Loading...
HomeMy WebLinkAboutProduct Approval (3) tM1he'W>ron .9 Florida LepaItment! SCIS Home Log In User Registration Hot Topics I Submit Surcharge I Stats&Facts Publications I FBC Staff BCIS Site Map Links I Search j Busines *VUSER:ProfessibrralProduct Regulation Product ADDroVai Menu>Product or Application Search>Application List>Application Detail FL# FL16994-R4 Application Type Revision. Code Version 2014 Application Status Approved jt 4 ' k'a ? k , ' ' Comments v; Archived Product Manufacturer Southeastern Metals Mfg. Co. Address/Phone/Email 11801 Industry Drive Jacksonville, FL 32218 (904) 696-4682 jhkelsey@semetals.com Authorized Signature Jim Horton jwhorton@semetals.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Roofing Accessories that are an Integral Part of the Roofing System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer I Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Zachary R. Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/20/2015 Validated By Locke Bowden '�' Validation Checklist-Hardcopy Received Certificate of Independence FL16994 R4 COI SEM14001.4 2014 FBC Evaluation Report Off-Ridge Ven . df Referenced Standard and Year(of Standard) Equivalence of Product Standards Certified By Sections from the Code 1709.2 Product Approval Method Method 2 Option B Date Submitted 08/16/2015 Date Validated 08/20/2015 Date Pending FBC Approval 08/20/2015 Date Approved 10/16/2015 Summary of Products FL# Model,Number or Name Description 16994,1 Off Ridge Vent 4-ft, 6-ft, and 8-ft off ridge vents for use with asphalt shingles Limits of Use Installation Instructions Approved for use in HVHZ: No FL16994 R4 II SEM14001.4 2014 FBC Evaluation Renort Off- Approved for use outside HVHZ:Yes Ridoe Vent.odf Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: +0/-18 Created by Independent Third Party: Yes Other:See evaluation report for limits of use. Evaluation Reports FL16994 R4 AE SEM14001.4 2014 FBC Evaluation Renort Off-Ridoe Vent.Ddf Created by Independent Third'Party: Yes 16994.2 Tile Off Ridge Vent 4-ft, 6-ft, and 8-ft off ridge vents for use with clay or concrete tile Limits of Use Installation Instructions Approved for use in HVHZ: No FL16994 R4 II SEM14002.3 2014 FBC Evaluation Reoort Tile Approved for use outside HVHZ:Yes Roof Vent.Ddf Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: +0/-9 Created by Independent Third Party: Yes Other: See Evaluation Report for limits of use. Evaluation Reports FL16994 R4 AE SEM14002.3 2014 FBC Evaluation Reoort Tile Roof Vent.odf Created by Independent Third Party: Yes 6acls Nent Contact Us:: 1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer,copyright 2007-2013 State of Florida. :: Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please dick here. Product Approval Accepts: ® go M se!; .I su•:rriics Certificate of Authorization No.29824 CREEK 17520 Edinburgh Dr Tampa,Fl.33647 (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE 5TH EDITION(2014) Manufacturer: Southeastern Metals Manufacturing Co., Inc.(SEMCO) Issued August 16, 2015 11801 Industry Drive Jacksonville,FL 32218 (800)874-0335 htto://wwwsemetals.com Manufacturing Plant: Jacksonville, FL Quality Assurance:, UL LLC(QUA1743) SCOPE Category: Roofing Subcategory: Roofing Accessories that are an Integral Part of the Roofing System Code Sections: 1709.2 Properties: Roof Ventilation REFERENCES Entity Report No. Standard Year'' PRI Construction Materials Technologies(TST5878) SEM-029-02-01 ASTM E 330 2002 PRI Construction Materials Technologies(TST5878) SEM-031-02-01 ASTM E 330 2002 Zachary R.Priest,P.E.