HomeMy WebLinkAboutProduct Approval Florida Building Code O Page 1 of 2
RUMP-0 JAN 15 2016
•
BCIS Home Log in User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff i BCIS Site Map Links Search
Business pfe��$
Pro' i }USER:Puber�
ssionalc0p�
..- Product Approval Menu>Product or A Dlicatio Sea ch>Application Lis[>Application Detail
FL# FL10674-R10
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer Owens Coming
Address/Phone/Email One Owens Corning Parkway
Toledo,OH 43659
(740)404-7829
greg.keeler@owenscoming.com
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Coming PKWY
f Toledo,OH 43659
(419)376-8360
mel.sancr-.int@owenscomig.com
Quality Assurance Representative
Add ress/Pho ne/E mail y
i
Category Roofing
Subcategory I Asphalt Shingles
Compliance Method II Evaluation Report from a Florida Registered Architect or a Licensed
I Florida Professional Engineer
Evaluation Report-Hardcopy Received
I
Florida Engineer or Architect Name wh developed Robert I.M. Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 08/20/2017
Validated By ( John W. Knezevich,PE
f
;� Validation Checklist- Hardcopy Received
I
Certificate of IndependenceFL10674 R10 COI 2015 01 COI Nieminen,pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 2009
ASTM D3462 2009
ASTM D7158 2008
G
Equivalence of Product Standards
Certified By I
Sections from the Code
I
littn://www.floridabuildina.ora/r)r/pr am) l,dtl.asux?param==-�vGEVXQwtDgtBNbEY5V%2... 9/15/2015
Florida Building Code Online Page 2 of 2
i
i
Product Approval Method I Method 1 Option D
Date Submitted 04/22/2015
Date Validated i 04/23/2015
Date Pending FBC Approval 04/25/2015
Date Approved 06/23/2015
Summary of Products i
FL# Model,Number or Name Description
10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab,S-tab,laminated,starter and hip&ridge
Shingles and Starters shingles
Limits of Use I Installation Instructions
Approved for use in HVHZ:No FL10674 R10 II 2015 04 FINAL ER OC ASPHALT
Approved for use outside HVHZ:�es SHINGLES FL 10674-1110.pdf
Impact Resistant:N/A Verified By: Robert].M. Nieminen PE-59166
Design Pressure:N/A Created by Independent Third Party:Yes
Other: Refer to ER,Section 5. Evaluation Reports
FL10674 R10 AE 2015 04 FINAL-ER-OC ASPHALT
SHINGLES FL10674 R10.odf
Created by Independent Third Party:Yes
Back Next
Contact Usj::1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.ICoovriaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public cords.If you do not want your e-mail address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact tiia office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.`Pursuant to
section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Dep irtment with an email address which can be made available to the public.To determine if you are a licensee under
lC Chapter 455,F.S.,please click here.
Product Approval Accepts:
1
I
I
i
I
I
httD://www.floridabuildin-.ora/pr/pr app 'dtl.aspx?param=wGEVXQw-tDgtBNbEY5V%2... 9/15/2015
r
i
. I
EXTERIOR RESEARCH&DESIGN,I.I.C.
