HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 3
� V, 17-7
r
Jia -Z. 1
FiOrida Capagment� BCIS Home j Log In 1 User Registration i Hot Topics ; Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map Links ; Search !
Bu )
sines,O
Professional@Product Approval
USER:Public User
Regulation
Product Approval Menu>Product or Application Search>Application List>Application Detail
FL# FL17022-R3
Application Type Revision
Code Version 2014
Application Status Pending FBC Approval
Comments
Archived ...
Product Manufacturer Extreme Metal Fabricators,LLC.
Address/Phone/Email 2160 SW Poma Drive
Palm City,FL 34990
(772)872-8034
tara@extrememetalfabricators.com
Authorized Signature James Buckner
jimmy@cbuckinc.net
Technical Representative Tara Faulkner
Address/Phone/Email 2160 SW Poma Drive
Palm City,FL 34990
(772)872-8034
tara@extrememetaIfabricators.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed James L. Buckner,P.E.@ CBUCK,Inc.
the Evaluation Report
Florida License PE-31242
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By Steven M. Urich,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL17022 R3 COI CertOflndeo.odf
Referenced Standard and Year(of Standard) Standard Year
TAS 125 2003
UL 1897 2004
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDa.v2aBQpHpQQ... 1/18/2016
Florida Building Code Online Page 2 of 3
Product Approval Method Method 1 Option D
Date Submitted 12/18/2015
Date Validated 12/18/2015
Date Pending FBC Approval 12/18/2015
Summary of Products
FL# Model,Number or Name Description
17022.1 (1)5-V Crimp 26 Gauge Steel,Lapped Roof Panel,Mechanically Attached to Wood
Deck.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R3 II 1 5VCrimo 26ga WoodDeck EVALREPORT.pdf
Approved for use outside HVHZ:Yes Verified By:James L. Buckner, P.E.@ CBUCK,Inc. P.E.#31242
Impact Resistant:No Created by Independent Third Party: Yes
Design Pressure:+N/A/-101 Evaluation Reports
Other:Refer to evaluation report for conditions FL17022 R3 AE 1 5VCrimo 26ga WoodDeck EVALREPORT.odf
and limitations of use. Refer to manufacturer's Created by Independent Third Party:Yes
installation instructions as a supplemental guide for
attachment.
17022.2 (2)5-V Crimp 0.032"Aluminum,Lapped Roof Panel,Mechanically Attached to Wood
Deck.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R3 rI 2 5VCrimo 032AIum WoodDeck EVALREPORT.pdf
Approved for use outside HVHZ:Yes Verified By:James L. Buckner, P.E.@ CBUCK,Inc. P.E.#31242
Impact Resistant:No Created by Independent Third Party: Yes
Design Pressure:+N/A/-168.5 Evaluation Reports
Other:Refer to evaluation report for conditions FL17022 R3 AE 2 5VCrimo 032A1um WoodDeck EVALREPORT.odf
and limitations of use. Refer to manufacturer's Created by Independent Third Party:Yes
installation instructions as a supplemental guide for
attachment.
17022.3 (3) 1.5"Mechanical Seam 2"Rib Height,16"Wide,24 Gauge Steel Roof Panel Mechanically
Attached to Wood Deck.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R3 II 3 1.5
Approved for use outside HVHZ:Yes MechSeam 24ga WoodDeck EVALREPORT.pdf
Impact Resistant:No Verified By:James L. Buckner, P.E.@ CBUCK,Inc. P.E.#31242
Design Pressure:+N/A/-191 Created by Independent Third Party:Yes
Other:Refer to evaluation report for conditions Evaluation Reports
and limitations of use. Refer to manufacturer's FL17022 R3 AE 3 1.5
Installation instructions as a supplemental guide for MechSeam 24ga WoodDeck EVALREPORT.pdf
attachment. Created by Independent Third Party:Yes
17022.4 (4) 1.5"Mechanical Seam 2"Rib Height, 16"Wide,0.032"Aluminum Roof Panel Mechanically
Attached to Wood Deck.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R3 II 4 1.5
Approved for use outside HVHZ:Yes MechSeam 032A1um WoodDeck EVALREPORT.pdf
Impact Resistant:No Verified By:James L. Buckner,P.E. @ CBUCK,Inc. P.E.#31242
Design Pressure: +N/A/-191 Created by Independent Third Party:Yes
Other:Refer to evaluation report for conditions Evaluation Reports
and limitations of use. Refer to manufacturer's FL17022 R3 AE 4 1.5
installation instructions as a supplemental guide for MechSeam 032A1um WoodDeck EVALREPORT.pdf
attachment. Created by Independent Third Party:Yes
17022.5 (5) 1"Nail Strip 1"Rib Height, 16"Wide,26 Gauge Steel Roof Panel Mechanically
Attached to Wood Deck.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R3 II 5 1NailStrip 26ga WoodDeck EVALREPORT.pdf
Approved for use outside HVHZ:Yes Verified By:James L. Buckner,P.E.@ CBUCK,Inc. P.E.#31242
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/-97.25 Evaluation Reports
Other:Refer to evaluation report for conditions FL17022 R3 AE 5 1NailStrio 26ga WoodDeck EVALREPORT.pdf
and limitations of use. Refer to manufacturer's Created by Independent Third Party:Yes
installation instructions as a supplemental guide for
attachment.
