HomeMy WebLinkAboutProduct Approval Florida Building Code Online rage i of L
RE
CEI'.'^D .JAN 15 2016
rIN
"`
I �i [ r x : i �'�'��. '�
[� lip[° } lli � � 1 •,�sa sem'°{{
^ r r BC(S Home ;Log In User_Regist2tfon HOCTopicsSRk[pi5urcharge Stals&Facts Publications ;�fBC Staff I aC75 Site Map i Links Search
Busines, r;, NCLQQFF''�'''
Product Approval `
Professill�I }USER:Public User
I�Ecz���;iiori
Product Approval Menu,>Product or A000atian Search>Application Ll >Application Detail
Fl.# FL1654-R16
Application TyPe Revision
Code Version' 2014
Application Status Approved
Comments
Archived
Product Manufacturer POLYGLASS USA
Address/Phone/Email 150 Lyon Drive
Fernley,NV 89408
(570)384-1230 Ext 242
jakins@polyglass.com
Authorized Signature James Akins
jakins@polyglass.com
Technical Representative Steve Wadding
Andress/Phone/Email 150 Lyon Drive
Fernley,NV 98408
(602)363-7139
stevew@polyglass.com
Quality Assurance Representative James Akins
,Address/Phone/Email 555 Oakridge Road
Humboldt Industrial Pkwy
Hazleton,PA 18201
(800)894-4563
jakinsa lass.com
Category Roofing
\
Subcategory ModiFled Bitumen Roof System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
'Evaluation Report.Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nleminen
'the EvaluationReport
.Florida License PE-59166
Quality-Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 06/27/2016
Validated By John W.Knezevich,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL1654 R16 COI 2015 01 COI Nieminen Ddf
Referenced Standard and Year.(of Standard) Standard Year
ASTM D6162 2000
ASTM D6163 2000
,ASTM D6164 2005
ASTM D6222 2008
ASTM D6509 2009
FM 4470 1992
FM 4474 2004
https://wwW.floridabuilding.org/pr/pr_app_dtl.aspx?param=wU>✓VXQwtDgvgqu2w%2bn... 8/25/2015
rlonaa 13uI1u11Ig wuc v111111G
.Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 06/17/2015
Date Validated 06/23/2015
Date Pending FBC Approval 06/28/2015
Date Approved 08/18/2015
Summary of Products,
FL# Model,Number',or Name Description
1654:1: Polygiass SBS and APP SBS and APP modified bitumen roof systems
Modified Bitumen Roof
Systems,
Limits of Use. Installation Instructions
Approved for use in HVHZ:No F1.1654 R16 fi 2015 06 FINAL Al ER POLYGLASS MODBIT FL1654-
Approved for use outside HVHZ:Yes R16.nd
Impact Resistant:N/A Verifled By: Robert Nieminen PE-59166
Design Pressure:+N/A/-622.5 Created by Independent Third Party:Yes
Other:1.)The design pressure in,this Evaluation Reports
application relates to'one particular assembly FL1654 R16 AE 2015 06 FINAL ER POLYGLASS MODBIT FL1654-
over concrete.deck.Refer to the ER Appendix for iR 6.odf
other Systerns and deck types.2.)Refer to ER, Created by Independent Third Party:Yes
Section 5 for otherLimits.of Use.
Baric Next
Contact U5:;1940 North Monroe Street,Tallahassee Fl 32399 Phone:850-487-1824
The state of Florida Is.an.AA/EEO'employer•Cgnvfiaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::gerund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mall,If you have any questions,please contact 850.487.1395.'Pursuant to
'Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
theyhave one.The emaltsprovided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under
Chapter 455,F.S.,please click he er .
