Loading...
HomeMy WebLinkAboutProduct Approval FLAMaru`a tired Cc s� -1 Prrquam Business 1940Nloflh ci,,ceSle Sure ,% % Professional Ta'iahassee FIvAlas2380.0772 Phone.85^r 3718?4• Fax-850 414 R,35 Kerr Lawson,Secretary Rick Scott,Govemor July 31,2015- Melissa Smith Smithbilt Industries,Inc. 1061 Highway 92 West Auburndale,FL 33823 RE: Manufacturer Certification,ID MFT-208;Expiration Date:October 08,2016 Dear Melissa Smith r It is my pleasure to inform you that SmIthbilt Industries,Inc.,located at 1061 Hwy 92 West,n/a, Auburndale,FL 33823,has been approved under the Manufactured Buildings Program,as provided for under Chapter 553,Part I, Florida Statutes,to manufacture Storage Sheds, Manufactured Buildings for installation in Florida. Construction or modification on a manufactured building cannot begin until the Third Party Agency has approved the plans in accordance with the current Florida Building Code. Your Third Party Agency Is a contractor for the Department and has statutory authority and responsibilities that must be met to maintain approved status.You may expect and demand quality plans review and inspections. Each Code change will make your plans obsolete until they have been reviewed,approved and Indicated[on the cover page of the plans]for compliance with the Code by your Third Party Agency for plans review. Please ensure that your plans are in compliance and are property posted an our website.All site-related Installation Issues are subject to the local authority having jurisdiction. The Department's contractor will make unannounced monitoring visits at least once each year. You must grant complete access to your manufacturing facility and records to remain In compliance with the rules and regulations of this program. Your certification is approved for three years from this date.You will receive a renewal notice by Email generated by the BCIS(www.floridabuildina.org)for online renewal.If you have questions you may contact Robert Lorenzo at 850-717-1835 or our FAX at 850-414-8436. Please visit our website at www.flaridabuilding.ora to see valuable information on the Florida Manufactured Buildings P?ogram.A copy of this letter must accompany applications for local building permits. Sincerely, Robert Lorenzo Manufactured Buildings Program cc:Professional Service Industries , ;w'Tln form ion ff ;Pff . � f . OBuild On Iffingineedrig-Canstoffing-lboUng August 4,2015 Mr. Jim Richmond Florida Department of Business and Professional Regulation Manufactured Building Program 1940 North-Monroe Street Suite 90A Tallahassee, Florida 32399-0772 RE: Smithbilt Industries, Inc. Plan Approval SB Single Wide Streamline Dear Mr. Richmond, Pursuant to the requirements of the Florida Department of Business and Professional Regulations,the above referenced documents have been reviewed for compliance with: 2014 FSC, P Edition 2011 NEC 2014 Florida Fire Prevention Code These plans comply with Florida Product Approval Rule 61 G20-3.006 (FAC) A signed and sealed set of plans are maintained on file in the Third Party Agency office of PSI. All mandatory comments have been satisfied and plans are approved for construction by a modular building manufacturer that is currently approved by the Department of Business and Professional Regulations. If you have any questions or require my assistance in any way, please do not hesitate