Loading...
HomeMy WebLinkAboutWind Load Calculation C TIGHT 1918 Corporate Drive Boynton Beach,FL33426 WIN D Ph.561-922-6747 Fax.561-292-3562 Property Information Building Information Owner: Raymond Warren Wind Zone: 170 MPH. Address: 107525 S Ocean Dr#507 Exposure Category: C Jensen Beach,FL 34957 Minimum Building Dimension: 25 ft. Mean Roof Height: 24 ft. JU Risk Category: II Design Pressure Calculations OpeningLocation Device Device Device Max Positive Max Negative Number Zone Width(in) Height(in) I Elevation(ft) 11 Pressure(psf) Pressure(psf) 1 End 36 61 7 40.6 -53.6 2 End 36 — — 61 7 40.6 -53.6 --- 1-1----------- ------ ------------ ----- —----- - 3 End 36 61 7 40.6 -53.6 4 Int 36 61 7 40.6 -44.1 5 Int 36 61 7 40.6 -44.1 6 Int 36 61 7 40.6 -44.1 7 Int 36 50 7 41.1 -44.7 8 Int 26 37 7 41.7 -45.3 9 Int 25 49 7 41.7 -45.3 10 Int 25 49 7 41.7 -45.3 ---------- 11 Int 36 61 7 40.6 -44.1 — ---- __...........-------- ....._ - ._..._.._._....__..._..--------------- -----__........ —----- -- - 12 Int 36 61 7 40.6 -44.1 --------...-------- .-- -----_.._... --- ------ ------- --- — - 13 Int 36 74 7 40.1 -43.6 __..__..__......-.__... --.......----------._.._._...----------- ----------------- ----- —--... 14 Int 18 49 7 41.7 -45.3 Prepared in accordance with:ASCE 7-10,Chapter 30. Wind Loads-Components and Cladding.5th Edition(2014)Florida Building Code. Page 1 of 1 igg A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Corner Zone -10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft. PRODUCT APPROVAL REQUIRED OPENING MAXIMU MULTIPLE OPENING (Location) IS THIS A PRODUCT ROUGH ARE GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M LOCATION Corner Zone WINDOW TYPE ACCEPTANCE TESTED OPENING MULLION WINDOW SHUTTERS NUMBER or Interior OR DOOR NUMBER (+)PSF (-)PSF (+)PSF (-)PSF DIMENSIONS REQ Y/N SIZE REQ Y/N/NA 1 End W 78"LamilG 15-0618.02 55 55 40.6 53.6 1 53x77 36x61 Y N 2 End W 7/8°LamilG 15-0618.02 55 55 40.6 53.6 1 5307 36x61 Y N 3 End w 7/8"Lanti1G 15-0618.02 55 55 40.6 53.6 5307 36x61 Y N 4 Int W 7/8"LamiIG 15-0618.02 55 55 40.6 44.1 5307 36x61 N N 5 Int w 7/8°LamilG 15-0618.02 55 55 40.6 44.1 5307 36x61 N N 6 Int W 78"LamilG 15-0618.05 55 55 40.6 44.1 36x68 36x61 N N 7 Int W 7/8°LamilG 15-0618.02 55 55 41.1 44.7 5307 36x50 N N 8 Int w 7/8°LamilG 15-0610.02 55 55 41.7 45.3 5307 26x37 N N 9 Int w 7/8"LamilG 15-0618.02 55 55 41.7 45.3 5307 25x49 N N 10 Int w 7/8"Lam1IG 15-0618.02 55 55 41.7 45.3 5307 25x49 N N 11 Int w 7/8°LamilG 15-0618.05 55 55 40.6 44.1 5307 36x61 N N 12 Int W 7/8°LamilG 15-0618.02 55 55 40.6 44.1 5307 36x61 N N 13 Int W 7/8°LamilG 15-0618.04 55 55 40.1 43.6 5205 36x74 N N 14 Int w 7/8"LamilG 15-0618.02 55 55 41.7 45.3 53x77 18x49 N N