Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 4 i k"A r z EVA r ilit)w Dcf line --x BCIS Home ! Log In ; User Registration ; Ho[Topta Submit Surcharge Statr&Facts Publications FBC Staff j BCIS Site Map Links Search i Busines „ Professional Product Approval USER:Public User Regulation Product ADproyal Menu>Product or Application Search>Application List>Application Detail FL# FL8228-R7 Application Type Affirmation Code Version 2014 Application Status Approved Comments Archived ❑ Product Manufacturer Masonite International Address/Phone/Email 1955 Powis Road West Chicago, IL 60185 (615)441-4258 sschreiber@masonite.com Authorized Signature Steve Schreiber sschreiber@masonite.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Certification Mark or Listing Certification Agency National Accreditation&Management Institute Validated By National Accreditation&Management Institute Referenced Standard and Year(of Standard) Standard Year ASTM E1886 2002 ASTM E1996 2002 ASTM E330 2002 TAS 202 1994 Equivalence of Product Standards Certified By 2I affirm that there are no changes in the new Florida Building Code which affect my product(s)and my product(s) are in compliance with the new Florida Building Code. Documentation from approved Evaluation or Validation Entity OYes ONo ON/A Product Approval Method Method 1 Option A http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquftCwaMPtp3T... 1/27/2016 Florida Building Code Online Page 2 of 4 Date Submitted 04/29/2015 Date Validated 04/29/2015 Date Pending FBC Approval Date Approved 05/04/2015 Summary of Products FL# Model, Number or Name Description 8228.1 Fiberglass Side-Hinged Door Unit 6'-8"Opaque I/S and O/S Single Door Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL8228 R7 C CAC NI006900.01.1)d f Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 12/31/2020 Design Pressure: +85.0/-85.0 Installation Instructions Other: Evaluated for use in locations adhering to the FL8228 R7 II FL0160Dx.l)df Florida Building Code including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements as determined by Created by Independent Third Party: ASCE 7,does not exceed the design pressures listed.3'-0"x Evaluation Reports 6'-8" max nominal size. Hurricane protective system FL8228 R7 AE 504A.odf required in HVHZ,but not required in the Wind Borne Debris Created by Independent Third Party:Yes Region.See DWG-MA-FLO160-07 for additional information. 8228.2 Fiberglass Side-Hinged Door Unit 8'-0"Opaque I/S and O/S Single Door Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL8228 R7 C CAC NI006900.02.od f Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 12/31/2020 Design Pressure: +70.0/-70.0 Installation Instructions Other: Evaluated for use in locations adhering to the FL8228 R7 II FL0161Dx.odf Florida Building Code including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements as determined by Created by Independent Third Party: ASCE 7,does not exceed the design pressures listed.3'-0"x Evaluation Reports 8'-0" max nominal size. Hurricane protective system FL8228 R7 AE 503A.odf required in HVHZ,but not required in the Wind Borne Debris Created by Independent Third Party: Yes Region.See DWG-MA-FLO161-07 for additional information. 