243 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12-116 One Owens Corning Parkway FL10674-R11 Toledo,OH 43659 Date of Issuance:02/06/2012 Revision 6: 10/15/2015 SCOPE This. Evaluation Report is issued_ under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen.P.E.for use of the product under the Florida Building Code and Florida Building Code, Residential Volume.. The products described herein have been evaluated for compliance with the 5P Edition(2014)Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABEUNG: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED CoNIPUANcE: This Evaluation Report is valid until such time as the named-product(s) changes, the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named.client constitutes agreement to notify,Robert Nieminenr P.E.:if the product changes or the referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words `TrinitylERD Evaluated" may be displayed. in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: �r RObertJ.M.Itlieminen,P.E. �, s-'^....•s✓�:.�` The faaimdesaala��e5^�rrasauIIYmr¢edbyRobert Prremmen. • .es s P.E.on 10/15/2015.This does not serve as an electroninRy signed Florida Registration No.59166,Florida DCA ANE1983 document signed,seated hardrepies have been transmitted to the Prodaa Approval Adm arra to the named client CEtmRU►TION OF INDEPENDENCE: 1. Trinity IERD does not have, nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation_ Neither Trinity)ERD nor Robert Nieminen,P.E_are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions.thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY I ERD €toosma SYs€ws EVAtuATloN- 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Owens.Corning Asphalt Roof Shingles,as produced by Owens Corning,have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Prope Standard Year 1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2009 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2008 3. REFERENCES: Enti Examination Reference Date UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007 UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC(TST-9628) Wind Resistance 11CA34308 02/18/2012 UL LLC(TST9628) Physicals&Wind Resistance 4786093137 02/01/2014 ULLLC(TST9628) Wind Resistance 4786126532 02/10/2014- UL-LLC(TST9628) Physical Properties Classification letter 02/13/2014 UL LLC(TST9628) Physical Properties Classification letter 10/02/2015 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation,R2453 Exp.08/20/2017 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles_ 4.1.1 Classic and Supreme'are fiberglass reinforced,3-tab asphalt roof shingles. 4.1.2 Berkshire are fiberglass reinforced,4-tab asphalt roof shingles. 4.1.3 Devonshire""are fiberglass reinforced,5-tab asphalt roof shingles. 4.1.4 Duration', TruDefinition' Duration®, Duration Premium Cool, TruDefinition Duration' Designer Color Collection,TruDefinition'Oakridge$,Oakridge and WeatherGuard®HP are fiberglass reinforced,laminated :asphalt roof.shingles. 4.2 Berkshire Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard' HP Hip.& Ridge Shingles,ProEdge Hip&Ridge-Shingles and DuraRidg&m Hip&•Ridge Shingles are fiberglass reinforced,hip and ridge asphalt roof shingles. 4.3 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMrmmoNS: 5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designerrof Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation. Report; refer to current Approved Roofing Materials Directory for fire ratings of this product_ Exterior Research and Des V4 UC_ Evaktation Report G37940.OP.1Z-€t6 Cerj*catenfAuthanzWwv ffi95W Ft30674-1111 Revision 6:10/15/2015 Page 2 of 7 TRIIOIIIY I ERD 5.4 unci Ciasssiicatio>7: 5.4.1 AU Owens Corning shingles noted herein are Classified in accordance with FBC Tables 3:507.2.7.1 and. 8905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable for us in all wind zones up to Vad=150 mph(Vast=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F, indicating the shingles are acceptable for us in all wind zones up to Vasd=150 mph (Vuit=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C.Rule 61G20-3. 6. INSTALLATION: 61 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Coming and shall hold current Florida Statewide Product' Approval,,or be Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four(4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: ➢ Berkshire'shingles require minimum five(5)nails per shingle. • WeatherGuard HP shingles require minimum six(6)nails per shingle. ➢ Devonshire""shingles require minimum six(6)nails per shingle. ➢ Starter Strip Shingle and.Starter Strip Plus require minimum five(5)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: Feltundedayment Deck Fettunderlayment Deck 8X"edhemd Weatherl0" Self-adhered underlaymem WeatherLocke Underlayment Dripedge edDrip edge Drip— g edga Nails located Nails located T-3'from eave 2"-3"from eave Install first Self-sealing adhesive Sell se&mg adhesive Starter St positioned along eave Install rpm pesWoneda1=9eave shingle with \ s7ith 6"rammed 6"removed `\ Starter Strip shingle overhangs eaves and rakes'/e t-1i" Stze4:r S "trop Phos ovedr2o9s eaves and rakes 114'-314" Exterior Research and Design,LLC.