17022.6 (6) 1"Nail Strip 1"Rib Height, 16"Wide,0.032"Aluminum Roof Panel Mechanically
Attached to Wood Deck.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R3 II 6 1NailStrip 032A1um WoodDeck EVALREPORT.pdf
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv2aB QpHpQQ... 1/18/2016
Florida Building Code Online Page 3 of 3
Approved for use outside HVHZ:Yes Verified By:James L.Buckner,P.E.@ CBUCK,Inc. P.E.#31242
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/-78.5 Evaluation Reports
Other:Refer to evaluation report for conditions FL17022 R3 AE 6 1NailStrio 032A1um WoodDeck EVALREPORT.Ddf
and limitations of use. Refer to manufacturer's Created by Independent Third Party: Yes
installation instructions as a supplemental guide for
attachment.
17022.7 (7) 1.5"Nail Strip 1.5"Rib Height, 19"Wide,26 Gauge Steel Roof Panel Mechanically
Attached to Wood Deck.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL17022 R3 II 7 1.5NailStrip 26cla WoodDeck EVALREPORT.odf
Approved for use outside HVHZ:Yes Verified By:James L. Buckner,P.E. @ CBUCK,Inc. P.E.#31242
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:+N/A/-63.5 Evaluation Reports
Other:Refer to evaluation report for conditions FL17022 R3 AE 7 1.5NailStrip 26aa WoodDeck EVALREPORT.pdf
and limitations of use. Refer to manufacturer's Created by Independent Third Party:Yes
installation instructions as a supplemental guide for
attachment.
Back Next
Contact Us::1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mall address released in response to a public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under
Chapter 455,F.S.,please click here.
Product Approval Accepts:
sccuritvmv riucv
�I
http://www.floridabuilding.org/pr/pr� app dtl.aspx?param=wGEVXQwtDgv2aB QpHpQ Q... 1/18/2016
NCBUCK Engineering
Specialty Structural EngtnpL=rtnq CBUCK,Inc.Certificate of Authorization#8064
Evaluation Report
"S-V Crimp"
Metal Roof Assembly
Manufacturer:
Extreme Metal Fabricators, LLC.
2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
for
Florida Product Approval
# FL 17022.1 R3
Florida Building Code Sth Edition (2014)
Per Rule 61G20-3
Method: 1 - D
Category: Roofing
Sub - Category: Metal Roofing
Product: 5-V Crimp Roof Panel
Material: Steel
Panel Thickness: 26 gauge
Panel Width: 24"
Support: Wood Deck
Digitally signed by James L Buckner,P.E.
Electronically signed and sealed documents
shall comply with the provisions of FAC Rule
61G15-23. `1t11111i111
Prepared by:
James L. Buckner, P.E., SECB ` ��s ,cerin
Florida Professional Engineer#31242 =*' No 31242 * '
Florida Evaluation ANE ID: 1916
Project Manager:Youry Demosthenes =70 w=
Report No. 15-217-5V-S6W-ER �,�'. STATE OF _40
(Revises 15-176-5V-S6W-ER) %mss' •FSO....ID ' �j�`�
Date: 12/18/15 �S;ONAL�����
Contents: -
Evaluation Report Pages 1—7
2015.12.18 10:53:51 -05'00'
CBUCK,Inc.,Palm Beach County,Florida
Phone:(561)491-9927-Email:cbuck@cbuckinc.net-Website:www.cbuckinc.net
FL#: FL 17022.1 R3
Date: 12/18/15
CBUCK Engineering Page rt No.:2 15-21
77-5V-56W-ER
Speclalty Structural EnglnL=L=rinq CBUCK,Inc.Certificate of Authorization#8064
Manufacturer: Extreme Metal Fabricators, LLC.
Product Name: S-V Crimp
Product Category: Roofing
Product Sub-Category Metal Roofing
Compliance Method: State Product Approval Rule 61G20-3.005 (1) (d)
Product/System 5-V Crimp Roof Panel, 26 gauge steel, 24" wide panel mechanically attached to
Description: Wood Deck with screws.
