Loading...
HomeMy WebLinkAboutDrawing i File COPY, 72" X 80" 1 REPLACE DOORS IN 1 OPENING ONLY. NEW DOORS TO BE IMPACT RESISTANT- HURRICANE SHUTTERS NOT REQUIRED. OPENING PRODUCT DESIGN OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS NO. WIDTH. HGT. FTG. ZONE POS. NEG. (N.O.A.#) POS. NEG. 1 1 72 80 40.00 4 37.3 40.7 FL15255.8 55.0 1 -55.0 FRONT ENTRY-LSMI REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS. NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS. ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 1/4" TAPCON SCREWS INTO CONCRETE WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS. SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES MEAN ROOF HEIGHT= 21 FT 8 IN GABRIEL RESIDENCE 9528 SHADOW LANE DOOR REPLACEMENT PLAN FORT PIERCE, FLORIDA