8228.3 Fiberglass Side-Hinged Door Unit 6'-S"Opaque Inswing Single or Double Door w/or w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL8228 R7 C CAC NI006900.01.od f Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 12/31/2020 Design Pressure: +50.5/-50.5 Installation Instructions Other: Evaluated for use in locations adhering to the FL8228 R7 II FL0160Dx.odf Florida Building Code including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements as determined by Created by Independent Third Party: ASCE 7,does not exceed the design pressures listed. 12'-0" Evaluation Reports x 6'-8"max nominal size.Hurricane protective system FL8228 R7 AE 502A.odf required in HVHZ,but not required in the Wind Borne Debris Created by Independent Third Party:Yes Region.See DWG-MA-FLO160-07 for additional information. 8228.4 Fiberglass Side-Hinged Door Unit 6'-8"Opaque Outswing Single or Double Door w/or w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL8228 R7 C CAC NI006900.01.od f Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 12/31/2020 Design Pressure: +55.0/-50.5 Installation Instructions Other: Evaluated for use in locations adhering to the FL8228 R7 II FL0160Dx.i)df Florida Building Code including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements as determined by Created by Independent Third Party: ASCE 7,does not exceed the design pressures listed. 12'-0" Evaluation Reports x 6'-S"max nominal size. Hurricane protective system FL8228 R7 AE 502A.odf required in HVHZ,but not required in the Wind Borne Debris Created by Independent Third Party:Yes Region.See DWG-MA-FLO160-07 for additional information. 8228.5 Fiberglass Side-Hinged Door Unit 8'-0"Opaque Inswing Single or Double Door w/or w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL8228 R7 C CAC NI006900.02.od f Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 12/31/2020 Design Pressure: +50.5/-50.5 Installation Instructions Other:Evaluated for use in locations adhering to the FL8228 R7 II FL0161Dx.odf Florida Building Code including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements as determined by Created by Independent Third Party: http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquftCwaMPtp3 T... 1/27/2016 Florida Building Code Online Page 3 of 4 ASCE 7,does not exceed the design pressures listed. 12'-0" Evaluation Reports x 8'-0"max nominal size.Hurricane protective system FL8228 R7 AE 501A.odf required in HVHZ,but not required in the Wind Borne Debris Created by Independent Third Party: Yes Region.See DWG-MA-FLO161-07 for additional information. 8228.6 Fiberglass Side-Hinged Door Unit 8'-0"Opaque Outswing Single or Double Door w/or w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL8228 R7 C CAC NI006900.02.0 f Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 12/31/2020 Design Pressure: +55.0/-50.5 Installation Instructions Other: Evaluated for use in locations adhering to the FL8228 R7 II FL0161Dx.odf Florida Building Code including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements as determined by Created by Independent Third Party: ASCE 7,does not exceed the design pressures listed. 12'-0" Evaluation Reports x 8'-0"max nominal size.Hurricane protective system FL8228 R7 AE 501A.odf required in HVHZ, but not required in the Wind Borne Debris Created by Independent Third Party:Yes Region.See DWG-MA-FLO161-07 for additional information. 