- Evaluation Report 037940.02.12-R6 Cert fm[e of Arrthoroation 49503 FU0674-RII Revision 6:10/15/2015 Page 3 of 7 TRINITY I ERD 6-2-6 C lirlimumNailing—Classic°&Supreme: Normal Mansard or Aroe para Normal Mansard or Area para Wind Areas High Wind desvnnos y Wind Areas High Wind desvanes y Area pare vientos normales Areas vientos f iertes Area para vientos normales Areas vientas fuertes t•tt• (A) tt•t• ft• z•t (B rz• t• l t' (Af t• t• z" (B ra. t. tz t tz t 5"Exposure 5 5/8"Exposure Exposieion Exposieibn 6.2.7 Minimum Nailing—Berkshire®: &,alant snip Seahnl snip La ttra de seRada La taa de s0kdor 8 W9 bf 9 Vf a 8 Yf 8 Vf 8 Yf Syr t" �" t" 1" r r r_ 0 T MOMN reor®gcement centeoto de Who astatto 6.2.8 Minimum Nailing—Devonshire"°: 4T Nails r r r a r r r r �1 r e r r 131 i3l: Nails Ten 1"Spots of Asphalt Roof Cement Exterior Researr hand Design,LLC. Evaluation.Repart 037940.02-U-R6 C—T-WeofAudw hudan13-9503 FLI0674-RII Revision 6:10/15/2015 Page 4 of 7 QTRINrryIERD 6.2-9 Mf iimum Maiiing — flurauian'31, T'ruDefinitiona Duration, FpsratfoW', Premium Cool "& TuDennition' Duration Desiener Color.Coligction: V 4 M Pattem6 Nag Mrsardardsteep Sbpe Wen Dehaer Surettl3o Espsmado4dwosPattern areaandtapoleutout. saeed� Area&dams WOP� de8davve • • • �� �saSuretbtArbpas� —'\ �teet'treaL SurePiara \ SueFlaip tasienn area areaw h ffi' �' _ Dreade r Dreads mos DIM Ir 5Y•"Expt � P&k 5 "bqwme 5,4puk.ai exposda�n Cdaraas 5r4prSga�expos m» 53u'Expassere 6aparame 55Aprdg.de a C.aarw 5'hpad7.deexposfafm 6.2.10 Minimum Nailing—TruDefinr"tion Oak3idge"Oakridge®: 4 NO Mem 6 Nat9 MOM Esquaw carr 4 davos Esaprema con'6 claws 1. y I<— TrMRS 5A r mm SEgmdddda&6sm;dg Cbsmts F�sd 518pdg 5517Eaposume Chxcs 55B"Exposate BWDsdckia&56/8pu'g. F sFa z+a 68/8peg 6-2.11 Minimum Nailing—Weathe7Guardg HP: sift vkW mum hmwnlr .4.. :�1• tit� 6.3 Hip&Ridge Shingles: 6.3.1 Installation of Berkshire'Hip and Ridge Shingles,High Ridge,Hip&Ridge with Sealant,WeatherGuard'HP' Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using four(4) nails per shingle. Installation of DuraRidgeim Hip.& Ridge Shingles shall comply with the manufacturer's current published instructions,using two(2)nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations,including the use of hand-sealing for wind warranties. Exterior Research and Design,LIf- Ewahradon Repart037M.02.124M Cerdflcu a of Aut6or&otfoa X9503 FUG6744LU Rev"ssian 6:10/S/ZGIS Page 5&7 QO TRINITY I ERD 63.2 Fasteners shall he in acmrdante with the manufacturer`s.published requirements,mut not less than FBC 2507.2.6.or 89052.5. Staples are not Nermitted. 6.3.3 Minimum Nailing—Berkshire's flip&Ridge and high Ridge: Fig.,9 q Figs.2 tIPE�a A Tiop!PxS_ STC'atf6csr $ A Wigs Mads \\\ 4 \ 1 I I r r rsp piece fag I r \\A A I 1 $' PRPse I' I 4 P I I r I I I I 1 A I I I I of F1 f�a VI I I I' . I I. I 6.3.4 Minimum Naiiing_Hip.&Ridge.with Seai.'a= r. WROM Fig.2-Wigg 74ind fastening Pattem K HAS) rim Shingle eat Discard12" 2o° E 2o° Sealant Strip Dine 12 6.3.5 Minimum Nailing—WeatherGuard®HP Hip and Ridge: Fig.A Fou.C Hips&Ridge Shieigle Fastening 4 4 A P �� 44 P i I tSaJ�' A6a[!s 4 i i 2' z• k,. A I I I I 1 1 I 3' 1 � Exterior Research,and Design,LLC. Evaluation Report 037940.02.12-R6 [erfWrofe ofAuthadmt€on#9303 FL10674-R21 Revision 6:10/15/2015 Gage 6 of 7 QoTwNffy ERD 6.3.6 Minimum Nailing-ProEdge Hip&Ridge Shingles: Prevailing Standard -11"— Wind Direction Scalarrt S4ri Fastening P Pattern .�� 6'Exposure rF -Ir 1" 12, 1 Sealant Fasten 711i 7s�i 6"Exposure Cover Exposed I{ Fasteners ir4th Roof Cement 6.3.7 Minimum Nailing—DuraRidgel Hip&Ridge Shingles: Note: The drawings below pertain to minimum, as-tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. prmAng Wind Dimcdon Top View Dir4aio6drnimntodjrtat Vueenplan DinoftnNHsntoprodominassto �" Vistasupertor tdah _^ ^ o Ozeeta Catsiwg liaaT cog i P 7. LABEuNG- 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. S. SuiLDiNG PERmrr REQ=ElV ms: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this'product. 9. MAmuFAcruR16l:G PLAWS: Contact the named QA entity for information ort which plants.produce products covered by Florida Rule 9N-3 QA requirements. Ila. QuALTy AssuRANCE ENTTrry: UL LLC—QUA9625;(414)248-6409;karen.buchmann@u1.com - END OF EVALUATION REPORT- Exterior Research and Design,LLC. Evaluation Report 037940.02.12;86 [ertrftcaW ofAuthorfrawn#9503 FLf0674-R21 Revision 6:10/15/2015 Page.7 of 7