(CREEK Technical Services) SEM14003 Calculations 2014 PRODUCT DESCRIPTION AND APPLICATION ROOF FLANGE Off Ridge Vent: Minimum 26 ga.ASTM A792 or ASTM A653 CS Type B steel; Maximum dimensions of the vent are 24-inch wide x 102-inch long x 4.25-inch high. Vent is available in nominal 4-ft,6-ft and 8-ft sizes. Deck Type: Minimum 7/16-inch APA span rated OSB sheathing or 15/32-inch APA span rated plywood sheathing for new and existing roof deck (Deck shall be designed by others in accordance with FBC requirements). Roof slope: Minimum 2:12 Installation Height: Maximum 33-ft Roof Cut-Out: 2.5-inch wide x 42-inch opening for the nominal 4-ft vent 2.5-inch wide x 66-inch opening for the nominal 6-ft vent 2.5-inch wide x 90-inch opening for the nominal 8-ft vent SEM14001.4 FL16994-R4 Page 1 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use, or other product attributes that are not specifically addressed herein. Southeastern Metals Manufacturing Co.,Inc. CREEKOff Ridge Vent TECHNICAL SERVICES, LLC. Attachment Method:. Cut-out opening as prescribed above into the sheathing located a minimum 6-inch off the ridge. For a single vent, install the vent'as close to the center of the roof length as possible. Multiple vents should be evenly spaced along the roof length. Remove interfering shingle nails around the perimeter of the opening and any debris prior to placing vent. Apply ASTM D 4586 or ASTM.D 3409, Type I roofing cement/mastic to the underside of the perimeter flange to continuously surround and seal the flange. Position the vent over the opening in the roof sheathing. Slide the top and side flanges of the vent underneath the shingles and allow the bottom flange to lie on top of the shingles. Attach the vent with #9 x min. 1.5-inch HWH screws with 0.5- inch sealing washers or min. 12 ga. x 1-1/4-inch ring shank nails with min. 3/8-inch diameter heads having sufficient length to penetrate through the sheathing a minimum of%-inch. The fasteners shall be located 14nch from the edge of the flange and 5.5- inches o.c. along all four sides of the vent. All loosened shingles shall be adhered down with roof cement/mastic. When nails are used to attach the vent, all penetrations through the vent flange shall be sealed using ASTM D 4586 or ASTM D 3409, Type I roofing cement/mastic. Max- 102 in- lin . 3n > .f 3-in- % j / //i" 24 in. ZZ j 11FINUE011, Allowable Roof Coverings: Asphalt shingles Maximum Design -13.5 for 4-ft and 6-ft vents Pressure' (psf) -18 for 8-ft vent 'Pressures calculated using 2:1 margin of safety per 1504.9. LIMITATIONS 1) Fire Classification is outside the scope of this evaluation. 2) This report is not for use in the HVHZ. 3) The roof deck and deck attachment shall be designed by others in accordance with the 2014 FBC. 4) SEMCO vents shall be installed in strict compliance with this evaluation report and the manufacturer's published installation instructions. In the event of conflict,the more restrictive installation shall be enforced. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the.deck shall be checked for protrusion prior to installation. 6) Installation of the roof assembly is outside the scope of this evaluation. 7) SEMCO vents are intended to provide passive ventilation for an enclosed attic in residential construction applications 8) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. SEM14001.4 FL16994-R4 Page 2 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. Southeastern Metals Manufacturing Co.,Inc. CREEKOff Ridge Vent TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code 5t'Edition(2014)as evidenced in the referenced documents submitted by the named manufacturer. PRY R. pR iii �C E N No 74021 2015.08.16 14:48:33 9' STATE O F '�v (CJ`;�,-,,... .- ;��;•. o P 4 .:\��� -04'00' •. • R 1' ���� Zachary R. Priest, P.E. '��,��NA ,%%��� Florida Registration No.74021 Organization No.ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. END OF REPORT SEM14001.4 FL16994-R4 Page 3 of 3 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify-CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use, or other product attributes that are not specifically addressed herein.