8228.7 Fiberglass Side-Hinged Door Unit 6'-8"Glazed Inswing Single o r Double Door w/or w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL8228 R7 C CAC NIO06900.03.od f Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 12/31/2020 Design Pressure: +52.0/-52.0 Installation Instructions Other:Evaluated for use in locations adhering to the FL8228 R7 II FL0162Dx.odf Florida Building Code including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements as determined by Created by Independent Third Party: ASCE 7,does not exceed the design pressures listed. 12'-0" Evaluation Reports x 6'-8"max nominal size.Hurricane protective system FL8228 R7 AE 502A.odf required in HVHZ and the Wind Borne Debris Region.See Created by Independent Third Party: Yes DWG-MA-FLO162-07 for additional information. 8228.8 Fiberglass Side-Hinged Door Unit 6'-8"Glazed Outswing Single or Double Door w/or w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL8228 R7 C CAC NIO06900.03.od f Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 12/31/2020 Design Pressure: +55.0/-55.0 Installation Instructions Other:Evaluated for use in locations adhering to the FL8228 R7 II FLO162Dx.odf Florida Building Code including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements as determined by Created by Independent Third Party: ASCE 7,does not exceed the design pressures listed. 12'-0" Evaluation Reports x 6'-8"max nominal size.Hurricane protective system FL8228 R7 AE 502A.Ddf required in HVHZ and the Wind Borne Debris Region.See Created by Independent Third Party:Yes DWG-MA-FLO162-07 for additional information. 8228.9 Fiberglass Side-Hinged Door Unit 8'-0"Glazed Inswing Single o r Double Door w/or w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL8228 R7 C CAC NI006900.04.1)d f Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 12/31/2020 Design Pressure: +40.0/-45.0 Installation Instructions Other: Evaluated for use in locations adhering to the FL8228 R7 II FLO163Dx.odf Florida Building Code including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements as determined by Created by Independent Third Party: ASCE 7,does not exceed the design pressures listed. 12'-0" Evaluation Reports x 8'-0"max nominal size.Hurricane protective system FL8228 R7 AE 501A.odf required in HVHZ and the Wind Borne Debris Region.See Created by Independent Third Party:Yes DWG-MA-FLO163-07 for additional information. 8228.10 Fiberglass Side-Hinged Door Unit 8'-0"Glazed 0utswing Single or Double Door w/or w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL8228 R7 C CAC NIO06900.04.od f Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 12/31/2020 Design Pressure: +43.0/-47.0 Installation Instructions Other:Evaluated for use in locations adhering to the FL8228 R7 II FLO163Dx.pdf Florida Building Code including the High Velocity Hurricane Verified By: National Accreditation&Management Institute Zone,and where pressure requirements as determined by Created by Independent Third Party: ASCE 7,does not exceed the design pressures listed. 