HomeMy WebLinkAboutDrawing R C WD
FEB 0 3 2016
PER:diITTING
St. Lucie County, FL
2
32" X 80" 72" X 96"
FL15129.9
U-FACTOR=0.15
1
FL15255.24
U-FACTOR=0.24
SHGC=0.18
REPLACE DOORS IN 2 OPENINGS ONLY.
OPENINGS HAVE EXISTING HURRICANE PROTECTION INSTALLED
UNDER PERMIT#1511-0244 PER HOMEOWNER.
OPENING PRODUCT DESIGN
OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS
NO. WDTH. HGT. FTG. ZONE POS. NEG. (N.O.A.#) POS. NEG.
1 72 96 48.00 4 34.6 -37.8 FL15255.24 47.0 -47.0 FRONT ENTRY-LSMI
2 32 80 17.78 4 37.3 -40.5 FL15129.9 75.0 -75.0 SIDE GARAGE-LSMI
REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS.
NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS.
ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 1/4" TAPCON SCREWS INTO CONCRETE
WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS.
PN\1
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRE UR
MEAN ROOF HEIGHT= 15 FT 8 IN
NALL RESIDENCE
7679 WEXFORD WAY DOOR REPLACEMENT PLAN
ST. LUCIE WEST, FLORIDA