FL# FL10674-R11, Revision
-.. Application Type
Code Version 2014
Application Status Approved -pipe
pprovedlj•
e � -
Comments �T
Archived "
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Coming Parkway
Toledo,OH 43659
(740)404-7829
greg.keeler@owenscoming.com
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
Technical Representative Mel Sancrant
Address/Phone/Email 1.Owens Corning PKWY
Toledo,OH 43659
(419) 376-8360
mel.sancr-ant@owenscomig.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who Robert 7.M. Nieminen
developed the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 08/20/2017
Validated By ?ohn W. Knezevlch,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FUD674 R11 COI 2015 01 COI Meminen.pdP
Referenced Standard and Year(of Standard) Standard Year
ASTM D3161 2009
ASTM D3462 2009
ASTM D7158 2008
Equivalence of Product Standards
http://-,vww.floridabuilding.org/pr/pr_app dtl.aspx?param=wGEVXQwtDgtBNbEY5V%2b.__ 1/8/2016
Florida Building Code Online Page 2 of 2
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/15/2015
Date Validated 10/19/2015
Date Pending FBC Approval 1012012015
Date Approved 12115/2015
Summary of Products
JFL* — Model,Number or Name Description
10674.1 Owens Corning Asphalt Roofing 3-tab,4-tab,5-tab,laminated,starter and hip&ridge
Shingles and Starters Shingles
Limits of Use installation Instructions
Approved for use in HVHZ: No FL10674 R11 11 201510 FINALERASPHALT
Approved for use outside HVHZ:Yes SHINGLES FL10674-Rll.pdf
Impact Resistant:N/A Verified By: Robert J. M. Nieminen PE-59166
Design Pressure:N/A Created by Independent Third Party:Yes
Other., Refer to ER,Section 5. Evaluation Reports
FL10674 R11 AE 2015 10 FINAL ER OC ASPHALT
SHINGLES FL10674-R11j)df
Created by Independent Third Party: Yes
back Next
Contact Q 1910 North Monroe Street.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EED employer.Copyright 2007-2013 state of f lorida.*:Privacy statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not
send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.
.Pursuant to Section 455,27S(1),Florida Statutes,effective October 1,2022,licensees licensed under Chapter 455,F.S.must provide the Department
with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public
record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.
To determine if you are a licensee under Chapter 455,F,S.,please click here-
Product Approval Accepts:
W WE N. is
6ccu It V
htti)://www.floridabuildinp-.or2/t)r/Dr aDD dtl.asi)x?t)aram=wCTFVXO-.x4T)ntTANhPVc,'%10/-')I, 1/Q/IYA I A
'
^ ' EXTERIOR RESEARCH&DESIGN,LLC.
�
y oertifkntenyAum*mammmems
\ / — 35JCHRISTIAN STREET,UNIT#l3
� / l� x_���/8����
B &����U � OXFORD,[TO6478
' PHONE:(2D3)2G2-9z45
FAX:(2O3)2G2-9243
EVALUATION REPORT
Owens Corning Evaluation Report 037940.02.12-R6
One Owens Corning Parkway FL10674-Rll
Toledo,""°3"9 -a_of-Issuance:02/06/2012
Revision 6: 10y15/2815
SCOPE:
This Evaluation Report is issued under Rule 6IG20-3 and the applicable rules and regulations Qoxem(oQ the use of
construction materials In the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 5th Edition(ZD14)Florida Building Code sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report isvalid until such time asthe nomad pruducL(o) changes, the referenced
Quality Assurance documentation changes,or provisions of the[oda that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes orthe
referenced Quality Assurance documentation changes. Trinit/lEMD requires a complete review of this Evaluation Report
relative toupdated Code requirements with each Code Cycle.
AmvEnrmswEmr The Evaluation Report number preceded by the words "7rnhy|[RD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, ocopy ofthis.entireEvaluation Report shall beprovided tothe user hythe manufacturer prits
distributors and shall be available for inspection at the job site at the request of the Building Official. '
This Evaluation Report consists ofpages 1through 7.