12'-0" Evaluation Reports x 8'-0"max nominal size.Hurricane protective system FL8228 R7 AE 501A.odf required in HVHZ and the Wind Borne Debris Region.See Created by Independent Third Party: Yes DWG-MA-FLO163-07 for additional information. http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquftCwaMPtp3T... 1/27/2016 Florida Building Code Online Page 4 of 4 8228.11 Fiberglass Side-Hinged Door Unit 6'-8"Impact Glazed Inswing Single or Double Door w/or w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL8228 R7 C CAC NI006900.05.Dd f Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 12/31/2020 Design Pressure: +52.0/-52.0 Installation Instructions Other: Evaluated for use in locations adhering to the FL8228 R7 II FL0162Dx.odf Florida Building Code not including the Hig h Velocity Verified By: National Accreditation&Management Institute Hurricane Zone,and where pressure requirements as Created by Independent Third Party: determined by ASCE 7 do not exceed the design pressures Evaluation Reports listed. 12'-0"x 6'-8"max nominal size.See DWG-MA- FL8228 R7 AE 502A.Ddf FLO162-07 for additional information. Created by Independent Third Party: Yes 8228.12 Fiberglass Side-Hinged Door Unit 6'-8"Impact Glazed Outswing Single or Double Door w/or w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL8228 R7 C CAC NI006900.05.od f Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 12/31/2020 Design Pressure: +55.0/-55.0 Installation Instructions Other:Evaluated for use in locations adhering to the FL8228 R7 II FL0162Dx.odf Florida Building Code not including the Hig h Velocity Verified By: National Accreditation&Management Institute Hurricane Zone,and where pressure requirements as Created by Independent Third Party: determined by ASCE 7 do not exceed the design pressures Evaluation Reports listed. 12'-0"x 6'-8"m ax nominal size.See DWG-MA- FL8228 R7 AE 502A.odf FLO162-07 for additional information. Created by Independent Third Party:Yes 8228.13 Fiberglass Side-Hinged Door Unit 8'-0"Impact Glazed Inswing Single or Double Door w/or w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL8228 R7 C CAC NI006900.06.od f Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 12/31/2020 Design Pressure: +40.0/-45.0 Installation Instructions Other: Evaluated for use in locations adhering to the FL8228 R7 II FL0163Dx.odf Florida Building Code not including the Hig h Velocity Verified By: National Accreditation&Management Institute Hurricane Zone,and where pressure requirements as Created by Independent Third Party: determined by ASCE 7 do not exceed the design pressures Evaluation Reports listed. 12'-0"x 8'-0"max nominal size.See DWG-MA- FL8228 R7 AE 501A.odf FLO163-07 for additional information. Created by Independent Third Party:Yes 8228.14 Fiberglass Side-Hinged Door Unit 8'-0"Impact Glazed Outswing Single or Double Door w/or w/o Sidelites Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL8228 R7 C CAC NI006900.06.1)d f Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 12/31/2020 Design Pressure: +43.0/-47.0 Installation Instructions Other: Evaluated for use in locations adhering to the FL8228 R7 II FLO163Dx.odf Florida Building Code not including the Hig h Velocity Verified By: National Accreditation&Management Institute Hurricane Zone,and where pressure requirements as Created by Independent Third Party: determined by ASCE 7 do not exceed the design pressures Evaluation Reports listed. 