Product Assembly as Refer to Page 4 of this report for product assembly components/materials &
Evaluated: standards:
1. Roof Panel
2. Fasteners
3. Underlayment
4. Insulation Board (Optional)
Support: Type:
Wood Deck
(Design of support and its attachment to support framing is outside the scope of
this evaluation.)
Description:
• 15/32" or greater plywood,
• or Wood plank (min.specific gravity of 0.42)
Slope: Minimum slope shall be in compliance with FBC Chapter 15 Section 1507.4.2,
applicable code sections and in accordance with manufacturer's
recommendations.
Performance: Wind Uplift Resistance:
• Design Uplift Pressure (ASD): Refer to Table A
(Refer to"Table A" attachment details herein)
FL#: FL 17022.1 R3
Date: 12/18/15
RepoC SUCK I�r,e,�ir�eerir�q Pagert No•:3 of77-5V-56W-ER
Specildlfij Sf ructurall Englineerlinq CBUCK,Inc.Certificate of Authorization#18064
Performance The product described herein has demonstrated compliance with:
Standards: • UL580-06—Test for Uplift Resistance of Roof Assemblies
• UL 1897-04—Uplift test for roof covering systems
• TAS 125-03—Standard Requirements for Metal Roofing Systems
Code Compliance: The product described herein has demonstrated compliance with Florida Building
Code 5th Edition (2014),Section 1504.3.2.
Evaluation Report This product evaluation is limited to compliance with the structural requirements
Scope: of the Florida Building Code, as related to the scope section to Florida Product
Approval Rule 61G20-3.001.
Limitations and • Scope of"Limitations and Conditions of Use"for this evaluation:
Conditions of Use: This evaluation report for "Optional Statewide Approval" contains technical
documentation, specifications and installation method(s) which include
"Limitations and Conditions of Use"throughout the report in accordance with
Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is
the authority to approve products under"Optional Statewide Approval'.
• Option for application outside "Limitations and Conditions of Use"
Rule 61G20-3.005(1)(e) allows engineering analysis for "project specific
approval by the local authorities having jurisdiction in accordance with the
alternate methods and materials authorized in the Code". Any modification of
the product as evaluated in this report and approved by the Florida Building
Commission is outside the scope of this evaluation and will be the
responsibility of others.
• Design of support system is outside the scope of this report.
• Fire Classification is outside the scope of Rule 61G20-3, and is therefore not
included in this evaluation.
• This evaluation report does not evaluate the use of this product for use in the
High Velocity Hurricane Zone code section. (Dade & Broward Counties)
Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in
accordance with the Florida Building Code and Rule 61G20-3.005 (3) for
manufacturing under a quality assurance program audited by an approved quality
assurance entity through Keystone Certifications, Inc. (FBC Organization ID# QUA
1824).
FL#: FL 17022.1 R3
Date: 12/18/15
CE3UCK Engineering Page Report No.:4 -2177-5V-S6W-ER
Speclialty Structural Engineerincj CBUCK,Inc.Certificate of Authorization#8064
Components/Materials Roof Panel: 5-V Crimp
(by Manufacturer): Material: Steel
Thickness: 26 gauge (min.)
Panel Widths: 24" (max.) Coverage
Rib Height: 5/8"
Yield Strength: 40 ksi min.
Corrosion Resistance: Per FBC Section 1507.4.3
Fastener:
FASTENER 1 Used for Attachment Method 1
Type: Hex Washer Head Wood Screw
Size: #9 x 1-1/2" (min.)
Corrosion Resistance: Per FBC Section 1506.6 and 1507.4.4
Standard: Per ANSI/ASME B18.6.1
FASTENER 2 Used for Attachment Method Z 3 &4
Type: Hex Washer Head Wood Screw
Size: #10 x 1-1/2" (min.)
Corrosion Resistance: Per FBC Section 1506.6 and 1507.4.4
Standard: Per ANSI/ASME B18.6.1
Components&Materials: Underlayment:
(by Others) Material and application shall be in compliance with FBC Section 1507.4.5.1 and
1507.4.5.2, applicable codes and in accordance with manufacturer's
recommendations.
Insulation(Optional):
Type: Rigid Insulation Board
Thickness: 3" (max.)
Properties:
Density: 2.25 pcf(lbs/ft') min.
Or Compressive Strength: 20 psi min.
Insulation Notes:
• Rigid Insulation shall meet minimum density OR compressive strength.