Prepared by:
�~
The facsimile seal appearing vas authorized by Robe^wiemm=
Robert J.M.N�m�n��P�� ��
^ ` � ° ,.a""1011»20sw*u^^^no,se°"as="/"*="ically sig".*
Floridamegis"tion No.59166,Florida DCA ANE1983 document "�hardooples have been transmitted mthe
Product Approval Administrator and wthe named client
CERTIFICATION OF INDEPENDENCE:
1. Tdnhy|FRDdoes not have nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products/tevaluates.
2. TrInItyl ERD is not owned,operated or controlled by any company manufacturing or distributing products It evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert wiemincn,P.E.does not have,nor will acquire,a§nondm|interest in any other entity involved in the approval process.«fthe
product.
5. This is a building code evaluation. Nebhe,Trin'ity|ERo nor RnbertNieminen' P.E. are, in any way,the Designer wfRecord for any
project onwhich this Evaluation Report,orprevious versions thereof,is/was used for permitting o,design guidance unless retained
specifically for that purpose.
`
\
�
x m��NIm x i�`~~~�D/
ROOFING SYSTEMS EVALUATION.
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated
compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume
through testing in accordance with the following Standards, Compliance is subject to the Installation Requirements
and Limitations/Conditions ofUse set forth herein.
2. STANDARDS:
Section Property Standard� Year
1507.2.5,R905.2.4 Physical Properties ASTM D3462 2009
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3za1 2009
1507.2,7.1,R905.2.6.1 Wind Resistance ASTM D7158 2000
3. REFERENCES:
fnifty Examination Reference Date
ULLLC KIR982Q Physicals&Wind Resistance File R24S3,Val.3 02/15/2007
UL LLc(CsRg*76) Physicals aWind Resistance 20120516-n2453 05/16/2012
uLLLC(TSTg6z8) Physical Properties 00CA20263 04/18/2006
uLLLC(TsT9aux) Wind Resistance IICA34308 02/18/2012
UL LLc(TST96z8) Physicals&w0ndResistance 4786093137 02/01/2014
uLULC(nSTgs2a) Wind Resistance 4786126532 0y10/2014
ULLLc(rST9628) Physical Properties Classification letter 02/13/I014
uLLLC(TSTg62*) Physical Properties Classification letter 10/02/2015
Miami-Dade(CERz592) poCHV*ZCompliance vahousNOAs Various
ULLLC (QVm;§25) Quality Control Service Confirmation,R24S3 Exp.08/20/2017
4- PRODUCT Dsscnpnom'
4.1 Asphalt Shingles:
4.1.1 Classic-and Supreme*are fiberglass reinforced,3-tab asphalt roof shingles.
4.1.2 Berkshire'are fiberglass reinforced,4-tabasphalt roof shingles,
4.1.3 Devonshire'are fiberglass reinforced,5-tabasphalt roof shingles.
4.1,4 Duration', TrvDeOnldnn' Duration~, Duration' Premium Cool, TruDeOnition" Duration" Designer Color
Collection,TruDefinition.Oakridge',Oakridgea and WeatherGuard'HP are fiberglass reinforced,laminated
asphalt roof shingles.
4.2 Berkshire' Hip & Ridge Shingles, High Ridge, Hip & Ridge with Sealant, VVeatherGuard~ HP Hip & Ridge
Shingles,ProEdQeHip&Ridge Shingles and Duro0dgel Hip &Ridge Shingles are fiberglass reinforced, hip
and ridge asphalt roof shingles.
4.3 Starter Strip Shingle,Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
5. LIMITATIONS:
5.1 This is u building code evaluation. Nei1herThnityJERD nor Robert Ninrninen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, orprevious versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report isnot for use inthe HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings nfthis product.