Product Approval Accepts:
• Z�1`eI�1
https://www.tior dabuilding.org/pr/pr_app_dtl.aspx?param=tivGEVXQwtDgvgqu2w%o2bn... 8/25/2015
TRIM ;Ede®
APPENDIX 1:ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE
Table Deck Application Type Description Page
1A-1 Wood New or Reroof(Tear-Oft) A-2 Mech.Attached"AnchorSheet,Bonded Insulation,Bonded Roof Cover 4
3A-2 Wood New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 5
16 Wood New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 5
iC Wood New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 6
1D Wood New,Reroof(Tear-Off)or Recover D Prelim.Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 6
1E-1 Wood New or Reroof(Tear-Off) E Non-Insulated,Mech:Attached Base Sheet(nails),Bonded Roof Cover 7-8
1E-2 Wood New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet(screws&plates),Bonded Roof Cover 8-9
-F Wood New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 9
�6 2A Steel or Conc. New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 10
2B Steel or Conc New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 11-12
2C Steel or Conc. New,Reroof(Tear-Off)or Recover D Prelim.Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 13-14
3A-1 Concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 15-18
3A-2 Concrete New or Reroof(Tear-Off) A-1 Bonded Temporary Roof,Bonded Insulation,Bonded Roof Cover 19-20-
3B Concrete New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 21
4A LWIC New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 22-23
4B LWIC New or Reroof(Tear-Off) A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 24
4C LWIC New or Reroof(Tear-Off) E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 25-27
5A CWF New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 28
5B CWF New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 29
5C CWF New,Reroof(Tear-Off)or Recover B Mech.Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 30
513 CWF New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,Bonded Roof Cover 30
5E CWF New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 30.
6A Gypsum New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 31732
68 Gypsum New,Reroof(Tear-Off)or Recover A-2 Mech.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 33
6C Gypsum New,Reroof(Tear-Off)or Recover C Mech.Attached Insulation,'Bonded Roof Cover 33
61) Gypsurii New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech.Attached Base Sheet,Bonded Roof Cover 33
7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 34-36
78 „_ Various Recover .R Non-Insulated,Bonded Base Sheet,Bonded Roof Cover 36
The following notes apply to the systems outlined herein:
1. The roof system evaluation herein pertains t6 above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements'to the satisfaction of the AHJ. Load'.resistance of the
roof deck shall be documented through proper codified and/or FBC Approvafdocumentation.
2. insulation/base sheet fasteners"shall'be of3ufficient length for the following deck engagement:
Wood: Minimum 0.75=inch penetration.
D Steel: Minimum 0.754ch penetration and engage the top flute of the"steel deck.
Y Concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions.
3. Unless otherwise noted,insulation may be any one layer or combination of polyisocyanurate, polystyrene,wood fiberboard,perlite,gypsum-based roof board or mineral-wool roof board that meets-the QA
requirements of F.A.C.Rule 61G20-3 and is documented as meeting FBC 1505.1 and,for foam plastic,FBC Chapter 26,when installed with the roof cover.
Exterior Research and Design,I.I.C.d/b/a Trinity IERD 'Evaluation'Report 139290.02.08-1114 for FL16547R16
Certificate of Authorization#9503 Revision 14:06/17/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 1 of 36
TRINITY,ERD
4. Minimum 200 psi,minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D(mechanically attached base sheet,bonded roof cover),whereby the base
sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and
structural members shall be in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
5. Unless otherwise noted,insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application;the ribbons/beads shall expand as noted in the manufacturer's published instructions.
D HA(HA): Full coverage at 25-30 lbs/square.
➢Dow Insta-Stik Roofing Adhesive(D-IS): Continuous 0.75 to 1-inch wide ribbons,12-inch o.c.
➢ivlillennium One Step Foamable Adhesive(M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons,12-Inch o.c.
D OMG OlyBond 500(08500): Continuous 0.75 to !-inch wide ribbons,12-inch o.c. (PaceCart or SpotShot). Note: OlyBond Green may be used where OlyBond 500 is
referenced.
➢OlyBond Classic(OB Classic): Full coverage at 1 gal/square.
D 3M CR-20: Continuous 2.5-3.5-inch wide ribbons,12-inch o.c.
