Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_46.aspx?parm=wGEVX... RECEI\"-:D JAN 2 6 2016 FILE COP ®Y lit _._... . — Florida Depaamentq BCIS Home Log In User Registration Hot Topics Submit Surcharge I Stats&Facts i publications i FBC Staff { BCIS Site Map Links ? Search Busines !, ;, Profe--M- l } *l Product Approval USER:Pubdc User Regulation Product ADDroyal Menu>Product or ApOcatlon Search>APPYCatbn List>Application Detail FL# FL6785-R6 Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Carlisle Coatings&Waterproofing Address/Phone/Email 900 Hensley Lane Wylie,TX 75098 (717) 245-7000 Ext 7456 wert@syntec.carlisle.com Authorized Signature Chad Wert wert@syntec.car]isle.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 08/01/2016 Validated By John W. Knezevich,PE Validation Checklist-Hardcopy Received Certificate of Independence FL6785 R6 COI 2015 01 COI Nieminen.odf Referenced Standard and Year(of Standard) Standard Year ASTM D1970 2009 Equivalence of Product Standards Certified By Sections from the Code of 2 1/26/2016 8:37 AM Florida Building Code Online https://www.floridabuilding.org/pr/pr app_ tl.aspx?param=wGEVX... Product Approval Method Method 1 Option D Date Submitted 02/27/2015 Date Validated 03/01/2015 Date Pending FBC Approval 03/05/2015 Date Approved 04/15/2015 Summary of Products FL# Model,Number or Name Description 6785.1 CCW Roof Underlayments Self-Adhesive Roofing Underlayments Limits of Use Installation Instructions Approved for use In HVHZ:No FL6785 R6 II 2015 02 FINAL ER CARLISLE UNDERLAYMENTS FL6785- Approved for use outside HVHZ:Yes R6.Ddf Impact Resistant:N/A Verified By: Robert Nieminen 59166 Design Pressure:N/A Created by Independent Third Party:Yes Other:Refer to ER Section 5 for Limits of Evaluation Reports Use. FL6785 R6 AE 2015 02 FINAL ER CARLISLE UNDERLAYMENTS FL6785- R6.pdf Created by Independent Third Party:Yes Back FN..tl Contact Us::1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,emall addresses are public records.If you do not want your e-mall address released In response to a pubic-rerords request,do not send electronic mail to this entity.Instead,contact the office by phone or by tradRbnal mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address r they have one.The emalls provided may be used for official communlcatbn with the licensee.However email addresses are pubic record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made avallable to the public.To determine 9 you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: PWM ® eCfKl ,cct ritcsu•mit ics° !of 2 1/26/2016 8:37 AM T ° EXTERIOR RESEARCH&DESIGN,LLC. .. Certificate of Authorization#9503 � K '-J 4� �^I � '1 1T ICD CIS® 353 CHRISTIAN STREET,UNIT#13 1 OXFORD,CT 06478 PHONE:(203)262-9245 FAX:(203)262-9243 EVALUATION REPORT Carlisle Coatings&Waterproofing Evaluation Report C39180.12.11-R3 900 Hensley Lane FL6785-116 Wylie,TX 75098 Date of Issuance:12/09/2011 Revision 3:02/04/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: CCW Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 3. Prepared by: IN of The facsimile seal appearing was authorised Robert J.M.Nieminen P.E. °•.Fs ? by Robert Nleminen,P.E.on 02/04/2015 This does not serve as an electronically signed document.Signed, Florida Registration No.59166,Florida DCA ANE1983 sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. \JTRINITYI ER® ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: CCW Roof Underlayments, as produced by Carlisle Coatings & Waterproofing, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Prope Standard Year 1507.2.4,1507.2.8(3),1507.2.9.2, Physical Properties ASTM D1970 2009 1507.4.5.1,1507.4.5.2(3), 1507.5.3,1507.5.3.2(3),1507.7.3, 1507.7.3.2(3) 3. REFERENCES: Entity Examination Reference Date ERD(TST6049) Physical Properties C41280.10.12 10/05/2012 MTI(TST2508) Physical Properties PX02MOA 01/17/2011 MTI(TST2508) Physical Properties PXI6MOA 01/18/2011 MTI(TST2508) Physical Properties PX13MOB 01/18/2011 ICC-ES(EVL2396) 2012&2009 IBC/IRC Compliance ESR-1556 04/01/2014 ICC-ES(EVL2396) 2012&2009 IBC/IRC Compliance ESR-2206 04/01/2014 UL,LLC.