HomeMy WebLinkAboutWind Load Calculation C
TIGHT
1918 Corporate Drive
Boynton Beach,FL33426
WIN D Ph.561-922-6747
Fax.561-292-3562
Property Information Building Information
Owner: Raymond Warren Wind Zone: 170 MPH.
Address: 107525 S Ocean Dr#507 Exposure Category: C
Jensen Beach,FL 34957 Minimum Building Dimension: 25 ft.
Mean Roof Height: 24 ft.
JU Risk Category: II
Design Pressure Calculations
OpeningLocation Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) I Elevation(ft) 11 Pressure(psf) Pressure(psf)
1 End 36 61 7 40.6 -53.6
2 End 36 — — 61 7 40.6 -53.6
--- 1-1----------- ------ ------------ ----- —----- -
3 End 36 61 7 40.6 -53.6
4 Int 36 61 7 40.6 -44.1
5 Int 36 61 7 40.6 -44.1
6 Int 36 61 7 40.6 -44.1
7 Int 36 50 7 41.1 -44.7
8 Int 26 37 7 41.7 -45.3
9 Int 25 49 7 41.7 -45.3
10 Int 25 49 7 41.7 -45.3
----------
11 Int 36 61 7 40.6 -44.1
— ---- __...........-------- ....._ - ._..._.._._....__..._..--------------- -----__........ —----- -- -
12 Int 36 61 7 40.6 -44.1
--------...--------
.-- -----_.._... --- ------ ------- --- — -
13 Int 36 74 7 40.1 -43.6
__..__..__......-.__... --.......----------._.._._...----------- ----------------- ----- —--...
14 Int 18 49 7 41.7 -45.3
Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.5th Edition(2014)Florida Building Code.
Page 1 of 1
igg
A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET
Definition of Corner Zone -10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft.
PRODUCT APPROVAL REQUIRED OPENING MAXIMU MULTIPLE
OPENING (Location) IS THIS A PRODUCT ROUGH ARE
GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M
LOCATION Corner Zone WINDOW TYPE ACCEPTANCE TESTED OPENING MULLION WINDOW SHUTTERS
NUMBER or Interior OR DOOR NUMBER (+)PSF (-)PSF (+)PSF (-)PSF DIMENSIONS REQ Y/N
SIZE
REQ Y/N/NA
1 End W 78"LamilG 15-0618.02 55 55 40.6 53.6 1 53x77 36x61 Y N
2 End W 7/8°LamilG 15-0618.02 55 55 40.6 53.6 1 5307 36x61 Y N
3 End w 7/8"Lanti1G 15-0618.02 55 55 40.6 53.6 5307 36x61 Y N
4 Int W 7/8"LamiIG 15-0618.02 55 55 40.6 44.1 5307 36x61 N N
5 Int w 7/8°LamilG 15-0618.02 55 55 40.6 44.1 5307 36x61 N N
6 Int W 78"LamilG 15-0618.05 55 55 40.6 44.1 36x68 36x61 N N
7 Int W 7/8°LamilG 15-0618.02 55 55 41.1 44.7 5307 36x50 N N
8 Int w 7/8°LamilG 15-0610.02 55 55 41.7 45.3 5307 26x37 N N
9 Int w 7/8"LamilG 15-0618.02 55 55 41.7 45.3 5307 25x49 N N
10 Int w 7/8"Lam1IG 15-0618.02 55 55 41.7 45.3 5307 25x49 N N
11 Int w 7/8°LamilG 15-0618.05 55 55 40.6 44.1 5307 36x61 N N
12 Int W 7/8°LamilG 15-0618.02 55 55 40.6 44.1 5307 36x61 N N
13 Int W 7/8°LamilG 15-0618.04 55 55 40.1 43.6 5205 36x74 N N
14 Int w 7/8"LamilG 15-0618.02 55 55 41.7 45.3 53x77 18x49 N N