HomeMy WebLinkAboutProduct Approval Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_46.aspx?parm=wGEVX...
RECEI\"-:D JAN 2 6 2016
FILE COP ®Y lit
_._... . —
Florida Depaamentq BCIS Home Log In User Registration Hot Topics Submit Surcharge I Stats&Facts i publications i FBC Staff { BCIS Site Map Links ? Search
Busines !, ;,
Profe--M- l } *l Product Approval
USER:Pubdc User
Regulation
Product ADDroyal Menu>Product or ApOcatlon Search>APPYCatbn List>Application Detail
FL# FL6785-R6
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer Carlisle Coatings&Waterproofing
Address/Phone/Email 900 Hensley Lane
Wylie,TX 75098
(717) 245-7000 Ext 7456
wert@syntec.carlisle.com
Authorized Signature Chad Wert
wert@syntec.car]isle.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 08/01/2016
Validated By John W. Knezevich,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL6785 R6 COI 2015 01 COI Nieminen.odf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2009
Equivalence of Product Standards
Certified By
Sections from the Code
of 2 1/26/2016 8:37 AM
Florida Building Code Online https://www.floridabuilding.org/pr/pr app_ tl.aspx?param=wGEVX...
Product Approval Method Method 1 Option D
Date Submitted 02/27/2015
Date Validated 03/01/2015
Date Pending FBC Approval 03/05/2015
Date Approved 04/15/2015
Summary of Products
FL# Model,Number or Name Description
6785.1 CCW Roof Underlayments Self-Adhesive Roofing Underlayments
Limits of Use Installation Instructions
Approved for use In HVHZ:No FL6785 R6 II 2015 02 FINAL ER CARLISLE UNDERLAYMENTS FL6785-
Approved for use outside HVHZ:Yes R6.Ddf
Impact Resistant:N/A Verified By: Robert Nieminen 59166
Design Pressure:N/A Created by Independent Third Party:Yes
Other:Refer to ER Section 5 for Limits of Evaluation Reports
Use. FL6785 R6 AE 2015 02 FINAL ER CARLISLE UNDERLAYMENTS FL6785-
R6.pdf
Created by Independent Third Party:Yes
Back FN..tl
Contact Us::1940 North Monroe Street,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,emall addresses are public records.If you do not want your e-mall address released In response to a pubic-rerords request,do not send electronic
mail to this entity.Instead,contact the office by phone or by tradRbnal mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address r they have
one.The emalls provided may be used for official communlcatbn with the licensee.However email addresses are pubic record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made avallable to the public.To determine 9 you are a licensee under Chapter
455,F.S.,please click here.
Product Approval Accepts:
PWM
® eCfKl
,cct ritcsu•mit ics°
!of 2 1/26/2016 8:37 AM
T ° EXTERIOR RESEARCH&DESIGN,LLC.
.. Certificate of Authorization#9503
� K
'-J
4� �^I � '1 1T ICD CIS® 353 CHRISTIAN STREET,UNIT#13
1 OXFORD,CT 06478
PHONE:(203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
Carlisle Coatings&Waterproofing Evaluation Report C39180.12.11-R3
900 Hensley Lane FL6785-116
Wylie,TX 75098 Date of Issuance:12/09/2011
Revision 3:02/04/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have evaluated for compliance with the 5th Edition (2014) Florida Building Code sections
noted herein.
DESCRIPTION: CCW Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 3.
Prepared by:
IN
of
The facsimile seal appearing was authorised
Robert J.M.Nieminen P.E. °•.Fs ? by Robert Nleminen,P.E.on 02/04/2015
This does not serve as an electronically signed document.Signed,
Florida Registration No.59166,Florida DCA ANE1983 sealed hardcopies have been transmitted to the Product Approval
Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
\JTRINITYI ER®
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: CCW Roof Underlayments, as produced by Carlisle Coatings & Waterproofing, have demonstrated
compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Prope Standard Year
1507.2.4,1507.2.8(3),1507.2.9.2, Physical Properties ASTM D1970 2009
1507.4.5.1,1507.4.5.2(3),
1507.5.3,1507.5.3.2(3),1507.7.3,
1507.7.3.2(3)