➢Note: When multiple loyers(s)of insulation and/or coverboard are installed in ribbon-applied adhesive,adhesive ribbons shall be staggered from layer-to-layer a distance of one-half the ribbon spacing.
D Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be notless than one-half the specified ribbons spacing.
6. Unless otherwise noted,all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum
Design Pressure(MDP)limitations. In no case shall these values be used to'increase'the MDP listings in the tables;rather if MDP listing below meets or exceeds that listed for a particular system in the tables,then
the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table:
➢Millennium One Step Foamable Adhesive(M-OSFA): MDP -157.5 psf (Min.0.5-inch thick)
D OMG OlyBond 500(OB500): MDP -45.0 psf (Min.0.5-inch thick Multi-Max FA-3)
➢OMG OlyBond 500(08500): MDP -187.5 psf (Min.0.5-inch thick ISO 95+GL)
D OMG OlyBond 500(08500): MDP -315.0 psf (Min.0.54nch thick'ENRGY 3)
D OMG OlyBond 500(OB500): MDP -487.5 psf (Min.0.5-inch thick ACFoam Ii)
➢3M CR-20: MDP -117.5 psf (Min.1.0-inch thick)
7. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft.
8. For mechanically attached-components or partially bonded insulation,the maximum design pressure for the selected,assembly shall.meet or exceed the:Zone 1 design pressuredetermined in accordance with"FBC
Chapter 16,and Zones 2 and 3 shall employ an attachment density designed by.a qualified,design professional to resist the elevated pressure criteria. Commonly used methods are'RAS 117 and FM LPDS11-29.
Assemblies marked with an asterisk*carry the limitations set forth in Section 2.2.1.5.1(a)of,FM LPDS 1-29 for,Zone 2/3 enhancements.
9. For fully bonded assemblies,the maximum design pressure forthe selected assembly shall meet or exceed critical design-pressure determined in accordance with FBC Chapter 16,and no rational analysis is permitted.
10. For mechanically attached'components over existing decks,fasteners shall be tested in the.existing deck for withdrawal resistance. "A qualified design professional shall review the'data for comparison 10 the
minimum requirements for the system.Testing and analysis shall be in accordance with TAS 105 orANSI/SPRI FX71.
11. For existing substrates in a bonded"recover installation,the existing roof systemahall"be:examined for.compatibility and:bond performance with the selected adhesive,and the existing:roa.system.shall,be capable of
resisting project design pressures<on its own merit to the satisfaction of the AHJ,as documented.through field uplift-testing in accordance with ASTM E907,FM LPDS 1-52,ANSI/SPRI IA-1 or TAS'124.
12. For Recover-Applications,using System Type D,the insulation is optional;however;the existing roof system shall be suitable for a recover application..
13. LWIC shall'be cast in accordance with FBC Section 1917 to the satisb6on ofthe Authority Having Jurisdiction. For systems where""speciflcd.WIC is referenced refer.to current:LWIC Product Approval for specific deck;
construction and-limitations. Foe systems-where specific LWIC is not referenced;the minimum design mix shall be 300 psi:.l'n all cases,the minimum top-coat thickness is 2-inches. For LWIC over structural concrete,
reference is made.to FBC Section 1917.4:1,Point 1.
Exterior Research and Design;LLC.d/b/a Trinity I ERD Evaluation Report P9290.02.08-R14 forFL1654-R16
Certificate of Authorization#9503 Revision 14:06/17/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 2 of 36