Certificate of Authorization#9503
_ j 353 CHRISTIAN STREET,UNIT#13
TRI ERD ! OXFORD,CT 06478
PHONE:(203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
Owens Corning ( Evaluation Report 037940.02.12-115
One Owens Corning Parkway FL10674-R10
Toledo,OH 43659 Date of Issuance:02/06/2012
Revision 5: 04/22/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with t1i e 5"Edition(2014) Florida Building Code sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingle
LABELING: Labeling shall be in accordance with the Gequirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by: .ttttf►;!!, —
c"r• 5 f� .�
Robert J.M.Nieminen P.E. ,�?r�gi'%...:.0;..t The facsimilesealapThisdg snotswas rvasaneleed by bertNiemiign,
, •:i,�*�t at-�.+` - P.E.on D4/22/2015.This does not serve as an electronically signed
=��""„prr`' document Signed,sealed hardro ies have been transmitted to the
Florida Registration No.59166,Florida DCA ANE2983 g a”
Product Approval Administmtorand to the named client
CERTIFICATION OF INDEPENDENCE: i
1. Trinity IERD does not have, nor does it intend toacquireor will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity)ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acq i ire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previo6s versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
}
I
i
l
ERD
I
ROOFING SYSTEMS EVALUATION:
i
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles,as produced by Owens Corning, have demonstrated compliance
with the following sections of the Florida 136ilding Code and Florida Building Code, Residential Volume through testing in
accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of
Use set forth herein. 4
2. STANDARDS:
Section PropertV Standard Year
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009
1507.2.7.1,R905.2.6.1 Wind ResistanceI ASTM D3161 2009
1507.2.7.1,R905.2.6.1 Wind ResistanceASTM D7158 2008
3. REFERENCES: I
Kn!!N Examination Reference Date
UL LLC(CER9626) Physicals&Wind Resistance File R2453,Vol.3 02/15/2007
UL LLC(CER9626) Physicals&Wind Resistance 20120516-112453 05/16/2012
UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC(TST9628) Wind Resistance 11CA34308 02/18/2012
UL LLC(TST9628) Physicals&Win Resistance 4786093137 02/01/2014
UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC(TST9628) Physical Properties Classification letter 02/13/2014
Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control k Service Confirmation,R2453 Exp.08/20/2017
4. PRODUCT DESCRIPTION: �!
4.1 Asphalt Shingles:
4.1.1 Classic and Supreme are fiberglass reinforced,3-tab asphalt roof shingles.
4.1.2 Berkshire are fiberglass reinforced,14-tab asphalt roof shingles.
4.1.3 Devonshire"are fiberglass reinforced,5-tab asphalt roof shingles.
4.1.4 Duration, TruDefinition Durationl, Duration Premium Cool, TruDefinition Duration Designer Color Collection,
TruDefinition®Oakridge,Oakridge Ind WeatherGuard HP are fiberglass reinforced,laminated asphalt roof shingles.
4.2 BerkshireW Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard® HP Hip & Ridge Shingles,
ProEdge Hip & Ridge Shingles and DuraRidgel Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt
roof shingles.
4.3 Starter Strip Plus and Starter Shingl i Roll are starter strips for asphalt roof shingles.
S. LIMITATIONS:
5.1 This is a building code evaluation.i Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for usE in the HVHZ..
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire
ratings ofthis product.
5.4 Wind Classification:
5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to
ASTM D3161,Class F and/or ASTM yP7158,Class H,indicating the shingles are acceptable for us in all wind zones up to
Vmd=150 mph(Vuit=194 mph). R er to Section 6 for installation requirements to meet this wind rating.
5.4.2 All Owens Corning hip&ridge shingles and Starter Strip Plus noted herein are Classified in accordance with FBC Tables
1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F,indicating the shingles are acceptable for us in all wind zones up to
Vwd=150 mph(V„It=194 mph). Refer to Section 6 for installation requirements to meet this wind rating.
Exterior Research and Design,I.I.C. I Evaluation Report 037940.02.12-R5
Certificote of Authorization 119503 � FL10674-R10
Revision 5:04/22/2015
Page 2 of 6
I
I '
I
I
I ;
i
TRINITY,
5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations
by a qualified design professional are required for conditions outside these limitations. Contact the shingle
manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shaI all have quality assurance audit in accordance with the Florida Building Code and
F.A.C.Rule 61G20-3.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be
Locally Approved per Rule 611320-3,!per FBC Sections 1507.2.3,1507.2.4 or R905.2.3.
6.2 Asphalt Shingles: I
6.2.1 Installation of asphalt shingles shall Icomply with the manufacturer's current published instructions, using minimum
four(4)nails per shingle in accordaRice with FBC Sections 1507.2 or R905.2,with the following exceptions:
Berkshire shingles require minimum five(5)nails per shingle.
➢ WeatherGuard6 HP shingles require minimum six(6)nails per shingle.
➢ Devonshire""shingles require`minimum six(6)nails per shingle.
Y Starter Strip Plus requires minjmum five(5)nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's:published requirements, but not less than FBC 1507.2.6 or
R905.2.5. Staples are not permitted
6.2.4 Where the roof slope exceeds 21'units vertical in 12 units horizontal, special methods of fastening are required.
Contact the shingle manufacturer for details.
