Loading...
HomeMy WebLinkAboutEvaluation Report fte 'COPY, EXTERIOR RESEARCH&DESIGN,I.I.C. Certificate of Authorization#9503 TRINITY ERD 353 CHRISTIAN OXFORD,STREET, CT 6478 PHONE:(203)262-9245 FAX:(203)262-9243 EVALUATION REPORT Owens Corning Evaluation Report 037940.02.12-116 One Owens Corning Parkway FL10674-R1i Toledo,OH 43659 Date of Issuance:02/06/2012 Revision 6: 10/15/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5�h Edition(2014)Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named products) changes, the referenced . Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E.if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity)ERD Evaluated" may be-displayed in advertising literature..If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report-shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: gtL'ttle;rit,, Robert J.M.Nieminen P.E. ,,s,. •• The faalmileseal appearing wasauthorized byRobert Nieminen, i. WQ1la1.i•sta. P.E.on 10/15/2015.This does not serve as an electronically signed Florida Registration No.59166,Florida DCA ANE1983 document.Signed,sealed hardcoples have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinity)ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity)ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process.of the product. 5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E.are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. Florida Building Code Online Page 2 of 2 Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/15/2015 Date Validated 10/19/2015 Date Pending FBC Approval 10/20/2015 Date Approved 12/15/2015 Summary of Products FF Model,Number or Name Description Owens Coming Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge Shingles.and.Starters. ..... N mits of Use [FL10674 stallation Instructions pproved for use in HVHZ:No R11'II 2015 10 FINAL ER OC ASPHALT Approved for use outside HVHZ:Yes INGLES FL10674-R11.Ddimpact Resistant:NIA rified By:Robert 3.M.Nieminen PE-59166 Design pressure:N/A eated by Independent Third Party:Yes Other:Refer to ER,Section 5. Evaluation Reports FL10674 R11 AE 2015 10 FINAL ER OC ASPHALT SHINGLES L10674-1111. df - Created by Independent Third Party:Yes - Back Next Contact ::1940 North Monroe Street Tallahassee FL 32399 phone:850-487-1824 The State of Florida is an AA(EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.if you have any questions,please contact 850.487.1395. 'Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under chapter 455,F.S.,please dickej er . Product Approval Accepts: scY.vnIt JR4 CS, i TRINITY!ER® 6.2.6 Minimum Nailing—Classic®&Supreme: Norniol Mansard or Area paw Normal Mansard or Ana pan Wind Areas High Wind dosvanssV Wind Areas, High Wind desvanas y Area pan vientos nomuilss Areas visages frrertas Area pan vientos nominates Areae vhwws fbartas ++' +z u S"Exposure 5 518'Exposure Expoelef6n. Exposicidn 6.2.7 Minimum Nailing—Berkshire®: Sealant ship Sealanl'ship LtlradesaRsdor La*ados0h& e e-=► •e--f i t--> of AspheFiroufingau,--•►a 4----i e :04-►94-1-0 BVi" 8 Yf 9 Yf 8Yf } eVe a ve 8 Yf 8 w ,,.t. �•J �r . r r Cametlto do EatJio de ebteha 6.2.8 Minimum Nailing—Devonshire*'": 4V ,7 Nails 13!1' 4' �}� L• }y,• Ne 544 6:: Nails Ten l"Spots of Asphah Roof Cement Exterior Research and Design,I.I.C. Evaluation Report 037940.02.12-116 Certificate of Authorization#9503 FL10674-R11 Revision 6:10/15/2015 Page 4 of 7 �PTRRINIW`ERD 5.4 Wind Classification: 5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F and/or ASTM D7158,Class H,indicating the shingles are acceptable for us in all wind zones up to Vasd=150 mph(V„h=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161,Class F,indicating the shingles are acceptable for us in all wind zones up to Vasd=150 mph (V„it=194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C.Rule 61G20-3. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3,per FBC Sections 1507.2.3,1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four(4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: ➢ Berkshire shingles require minimum five(5)nails per shingle. ➢ WeatherGuard'HP shingles require minimum six(6)nails per shingle. ➢ Devonshire'shingles require minimum six(6)nails per shingle. ➢ Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. _ 6.2.4 Where the roof-slope,exceeds 21 units vertical in 12 units horizontal, special methods of,fastening are required. Contact the shingle manufacturer for details. 6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus: Feltundedayment -Deck Fekundedaymen Deck S~ered 11YwtherL15drt) Self-adhered undodeyment weatherLock# underhyment Drip Drip edge Ddpedge . awe mss. Nails located baited 2'�'from rave 2=3'from cave Install fust Self-sealing adhesive �e�e Starter Strip positioned along eave �art°rtrip�"s ed shingle with +.,. with r removed :+. 6"removed Starter Strip shingle overhangs eaves and rakes'/i-?'P SUM Sufp Flus overhangs eaves and rakes 114=3/4° Exterior Research and Design,U.C. Evaluation Report 037940.02.12-R6 Certificate ofAuthorization#9503 FL10674-R31 Revision 6:10/15/2015 Page 3 of 7