12'-0"x 8'-0"m ax nominal size.See DWG-MA- FL8228 R7 AE 501A.odf FLO163-07 for additional information. Created by Independent Third Party:Yes Back Next Contact Us::1940 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: M] RLMAN P,.'...tECF M !�CC1111L};k F.'f'li 11`5' http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquftCwaMPtp3T... 1/27/2016 NOTICE OF PRODUCT CERTIFICATION Company: Masonite International Corporation Certificatioat-!1_o___.D X06900 l0lp 1955 Powis Road Certification Date: 01/14/2007 West Chicago,IL 60185 Expiration Date: 12/31/2020 F,n Revision Date: 11/21/2014 �"p' Product: Fiberglass Opaque Inswing or Outswing Door w/and w/o Non-Impact Rated Sidelites (w/Wood Frame unless noted) `` .1. . Specification: TAS 202/ASTM E330/ASTM E1886/E1996 Impact Rating:Wind Zone 4-Missile Level D The"Notice of Product Certification'is only valid if the NAMI Certification Label has been applied to the product as described within this document. The certification label represents product conformity to the applicable specification and that all certification criteria has been satisfied. This product has been approved for listing within NAMPs Certified Product Listing at www.Namicertification.com. NAMI's Certification Program is accredited by The American National Standards Institute(ANSQ. Inswing Glazed Structural Water Missile Test Report Number Configuration or or Maximum Design Test Impact Drawing Number& Outswin -Opaque Size Pressure Pressure Rated Comments X G I75` Opa ue7 TEEM z 6'si f85C 1=8s Lip �:�a �, 86 Sf:' Y.es r�NC TL 210=3358-t 1 ) tSing el `. Maximam t'anet Size:3'0 8" Anchor Detail-NIA-FLO160-07 X O/S Opaque 3'0"x 6'8" +85/-85 10.5 psf Yes NCTL-210-3358-1/CTLA-772W Single Maximum Panel Size:3'0"x 6'8" Anchor Detail-MA-FLO160-07 XX I/S Opaque 6'0"x 6'8" +50.5/-50.5 2.86 psf Yes NCTi,-210-3105-1/210-3314-IA.CTLA-772W-2 Double Maximum Panel Size:3'0"x 6'8/Sidelite;3'0"x 61" Anchor Detail-MA-FLO160-07 XX O/S Opaque VY'x 6'8" +55/-50.5 6,00 psf Yes NCTL-210-3105-1/210-33314-IA.CTLA-772W-2 Double 8.25 psi Maximum Panel Size:3'O"x 6'8"/Sidelite:3'0"x 6'8" /// Anchor Detail-MA-FLO160-07 IXO/OXO {I15 Opaque-Door-' co x`.6'8-/ +50;51-50;5` $6 7f' Door_yes-1 NCTL-210�3�105=172tO=3314':IA:CTCA=772 Singlc w/Sidelite - Glazed"SideliteSidelite-Na Max1mum Panel'Sii 3'0"x 6'8'YSide t—c.3'0"x 6'8" Anchor Detail-MA-FLO160-07 XO/OX O/S Opaque Door 6'0"x 6'8" +551-50.5 6,00 psf Door-Yes NCTL-210-3105-1/210-3314-IA.CTI-A-772W-2 Single w/Sidelites Glazed Sidelite 8.25 psf* Sidelite-No Maximum Panel Size:3'0"x 6'8"/Sidelite:3'0"x 6'8" Anchor Detail-MA-FLO160-07 OXO I/S Opaque Door 9'0"x 6'8" +50.51-50.5 2,86 psf Door-Yes NCTL-210-3105.1/210-3314-IA.CTLA-772W-2 Single w/Sidelites Glazed Sidelites Sidelites-No Maximum Panel Size:3'0"x 6'8/Sidelite:3'0"x 6'8" Anchor Detail-MA-FLO 160-07 OXO O/S Opaque Door 910"x 6'8" +551-50.5 6,00 psf Door-Yes NCTL-210-310S.1/210-3314-IA.CCLA-772W-2 Single w/Sidelites Glazed Sidelites 8,25 psf* Sidelites-No Maximum Panel Size:3'0"x 6'8/Sidelite:3'0"x 6'8" Anchor Detaii-MA-FLO160-07 OXXO 1/S Opaque Doors 12'4"x 6'8" +50.5/-50.5 2.86 psf Doors-Yes NCTL-210-3105-1/210-3314-I A.CTLA-772W-2 Double w/Sidelites Glazed Sidelites Sidelites-No Maximum Panel Size:3'0"x 6'8"/Sidelite:3'0"x 6'8" Anchor Detail-MA-FLO160-07 OXXO O/S Opaque Doors 12'4"x 6'8" +55/-50.5 6,00 psf Doors-Yes NCTL-210-3105-1/210-3314-IA.CTLA-772W-2 