Exterior Research and Design,mc Evaluation Report os79«ozu.1z-Rs
Certificate clo"mvriz"tio"m950u a10674-mu
Revision 6:10/15/2015
Page 2m7
|
. \ ~
« `
� ����
'� � ��8~�� � � ���^�°
5.4 Wind Classification:
5.4.1 All Owens Corning shingles noted herein are Classified in accordance with F8[ Tables 15072.7.1 and
R9u5.2.61toASTM D3161,Class Fand/or ASTM D7158, Class H, indicating the shingles are acceptable for
uohnall wind zones uptoV=^=15Umph (/m =184mph). Refer to Section 6 for installation requirements
tomeet this wind rating. `
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are
Classified inaccordance with FBCTables 15O7.Z.7.land n9D5.2.6.1toASTM D316l'Class F,indicating the
shingles are acceptable for usinall wind zones uptpV°,d=15Omph (\�^=194mph). Refer toSection 6
for installation requirements tnmeet this wind rating.
5.4.3 Classification 6yASTM D7158 applies to exposure category B or C and a building height of 60 feet or less.
Calculations by a qualified design professional are required for conditions outside these limitations.
Contact the shingle manufacturer for data specific toeach shingle.
5.4.4 RefertuOwens Corning published information onwind resistance andinstu||abonUnitatons.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building
Code and EA.C.Rule 61G20-3.
6. INSTALLATION:
6.1 Unde,laymnemt:
6'1.I Under|aYment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
App,oYa|,orbaLocally Approved per Rule G16ZQ-3,per F8CSections 15O7'2.I1507.2'4orR8O5.l.3.
6'2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using
minimum four (4) nails per shingle in accordance with FB[Sectinns 1507.2 or R905.2,with the following
exceptions:
> Berkshire'shingles require minimum five(S)nails per shingle.
VVeatherGuanjHPshingles require minimum six(6)nails per shingle.
Dexonshire=shingles require minimum six(6)nails per shingle.
�
Starter Strip Shingle and Starter Strip Plus require minimum five(5)nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6urR905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. Contact the shingle manufacturer for details.
6.2.5 Minimum Nailing—Starter Strip Shingle and Starter Strip Plus:
Felt underlayment Deck Felt mleflaym Dock Self*dhertd
underloyment
Dr
[D
located
'Neilslot-ated 2 -r from save
Install first
$eH-sealing adhesive AnstA first Stow Strip Plus
Starter Stri positioned along Dave 'r Positioned olong sevo
6"removed
Starter Strip shingle overhangs eaves and takes 11V-1'A" Starter strip Kus overhangs eaves and sdW 114"-3W
Exterior Research and Design,ULC. Evaluation Report o37940o�12-R6
certificate of Authorization#9503 o10674-xII
Revision 6:10115/201S
Page au,7
''- .` TRIM �ERD
6.2.6 Minimum Nailing—Classic®&Supreme:
- r
Normal Mansard or area para Normal Mansard or Aron pars
Wind Areas High Wind da vvenea v WindAreas High Wind desvanas y
Area per viarntos nornmaive Ames vientos foertes Area para What"normal!! Arcus viontas hwrtes
wExposure a 618'Exposure
Fxposki6n fttpoaioi6n
6.2.7 Minimum Nailing—Berkshire®:
SeaiarA strip 89aiara strip
La tka&5r.W r La lira&roliddor
8Ym` 9 Yt 5 Yt 8 Yf 8 Yt 8 Yt S Yt 8 Yt
�.
0
D ��
1
h�mm
z As*9 roormgcetMw"t
Qaarant*A tock do astatto
6.2.8 Minimum Nailing—DevonshireT":
a7 W
—'— Bails
e .--E... r t t r ..T
—.. _.._._.. —_._ t ..-
.z }r
��, y,• eJq•� 6..
Nails Ten 9 Spots of Asphalt Raof Gemern
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R6
Certificate of Authorization#9503 FL10674•R11
Revision 6:10/15/2015
Page 4 of 7
:4 TRII =ERCP
1
6.2.9 Minimum Nailing — Duration", TruDefinition" Duration, Duration" Premium Cool & Tru Definition®
Duration®Designer Color Collection:
o b
4 Nal Pattern 6 Nag Wsardard stapsl:py
bknbelmrn suaMe
Espow de 4 elavob Pattern area andlW dwlw.