6.2.5 Minimum Nailing—Classic®&Supreme:
Normal Mansard or Area para Normal Mansard or Area para
Wind Areas High Wind desvanes y Wind Areas High Wind desvanes y
Aran para vientos normaies Areas (lentos fuertes Area para vientos normaies Areas vientos fuertes
!"t�,�(A) ��.1"l FV 2"1 (s �zt z" z" 11"
l
121
(I� I
5"Exposure 55/8"Exposure
Exposition Exposition
6.2.6 Minimum Nailing—Berkshire°:
I
i
Sealant strip Sealant strip
to ilia de sellador Ca tha do seRador
�[ 14, —► a E--s e ►o •4-
lr-- --►ea ->o • )o�--- o
+ ,
t R Yt" 9 Vt'
i o
Z.. Asphah.roofing opment
Cernento de techo de asfafto
I
Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-115
Certificate of Authorization X9503 FU0674-R10
Revision 5:04/22/2015
Page 3 of 6
E
RINITY, RD
6.2.7 Minimum Nailing—Devonshire TI:
Nails
7
Nails Ten 1"Spots of Asphalt Roof Cement
6.2.8 Minimum Nailing—Duration®,Trul)I efinitionG Duration, Duration® Premium Cool&TruDefinition®Duration Designer
Color Collection:
4 Nail Pattern 6 Nail
Esquema do 4 clavos Pattern
-1
SumNaBlIbsteningare3rikith d 6 3q:;�
dzERPT Of
Area decfawsSuretbilO
ayjW�G th
Ainde
("wsrim
U7r,
5Y,"Exposure
Nails 55.4'i 11(posure
,94 paly.de expasid6n Claws SO Wg.de expos[66t?
WT Exposure Nails 5''x"Expt-sure
p Mfg.do e*p o sidtin Clams 5 i jw1g.de exposid6a
6.2.9 Minimum Nailing—TruDefinition'06kridgeO,OakridgeO:
4 Nail Pattern 6 Nail Pattern
Esquema con 4 clavos Esquema con 6 clavos
121
12-
"I,nn
5518"EAposure55)a"Exposure
apasid&i de 6 618puig. Nails Ex�,asiddn de 5 5610 pulg, 5 518"Expwuie Clavoc Nails 5 5/9"Exposu
clavas Exp asicI6 ri de 6518 pule. Exposic.**6n de 5 619 pula.
6.2.10 Minimum Nailing—WeatherGuardO HP:
Silnglo 511de View
esmo in Mdo 09co
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R5
Certificate of Authorization#9503 F1.10674-1110
Revision 5:04/22/2015
Page 4 of 6
6.3 Hip&Ridge Shingles:
6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, Hip & Ridge with Sealant, WeatherGuard• HP Hip and
Ridge Shingles and ProEdge Hip&Midge Shingles shall comply with the manufacturer's current published instructions,
using four(4)nails per shingle. Installation of DuraRidge—Hip&Ridge Shingles shall comply with the manufacturer's
current published instructions,usingtwo(2)nails per shingle. Refer to Owens Corning published information on wind
resistance and installation limitations,including the use of hand-sealing for wind warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or
R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing—Berkshire®Hip&Ridge and High Ridge:
i
Fig.I Fig.2
PrevailinDWnd %
f
TRS FY
6.3.6 Minimum Nailing-ProEdge Hip&Ridge Shingles:
Prevailing Standard
Wind Direction Sealant Strip `Y Patternn9
6"Exposure I• Z'-'1
1
\ 12' I Sealant
Fasten 71 \ 7 Exposure
Cover Exposed
Fasteners with
Roof Cement
6.3.7 Minimum Nailing—DuraRidgeT"Hip&Ridge Shingles:
Note: The drawings below pertain to minimum, as-tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
(i
a--Pro,a(ingN5ind DiruolcrdvTop Vie��
Diroaionnlmn +-ul
coduc 4+111 V(We
error
Dirocdcn dol vimto prc4-nimnto
., /cloy
STB .xC—
Nails k \moi % 6 nsCbs»inD Surclla�'
:_moi_
loa: I..._..1.
6.
o• I �I 8"
_I
ua
'f I
1
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table
1507.2.7.1/R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(414)248-6409;karen.buciimann@ul.com
- END OF EVALUATION REPORT-
I
I
I
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-115
Certifcgte of Authorizatlon#9503 FL10674-R10
Revision 5:04/22/2015
Page 6 of 6