• Insulation shall comply with FBC Section 1508.When insulation is incorporated,
fastener length shall conform to penetrate thru bottom of support a minimum
of 3/16".
FL#: FL 17022.1 R3
Date: 12/18/15
Repo
N I .
CBUCK Engineering Page rt No.:5 of 77-5V-S6W-ER
Specialty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064
Installation: Installation Method:
(Refer to"TABLE A" below and drawings at the end of this evaluation report.)
■ Fastener Spacing: Refer to "TABLE A" Below
(attached to the tops of the V's for a total of 3 screws across the width of the
panel.)
■ Row Spacing: Refer to"TABLE A" Below
(along the length of the panel)
■ Minimum fastener penetration thru bottom of support, 3/16".
■ For panel construction at the end of panels, refer to manufacturer's
instructions and any site specific design.
TABLE"A"
ALLOWABLE LOADS
METHOD 1: METHOD 2: METHOD 3: METHOD 4:
Design Pressure(ASD)*: -86 PSF -93.5 PSF -101 PSF -228 PSF
Row Spacing: 16"o.c. 16"o.c. 8" o.c. 6"o.c.
Fastener Spacing(across panel width): 12"o.c. 12"o.c. 12"o.c. 12"o.c.
Fastener Size: #9 #10 #10 #10
*Allowable design pressure(s)for allowable stress design(ASD)with a margin of safety of 2 to 1.
Install the 5-V Crimp roof panel assembly in compliance with the installation
method listed in this report and applicable code sections of FBC 5th Edition (2014).
The installation method described herein is in accordance with the scope of this
evaluation report. Refer to manufacturer's installation instructions as a
supplemental guide for attachment.
Referenced Data: 1. UL 580-06 &UL 1897-04—Uplift Test
By Architectural Testing, Inc.-West Palm Beach, FL
(FBC Organization#TST ID: 1527)
Report No.: D5893.01-450-18, Date: 05/02/14
Report No.: F3366.01-450-18, Date: 12/18/15
2. TAS 125—Uplift Test
By Architectural Testing, Inc.-West Palm Beach, FL
(FBC Organization#TST ID: 1527)
Report No.: D5893.02-450-18, Date: 07/22/14
3. Quality Assurance
Keystone Certifications, Inc. (FBC Organization IN QUA 1824)
Extreme Metal Fabricators, Inc. Licensee#974
4. Certification of Independence
By James L. Buckner, P.E. @ CBUCK Engineering
(FBC Organization#ANE 1916)
FL#: FL 17022.1 R3
Date: 12/18/15
CBUCK Engineering Page rt No.:6 15-21
77-5V-56W-ER
Specldlty Structural EnginL=erincj CBUCK,Inc.Certificate of Authorization#8064
Installation Method
Extreme Metal Fabricators, LLC.
5-V Crimp (26 gauge steel) Roof Panel attached to Wood Deck
Drawings
24" Maximum Net Coverage
5/8"
Panel Profile
Narrnal 12`as Nomireti 12'as
00 x 1-112' Mn. or #10 x 1-11l NrL perIbblre EX
Heat Wadw Head screw
Rene!oretiep Spwed
ReW la1el Wdlh
TWe W Spacing nA"Pand Lenp
Deck
- 15132°or Grier Ptywwd,or
- Wwd PW*
Typical Assembly Profile View
(Typical Fastening Pattern Accross Width - Interior)
FL#: FL 17022.1 R3
Date: 12/18/15
CBUCK Engineering Page rt No.:15ef 5V-17 -ER
SpeclaltLy Structural E=nglnL=L=rInq CBUCK,Inc.Certificate of Authorization#8054
Installation Method
Extreme Metal Fabricators, LLC.
5-V Crimp (26 gauge steel) Roof Panel attached to Wood Deck
Fasteners-
#9 x 1-1/2"Min. or
#10 x 1-1/2"Min. per Table"A" 5-V Crimp Roof Panel
Hex Washer Head Wood Screws
Deck:
15/32"or greater Plywood,or
-Wood plank
Typical Roof Assembly
Isometric View
(Optional) Rigid Insulation Board per Page 4 of this report
TABLE"A"
ALLOWABLE LOADS
METHOD 1: METHOD 2: METHOD 3: METHOD 4:
Design Pressure(ASD)*: -86 PSF -93.5 PSF -101 PSF -228 PSF
Row Spacing: 16"o.c. 16"o.c. 8"O.C. 6" o.c.
Fastener Spacing(across panel width): 12"o.c. 12" o.c. 12"o.c. 12"o.c.
Fastener Size: #9 #10 #10 #10
*Allowable design pressure(s)for allowable stress design(ASD)with a margin of safety of 2 to 1.