Loading...
HomeMy WebLinkAboutProduct Approval R _ X016 R W Building Consultants, Inc. R E C Wi ' j� ]AN Consulting and Engineering Services for the Building Industry 17 C P.O.Box 230 Valrim,Fl.33595 Phone 813.659.9197 __. _-___ _----.---____-- ---------------._-- Florida Board ofPdMO'Jhal in -:Cerd cat Authoriration No.9813_---.--------------- —__-- ------------- ._--- _ _-- Noduct Evaluafioii ' Dale: Product Sub Category Manufacturer Product Name. Category Swinging Plastpro Inc. Glazed Fiberglass Double Door Exterior Exterior Door 5200 W CENTURY BLVD. Inswing/Outswing Doors Assemblies LOS ANGELES,CA 90,045 "Impact' (440)969-9773 Scope: This is a Product Evaluation report issued by R W Building Consultants,Inc.and Lyndon F.Schmidt,P.E.(System ID# 1998)for Plastpro Inc.based on Rule Chapter No.61G20-3,Method 1 D of the State of Florida Product Approval, Department of Business&Professional Regulation. RW Building Consultants and Lyndon F.Schmidt,P.E.do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 5th Edition(2014)Florida Building Code(FBC)structural requirements excluding the"High Velocity Hurricane Zone". 2. Product anchors shall.be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind bome debris protection this product complies with Section 1609.1.2 of the FBC and does not require an impact resistant covering.This product meets missile level°D"and includes Wind Zone 4 as defined in ASTM E1996 and Section 1609.1.2.2of the FBC.- 4. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL-17184.4 require further engineering analysis by a licensed engineer or registered architect 6. See drawing FL-17184.4 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed by TEL 01391120 TAS 20.1-94,202-94&TAS 203-94 Testing Evaluation Lab.,lnc. Lyndon F.Schmidt,P.E TEL 01390454 ASTM E18$6-05/E1996-06 Testing Evaluation Lab.,lnc. V.K.Wright ASTM E330-02 2. Miami-Dade NOA Materials Testina 14-0423.16 Saflex®PVB Interlayers(Eastman Chemical Company) 3. Drawing No. Prepared by Signed&Sealed by No.FL-17184.4 RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. 3Y -. . t 4. Calculations Prepared by Signed&Sealed by Anchoring RW Building Consultants,Inc.(CA#9813).q� =', FQ t °� Lyndon F.Schmidt,P.E. 5. Quality Assurance ,z, Certificate of Participation issued by National Accreditation and � • G •� `v�; �- Management Institute,certifying that Plastpro Inc.is manufacturing products _ }�r„ within a_quality assurance program that complies with ISO/IEC 17020 Lyndon F.Schmidt,P.E. Guide 53. yn "_?- =° FL PE No.43409 "`_.t� `''� 4/27/2015 Sheet 1 oft