41
TRI ERE
14. Unless otherwise noted,refer to the following references for bonded base,ply or cap sheet applications.
TABLE 1:POLYGLASS ROOF COVERS
Reference Layer Material Application
BP-AA Base Polyglass G2 Base,FBC Approved ASTM D4601,Type II
HA at 20-40 lbs/square
(Base and Ply sheets,Asphalt-Applied) Ply Polyglass Ply IV,Polyglass Ply VI,FBC Approved ASTM D2178,Type IV or VI
SBS-AA Base or Ply Elastobase,Elastobase Poly,Elastoflex V,Elastoflex S6,Polyglass HT Base 650
(SBS,Asphalt-Applied) Cap Elastoflex 56, Elastoflex S6 G, Elastoflex S6 G FR,Elastoshield TS-G,Elastoshield TS-G FR,Polyfresko G SBS(sand-backed), HA at20-0Olbs/square
Polyfresko G SBS FR(sand-backed)
SBS TA Base or Ply Elastoflex V,Elastoflex S6
Elastoflex V,Elastoflex S6,Elastoflex S6 G,Elastoflex S6 G FR,Elastoshield TS-G,Elastoshield TS-G FR,Polyfresko G SBS(poly- Torch-Applied
(SBS,Torch-Applied) Cap film backed),Polyfresko G SBS FR(poly-film backed)
SBS-SA Base Elastoflex SA V Base,Elastoflex SA V FR Base,Elastoflex SA V Plus,Elastoflex SA V Plus FR
ioT SBS,Self-Adhering)g) Cap Elastoflex SA P,Elastoflex SA P FR,Polyreflect Self-Adhering
APP-TA Base or Ply Polyglass APP Base,Polyflex,Polybond
(APP,Torch-Applied) Cap Polyflex,Polyflex G,Polyflex G FR,Polybond,Polybond G,Polyfresko G,Polyfresko G FR Torch-Applied
APP-SA
Cap Polyflex SA P,Polyflex SA P FR,Polyfresko G SA,Polykooi Self-Adhering
(APP,5elf-Adhering)
15. Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind,load performance. 'Refer to current Roofing Materials Directory for fire ratings
associated with coating usage.
D PG200 Non Fibered Roof Coating;
• PG300 Fibered Roof Coating;
➢ PG600 Non-Fibered Aluminum Roof Coating;
D PG650 Fibered Aluminum Roof.Coating;
D PG700 High Quality Elastomeric Roof Coating;
➢ PG800 Asphalt Emulsion Roof Coating;
D Polyplus 60 Premium Non-Fibered Aluminum Roof Coating;
➢. Polyplus 65 Premium Fibered Aluminum Roof Coating;
Polybrite 70 Premium Grade Elastomeric Roof Coating;
D Polybrite 90 High Solids S1licone.Roof'Coating or Pelybrite 95 Silicone Roof Coating.
16_ The following represent priming requirements for_gypsum-based coverboards:
Dens Deck and Dens`Deck'Prime shall be field-primed,with PG100 prior to self-adhering or torch-applied membrane application. No priming is required;for hot-asphalt membrane applications.
D SECUROCK Gypsum-Fiber Roof Board does not require field priming for any membrane application.
17. "MDP--_Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads.Refer to FBC 1609 for determination of design wind loads.