to.. contact me. Respectfully submitted, William E. Neary, Ill" Department Manager Modular Facilities Division Copy: Melissa Smith, misgysmith904@gmaii.com Professional Service Industries,Inc.a 1748 331d Street*odando,FL 32839 o Phone 407/304-5560 p Fax 407/304-5561 FL Engineering Business 3684 SMITHBILT INDUSTRIES, INC. PORTABLE BUILDING ANCHORS BUILDING ANCHOR SCHEDULE BUILDING SIZE NO. OF ANCH_ @ NO. OF ANCH. @ TOTAL ANCH_ EA. END OF BLDG. EA. SIDE OF BLDG. PER BLDG. 6', 8', 10', 12' & 14' WIDE TO 24' LONG 2 NA 4 48' 2 1 6 50' 2 2 8 20', 22' & 24' WIDE TO 24' LONG 4 NA 8 48' 4 1 10 50' 1 4 2 12 BUILDING ANCHOR DATA MODEL LENGTH BAR EYE HELIX UPLIFT CAPACITY NUMBER DIAMETER DIAMETER DIAMETER IN NORMAL SOIL 36SHE34 30" 1 1/2 1 1/2" 4" 2500 lbs. NOTE: THESE ANCHORS MEET THE WIND REQUIREMENTS OF THE FLORIDA 2014 BUILDING CODE, 5TH EDITION AND THE AMERICAN SOCIETY OF CIVIL ENGINEERS STANDARD CODE ASCE/SEI 7-10- WIND LOAD: 190 MPH BOLT THRU ANCH. & 2x6 SKID OR HEADER BEAM w/j"0x4" LAG BOLT SKID (TYP.) w/h" x 2"0 WASHER SIDE ANCH.� O DBL. WIDE ONLY MBAR .1 I� HELIX END ANCH. ANCHOR SPACING PLAN EARTH ANCHOR g'0 LAG BOLT 4" WELDED CHAIN o NOTE: REFER TO BU LDING ANCHOR 'I— SCHED LE F ANCHOR SPACI G e"0 LAG BOLT w/LEAD INSERT y{�/r OR J"O RAMSET RED HEAD CONCRE A8 TRUBOLT WEDGE (CAT. No BY OTHERS WW-3826) OR EQUAL CONCRETE ANCHOR BOLT DETAIL A A 5 SCALE NONE I DATE I LOCATION OF JOB A A_w J.McCARTHY ENGINEERING,LLC PORTABLE BUILDING ANCHORS DRAWN BY WDM 11 11 13 ANYWHERE FL V4 STRUCTURAL CONSULTANTS LAKELAND.FLORIDA SINGLE AND DOUBLE WIDE BUILDINGS CHECKED BY WJM 111/11/1314305 ORANGEWOOD ORCLE—LAKELAND.FL 33613 SMITHBILT INDUSTRIES INC. CHECKED BY PROJECT NO. PHONE(663)646-9390 CERRFICATE OF AUDIORIZALON No.31206 AUBURNDALE FLORIDA 1511 Wil6um J NcCarihy P.E 24553 WG.NO A-1 REV. ,-S SMITHBILT INDUSTRIES, INC. PORTABLE BUILDING ANCHORS BUILDING ANCHOR SCHEDULE BUILDING SIZE NO. OF ANCH. @ NO. OF ANCH. @ TOTAL ANCH_ EA. END OF BLDG_ EA. SIDE OF BLDG. PER BLDG. 6', 8', 10', 12' & 14' WIDE TO 24' LONG 2 NA 4 48' 2 1 6 50' 2 2 8 20', 22' & 24' WIDE TO 24' LONG 4 NA 8 48' 4 1 10 50' 4 2 12 BUILDING ANCHOR DATA MODEL LENGTH BAR EYE HELIX UPLIFT CAPACITY NUMBER DIAMETER I DIAMETER I DIAMETER IN NORMAL SOIL 36SHE34 30" 1/2" 1-1-1/2"/2" 4" 1 2500 lbs. NOTE: THESE ANCHORS MEET THE WIND REQUIREMENTS OF THE FLORIDA 2014 BUILDING CODE, 5TH EDITION AND THE AMERICAN SOCIETY OF CIVIL ENGINEERS STANDARD CODE ASCE/SEI 7-10. WIND LOAD: 190 MPH BOLT THRU ANCH. & 2x6 SKID OR HEADER BEAM w/i"9x4" LAG BOLT SKID (TYP.) w/32' x 2"0 WASHER SIDE ANCH.� O DBL. WIDE ONLY - - -- - - - - —BAR _ _ - HELIX END ANCH. ANCHOR SPACING PLAN EARTH ANCHOR 3'0 LAG BOLT 4" WELDED CHAIN ° • NOTE:. REFER TO BUILDING ANCHOR •i—D - SCHLDLEF ANCHOR SPA NG ;85"0 LAG BOLT w/LEAD INSERT I—I I ' �`//r. OR y"O RAMSET RED HEAD CONCRETEkSLB ar TRUBOLT WEDGE (CAT. NO. BY OTHERS WW-3826) OR EQUAL CONCRETE ANCHOR BOLT DETAIL to A AJ5 SCALE NONE I DATE LOCATION OF JOB k A W.J.McCARTHY ENGINEERING,LLC PORTABLE BUILDING ANCHORS DRAWN BY WDM 11/11/13 ANYWHERE, FL I V9STRUCTURAL CONSULTANTS LAKELAND.FLORIDA SINGLE AND DOUBLE WIDE BUILDINGS CHECKED BY WJM 111/11/13 4305 ORANGEWOOD ORCiE—LAKELMID,FL 33813 PHONE(863)646-9390 SMITHBILT INDUSTRIES INC. CHECKED BY PROJECT NO. CERIIFlCATE OF AUTHORIZATION No.31206 AUBURNDALE FLORIDA 1511 r".1 J McCarthy RE 24553 DWG,NO A-1 REV.