HomeMy WebLinkAboutRoof Inspection Affidavit Planning& Development Services Building&Code Regulation Division 2300 Virginia Avenue -�, Fort Pierce, FL 34982 mm�* BAD772-462-2165 or 772-462-2172 Fax: 772-462-6443 ROOF INSPECTION AFFIDAVIT Re: Permit# I, Larry Neese , licensed as a(n)Contractor*/Engineer/Architect (Please print name&circle license type) *FS468 Building Inspector *General,Building,Residential or Roofing Contractor or any individual certified under 468 F.S.to make such an inspection. l I did personally inspect the roof deck nailing On or about 112 (Date) work at: 3122 SUNRISE BLVD Fort Pierce, FL 34982 (Job site address) Based upon that examination I have determined the installation was done according to the current edition of the Florida Existing Building Code Section 611 or the product approval submitted (whichever is most s !!2 CCC1330608 Si ure a Seal License# STATE OF FLORIDA COUNTY OF SkI Swo n to and subscribed before me this aS' day of 2016, by Who is personally known to me or who has produced FSR "10. 1,Q as identification. Notary Public,State Florida �dSpRy nip Signature of Nota Commission Number: : �*Mvallotary pSyAHNA ING *a;My C Public,g RAM of Fioa`O•'', omm. c. tate of Fl �� En 01/19/2011 """" Bood�ommissionires Bec 20,20da a�9 National Nota 249 8 Nota 249 Assn TURQUOISE Engineering, LLC Structural Engineering, Design & Testing, CA#28948, NOA#13-0222.02 6915 Washington Rd,W Palm Beach, FL 33405/Ph. (561)804-9908/Fax(561)804-9907/e-mail:turginc@aol.com January 18, 2016 TO: St Lucie County/ Building Department FROM: Riza N. ALTAN, P.E. SUBJECT: Wind Uplift & TPO Roof ReCover Specifications ADDRESS: SMITH Residence /3122 Sunrise Blvd., Ft Pierce, FL 34982 CONTRACTOR: Larry Neese Roofing, LLC Dear Sir; The roof recovering specifications of the subject flat roof is reviewed by myself. The purpose of this letter is to determine the wind uplift pressures and specify enhanced spacing of mechanical fasteners for the proposed TPO membrane roofing. The flat roof takes place in Exposure C area and ,the mean roof height is 15 ft. The existing 35'x65' roof consists of trusses spaced at 24" o.c. and 3/4" thick plywood deck having positive drainage. Roof design pressures are determined as per 2014 Florida Bldg Code, ASCE 7-10 for 165 MPH ultimate wind speed, Risk Category II in Exposure C area as follows: Field Pi = -44 psf / Perimeter (4' wide) P2= -74 psf / Corner (4'x4') P3= -111 psf. The proposed Carlisle TPO Single Ply Roofing System over Wood Decks (FL14083-R10) consists of re-nailed 3/4" T-n-G wood deck, loose-laid slip sheet, mechanically installed 60 mil SureWeld membrane, secured using Carlisle HPx fasteners and Piranha plates spaced 6" o.c. along 48"wide rolls. The max. design pressure of -75 psf (Table 1D, Syst Type E-1, System No. W-7, pg.:5/39, Limitation Note #9) specifies that membrane will be overlapped a min. of 5.5" and heat- welded a min. of 11/2'wide at the outer end. It is required that, as per RAS 117 in ordd to meet the actual roof pressures, the membrane is fastened to the existing 3/4" "CDX T-n-G wood deck in the following enhanced pattern: Zone 1: Field (Intermediate areas): @ 6"o.c., along 48" wide membrane in mid-sheet Zone 2: Perimeter (4' from edges): @ 6"o.c., along 48" wide membrane in mid-sheet Zone 3: Corner (4' from ea. side): @ 12"o.c., in 12" grid, each way in mid-sheet Laps: Field (4"min.): @ Vo.c., Perimeter & Corners: @ Vo.c. Therefore, this letter is to certify that installation of Carlisle TPO Single Ply Roofing System (FL14083-R10) conforms to requirements of 2014 FL Building Code which specifies 165 MPH ultimate wind speed for Risk Category II in Exposure C area. If you have any questions regarding this matter or%1yipfi of further assistance, please do not hesitate to call me. �0+�\1�. N. Alpg Sincerely, > s•••��C�NSF••• �, '•�}— No.38521 • STATE OF Riza N. ALTAN, P. # 521 - o •° • Consulting Engineer `'��o,�'• �ORIO #&I��`� ��so>®,P0N !a NG$�a`