HomeMy WebLinkAboutDrawing L-
72" X 80"
LAI
1
REPLACE DOORS IN 1 OPENING ONLY.
ECEWED
NEW DOORS TO BE IMPACT RESISTANT-
HURRICANE SHUTTERS NOT REQUIRED. FEB 0 3 201
PERMITTING
St. Lucie County, FL
OPENING PRODUCT DESIGN
OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS
NO. WDTH. HGT. FTG. ZONE POS. NEG. (N.O.A.#) POS. NEG.
1 72 1 80 40.00 4 34.4 1 -37.6 FL14569.4 60.0 -60.0 FRONT ENTRY-LSMI
REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS.
NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS.
ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH 3/16"TAPCON SCREWS INTO CONCRETE
WITH A MINIMUM 1 1/4"PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS.
I, = 4
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES
MEAN ROOF HEIGHT= 11 FT 6 IN
BARET RESIDENCE
3805 AVENUE M DOOR REPLACEMENT PLAN
FORT PIERCE, FLORIDA