Exterior Research and Design,LLC d/b/a Trinity IERDEvaluation Report P9290.02.08-1114 for F11654-1116
Certificate of Authorization#19503 'Revision 14:06/17/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 3 of 36
�t
TABLE IE-2:WOOD DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)onREcoveR
SYSTEM TYPE E:NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET(SCREWS&PiATEs),BONDED ROOF COVER
System Deck(See Base Sheet Roof Cover
No. Note i) Base Fasten Attach Ply Cap MDP(psf)
Min.15/32- OMG#12 Standard Roofgrip or OMG#14 Heavy 6-inch o.c.at 4-inch lap and 6-inch o.c.in
W 43 Polyglass APP Base Duty(min.1-5/8-inch long)with OMG 3"Round (Optional)APP-TA APP-TA -90.0
inch plywood Metal Plates or OMG Flat Bottom Metal Plates three,equally spaced,staggered center rows
Min.15/32- OMG#12 Standard Roofgrip or OMG#14 Heavy 6-inch o.c.at 4-inch la and 6-inch o.c.in
W 44 Elastobase(with sand top surface) Duty(min.1-5/8-inch long)with OMG 3"Round P (Optional)BP-AA,SBS AA, SBS AA,SBS-TA -90.0
inch plywood Metal Plates or OMG Flat Bottom Metal Plates three,equally spaced,staggered center rows SBS TA or APP TA or APP-TA
W-45 Min.15/32- Elastobase(with sand top surface) Trufast#12 DP or Trufast#14 HD(min.1-5/8-inch 6-inch o.c.at 4-inch lap and 6-inch o.c.in
(optional)BP-AA or SBS-AA SBS AA 90.D
inch plywood long)with Trufast 3"Metal Insulation Plates three,equally spaced,staggered center rows
Min.15/32- OMG#12 Standard Roofgrip or OMG#14 Heavy 6-inch o.c.at 4-inch lap and 6-inch o.c.in five,
W 46 inch I Polyglass APP Base Duty(min.1-5/8-inch long)with OMG 3"Round
plywood P equaly spaced,staggered center rows
(Optional)APP TA APP TA -120.0
Metal Plates or OMG Flat Bottom Metal Plates
Min.15/32- OMG#12 Standard Roofgrip or OMG#14 Heavy 6-inch o.c.at 4-inch la and 6-inch o.c.in five,
W 47 Elastobase(with sand top surface) Duty(min.1-5/8-inch long)with OMG 3"Round P (Optional)BP-AA,SBS-AA, or APP,585 TA -120.0
Inch plywood' Metal Plates or OMG Flat Bottom Metal Plates equally spaced,staggered center rows SBS TA orAPPTA or APP TA
W-48 Min.15/32- Elastobase(with sand top surface) Trufast#12 DP:orTrufast#14 HD(min.1-5/8-Inch 6-inch o.c.at 4-inch lap and 6-inch o.c.in five,
inch plywood long)with Trufast 3"Metal Insulation Plates equally spaced,staggered center rows (Optimal)BP-AA or 565-AA SBS AA 120.0
TABLE 1F:WOOD DECKS—NEW CONSTRUCTION.oR REROOF(TEAR-OFF)
SYSTEM TYPE F:NON-INSULATED,BONDED ROOF COVER
System Deck(See Roof Cover
No. Note 1) Primer MDP(psf)
Joint Treatment Base Ply Cap
Min.15/32- (Optional)SBS-SA,SBS- SBS-SA;APP-SA,SBS-
W-49 inch plywood (Optional)PG100 None SBS SA
TA.APP-TA TA,APP TA -90.0
Min.15/32- (Optional)One'or.more
W-50 inch plywood (Optional)PGSOD None PolyflexSABasg APP-TA AFP:TA -90A
Nl-51
Min.15/32- Plywood joints are covered wlthA-inch wide strips of Elastoflex SA V Plus,rolled into Elastoflex SA V Base or (Optional)SBS-SA,SBS- SBS-SA,APP-SA;SBS-
inch plywood (Optional)PG100 place to create continuous bond. Elastoflex SA V FR'Base TA,APP:TATA,APP.-TA 97.5
Min.15/32- Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus,=rolled into Elastoflex SA V Plus or (Optional}SBS SA,5B5 SBS-SA;APP-SA,
Inch SBS
W 52 )plywood- (Optional PG100
, -place to create continuous bond. Elastoflex SA V Plus FR TA,AP.P-TA TA,APP-TA -135.0
'W-53 inch plywood (Optional)PGS00 place to cmin.151,12- Plywood�eate cmtmous bandints are covered 4 inch;wide strips of,Elastoflex SA V Plus,lolled.into Polyfiex SA Base (Optional)One:ormore APA-TA -135:0'
Exterior Research and Design,LLC:d/b/a Trinity(ERO Evaluation Report P9290.02.08-R14.forFL1654-1116
certificate of Authorization#9503 Revision 14:06/17/2015
' Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 9,of 36