Double w/Sidelites Glazed Sidelites 8,25 psf* Sidelites-No Maximum Panel Size:3'0"x 6'8/Sidelite:3'O"x 6'8" Anchor Detail-MA-FLO160-07 *Denotes High Dam Threshold Design National Accreditation&Management Institute,Inc./4794 George Washington Memorial Highway/Hayes,VA 23272 Tel:(804)684-5124/Fax:(804)684-5122 NAMI AUTHORIZED SIGNATURE: 40 ;4;*%4X 0',TPAA FPA'.Ir%T. Tu ------------- cr_ MAX36�375' P, -HINGED FIBERGLASS DOOR UNIT _j Co SIDE 21' VAX. JPANkl. W)VIH 37.5" MAX. 6'-8"DOUBLE DOOR WITH/WITHOUT SIDELITES INIASTRAGAL FRAME WIDT14 GENERAL NM Q cs I. EVALUATED FOR USE IN LOCATIONS ADHERING TOG THE FLORIDA BUILDING CODE AND WHERE PRESSURE Lu 0 REQUIREMENTS AS DETERMINED BY ASCE 7, MINIMUM u DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, DOES NOT EXCEED THE DESIGN PRESSURES LISTED. LIf) 2. WHEN INSTALLED IN THE HIGH VELOCITY HURRICANE ZONE (HVHZ), Lr) HURRICANE PROTECTIVE SYSTEM (SHUTTERS) IS REQUIRED. -q I V 11 3. WHEN INSTALLED IN THE WINO-BORNE DEBRIS REGION, co EXCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ), _� 5 4 LLJ HURRICANE PROTECTIVE SYSTEM IS NOT REQUIRED ON OPAQUE LZ z PANELS OR PANELS WITH IMPACT GLASS, BUT!S REQUIRED ON PANELS WITH NON-IMPACT GLASS. wou 4. POLYURETHANE CORE FLAME SPREAD NDEX OF 50 AND SMOKE DEVELOPED INDEX OF 60 PER ASTM E84. P` POLYSTYRENE CORE FLAME SPREAD INDEX OF 15 AND SMOKE DEVELOPED INDEX OF 115 PER ASTM E84. 5. PLASTICS­.LSTINO OF FIBERGLASS FACING: ¢Ln TEST DESCRIPTION DESIGNATION RESULT SELF IGNITION TEMP ASTM D1929752'F > 650'F RATE OFYRNING ASTM 0635 I SMOKE DENSITY ASTM D2843 53AX If I if TENSILE STRENGTH• ASTM 0648 -1 3.2% DIFF "4 52 0 6. PLASTICS TESTING OF LITE FRAME MATERIAL: TEST DESCRIPTION DESIGNATION RESULT SELF ICNITION TEMP LA" DQ01L DOOR LIMIT I t ES 650'F IQ, PATE OF BURNING SMOKE DENSITY 5 M D2843 In 1-TENSILE STRENGTH` 7 coffi*m1117: • COMPARATIVE TENSILE STRENGTH AFTER WEATHERINGLL Iolz%A 4500 HOURS XENON ARC METHOD I Z� 7. IMPACT GLAZING LAMINATE MIAMI LADE BCCO NOA 09-0127.13 tJl ....... ......... FUR C) u 0. 0 z U 13 013 103 1 13 Cl 0 U 13 13 U 13 M ul 0 Z(L 2� Do 00 , ou .00 Do: an .01 0 C-1 N 0 0 L Li 100 ,19 il 11 00 11 00 SINGLE DOOR UNIT DOUBLE OWR UNI SINGLE OOOjP UIW SINGLE 02QR UNIT SINGLE 00QR UNJr WISIDIFILITS pI0=E poOp_;1M7_w'5jofLtTEs WITH SfOELIT WITH SIDELITE a VIM< WHERE WATER INFILTRATION PERFORMANCE IS TABLE OF CONTENTS DESIGN PRESSURE RATING REQUIRED TO BE 15% OF DESIGN PRESSURE DAYD 1/5/07 CON iG MAX WIDTH INSWING OUTSWI G INSWING oulWING QIJF'iWING* SCALE: N.T.S. SHE" DESCRIPTION X 37.5 +850 -85.0 +85. _wo: +70.0 / -70.0 +70.0 --70.0 4ri on.st �sws EVATIONS & GENERAL NOTES 0.5 + -50.6 140.0 / -40.0 v55.O -sat) 2 ANCHORING LOCATIONS & DETAILS OXor +55 0 4 -505 +4;DO '--40.0 +55.0 -50.5 CNK.BY: 3 ANCHORING Z-190 O'D LOCATIONS & DETAILS OXO L2.5 -�56.5 T, I 9:.�O�4 40.0 +55. - KURT&ALTHAZOR Oxxp 2-Z -505 19.0 1+40.0 / -4U.0 1+5b,U r-50.5 FLORIDA P.E. DWG-MA-:7.0160-07 - High Jutu Threst,aW Design CL: Do Er 1 J6^ U 0 6' SEE 1 E.. DETAIL ' "I O s . I X. J —Ij 3" O ' -zc U)C) 6" W O 3' I c o It�— ^ ? Q T in cli „"III N r1 W �f� O W •f �n1 Z LoL n V z a SEE DETAIL Lu n O SEE DETAIL — w — _ SEE DETAIL w w I "c' CE 0 6., 6" 3" _ I o„ I I I I I 6 I 11 I ` T 1 _...._.