Sunl4awabsWb)garaawirtth k5woma v8 a5 �FSaxndk N
Area doda�nsSavaNaP do husaepaPrat11
e�ria dHraak
1• �' titanr'q � � 9ueNaiP
rq radnYl
arra mdlA -�y�� �
YL' tr _ ,treads r
sv, 1z —trLE
SWExposoae Nails 5S"Exposure
RA pair,.ds oxposicvn Cb vas 546 pulp.do sxposkAdn
SW exposure Nails 5W Expostz;e
5a pdg.do expa*5fr Davos 5%puiq.de erposidan
6.2.10 Minimum Nailing—Tru Definition'Oakridge",Oakridge":
4 Nail Pattern 6 Nail Pattern
Esguana tort 4 ciavos Esqucma tan 6 elavos
I.r-- m —al ISE rr---�1 _ Imo-- u• --�{ IE— rr--�►{
5618"diPr+n' S 6/8"E ra Nab
Expasid6rrdcb6/Bprdg Clams Exposfca 6619pdg 5518"Exposum Clavas 6518'Exposu
Expasia6a doGS/B pdg. Exposicmr+do 55/8pulg.
6.2.11 Minimum Nailing—WeatherGuard®HP:
9
•tea. •r`• sst��3r t
6.3 Hip&Ridge Shingles:
6.3.1 Installation of Berkshire'Hip and Ridge Shingles, High Ridge, Hip&Ridge with Sealant,WeatherGuard HP
Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the manufacturer's current
published instructions, using four (4) nails per shingle. Installation of DuraRidge'"° Hip & Ridge Shingles
shall comply with the manufacturer's current published instructions, using two(2)nails per shingle. Refer
to Owens Corning published information on wind resistance and installation limitations,including the use
of hand-sealing for wind warranties.
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R6
Certificate of Authorization#9503 FL10674-R11
Revision 6:10/15/2015
Page 5 of 7
'ERD
,, .' TRINITYI
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing—Berkshire"Hip&Ridge and High Ridge:
Fig.I a4 Fig,2 SkIOIAM
Dkoclion
N\\ tdtlls Heil.
-P-75i,
�T
at!
N'
6.3.4 Minimum Nailing—Hip&Ridge with Sealant;
mem Fig.2-High UWbd Fastening fttwm
K Nails)
rrimiShIngla
and DiscaMa2 -2%p
Excess
j2"
scespnit
Strip 112"
Fastenino 5 S EXPOSU
Distanoe
k-- 12 er
6.3.5 Minimum Nailing—WeatherGuardO HP Hip and Ridge:
Fig,C Hip&Ridge Shingle Fastening
Fig.A Top VbW
vim
WILS
All
r.IZ-2. 44- kr
+
g• EXporntc
v",
12"
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R6
Certificate ofAutharizotion#9503 FL10674-R11
Revision 6:10/15/2015
Page 6 of 7
g tl SI I I ERR
6.3.6 Minimum Nailing-ProEdge Hip&Ridge Shingles:
i'ravailing S3andard 11*—
Wind I3irsationng
&ea3ott#Strut Pattern'�tt9Tn
12'
Fasten 71W 7'h° 6°Expoxtito
Com Expoevst
Fant mn with
P40f COMM I•--- 12®-=•i
6.3.7 Minimum Nailing—DuraRidget""Hip&Ridge Shingles:
Note: The drawings below pertain to minimum, as-tested attachment requirements. Refer to Owens
Coming published installation instructions for their minimum requirements.
Pir ti sWndDim,Son Yam
Dinttian1krnimnrodi�t vaa rbr
9inmkn M viwft pnclvmirmnto II' I'+t
Z ° v' 4hsmm Ci3egj"SaedfJail'"-,'�a Cbw
1
t�arat� I II
l 1
n � i sl9'E
8"
I I i t x
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1./R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625;(414)248-6409;karen.buchmann@ul.com
END OF EVALUATION REPORT-
Exterior Research and Design,LLC. Evaluation Report 037940.02.12-R6
CeraFcote of Authorization#9503 FL10674-R11
Revision 6:10/15/2015
Page 7 of 7