3. REFERENCES:
Entity Examination Reference Date
ERD(TST6049) Physical Properties C41280.10.12 10/05/2012
MTI(TST2508) Physical Properties PX02MOA 01/17/2011
MTI(TST2508) Physical Properties PXI6MOA 01/18/2011
MTI(TST2508) Physical Properties PX13MOB 01/18/2011
ICC-ES(EVL2396) 2012&2009 IBC/IRC Compliance ESR-1556 04/01/2014
ICC-ES(EVL2396) 2012&2009 IBC/IRC Compliance ESR-2206 04/01/2014
UL,LLC.(QUA9625) Quality Control TGDY.R18678 Listing 10/18/2010
UL,LLC.(QUA9625) Quality Control Inspection Report,R18678 08/01/2014
4. PRODUCT DESCRIPTION:
4.1 CCW WIP 100 is a self-adhering,fiberglass reinforced,granule surfaced,rubberized asphalt roof underlayment.
4.2 CCW WIP 250 is a self-adhering,fiberglass reinforced,film surfaced,rubberized asphalt roof underlayment.
4.3 CCW WIP 300HT is a self-adhering,coated-polyolefin-composite film surfaced,rubberized asphalt roof underlayment.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way,the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this report;refer to current Approved Roofing Materials Directory for fire ratings of this
product.
5.4 CCW Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed,a request may be made to the AH1 for approval based on this evaluation
combined with supporting data for the prepared roof covering.
5.5 Allowable roof covers applied atop the underlayments are follows:
TABLE 1. ROOF COVER OPTIONS
Asphalt Wood Shakes Slate&
Underlayment Shingles Nail-on Tile Foam-On Tile Metal &Shingles Synthetic
Slate/Shake
CCW WIP 100 Yes No No No No No
CCW WIP 250 Yes No No Yes No No
CCW WIP 300HT Yes No No Yes No Yes
Exterior Research and Design,U.C. Evaluation Report C39180.12.11-R3
Certificate ofAuthorization 119503 FL6785-116
Revision 3:02/04/2015
Page 2 of 3
TRINITY i ER®
i
5.6 Allowable substrates are noted below:
5.6.1 Direct-Bond to Deck:
Self-adhering membranes applied to:
❑ New untreated plywood;
❑ Primed new untreated plywood;
❑ Existing plywood;
❑ Primed existing plywood;
Note:While not required,CCW-702 or CAV-GRIP primer may be used when deemed appropriate or when temperatures
are below 40T.
5.6.2 Bond to Mechanically Attached Base Laver:
Self-adhering membranes applied to:
❑ ASTM D226,Type I or II felt;
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements.
5.7 Exposure Limitations:
5.7.1 CCW WIP 100,CCW WIP 250 and CCW WIP 300HT shall not be left exposed for longer than 30-days after installation.
6. INSTALLATION:
6.1 CCW Roof Underlayments shall be installed in accordance with Carlisle Coatings & Waterproofing published
installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application. Prime the substrate(if applicable)with CCW-702 or CAV-GRIP Primer.
6.3 CCW WIP 100,CCW WIP 250 and CCW WIP 300HT:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections 1507 for the
type of prepared roof covering to be installed.
6.3.2 While not required,CCW-702 or CAV-GRIP primer may be used when deemed appropriate. Priming is required when
temperatures are below 40'F.
6.3.3 Cut WIP roofing underlayment into 10 to 15 ft lengths. Remove 2 to 3 ft of release film and align the edge of the
membrane,sticky-side down,so it overhangs the drip edge by 3/8-inch. Continue to remove release film and press as
you move across the roof. Use a hand roller and/or hand pressure to press into place.
6.3.4 Horizontal seams should be minimum 3.5-inches, configured to shed water. Vertical seams should be 6-inches and
staggered not less than 2-ft from vertical seams in the course below.
6.3.5 Consult Carlisle Coatings&Waterproofing for steep slope&back nailing requirements.
6.3.6 For Valleys and Ridges: Cut WIP roofing underlayment into manageable lengths. Align over the center of the valley,
hip or ridge. Remove release film. Press the middle of the membrane first before working toward the edges. For
open valleys,cover roofing underlayment with metal valley liners.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS:
Contact the manufacturer or the named QA entity for plants covered under Rule 61G2G-3 CIA requirements.
9. QUALITY ASSURANCE ENTITY:
UL,LLC—QUA9625;(847)664-3281
-END OF EVALUATION REPORT-
Exterior Research and Design,I.I.C. Evaluation Report[39180.12.11-R3
Certitcate of Authorization#9503 FL6785-R6
Revision 3:02/04/2015
Page 3 of 3