-=i— a 6., ✓,,�I }r 6' SEE DETAIL •� �'�p l:n(n m ^F„ C91dICilbIi H0.: Nim_ REviemBY I el IQ< #8 x 2-1/2' —rc gyp. II'"ILL I3 a I I AS i RAGAI. RETAINER BOLT HOLE z o i` MUST BE DRILLED THROUGH Ja, c) �j��THE #10 x 2° THRESHOLD & INTO THE aEn Lw i> #8 x 2-1/2 DETAIL "E" ASTRAGAL STRUCTURL DEEP ENOUGH ri n z a FOR A 1.375" THROW g= cr #10 x 5/8" ATTACH ASTRAGAL RETAINER SOLT #8 x 2-1/2" i#10 x 3/a'" STRIKE PLATE TO FRAME DETAIL ASTRA.GAL 0 #10 x 5/8" #10 x 3/a" AS SHOWN. �N 0.12r ANNEALED DECORATIVE INSERT #10 x 2" / 0.090'SAFLEX Inc j (OPTIONAL) DOVE 532 - I FRAME / DOOR 0.124'ANNEALED—_...- .0:24'TEMP. #6% 1-1/2'PNS t' DETAIL "D" DETAIL "C" o v m<1 1- TYPICAL �i� -•4; :;yam": �—I-1 �. DOW sae :•,a,a Dow Bat / �:�a.y sca.E: N.T.S. 0.962"I t.75' lt.C47' :4.% DOW oow 8321-- 1.7 12 :: -I I v:' Owl.By: S1ji 1..17.5" C a EX!fFR3 It;QE81StB EXTrRf0H •�-... Ly1ER1Ol? CI+1(.9r. T T T TYPICAL GLAZING DETAIL TYPICAL GLAZI:G DETAIL ORAWNG HO. i . C LASS Dwc-laA-v! r. ,e1r,t.`r INSWIN THRES;IOI�D OUTSWING THRESHOLD HIGH DAM 0/S THRESHOLD IMoA rRAT �GASS NON' IMPACT_�_ I SNEeT 2 Luis R. lamas P.E. 1432 Woodford Rd. Manufacturer:Masonite Lewlaviffa,NC 27023 Report#:502A- 33"45-9895 Date: 12129/09 Product: Double Door with sidelftes 12'x6'8" Scone: This analysis provides calculations,quantifies,and spacing requirements for installing product to substrate,and it applies only to the product described herein.These calculations comply with requirements of the Florida Building Code. Drawings verification: This analysis verifies anchoring for the following drawings: DWG-MA-FLO120-05 DWG-MA-FL0132-05 DWG-MA-FL0147-06 DWG-MA-FL0162-07 DWG-MA-FLO122-05 DWG-MA-FLO134-05 DWG-MA-FLO151-06 DWG-MA-FL0168-07 DWG-MA-FLO124-05 DWG-MA-FLO140-05 DWG-MA-FL0153-06 DWG-MA-FLO170-07 DW(3-MA-FL0126-05 DWG-MA-FL0142-05 DWG-MA-FLO155-06 DWG-MA FLO172-07 DWG-MA FLO128-05 DWG-MA-FLO143-05 DWG-MA-FLO156-06 DWG-MA-FLO174-07 DWG-MA-FLO130-05 DWG-MA-FLO146-06 DWG-MA-FLO160-07 DWG-MA-FL0175-07 Anchors to be auafflfiecl: 1.#10 Wood screw,for installation in wood frame substrates, 2.3116"ITW Tapson,for masonry installation Anchor capacity in shear condition: Fastener type:1110 wood screw (NDS 2005.11.3) Side member:Douglas Fir-Larch Main member:Spruce-Pine-Fir Side member thickness: t't 1.000 in Main member thickness; tM= 1.500 in Side member dowel bearing strength: Fa= 4,650 psi Main member dowel bearing strength; F•„= 3,350 psi Minimum required penetration: 1.330 in Screw banding yield strength: Fyb z 80,000 psi Duration Factor. Co= 1h Tabulated lateral design volue: Zz 107.0 lbs Allowable besisn Value: Z'= 171 lbs/anchor Mode IV Fastener type;3/16"ITW Tapson N.O.A.07-1126.10 Substrate.Hollow block Minimum embedment. 125 in Minimum edge distance: 1,13 in Minimum C to C spacing: 2.25 In Tabulated shear design value: Z= 112 lbs Actual C To C spacing: 3.00 in Minimum edge distance; 2.63 in C to C spacing foctorl 1.00 Tabulated shear design value: Z- 197 lbs Actual edge distance: 2.50 in Design value per interpolation: Z z 189 lbs Allowable Design Value: Z'z 189 lbstanchor Oftim"anchor capacity: 171 lbs/4111chor Plate:Anchors with the least capacity is used for calculations to qualify anchors with higher capacity. Anchor calculations,mirtimum required anchors Double. Pressure aaclinst stops with bum threshold: 36.38 fi 36.38- Design pressure: 60.0 psf Al /\ At Area Load Ind. Max. Anchor A 3 yzom (ft2) (lbs) (in) O.C. cap* Qty Load Result Azk 13 79.25 (in) (tbs) Obs) At Ai A, 2.3 138 NIA NIA 171 1 138 _0K A2 7.7 463 6.00 21.00 171 5 93 OK A3 7.7 463 NIA WA 171 3 154 , OK 0 �51 • TAT OF • low ,�f''�sS`aNAL���G'�~ OR ctt Luis R.Lomas P.E. FL No.:62514 1 of 11712010 Luis R. Lamas P.E. 1432VkodrordRd. Manufacturer.Masonite LewiWffle,NC 27023 Report#: 502A 335.945-9695 Date: 12/29/09 bauble. Pressure away from stops: 36.38 36.38 Design pressure: 60.0 psf Area load Ind. M'a'y. Anchor Zone O.C. Cap. Load Result At1 •1 Al 79.25 (f►2) Obs) (in) fps} {lbs} Qty {lbs) Af 10.0 601 6.00 21.00 171 5 124 OK A, 10.0 601 NIA N/A 171 4 1 150 OK 72.75 Double. Pressure against stops with saddit threshold: 36.38 36.38 Design pressure: 60.0 psf t Arca Load Ind. Max. Anchor ai Ai Zane� z O.C. Cap. Load Result (f:) abs) (in) (in) (lbs) .QtyLoadY79.25 Ai 2 3 138 WA NIA 171 1 138 OK Az 8.9 532 6.00. 21.00 171 5 106 OK ^" 1 A3 7.7 463 NIA NIA 171 3 154 OK 72.75 A4 24A 601 NIA I NIA 171 4 150 OK Double with sidelites.PPressure against stops with l8 m},t threshold: Design pressure: 60.0 psf 37.50 36.38 36.38 37.50 Area Load Ind Max. Anchor Al A4 A4 Al ? Zone (ftz) (lbs) On) O.G. Cap. Qty Load Result Azy Y Y YAI 2.4 146 WA W A� (lbs) i A 172 1 146 OK 79.25 Az 7.9 473 6.00 21.00 171 5 95 OK At A4 Aa A3 7,$ 468 WA NIA 171 3 156 OK _ A4 2.3 138 WA N/A 171 1 138 OK 147.75 A5 7.7 463 WA NIA 171 3 154 OK Double with sidelltes. Pressure away from stops: Design pressure: 60.0 psf 37.50 36.38 36.38 37.50 Area Load Ind. Max. Anchor Zone O.G. Cap. Load Result Al tAl (ft) Obs) (in) (in) fibs) QtyObs) ,�Y J 79.25 Al 2.4 146 NIA WA 171 1 146 OK A3 M 1 03 Az 7.9 473 6.00 21.00 171 5 95 OK Al At { A3 8.9 537 NIA NIA 171 4 134 OK ,. . A4 10.0 601 NIA N/A 1 171 1 4 1150 OK 147.75 oublt with sidelites. Pressure against stm with saddle threshold: Design pressure: 60.0 psf 37.50 36.38 36.38 37.50 Max. Anchor Area Load Ind, fi '' _It" A � Zone 2 O.C. Cap. Load Rest Al JAI (ft) Obs) (in) (fn) Obs} Q'y fibs} �YfTf, A, 2.4 146 NJA WA 171 1 146dK79.25 A2 7.9 473 6.00 21.00171 5 95 OK At A3 7.8 468 NIA' NIA 171 3 156 OK A4 8.9 537 WA NIA 171 4 134 OK 147.75 A5 2.3 138 WA NIA 171 1 138 OK A6 7.7 463 NIA N/A 171 3 154 OK A7 10.0 601 N/A NIA 17I 4 150 OK �`01111111fl, ��, R. 0 \o, 0� rwo „ TAT OF Luis R.Lomas P.E. FLNo.:62514 2 of 4 ONALG,\\�' 1/7/2010 _ 1�/1l11111� Luis R. Lomas A E. 1432 Woodford Rd. Manufacturer. Masonite Lewimile,NC 27023 Report#:502A Date: 12/29109 336.945-9695 Anchor Locations: Double door with sidelites k 29 Z m II o g � 0 1D tG � Note: Anchor locations indicated in this document are the minimum required for the described product exposed at the design pressure indicated herein. ``��1111 111 �;••`,�G E is. •`s"'% • TAT E OF f�iiS��NAt1E���� Luis R.Lomas P.E. FL No.:62514 3 of 4 1/7/2010 Luis R. Lomas A E. 1432WoodrordRd. Manufacturer: Masonite LewisWile,NC 27023 Report#:502A 336-945.9695 Date: 12/29109 Anchor Locations: Double door —36.36 �--- 36.36 6.00 TYP. 6.00 TYR 1 a.19 TYR 3.00 TYP. ^, i 7 6.00 13.45 MAX.O.C. 79.25 1 i 6.00 i Note: Anchor locations indicated in this document are the minimum required for the described product exposed at the design pressure indicated herein. N\J�5 G E N o'�'F STATE OF ��'��•�X ORVOA•' s�ONA�,tia���� Luis R.Lomas P.E. FL No.:62514 4 of 4 11712010 d