(QUA9625) Quality Control TGDY.R18678 Listing 10/18/2010 UL,LLC.(QUA9625) Quality Control Inspection Report,R18678 08/01/2014 4. PRODUCT DESCRIPTION: 4.1 CCW WIP 100 is a self-adhering,fiberglass reinforced,granule surfaced,rubberized asphalt roof underlayment. 4.2 CCW WIP 250 is a self-adhering,fiberglass reinforced,film surfaced,rubberized asphalt roof underlayment. 4.3 CCW WIP 300HT is a self-adhering,coated-polyolefin-composite film surfaced,rubberized asphalt roof underlayment. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this report;refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 CCW Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed,a request may be made to the AH1 for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable roof covers applied atop the underlayments are follows: TABLE 1. ROOF COVER OPTIONS Asphalt Wood Shakes Slate& Underlayment Shingles Nail-on Tile Foam-On Tile Metal &Shingles Synthetic Slate/Shake CCW WIP 100 Yes No No No No No CCW WIP 250 Yes No No Yes No No CCW WIP 300HT Yes No No Yes No Yes Exterior Research and Design,U.C. Evaluation Report C39180.12.11-R3 Certificate ofAuthorization 119503 FL6785-116 Revision 3:02/04/2015 Page 2 of 3 TRINITY i ER® i 5.6 Allowable substrates are noted below: 5.6.1 Direct-Bond to Deck: Self-adhering membranes applied to: ❑ New untreated plywood; ❑ Primed new untreated plywood; ❑ Existing plywood; ❑ Primed existing plywood; Note:While not required,CCW-702 or CAV-GRIP primer may be used when deemed appropriate or when temperatures are below 40T. 5.6.2 Bond to Mechanically Attached Base Laver: Self-adhering membranes applied to: ❑ ASTM D226,Type I or II felt; For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. 5.7 Exposure Limitations: 5.7.1 CCW WIP 100,CCW WIP 250 and CCW WIP 300HT shall not be left exposed for longer than 30-days after installation. 6. INSTALLATION: 6.1 CCW Roof Underlayments shall be installed in accordance with Carlisle Coatings & Waterproofing published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application. Prime the substrate(if applicable)with CCW-702 or CAV-GRIP Primer. 6.3 CCW WIP 100,CCW WIP 250 and CCW WIP 300HT: 6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.3.2 While not required,CCW-702 or CAV-GRIP primer may be used when deemed appropriate. Priming is required when temperatures are below 40'F. 6.3.3 Cut WIP roofing underlayment into 10 to 15 ft lengths. Remove 2 to 3 ft of release film and align the edge of the membrane,sticky-side down,so it overhangs the drip edge by 3/8-inch. Continue to remove release film and press as you move across the roof. Use a hand roller and/or hand pressure to press into place. 6.3.4 Horizontal seams should be minimum 3.5-inches, configured to shed water. Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course below. 6.3.5 Consult Carlisle Coatings&Waterproofing for steep slope&back nailing requirements. 6.3.6 For Valleys and Ridges: Cut WIP roofing underlayment into manageable lengths. Align over the center of the valley, hip or ridge. Remove release film. Press the middle of the membrane first before working toward the edges. For open valleys,cover roofing underlayment with metal valley liners. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the manufacturer or the named QA entity for plants covered under Rule 61G2G-3 CIA requirements. 9. QUALITY ASSURANCE ENTITY: UL,LLC—QUA9625;(847)664-3281 -END OF EVALUATION REPORT- Exterior Research and Design,I.I.C. Evaluation Report[39180.12.11-R3 Certitcate of Authorization#9503 FL6785-R6 Revision 3:02/04/2015 Page 3 of 3